Multilin EPM 4600 Metering Solution

Similar documents
GE Digital Energy Multilin EPM 4600 Quickstart Guide TELEPHONE: FAX: HOME PAGE:

Doc# E V.1.02 QS - 1

A1. Multilin EPM 4600 Meter Displays DIS3500/DIS5700. Quick Start Guide. GE Digital Energy

Instruction Manual. Multilin TM 8 Series Retrofit Kit * A1* GE Grid Solutions LISTED

PowerLogic ION7300 Series

MM300 Motor Management System Firmware Version 1.71 Update Release Notes

PowerLogic High Density Metering System 1-Meter Enclosure

Copyright 2016 GE Multilin Inc. All rights reserved. EnerVista Integrator Quickstart Guide for version 8.0x. EnerVista, Integrator, POWER LEADER,

Panduit Basic Rack PDU

Multilin 650 Family. Firmware v7.60, Software v7.60 Release Note. GE Grid Solutions. Summary

MM300 Motor Management System

MU110-6U. Analog output module 6 channel. User guide

Panduit Basic Rack PDU with Local Meter

SEM3 - Embedded Micro Metering Module

Model 2380 Rack-Mount Kit

TRC-190 User s Manual

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

Model 2380 Rack-Mount Kit

Multilin EPM 6010 YEAR. GE Grid Solutions. Building Automation Power Meter with BacNET /IP Communications. Monitoring & Metering

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

G5 PDU Installation Guide

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

HID. GE Consumer & Industrial Multilin. High Impedance Differential Module Instruction manual GEK Copyright 2005 GE Multilin

Instruction Manual: IM E

Installation Instructions & User Manual

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

3700 SERIES USER MANUAL

C30. Controller System. Instruction Manual AF2. GE Grid Solutions. Product version: 7.6x GE publication code: AF2 (GEK A)

DM3058/DM3058E Digital Multimeter

TRC-190 User s Manual

750/760 Feeder Management Relay Instruction Manual

PowerLogic ION7550 RTU option

3300 ACM. Installation & Operation Manual. Economical Digital Power Meter/Transducer CONTENTS

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4450GTX-HT- PWR+

RGM180 Display Series

EM QUICK START GUIDE. Quick Start Guide EM BG0504 REV.A2

Wiring Section 3-3. NQ-Series communication ports support various types of (serial) communication.

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

PS/IO Circuit Board Retrofit

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Preparing to Install the VG248

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

5504 Thermocouple Analog Input Module

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Technical Specificaions. kwh Energy Meter

Technical Specifications. Dual Source kwh Energy Meter

PowerLogic ION7300 series Power and energy meter

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Ground Fault Protection. Instruction Manual

GE Grid Solutions. Instruction Manual. GE Energy Aggregator revision: 4.2 GE publication code: GEK Manual Part Number: A1

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

5502 Differential Analog Input Module

I/O SIGNAL CONDITIONER

Checker is the sensor. CheckMate is the software that runs on your PC. You use CheckMate to set up Checker mm mm 4.

5403 and 5404 Digital Input Modules

InnoMedia Business VoIP ATA Models

OilCop Component Wiring Installation Manual

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

Multilin EPM 7000/7000T Power Quality Meter

Installing the Cisco AS5400XM Universal Gateway

Optical Multiplexer. Quick Start Guide

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

ACCESS 9340/9360 Meter Input/Output Module

PM Series Power Meter

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

EnerSure Installation Guide

Technical Specifications. Multi Function Meter

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

Power Supply Installation

EPM g Energy. Multilin BUILDING AUTOMATION POWER METER. BACnet /IP Communications and Energy Measurement KEY BENEFITS APPLICATIONS FEATURES

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

Agilent Technologies E5385A 100-Pin Probe

* * Agilent Power Distribution Unit (PDU) Installation Guide

Multi Unit Enclosed Meter

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

UniStream HMI Panel. CPU-for-Panel

Installation Job Aid for Ethernet Routing Switch 5900 Series

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

General Specifications. P2-SCM Serial Communications

Economy Single Channel Output DC Power Supply

PDU Branch Current Monitoring Board Installation and Configuration

AI130 AIswitch Series 130 Chassis Installation Guide

9200 Power Meter. Installation & Operation Guide

Installation Guide SMT 2200/3000 VA Input/Output Hardwire Kit

Galaxy Shore Connection 500 kva. Operation 04/

Installation Job Aid for Ethernet Routing Switch 3600 Series

Sidewinder Pumps Inc. AC C1D2 Timer/Controller

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Installing and Configuring Rialto Analytic Appliances

PRO-1250D CT MID DIN rail three phase four wire energy meter.

USER S GUIDE Programmable DC Power Supply Model IT6322

Transcription:

GE Digital Energy Multilin EPM 4600 Metering Solution Multi-feed Power and Energy Metering Solution Quick Start Guide GE publication code: 1601-0297-A2 (GEK-119590A) 1601-0297-A2

Copyright 2014 GE Multilin Inc. All rights reserved. Multilin EPM 4600 Instruction Manual for version 1.0x. Multilin EPM 4600 Metering Solution, EnerVista, Digital Energy, Multilin, and GE Multilin are trademarks or registered trademarks of GE Multilin Inc. The contents of this manual are the property of GE Multilin Inc. This documentation is furnished on license and may not be reproduced in whole or in part without the permission of GE Multilin. The manual is for informational use only and is subject to change without notice. Part number: 1601-0297-A2 (February 2014)

Multilin EPM 4600 Table of contents 1 INTRODUCTION GENERAL SAFETY PRECAUTIONS...1 Safety symbols and definitions...3 For further assistance...4 2 MECHANICAL INSTALLATION Recommended Tools...5 Installation...7 3 ELECTRICAL INSTALLATION Electrical Installation...9 4 METERING SYSTEM CONFIGURATION Connecting to the EPM 4600...15 Configuring the EPM 4600...18 Communications Settings...20 Updating the Device Configuration...22 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE iii

TABLE OF CONTENTS iv EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

Multilin EPM 4600 Chapter 1: Introduction Introduction For further product details and safety considerations, refer to the EPM 4600 Instruction Manual, part number 1601-0296. GENERAL SAFETY PRECAUTIONS Failure to observe and follow the instructions provided in the equipment manual(s) could cause irreversible damage to the equipment and could lead to property damage, personal injury and/or death. Before attempting to use the equipment, it is important that all danger and caution indicators are reviewed. If the equipment is used in a manner not specified by the manufacturer or functions abnormally, proceed with caution. Otherwise, the protection provided by the equipment may be impaired and can result in Impaired operation and injury. Caution: Hazardous voltages can cause shock, burns or death. Installation/service personnel must be familiar with general device test practices, electrical awareness and safety precautions must be followed. EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 1

GENERAL SAFETY PRECAUTIONS INTRODUCTION Before performing visual inspections, tests, or periodic maintenance on this device or associated circuits, isolate or disconnect all hazardous live circuits and sources of electric power. Failure to shut equipment off prior to removing the power connections could expose you to dangerous voltages causing injury or death. All recommended equipment that should be grounded and must have a reliable and un-compromised grounding path for safety purposes, protection against electromagnetic interference and proper device operation. Equipment grounds should be bonded together and connected to the facility s main ground system for primary power. Keep all ground leads as short as possible. At all times, equipment ground terminal must be grounded during device operation and service. In addition to the safety precautions mentioned all electrical connections made must respect the applicable local jurisdiction electrical code. Before working on CTs, they must be short-circuited. To be certified for revenue metering, power providers and utility companies must verify that the billing energy meter performs to the stated accuracy. To confirm the meter s performance and calibration, power providers use field test standards to ensure that the unit s energy measurements are correct. 2 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

INTRODUCTION SAFETY SYMBOLS AND DEFINITIONS Safety symbols and definitions Before attempting to install or use the device, review all safety indicators in this document to help prevent injury, equipment damage, or downtime. The following safety and equipment symbols are used in this document. Indicates a hazardous situation which, if not avoided, will result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in death or serious injury. Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. Indicates practices not related to personal injury. EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 3

FOR FURTHER ASSISTANCE INTRODUCTION For further assistance For product support, contact the information and call center as follows. Have your software key(s) ready. GE Digital Energy 650 Markland Street Markham, Ontario Canada L6C 0M1 Worldwide telephone: +1 905 927 7070 Europe/Middle East/Africa telephone: +34 94 485 88 54 North America toll-free: 1 877 547 8629 Fax: +1 905 927 5098 Worldwide e-mail: multilin.tech@ge.com Europe e-mail: multilin.tech.euro@ge.com Website: http://gedigitalenergy.com/multilin 4 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

Multilin EPM 4600 Chapter 2: Mechanical Installation Mechanical Installation Recommended Tools Recommended tools for EPM 4600 installation: #2 Phillips screwdriver 1/4-inch (0.250 ) nut driver socket, box, or open-end wrench wire cutters The EPM 4600 unit is designed to withstand harsh environmental conditions; however it is recommended you install it in a dry location, free from dirt and corrosive substances EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 5

RECOMMENDED TOOLS MECHANICAL INSTALLATION 7.60in 3.03in 193.1mm 76.9mm 0.19in 4.8mm 0.80in 20.4mm 4.50in 114.3mm 0.12in centered 2.9mm 10.98in 278.9mm centered 11.28in 286.5mm 0.28in 7.2mm 6 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

MECHANICAL INSTALLATION INSTALLATION Installation To install the EPM 4600 Unit: 1. Mount the unit against any firm, flat surface. 2. Use a #8 screw in each of the four slots on the flange to ensure that the EPM 4600 unit is installed securely. For safety reasons, mount the EPM 4600 unit in an enclosed and protected environment, such as in a switchgear cabinet. Connect an earth ground to the post on the side of the EPM 4600 unit, using an AWG 12 wire. Install a switch or circuit breaker nearby; label it clearly as the EPM 4600 unit s disconnecting mechanism. 3.18in 80.6mm 4.36in 110.6mm 0.81in 20.5mm 7.62in 193.5mm EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 7

INSTALLATION MECHANICAL INSTALLATION 8 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

Multilin EPM 4600 Chapter 3: Electrical Installation Electrical Installation Electrical Installation All Primary and Secondary circuits can, at times, produce lethal voltages and currents. Avoid contact with any current-carrying surfaces. The current inputs are only to be connected to external current transfomers (CTs). EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 9

ELECTRICAL INSTALLATION ELECTRICAL INSTALLATION SERVICES: WYE, 4 WIRE. CONNECTION TYPE: Direct Voltage, CTs 3 N 1 2 LINE C B A N CT Shorting Block I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Earth Ground Only one 3 phase circuit is shown. Duplicate for additional circuits. C FUSES 3 x 0.1A Earth Ground B A N FUSE 3A L(+) N(-) Power Supply Connection LOAD Service: Three Phase, 4-Wire WYE Service Direct Voltage and 3 CT Connection for Metering 8 Three Phase Loads: EPM 4600-T All CTs must have one side grounded to reduce shock hazard. GE Digital Energy highly recommends using shorting blocks so that the meter can be removed from service while the CT is energized. 10 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

ELECTRICAL INSTALLATION ELECTRICAL INSTALLATION SERVICES: WYE, 4 WIRE. 3 CONNECTION TYPE: 3PTs, CTs N 1 2 LINE C B A N CT Shorting Block I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Earth Ground Only one 3 phase circuit is shown. Duplicate for additional circuits. C FUSES 3 x 0.1A Earth Ground B A N FUSE 3A Earth Ground L(+) N(-) Power Supply Connection LOAD Service: Three Phase, 4-Wire WYE Service with 3 PT Voltage and 3 CT Connection for Metering 8 Three Phase Loads: EPM 4600-T All CTs must have one side grounded to reduce shock hazard. GE Digital Energy highly recommends using shorting blocks so that the meter can be removed from service while the CT is energized. EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 11

ELECTRICAL INSTALLATION ELECTRICAL INSTALLATION SERVICES: SINGLE PHASE, 2-WIRE CONNECTION TYPE: Direct Voltage, CTs N 1 LINE VL N CT Shorting Block I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Earth Ground Only three circuits are shown. Duplicate for additional circuits. Earth Ground VL N Short Voltage inputs together FUSE 3A L(+) N(-) Power Supply Connection LOADS Service: Single Phase, 2-Wire Service with Direct Voltage and 1 CT Connection for Metering 24 Single Phase Loads: EPM 4600-S All CTs must have one side grounded to reduce shock hazard. GE Digital Energy highly recommends using shorting blocks so that the meter can be removed from service while the CT is energized. 12 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

ELECTRICAL INSTALLATION ELECTRICAL INSTALLATION SERVICE: SINGLE PHASE, 3-WIRE CONNECTION TYPE: Direct Voltage, CTs To monitor 24 individual loads. See accuracy table for limiting factors. N 2 1 LINE VL1 VL2 N CT Shorting Block Run lines VL1 and VL2 through the CT in opposite directions Set PT ratio to half in the meter. VL2 VL1 I1-LO I1-HI I2-LO I2-HI I3-LO I3-HI Earth Ground Only one circuit is shown. Duplicate for additional circuits. Earth Ground VL1 FUSES 2 x 0.1A Short Voltage inputs together FUSE 3A VL2 L(+) N(-) Power Supply Connection LOADS Service: Single Phase, 3-Wire Service with Direct Voltage and 1 CT Connection for Metering 24 Single Phase Loads: EPM 4600-S All CTs must have one side grounded to reduce shock hazard. GE Digital Energy highly recommends using shorting blocks so that the meter can be removed from service while the CT is energized. EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 13

ELECTRICAL INSTALLATION ELECTRICAL INSTALLATION 14 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

Multilin EPM 4600 Chapter 4: Metering System Configuration Metering System Configuration Connecting to the EPM 4600 To configure the EPM 4600 Metering System: 1. Connect to the EPM 4600 unit through the USB port: Use a USB Type A to B plug to connect from your PC USB port to the EPM 4600 unit s USB port. If your PC doesn t automatically find the USB driver, download it from the product CD that came with the EPM 4600 unit (see Chapter 12 in the EPM 4600 Instruction Manual on the enclosed CD). EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 15

CONNECTING TO THE EPM 4600 METERING SYSTEM CONFIGURATION Note that this EPM 4600 Quickstart Guide shows connection using the USB port only. For Ethernet/Wifi or RS485 connection, see the EPM 4600 Instruction Manual. USB Port 2. Open the GE Communicator software (download from product CD). 16 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

METERING SYSTEM CONFIGURATION CONNECTING TO THE EPM 4600 3. Click Connect on the tool bar. You will see the Connect screen. Make sure the Address, Baud Rate, and Protocol settings match the ones shown here. 4. Click Connect - the Device Status screen confirms the connection. 5. Click OK - the GE Communicator main screen opens. EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 17

CONFIGURING THE EPM 4600 METERING SYSTEM CONFIGURATION Configuring the EPM 4600 1. Click the Profile button on the tool bar. The Device Profile screen opens. The Tree menu on the left side of the screen lets you choose setting screens. 2. Click System Settings to open one of the following two screens which differ for the three-phase EPM 4600-T and single-phase EPM 4600-S. Use this screen to name the EPM 4600 unit (CPU) and to label the circuits (individual meters). You must give the EPM 4600 CPU an individual, unique name to properly download data to the database. 18 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

METERING SYSTEM CONFIGURATION CONFIGURING THE EPM 4600 3. Click Communications (see the following section). 4. Click CT, PT Ratios and System Hookup (see the following section). EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 19

COMMUNICATIONS SETTINGS METERING SYSTEM CONFIGURATION Communications Settings COM 1: RS485/ Ethernet/WIFI (optional) Address: 1-247; Baud Rate: 57600; Protocol: Modbus RTU/Modbus ASCII; Response Delay: 0-750ms; Parity: Odd, Even or None COM 2: USB port NOTE: The USB port settings are fixed. COM 3: RS485 Address: 1-247; Protocol: Modbus RTU/ASCII Baud Rate: 9600, 19200, 38400, 57600 Response Delay: 0-750ms NOTE: Click the (1)Default to Ethernet or (2)Default to Display button to set either the (1)Ethernet settings for COM1 or (2)Display settings for COM3, to their default values. 20 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE

METERING SYSTEM CONFIGURATION COMMUNICATIONS SETTINGS CT, PT Ratios and System Hookup Note that the settings you see on the screen depend on your EPM 4600 unit s circuit configuration. The top screen is for an EPM 4600 unit with the single phase circuit configuration (EPM 4600-S). The bottom screen is for an EPM 4600 unit with the three phase circuit configuration (EPM 4600-T). For PT settings, see the EPM 4600 Metering System Instruction manual, on the enclosed CD. The CT settings are: CT Ratios CT Numerator (Primary): 1-65535 CT Denominator (Secondary): 10 or 2 Amps, depending on the EPM 4600 unit s ordered option (this field is display only). EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE 21

UPDATING THE DEVICE CONFIGURATION METERING SYSTEM CONFIGURATION Updating the Device Configuration To Update the EPM 4600: 1. When changes are complete, click the Update button to send a new profile to the EPM 4600 unit. 2. Click Cancel to Exit the screen. For further details and additional programming screens, refer to the GE Communicator Instruction Manual on the enclosed CD (access the software manual by clicking Help>Contents from the GE Communicator title bar) 22 EPM 4600 POWER AND ENERGY METERING SOLUTION - QUICK START GUIDE