HART UNIVERSAL TEMPERATURE TRANSMITTER

Similar documents
HART UNIVERSAL TEMPERATURE TRANSMITTER

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

UNIVERSAL TEMPERATURE TRANSMITTER

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

/8 DIN Universal Process Indicator

Wall-/Pipe Mounted Universal Process Indicator

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

PC CONFIGURATOR Model: 27HUCFG. Users Manual , Minamitsumori, Nishinari-ku, Osaka JAPAN Tel: Fax:

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

Model B3HU. PC CONFIGURATOR Model: B3HUCFG. Users Manual

C160 Wall-/Pipe Mounted Universal Process Indicator

For 2-wire Universal Temperature Transmitter B6U. PC CONFIGURATOR Model: B6UCFG. Users Manual

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

HART Field Device Specification PR 5437 Device Revision 2

Multi-functional precision thermometer CTR3000

/8 DIN Motorized Valve Controller

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

100mm Process Indicator Recorder

Intrinsically Safe Temperature Concentrator System

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

SX90 Process Controller

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3664, EP-3704, EP GFK-2960F September 2018

Portable Multi-Function Calibrator Model CEP6000

Strip Chart Recorders Specification Sheet

Threaded thermocouple Miniature design Model TC10-D

RSTI-EP Slice I/O. Analog Input Modules `EP-3164, EP-3264, EP-3124, EP-3368, EP-3468 EP-3704, EP GFK-2960B November 2017

Programming unit VIATOR HART modems Model PU-H

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

THM501 PT100 MODBUS TEMPERATURE TRANSMITTER

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

itemp TMT180 Technical information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Interface technology and switching devices

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Terminal Block Catalog Numbers 1719-TB6, 1719-TB6S, 1719-TB8, 1719-TB8S, 1719-TB8Sx2, 1719-TB8x2

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

HART 7.x Field Device Specification for STT700 SmartLine Temperature Transmitters Document Number: 34-TT Revision: 1.0 Release: June 2017

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Inform IT Single Pen Circular Chart Recorder

Resistance thermometer With spring-loaded tip Model TR55

LAUREL ELECTRONICS, INC.

Intrinsically Safe Barriers

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

MTL830 SERIES. Cuts installation and cable costs for all IS hazardous-area circuits

MCR-T-UI-NC. Extract from the online catalog. Order No.:

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

IN-uP4 Universal Input Indicator.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

YTA Series Temperature Transmitters

Threaded resistance thermometer Miniature design Model TR10-D

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

DINALOG A 144 x 36 A1400 Light-Strip Indicator

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

masibus : UT-94 Page 1 of 6 INTRODUCTION SPECIFICATIONS Dimensions Document Ref No. m98a/om/101 Issue No: 08

Reed sensor For bypass level indicators Model BLR

3500/65 16-Channel Temperature Monitor

IN-uP4 (Rev 1) Universal Input Indicator, Panel Mount.

M3S Series Super-space-saving Signal Conditioners. PC CONFIGURATOR SOFTWARE Model: M3SCFG. Users Manual

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

JUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN

MCX II. Druck Portable Documenting Calibrator. GE Sensing. Features. Applications

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

HAKKO FG-101 Calibration Instructions Revision

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Transducers & Transmitters HART USERS MANUAL. GP:50 New York LTD Long Road Grand Island, NY USA

-Camille Bauer Div. of Absolute Process Instruments, Inc. Phone: Fax: J-1

TORRIX-HART. Technical Documentation. The magnetostrictive level sensor with HART Protocol. Edition: Version: 5 Article no.

Electromagnetic Flowmeter ProcessMaster, HygienicMaster FEX300, FEX500

Druck DPI 620 advanced modular calibrator

Accessories Fieldbus Box

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

iologik 4000 Series (M) Modules

The CAL range of temperature controllers

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

microblox I/O Modules w/ Bluetooth Wireless Technology Introduction to the microblox Module Family

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

MLC 9000 Bus Compatible PID

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PHOENIX CONTACT - 01/2008

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

S-series Electronic Marshalling

Interface technology. Interface technolog. Interface technology INTERFACE TECHNOLOGY. Sense it! Connect it! Bus it! Solve it!

Sanitary PT100 Temperature Sensors

Transcription:

SEM310 / SEM310X HART 5,6,7 COMPATABLE UNIVERSAL INPUT, DUAL CHANNEL ATEX & IEC Ex Version MATHS FUNCTIONS SENSOR CHARACTERISTICS DOWNLOAD VIA USB PORT ALLOWS FOR CUSTOM TYPES FLASH TESTED TO 4 KV DC INTRODUCTION The SEM310 is a HART 5,6, or 7 compatible universal transmitter. It accepts RTD, Thermocouple, Potentiometer or millivolt input signals and converts them to the industry standard (4 to 20) ma transmission signal. Alternatively HART multidrop mode can be selected. The SEM310 is programmed using a standard USB lead. The ATEX / IECEx version (SEM310X) is programmed with a ATEX / IECEx approved communication lead (USBX Config). Both versions use our free configuration USBSpeedlink software downloaded from our web site. Standard features can also be programmed using HART communication. ENHANCED FEATURES Some of the enhanced SEM310 features are as follows; SENSOR REFERENCING The SEM310 sensor referencing via the Windows based USBSpeedlink software allows for close matching to a known reference sensor eliminating possible sensor errors. USER CALIBRATION In addition to sensor referencing, user offset and current output trimming is possible via the USB and HART commands. CUSTOM LINEARISATION The SEM310 can be programmed with a custom linearization to suit nonstandard sensors or sensors with unusual or unique characteristics. Consult the sales office for details. SENSOR BURN OUT DETECTION If a sensor wire is broken or becomes disconnected the SEM310 output will automatically go to its user defined level (upscale or downscale) or pre-set value. OUTPUT CURRENT PRESET For ease of system calibration and commissioning the output can be set to a pre-defined level anywhere within the (4 to 20) ma range. Hart Registered trademark of the HART Communication Foundation. Page 1 of 5

SPECIFICATIONS @20 C ELECTRICAL INPUT Range + Options Accuracy Stability Resistance (10 to 10000) Ω Excitation 200 ua Lead resistance (0 to 20) Ω (10 to 500) Ω ± 0.055 Ω, (500 to 2500) Ω ± 0.5 Ω, (2500 to 10500) Ω ±0.15 % of reading (0 to 500) Ω 0.013 Ω/ C, (500 to 2500) Ω 0.063 Ω/ C, (2500 to 10500) Ω 0.27 Ω/ C (2,3 or 4 Wire connection) (+ Lead error on 2 wire) Slide Wire (0 to 100) % Travel Wire resistance (1 to 100) KΩ ± 0.1 % ±0.001%/ C mv (-205 to 205) mv DC (-1000 to 1000) mv DC ±0.02 mv ±10.0 mv ±0.005 mv/ C ±0.02 mv/ C SENSOR INPUT RTD (Single/ 2 wire Dual Channel; isolated tip only for Dual operation) Pt100 (IEC) (-200 to 850) C 0.2 C ± ( 0.05% of reading) Pt500 (IEC) (-200 to 750) C (Plus sensor) Pt1000 (IEC) (-200 to 600) C Ni100 (-60 to 180) C Ni120 (-80 to 260) C Ni1000 (-60 to 180) C Cu53 (-50 to 180) C Cu100 (-80 to 260) C Cu1000 (-80 to 260) C Library more (standards/types) Including silicon sensors Thermocouple (Single/Dual Channel; isolated tip only for Dual operation) K (-200 to 1370) C ±0.1 % of full scale ± 0.5 C J (-100 to 1200) C N (-200 to 1300) C E (-200 to 1000) C T (-200 to 400) C ±0.2 % of full scale ± 0.5 C R (0 to 1760) C ±0.1 % of full scale ± 0.5 C S (0 to 1760) C over range (800 to 1760) C L (-100 to 600) C ±0.1 % of full scale ± 0.5 C U (0 to 600) C B (-200 to 1300) C C (0 to 2300) C D (0 to 2300) C G 0 to 2300) C Library contains more (standards/types) DUAL CHANNEL OPERATION Thermocouples A & B mv A & B RTD A & B Functions; Average, Redundancy, A + B, A B, Highest, Lowest Functions; Average, A + B, A B, Highest, Lowest Two wire connection. Functions; Average, A + B, A B, Highest, Lowest Page 2 of 5

AMBIENT SENSOR (Cold Junction) Thermistor 10K Beta 3380 (-40 to 85) C ±0.2 C ±0.05 C/ C OUTPUT Type\options Range Accuracy/Stability/Notes Two wire current (4 to 20) ma (ma Out/ 2000) or 5 ua whichever is the greater, Drift 1 ua/ C User set minimum current (3.5 to 4.0) ma 3.8 ma default User set maximum current (20 to 23.0) ma 20.5 ma default User set error current (3.5 to 23.0) ma User Pre-set current (20 to 23.0) ma For diagnostics Current loop off 3.5 ma Hart multi-drop communications Loop effect ± 0.2 ua/v Loop supply 10 to 30 V DC SELV Max load [(V supply 10)/20) K Ω 700 Ω @ 24 V DC Protection Reverse and over voltage USB USER INTERFACE Approved USB configuration lead required for SEM310X USB 2.0 Mini B USB Approved configuration lead SEM310X USB powers device for config Only. Power loop for live data. Baud Rate 38,400 Sensor configuration Sensor type Profiler configuration Sensor offset Sensor fail high or low Pre-set sensor value Set damping Set No. wires resistance Input Set fixed or auto cold junction Set profiler input range Set profiler segments Enter profile X~Y values Set profiler output units Set the output process range TC & RTD input only set units TC/mV/RTD/Ohms/Slide wire Dual TC/mV/RTD Dual use separate offsets Dual Share sensor fail For diagnostics 2, 3 or 4 wire In sensor units (4 to 22) segments Profiler set up Output signal Select the process range for retransmission Set minimum current Set maximum current Set the error current Trim 4.0 ma signal Trim 20 ma signal Pre-set Loop current Turn loop current off Set in profiler out units (3.5 to 4.0) ma (20 to 23.0) ma (3.5 to 23.0) ma (3.8 to 4.5) ma (19.5 to 20.5) ma 3.5 ma Damping User set PV damping 1 to 32 seconds to reach 70% of final value Page 3 of 5

USB USER INTERFACE Continued HART information Read/write tag number Read/write tag date Set polling address Read/write description Read/write message Read/write final assembly number Read/write long tag Read and set RTC Read HART version HART specification Type\Function\options Type HART Protocol 1200 baud FSK Version Hart 5 to 7 compatible Universal commands Additional universal commands Common practice commands Read manufacturers ID Read short ID Read HART revision Read device revision Read software revision Read hardware revision Read unique ID Read No. pre-ambles Read maximum No. variables Read No. of configuration changes Extended device status Extended manufacturers ID Extended distributes ID Device profile Device ID1, ID2 & ID3 1.Read primary variable (PV) 2.Read loop current and percentage of range 3.Read dynamic variables and Loop current 7.Read loop configuration 8.Read dynamic variable classifications 9.Read device variables with status 12.Read message 13.Read tag, descriptor and date 14.Read primary variable transducer Information 15.Read device information 16.Read final assembly number 17.Write message 18.Write tag, descriptor and date 19.Write final assembly number 20.Read long tag 22.Write long tag 38.Reset configuration changed flag 48.Read additional device status 0. Read unique ID 6. Write polling address 11. Read unique ID associated with tag 21. Read unique ID associated with long tag 34. Write PV damping value 35. Write PV range 40. Enter/exit fixed current mode 41. Perform self-test 42. Perform device reset 44. Write PV units 45. Trim loop current zero 46. Trim loop current gain 49. Write primary variable transducer serial number 71. Lock device 76. Read lock device state Page 4 of 5

Diagnostics Read (PV, ma, ambient C, error & power off) logs points back from device Up to 150 points Log Rate (1 to 60) readings per hour Set the log period Clear log and start new log Export log data Detect open circuit sensor wire Cal date, certificate number, calibrated by Live Data Read sensor signal Read profiler input signal Read profiler output signal Read ambient temperature Read % output Read ma output GENERAL Function Isolation Reading update Response time Warm up Start-up time Flash tested 5 Seconds 4 KV DC, working voltage 50 V AC 200 ms 500 ms to reach 70% final value 2 minutes 5 seconds AMBIENT Function Temperature Operating/Storage (-40 to 85) C Humidity Operating/Storage (10 to 95) % Non-condensing Protection >= IP65 CONNECTIONS Output Screw terminals (1 to 2) Input Screw terminals (3 to 6) USB Mini USB for SEM310, approved configuration lead for SEM310X APPROVALS EMC ATEX IECEx MECHANICAL Enclosure Material Dimensions Weight Fixing centres Centre hole Colour BS EN 61326 Industrial Ex ia IIC T4 Ga Ex ia IIIC T135 Da Ex ia T4 Ga Ex ia IIIC T135 Da DIN standard size terminal block ABS flammability UL94-VO 44 mm diameter 24 mm height Approximately 43 g 33 mm 6.3 mm Black SEM310, Blue SEM310X ORDER CODE SERIES SEM310 SEM310X Status Instruments Ltd Tel: +44 (0)1684 296818 Status Business Park Fax: +44 (0)1684 293746 Gannaway Lane, Tewkesbury Email: sales@status.co.uk Gloucestershire, UK Website: www.status.co.uk GL20 8FD D2579-01-02 SEM310/310X Data Sheet