Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Similar documents
Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Features various encoder interfaces and controls multiple analog servo drives at high speeds

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

Connecting Sockets, Mounting Brackets, DIN Rails

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

S82S (3/7.5-W Models)

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Number of input channels

CJ1W-FLN22 CSM_CJ1W-FLN22_DS_E_3_1

CSM_PYF S/P2RF- -S_DS_E_2_5

NX-TS. NX-series Temperature Input Unit

NJ-Series Power Supply Unit NJ-PA/PD

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Electroformed Probe Pins XP3A

Solid State Relays with Failure Detection Function

Model A7BS

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

CX-One Ver.4 CSM_CX-One_DS_E_8_2

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Indicator (Square) Ultra Bright LED Type

CX-One Ver.4 CSM_CX-One_DS_E_10_2

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

NX-DA CSM_NX-DA_DS_E_3_1

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

M16-J M16-A M16-T

Model Number Structure

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

Model NPN output PNP output Standard. configuration

Indicator (Square) Ultra Bright LED Type

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

SYSMAC CS-series MECHATROLINK-II-compatible Position Control Units

EtherCAT master * Output port CPU Unit

E4C-UDA CSM_E4C-UDA_DS_E_12_2

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

CJ1W-ETN21 CSM_CJ1W-ETN21_DS_E_6_2

CS1W-EIP21 CSM_CS1W-EIP21_DS_E_7_3

Dimension A. Dimension B

NYM. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

Practices Guide OMRON Standard IAG Library

Ordering Information. Interface Converter K3SC. List of Models

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

CSM_NX-PG0 DS_E_4_4

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration

Appendix G. CJ1W-CIF11 RS-422A Converter

CJ1W-FLN22. CJ-series FL-net Unit. Connect to Multivendor Controller Networks. Features

Model Number Structure

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

Analog Input Unit. MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

NPN output. 200 mm. Type Cable length Model Remarks

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Knob-type Selector Switches

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

Classification Applicable models Specification Type Model

CPU Unit. (Temperature control) (Position control) (Speed control)

CJ1W-EIP21 CSM_CJ1W-EIP21_DS_E_9_2

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Smart Sensors with Ultra-High-Speed Color CCD Cameras mm to mm (variable) mm to mm (variable)

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Model Number Structure

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Appendix 3 Using NS-AL002 Converters

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

Machine Automation Controller NJ Series

Model Number Structure

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Model Number Structure

Handheld Reader Writer

Transcription:

SYSMAC Option CSM DS_E_2_1 The RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. The connects directly to a CS/CJ-series RS-232C port and converts RS-232C to RS-422A/485. Features You can use RS-422A/RS-485 by connecting the converter to built-in RS-232C port of the CS/CJ series and the RS-232C connector of the Serial Communications Units (D-Sub,9-pin). Up to 9 nodes can be linked via built-in RS-232C ports of the CJ1M CPU units, using Serial PLC Links function. Ordering Information Name Specifications Model Standards Converts RS-233C to RS-422A/RS-485. UC1, N, L, CE International Standards The standards indicated in the "Standards" column are those current for UL, CSA, culus, cul, NK, and Lloyd standards and EC Directives as of the end of September 2008. (The standards are abbreviated as follows: U: UL, U1: UL Class I Division 2 Products for Hazardous Locations, C: CSA, US: culus Class I Division 2 Products for Hazardous Locations, CU: cul, N: NK, L: Lloyd, and CE: EC Directives. Ask your OMRON representatives for the conditions under which the standards were met. 1

Specifications General Specifications Item Dimensions 18.2 34.0 38.8 mm (W H D) Weight 20 g max. Ambient operating temperature 0 to 55 C Ambient storage temperature 20 to 75 C Ambient operating humidity 10% to 90% (with no condensation) Rated power supply voltage 5V Current consumption 40 ma max. Operating atmosphere No corrosive gases Vibration resistance Same as SYSMAC CS/CJ Series. Shock resistance Same as SYSMAC CS/CJ Series. Isolation method Not isolated Maximum communications distance 50 m Specification (Supplied from pin 6 of the RS-232C connector.) Block Diagram RD SW.6 SDB(+) SDA( ) RS CS SW.5 SW.3 SW.2 SW.1 SD RDB(+) RDA( ) ER DR +5V SG(0V) 2

External Interface RS-232C Connector +5V 6 7 8 SG(0V) 9 Connector Arrangement for RS-232C Port 1 2 3 4 5 RD SD CS RS number 1 2 RD 3 SD 4 CS 5 RS 6 +5V 7, 8 NC 9 SG (0 V) Note: The hood will have the same electrical potential as the connector on the other end of the cable. Hood NC RS-422A/485 Terminal Block Wiring the RS-422A/485 Terminal Block Use either two-wire or four-wire shielded cable. Recommended cable: CO-HC-ESV-3P 7/0.2 (Hirakawa Hewtech) Connect the shield wire at both ends of the cable carrying RS-422A/485 signals to ground, and ground the ground terminal on the Power Supply Unit of the CPU or Expansion Rack to 100 Ω max. 3

Wiring Example (CJ1M CPU Units Connected via Serial PLC Link) CJ1M CPU Unit (master) CJ1M CPU Unit (slave 0) CJ1M CPU Unit (slave 1) CPU Unit's CPU Unit's GR RS-232C port GR RS-232C port GR CPU Unit's RS-232C port Serial PLC Link Note: 1. Connect the shield wire at both ends of the cable carrying RS-422A/485 signals to ground, and ground the ground terminal on the Power Supply Unit of the CPU or Expansion Rack to 100 Ω max. 2. The is not insulated, so the total transmission distance for the whole transmission path is 50 m max. If the total transmission distance is greater than 50 m, use the insulated NT-AL001, and do not use the. If only the NT-AL001 is used, the total transmission distance for the whole transmission path is 500 m max. Wiring for Four-wire Cable CJ1M CPU Unit (Master) 1: ON 2: OFF (4-wire type) 3: OFF (4-wire type) 6: OFF (No RS control for SD.) CJ1M CPU Unit (Slave 0) 1: OFF (No termination resistance.) 2: OFF (4-wire type) 3: OFF (4-wire type) 6: ON (With RS control for SD.) CJ1M CPU Unit (Slave 1) 1: ON 2: OFF (4-wire type) 3: OFF (4-wire type) 6: ON (With RS control for SD.) Shield Wiring for Two-wire Cable CJ1M CPU Unit (Master) 1: ON 2: ON (2-wire type) 3: ON (2-wire type) 6: ON (With RS control for SD.) CJ1M CPU Unit (Slave 0) 1: OFF (No termination resistance.) 2: ON (2-wire type) 3: ON (2-wire type) 6: ON (With RS control for SD.) CJ1M CPU Unit (Slave 1) 1: ON 2: ON (2-wire type) 3: ON (2-wire type) 6: ON (With RS control for SD.) Shield 4

Dimensions (Unit: mm) 5.8 38.8 18.2 34.0 Related Manual Name Cat. Contents SYSMAC CJ Series CJ1H-CPU@@H-R, CJ1G/H-CPU@@H, CJ1G-CPU@@P, CJ1G-CPU@@, CJ1M-CPU@@ Programmable Controllers Operation Manual W393 Provides an outlines of and describes the design, installation, maintenance, and other basic operations for the CJ-series PLCs. 5

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2013.5 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2013 All Right Reserved.