PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

Similar documents
PROFIBUS with FBP. Achieve everything with fewer components. NEW: PDQ22-FBP The bus node with. four units ABB

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

FBP FieldBusPlug FBP System Accessories

Universal Motor Controller UMC22-FBP. High-grade Motor Protection and Control

Motor control and protection Universal Motor Controller UMC100-FBP

FBP FieldBusPlug. Technical Manual. USB to FBP UTF21-FBP UTF21-FBP DTM V

Technical Description

System Description Advant Controller 31 Intelligent Decentralized Automation System. Notes for Project Planning. ABB Schaltund Steuerungstechnik

VersaMax IP Input Module

FBP FieldBusPlug Technical Catalogue. Communicative Control and Protection Components

Field bus connections Link structure BDC Link structure BDC, B-design. Brochure

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Copyright: December 2017 Nidec Issue: E

Field bus connections Link structure DDL Link structure DDL, bus coupler. Brochure

DX561 Digital Input/Output Module

ABB i-bus KNX Logic Controller ABA/S 1.2.1, 2CDG110192R0011

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

DI572 Digital Input Module

DI561 Digital Input Module

ABB i-bus KNX IP Router, MDRC IPR/S 3.1.1, 2CDG110175R0011

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

DC562, digital input/output module,

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

Accessories for pluggable interface relays CR-M Sockets

Serial PROFIBUS Interface

ABB i-bus KNX HCC/S Heating/cooling circuit controller

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

Motor control and protection Universal Motor Controller UMC100-FBP

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Diagnostics (Logical) Diagnostics (Physical)

PB IL 24 BK DIO 16/16

ABB i-bus KNX DALI Light Controller, 8-fold, MDRC DLR/S M, 2CDG110101R0011

Compact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]

CAN 300 PRO, Communication Module

AS-Interface I/O Module

PDP32.0 PROFIBUS DP-V1 Interface

Assortment Insertion / replacement of the Lithium battery Insertion of the SD Memory Card

PAC BI-DP BIM and 8701-CA-BI Carrier

DC561, digital input/output module,

AO561 Analog Output Module

SK TU4-PBR Part number:

VersaMax IP I/O Module

ABB i-bus KNX BCI/S Boiler/Chiller Interface

VAL-62. Fieldbus modules FD67 Series Input, output and analog modules with IP67 ingress protection. Valves

It is the installer's responsibility to follow all instructions in this manual and to follow correct electrical practice.

SK CU4-PBR-C Part number:

MCD 200 MCD 500. Remove the Profibus Module using the following procedure: 1. Remove power from the module.

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Powered Roller Controller for DeviceNet

Device manual AS-i PowerSwitch ZB0028 ZB0040

AI561 Analog Input Module

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Product Information. LS 1679 Incremental Linear Encoder with Integrated Roller Guide

PAS 300, PROFIBUS Slave Interface Module

Product Information. ECA 4000 Absolute Modular Angle Encoder

G3 Series PROFIBUS DP Technical Manual

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

System Control Unit (SCU)

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 BNI PBS Z001 Short Guide

AS-i 3.0 motor modules

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

Fieldbus slave modules w/o I/Os

SK TU4-IOE-M12-C Part Number

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Three-phase monitoring relay

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

N E W! SAI Panel Feed -Thro u g h S A I - M 1 2 / M 2 3 SA I- A New Wir ing Concep t. c o n c e p t s. c o s t s.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

TB3P/TB4P I/O PROFIBUS DP FIELDBUS MODULE FOR PNEUMATIC MANIFOLD VALVES. Pg. 1 di 14

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

Protected VARAN Digital Mixed Module PVDM 086

1) Examine exterior of package for signs of damage. Report any damage to shipping carrier.

IE/PB LINK PN IO. PROFINET applications

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

camera sensor ipf opti-check 1070 fully integrated camera system contour-based recognition

Table of contents chapter 1:

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

MANUAL Conversion instruction EDM series to VDM100 series

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

Digital electropneumatic Positioner for the integrated mounting on process control valves

1.5 axis motion controller

AS-i 3.0 motor module

CM592 PROFIBUS Communication Module

Operating Instructions. DALI-Gateway

- 15G0078B110 - PROFIBUS MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

IBS ST 24 BK-T INTERBUS-S. Data Sheet. Bus Terminal Module. Product Description

Preliminary Product Information. ECA 4000 Absolute Angle Encoder without Integral Bearing

Installation Instructions HIPERDRIVE HDA - with PROFIBUS DP - with cable adapter

B&R X67_IO_System_V3.14_E. X67 - System

Manual Industry Interfaces

Electronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet

Product Description. Altus S. A. 1

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

Supplementary instructions. VEGADIS adapter. For connection of an external display and adjustment unit or a slave sensor. Document ID: 45250

Transcription:

FBP FieldBusPlug V6 PROFIBUS DP FieldBusPlug PDP21-FBP PROFIBUS DP

PDP21-FBP PROFIBUS DP FieldBusPlug PROFIBUS DP Fig. 1: PDP21-FBP Fig. 2: PDP21-FBP, plugged to the Universal Motor Controller UMC22-FBP Contents Page Purpose and short description... 4 Connector pin assignment... 6 Indicators and operating elements on the front plate... 7 Technical data... 8 Ordering data... 9 Mechanical dimensions... 10 PDP21-FBP 3

Purpose and short description The PROFIBUS DP FieldBusPlug PDP21-FBP establishes the field bus connection between the PROFIBUS DP and the terminal devices connected to this bus. The PROFIBUS DP FieldBusPlugs are slaves (nodes) on the PROFIBUS DP. The terminal devices must have the field bus-neutral interface (e.g. as provided by the ABB FBP modules MSD11-FBP, MSR22-FBP, MFI21-FBP and UMC22-FBP). The data exchange between the PROFIBUS DP FieldBusPlug and the terminal device can be performed in two ways: Parallel communication The signals are exchanged directly via the connections of the field bus-neutral interface. Scope of data: max. 1 digital output (1 control signal to terminal device) plus 2 digital inputs (2 feedback signals from terminal device). If the FieldBusPlug does not receive any telegram from the terminal device during power-on, this mode of data exchange will be set. Serial communication The signals are exchanged with the help of a serial data protocol via the field bus-neutral interface. Binary, analog, parameter and diagnostic data is sent and received. As soon as the FieldBusPlug receives a valid telegram from the terminal device, this mode of data exchange will be set non-volatile. The PROFIBUS DP FieldBusPlug PDP21 behaves as an input/output module on the PROFIBUS. During the initialization phase, the plug receives the device-specific data from the terminal device. This data is equal to the corresponding data in the bus master, provided that the correct terminal device was selected there. The GSD file ABB_078F.GSD, belonging to it, contains the list of terminal devices which can be connected, including the parameters with their selection possibilities. When opening the GSD file, the parameters appear. During start-up, their setting is transferred from the bus master to the plug. The plug forwards this data to the terminal device without checking. To make sure, that the bus master can access the slaves connected to the bus line, a setting of the slave addresses is always necessary. Generally and over the full address range, the CAS21-FBP addressing set can be used. But it is easier, if the terminal device has address setting switches or similar means for the address setting. In this case, the FieldBusPlug adopts the address from the terminal device during power-on. Once the address is set, it is stored in the FieldBusPlug, even in case of supply voltage breakdown. According to the PROFIBUS DP standard, the addresses 1 to 126 can be set (recommended 3 to 125). The addresses 0...2 and 127...128 are reserved and should not be used for slaves. 126 is the default address, some bus masters can change this address during operation, provided that it is used only with one slave at the bus. For diagnosis purposes, the PROFIBUS DP FieldBusPlugs are equipped with four LEDs (see Fig. 4). In addition to the two signal cores, the PROFIBUS cable contains two cores for 24 V. This voltage is always necessary for supplying the FieldBusPlugs. The voltage can be fed-in at the bus master, for example. Caution: False polarity or reversal between bus lines and power supply lines can cause a destruction of the FieldBusPlug. Supplying the terminal devices can be selected as follows: Internal supply (switch position "INT"): The terminal device is powered from the bus cable, too. External supply (switch position "EXT"): The terminal device is powered by a remote power supply. This is necessary, if the current consumption is high or if there are components installed to the terminal device, which are not nearby, e.g. proximity switches. There is an electrical isolation between the PROFIBUS DP signals and the field busneutral interface. 4 PDP21-FBP

In order to build up a PROFIBUS DP bus line using PROFIBUS DP FieldBusPlugs, the FieldBusPlugs must be simply connected in series, i.e. the cable of the first FieldBusPlug is plugged to the PROFIBUS DP distributor (in the direction of the bus master), the cable of the second FieldBusPlug is plugged to the socket of the first plug, etc. To make work easier, the PROFIBUS-DP FieldBusPlugs are available with different cable lengths. On the field bus side, the plugs work like T connectors. For very long distances, several cable extensions are available as well as cable coils and male and female plug connectors for self-mounting. The PROFIBUS DP must be terminated with active bus-line terminators of 150 Ω at each end of the bus. In general, the bus master is put to the beginning of the bus line. In many cases, the bus master incorporates a bus-line terminator, which can be activated by a switch. There are also PROFIBUS DP plugs which include switchable bus-line terminators. At the end of the bus line, the bus-line terminator PDR11-FBP can be used. It is then mounted to the M12 socket of the FieldBusPlug. When determining the total bus length, all cables belonging to the PROFIBUS DP FieldBusPlugs must also be taken into account. They are part of the PROFIBUS. Due to their compound construction, the PROFIBUS DP FieldBusPlugs comply with the requirements of IP 65 and consequently can also be mounted outside the control cabinet. Usually, the last free connector of a FieldBusPlug chain is connected to a bus-line terminator and thus also meets IP 65. PDP21-FBP 5

Connector pin assignment Fig. 3 shows the connector pin assignment of the FieldBusPlug for the PROFIBUS DP interface (plug at the cable end and bus interface to the next FieldBusPlug) the field bus-neutral interface to the terminal device Sockets Field bus-neutral interface to the terminal device View from the left Pin assignment for parallel mode: 1 +24 V (standard power supply unit) 2 Digital input (DI 1) 3 0 V (standard power supply unit) 4 Digital input (DI 0) 5 Digital output (DO 0) Pin assignment for serial mode: 1 +24 V (standard power supply unit) 2 Diagnosis pin 3 0 V (standard power supply unit) 4 Serial data 5 Serial data Sockets PROFIBUS DP interface. Here, the PROFIBUS DP cable plug of the next FieldBusPlug is plugged in. At the last FieldBusPlug (end of theprofibus DP), this interface is connected to the active bus-line terminator PDR11. Pin assignment: 1 +24 V DC (brown) Caution: 2 Bus-N = A (green) False polarity 3 0 V DC (blue) or reversal between 4 Bus-P = B (red) bus lines and 5 Shield power supply lines can cause a destruction of the FieldBusPlug! PROFIBUS DP plug at the cable end, to previous FieldBusPlug or to bus master PROFIBUS DP plug of the next FieldBusPlug Pins Fig. 3: PDP21-FBP, connector pin assignment 6 PDP21-FBP

Indicators and operating elements on the front plate The following figure shows the indicators and operating elements on the front plate. H1 and H2 display the status of the connection to the PROFIBUS H3 and H4 display the status of the connection to the terminal device PROFIBUS status Fastening screw (provided on delivery) Label for writing down the address setting (provided on delivery) Terminal device status Meaning of the LEDs Connection Connection to to the bus the term. device Status / Cause green red green red LED H1 LED H2 LED H3 LED H4 off off off off Power supply is missing. flashes flashes Plug is under self-test. flashes off Plug is waiting for configuration data, to be sent from the terminal device (number of input/output bytes, number of parameter bytes, data rate etc.). Note: If no data has been sent by the terminal device within 2 seconds, the plug switches to the parallel mode. on off The connection to the terminal device works properly. off flashes Error: can be remedied, e.g. connection to the terminal device is broken. off on Error: cannot be remedied, e.g. incorrect checksum in the flash, exchange plug. on off Normal data exchange on flashes Error: Plug is ready for operation, but it is not accessed by the bus master or the configuration, sent by the bus master, is not equal to the configuration of the terminal device. The terminal device is blocked, if an other type of a terminal device is connected instead of that, which is configured in the bus master. flashes on Error: The terminal device parameters, received from the bus master, are formal incorrect, e.g. of other length or inconsistent contents. No forwarding. Note: The plug forwards formal correct terminal device parameters to the terminal device, without checking them for a correct content. Terminal devices, which can be parameterized, do not start without valid parameters and indicate this error via the diagnosis pin 2 and the red LED on the terminal device. off flashes Error: The plug did not receive any data from the bus within the monitoring time, e.g. because the data line was broken. The monitoring time is set by the bus master. Fig. 4: PDP21-FBP, indicators and operating elements on the front plate PDP21-FBP 7

Technical data Supply voltage 24 V DC +30 % / 20 % Current consumption (without terminal device) at 19.2 V 44 ma at 24.0 V 37 ma at 31.2 V 30 ma Mounting on the terminal device, fixed with a screw (provided on delivery) or by M12 box nut fixing Building of a PROFIBUS DP bus line by connecting the FieldBusPlugs in series (first bus plug to coupler/master, second bus plug to socket of the first FieldBusPlug, etc.) Bus termination active bus-line terminator 150 Ω at both ends of the bus, the bus master units (or repeaters) often offer a bus-line terminator at the start of the bus line. Modes of data communication between FieldBusPlug and terminal device parallel and serial Scope of data according to PROFIBUS-DP specifications Electrical isolation / test voltage between PROFIBUS DP and terminal device yes, 500 V DC Construction of the FieldBusPlug cable round cable, violet, 2 x 0.5 mm 2 for the supply voltage 2 x 0.22 mm 2 for the data lines 2 shields PROFIBUS pin assignment 1 +24 V DC (brown) 2 Bus-N = A (green) 3 0 V DC (blue) 4 Bus-P = B (red) 5 Shield Load capacity of plugs and cables max. 4 A male female Caution: False polarity or reversal between bus lines and power supply lines can cause a destruction of the FieldBusPlug! Pin assignment of the interfaces see Fig. 3 Degree of protection (see also Fig. 3) IP 65, if M 12 box nut fixing is used at the terminal device (e.g. sensor) IP 20, if mounting is performed using the supplied fastening screw (e.g. for UMC22-FBP) Ambient temperature storage -20...+75 C operation 0...+55 C Dimensions see Fig. 5 Total power dissipation of the unit PDP21-FBP max. 0.89 W Weight plug with cable 0.25 m 0.09 kg plug with cable 0.5 m 0.10 kg plug with cable 1 m 0.13 kg plug with cable 5 m 0.35 kg Bus address setting - with address switches on the terminal device (if existing) - with addressing set (interface device + PC + SW) Possible addresses 1 to 126 (recommended 3 to 125), the addresses 0...2 and 127...128 are reserved and should not be used for slaves. Diagnosis (see Fig. 4) 4 LEDs on the front plate LED green, LED red status of the connection to the PROFIBUS LED green, LED red status of the connection to the terminal device 8 PDP21-FBP

Ordering data A fastening screw, an address label and a terminal cap for the bus are supplied along with the FieldBusPlug. Type Description Order number PDP21-FBP.025 PROFIBUS DP FieldBusPlug, cable length 0.25 m 1SAJ 240 000 R0003 PDP21-FBP.050 PROFIBUS DP FieldBusPlug, cable length 0.5 m 1SAJ 240 000 R0005 PDP21-FBP.100 PROFIBUS DP FieldBusPlug, cable length 1 m 1SAJ 240 000 R0010 PDP21-FBP.500 PROFIBUS DP FieldBusPlug, cable length 5 m 1SAJ 240 000 R0050 Accessories Type Description Order number PDX11-FBP.100 PROFIBUS DP extension cable, length 1 m 1SAJ 924 001 R0010 PDX11-FBP.300 PROFIBUS DP extension cable, length 3 m 1SAJ 924 001 R0030 PDX11-FBP.500 PROFIBUS DP extension cable, length 5 m 1SAJ 924 001 R0050 PDF11-FBP.050 PROFIBUS DP round cable, female plug attached at 1SAJ 924 002 R0005 one end, 0.5 m, sheath partially removed, wire-end ferrules attached PDM11-FBP.050 PROFIBUS DP round cable, male plug attached at 1SAJ 924 003 R0005 one end, 0.5 m, sheath partially removed, wire-end ferrules attached PDC11-FBP.999 PROFIBUS DP round cable on 100 m coil 1SAJ 924 004 R1000 PDM11-FBP.0 PROFIBUS DP male connector for round cable 1SAJ 924 005 R0001 PDF11-FBP.0 PROFIBUS DP female connector for round cable 1SAJ 924 006 R0001 PDR11-FBP.150 PROFIBUS DP active bus-line terminator 1SAJ 924 007 R0001 CAS21-FDP.0 Addressing set for DeviceNet, PROFIBUS etc. 1SAJ 929 003 R0001 CAL11-FBP.0 Address label for FielBusPlug (400 pieces) 1SAJ 929 005 R0001 PDP21-FBP 9

Mechanical dimensions All dimensions in mm Fig. 5: PDP21-FBP, mechanical dimensions 10 PDP21-FBP

Manual No. 2CDC 192 001 D0202 ABB STOTZ-KONTAKT GmbH Eppelheimer Straße 82 Postfach 101680 69123 Heidelberg 69006 Heidelberg Germany Germany Telephone +49 6221 701-0 Telefax +49 6221 701-240 E-Mail desst.helpline@de.abb.com Internet http://www.abb.de/stotz-kontakt