Process Gas Chromatograph

Similar documents
Process Gas Chromatograph

Rosemount TM 700XA Process Gas Chromatograph

700XA Process Gas Chromatograph

700XA Process Gas Chromatograph

MOVING FROM PIPELINE TO PROCESS APPLICATIONS

Danalyzer Model 2350A. Gas Chromatograph Controller

Danalyzer 700XA Gas Chromatograph

Rosemount TM 770XA Natural Gas Chromatograph

Model 700 On-line Gas Chromatograph NATURAL GAS MEASUREMENT - Power, Precision, Reliability

Process Gas Chromatograph PGC1000

ABB Analytical ABB Process Analytics. VistaII. Model 2000 Process Gas Chromatograph

Rosemount 370XA Natural Gas Chromatograph

Parallel Chromatography Valveless Switching

Danalyzer 370XA Natural Gas Chromatograph

Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

Process Gas Chromatograph PGC5000 Series. PGC5000A Master Controller Designed for Reliability and Simplicity

Rosemount 370XA Natural Gas Chromatograph

MicroNet TMR Control System

DeltaV M-series I/O Subsystem Horizontal Carriers

Heat Value Gas Chromatograph ISO standard version

Versatile Transmitter Series For Intelligent Measurement Solutions. INGOLD Leading Process Analytics

3420 Fieldbus Interface Module (FIM) Contents

S-series Foundation Fieldbus I/O

Continuous Dew Measurement in Explosive Area for flammable and non-flammable gases. VASTHI ENGINEERS

2301E ST Steam Turbine Control for Small Generator Applications

DeltaV Bulk Power Supplies

Process Gas Chromatograph Transmitter

SS3000e DUAL CHANNEL H2O GAS ANALYZER KEY FEATURES NEW FEATURES. FOR NATURAL GAS Product Code 10805

MICRO GC FUSION Micro GC Fusion 3/17/2014 1

Product Guide. Repeatable RH and temperature measurement for precise humidity control and validation

DeltaV Bulk Power Supplies

Introduction. Delivers four ports to provide increased input/ output per card. Takes advantage of all smart device capabilities

DMT345 and DMT346 Dewpoint Transmitters

2900 Float & Tape Transmitter

To NeSSi or Not to NeSSi: A Fast and Micro GC Experience Review

TCS. Description. Features. IECEx. Temperature Concentrator System Multi-Channel Transmitter

Brooks Models SLA5850, SLA5851, SLA5853 Mass Flow Controllers and Models SLA5860, SLA5861, SLA5863 Mass Flow Meters

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

NEMA 7. Wireless Technologies USA Witech USA Corp

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

Product Data: Micro MV 100

Soprane II Documentation

700XA Gas Chromatograph

S-series Sequence of Events Card

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

M-series Intrinsically Safe I/O

Type i2p-100 Electro-Pneumatic Transducer

Brooks Models SLA SLA7860 Mass Flow Controllers and Meters

Online data sheet. FLOWSIC100 Flare MASS FLOW MEASURING DEVICES

2910 Float & Tape Transmitter

Vertex. Compressor Control. Applications. Product Specification (Revision B, 3/2018)

Wireless Field Data Backhaul

M-series Foundation Fieldbus I/O

NEMA 4X. Wireless Technologies USA Witech USA Corp

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

S-series DeviceNet Interface Card

powered by TAS Technology

Isotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

HGC Data Manager. Model HDM303 OVERVIEW FEATURES. No. SS2-HDM (Rev.3)

Tracy Dye, CPAC Rome, March 21 24, Miniature Sample Handling and Analytical Techniques Workshop NeSSI Generation 2

M-series I/O Subsystem Horizontal Carriers

S-series Mass Connection Solutions

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

M-series MQ Controller

M-series Serial Interface Series 2

S-series Horizontal Carriers

Roxar SandLog High Accuracy Sand/Erosion Monitoring

Series DiTemp Series SolarTemp. Digital Thermometers

DeltaV Ethernet I/O Card

Dual Duct Controller - One Air Velocity

Self-Powered Wireless Instrumentation

Roxar CorrLog High Accuracy Corrosion Monitoring

Gas-actuated thermometer Stainless steel version Model 73

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

dual-line 6-dIGIt process MeteR

reliable affordable flexible HIGH POWER LRS-9550 LASER DIODE LIFE-TEST AND BURN-IN SYSTEM

Multiphase Flowmeter FlowSys TopFlow Multiphase Meter Operations Manual

LCp-100 Weight Indicator/Transmitter

FBxConnect Configuration Software

CS844 Series: Carbon/Sulfur by Combustion

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Maintenance Manual Edition 10/2012

Online data sheet. FW101 Ex SCATTERED LIGHT DUST MEASURING DEVICES

CONTROL MICROSYSTEMS Analog Input Module. Hardware Manual

Houston Digital Instruments, Inc. Product Catalog

9861 Series. High Temperature Mass Flow Controllers/Meters. Overview. Product Description. Thermal Mass Flow

DeltaV Electronic Marshalling for Migrations

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Thermo Scientific AquaPro Multi-Input Intelligent Process Analyzer

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Consolidated Sterilizer Systems

Flexar FX-20 LC Pump: Ultimate Performance and Flexibility for UHPLC and HPLC

FloBoss TM 107/107E Flow Manager Overview

March 21, Re: Life Cycle Change Notification FloBoss 407 and ROC 300 Series. ROC 300 and 407 Customers,

Dräger Polytron IR. Dräger Polytron IR: Configurable gas detector for reliable detection of combustible gases and vapours.

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

ATS22D17Q soft starter-ats22-control 220V-power 230V(4kW)/ V(7.5kW)

Transcription:

Product Data Sheet PDS 103-700.A01 October 2005 Model 700 Process Gas Chromatograph The Model 700 Process Gas Chromatograph is an advanced combination of technology and rugged instrumentation that helps make the most of existing plant manpower. Today s trend toward downsizing means instrument technicians have more to do in less time. Instrumentation has to be more reliable and easier to use than ever before. Emerson s Rosemount Analytical Process gas chromatographs are your best choice; we ve built our reputation on equipment reliability and long-term performance with ease of use. FEATURES Newest Rosemount Analytical Process Gas Chromatograph offering from Emerson Fully compatible with modern Ethernet networks and DCS communication Designed for fi eld-mounting without the need for expensive analyzer shelters and without sacrifi cing analytical power Diaphragm-based chromatograph valves available in 6-port and 10-port versions Thermal Conductivity Detector (TCD) sensitive down to very low parts-per-million levels Flame Ionization Detector (FID) sensitive to parts-per-billion levels Every Model 700 is rigorously tested in an environmental chamber between 0 to 130 F for 24 hours minimum Last chromatogram for each sample and calibration stream stored in Process Gas Chromatograph Archives up to 254 item averages, more than 3 months of standard runs and calculations APPLICATIONS The Model 700 is designed for a variety of refi ning, petrochemical, food and beverage, pharmaceutical, power and environmental applications where selected components in gaseous or liquid streams must be precisely monitored on a continuous basis. Refineries Catalytic reformer Isomerization unit Aromatics unit Petrochemical Ethylene plants Polymer plants Acrylonitrile plants Gas Processing NGL and LNG plants Cryogenic gas plants Power Generation Power generation plants Gas turbine control Environmental Monitoring Ambient air monitoring HR-VOCs in fl ares and cooling towers The Rosemount Analytical Process Gas Chromatograph Difference Broad application scope with single or dual detector capability Extreme ambient temperature operation minimizes installation and utility requirements High-sensitivity thermal conductivity detectors can often replace the need for more complex detectors Easy-to-use MON2000 software for advanced diagnostics and simplifi ed troubleshooting; simply the best in the industry Rosemount Analytical diaphragm valves offer a lifetime warranty Visit our website at www.raihome.com On-line ordering available.

Gas Chromatograph Valves The chromatograph valves used in Rosemount Analytical Process Gas Chromatographs are unique to the on-line gas chromatograph market. Using a design originally developed by NASA, the valve offers greatly extended operating life. Emerson Process Management is currently the only on-line gas chromatograph supplier to offer a lifetime warranty on their Rosemount Analytical chromatograph valves! Choice 6-port and 10-port, diaphragm valve Simple mechanical design Sample does not come in contact with internal moving parts More than 5 million operations per valve Lifetime warranty Rotary and Liquid Injection Valves also available for special applications The reason for the exceptional durability of the valve is its unique double-diaphragm actuation. The double-diaphragm design eliminates the need for springs, o-rings and lubrication. Flow paths in the valve are arranged so that internal moving parts never contact the sample fl ow. As a result, abrasive mechanical wear on machined valve surfaces is eliminated. The valves are rated for over 5 million operations before repair (approximately 3-5 years of usage). And then, repair is typically simply changing the diaphragms in the valve. For many part-per-million applications, a simple easyto-maintain TCD detector can be used rather than a more complicated FID or FPD due to the superior sensitivity of the Rosemount Analytical TCD design. Most importantly, the Rosemount Analytical valve offers excellent performance. The valve is available in both 6-port and 10-port versions to handle both simple and complex column valve arrangements. Minimal internal movement of the components in the valve - roughly 1/1000th of an inch - contributes to rapid actuation of the valve, which can be important for applications using micro-packed and capillary columns. The diaphragm valve used in the Model 700 is available in both 6-port and 10-port versions for maximum application flexibility. Detectors The Model 700 Process Gas Chromatograph has a selection of detectors to handle a wide range of analytical demands found in typical process applications. Whether the components of interest are in the percent range or down to the parts-per-million range, precise and reliable measurement is possible. TCD detector is sensitive down to 3 ppm Micro-FID detector is sensitive down to the parts-perbillion level Dual TCD / TCD or TCD / FID confi gurations possible Flame Photometric Detector (FPD) Module also available The thermistor TCD is the detector of choice for most applications due to its universal response to all compounds. Emerson's Rosemount Analytical TCD is able to go well beyond the normal measuring ranges seen in other designs by being able to do many applications with low parts-per-million measurement requirements. This greatly simplifi es the process gas chromatograph design when a simple and rugged TCD can be used rather than an FID. For measurement of most organic compounds in the low ppm or even ppb ranges, the Flame Ionization Detector (FID) is an option available for the Model 700. Its micro design is perfect for the transmitter-style enclosure of the Model 700 without sacrifi cing analytical power. An FPD Module is available for trace Sulfur measurement (ppb-level) applications. Page 2

Heat Sink Oven The Heat Sink Oven design of the Model 700 brings stable and precise measurement to the fi eld without the need for expensive analyzer shelters. Airless oven analytical kiosk with oven temperatures up to 100 C Up to 3 six or ten port diaphragm valves for maximum analytical fl exibility Micro-packed columns mounted in the center of the heated kiosk for stable performance over the analyzer s entire ambient temperature rating The Heat Sink Oven of the Model 700 is a triangular shaped solid stainless-steel kiosk that can accommodate up to three chromatograph valves and two detectors. It also contains the chromatograph columns. This unique design, with oven temperatures up to 212 F (100 C), is standard for the Rosemount Analytical Model 700 Process Gas Chromatograph. Columns Since 1980, Emerson Process Management has been refi ning and improving its process for creating micropacked columns. Rosemount Analytical micro-packed columns offer a superior combination of the features found in both capillary and conventional packed columns. The result is improved chromatography with extended column life (several years in most applications without measurable degradation or bleed). Rosemount Analytical micro-packed columns produce sharper peaks for improved component separation, short analysis time and very low carrier-gas consumption. Maintenance of the Model 700 oven is simplified with all components mounted on the surface of the kiosk making access easy. Furthermore, the kiosk is mounted on a rotating plate that can be pivoted out of the way when access to other components is needed. The Design Makes The Difference: Built tough to stand up against any environment Tested tough to insure performance Field-mountable technology means solid performance at reduced cost Valves built so well, they re guaranteed for life! Detector options that meet your requirements Micro-packed columns that are made to last Page 3

MON2000 Software The Model 700 Process Gas Chromatograph is designed to operate unattended. If however, adjustments are needed; our exclusive MON2000 software allows complete control of your gas chromatographs either locally or remotely. From within MON2000, a user can: Review and modify analytical settings Upload and display multiple chromatograms on the screen for comparison Upload and trend any of the measured results Export data for use in other 3rd party applications Overlay multiple chromatograms for troubleshooting and calibration Check original calibration against last calibration The MON2000 Software is Windows -based software designed to make analyzer confi guration, maintenance and data collection easy. With intuitive drop-down menus and fi ll-in-the-blank tables, even new users can quickly navigate through the software. The MON2000 software can display both current and multiple archived chromatograms on the screen streamlining the time needed to perform routine analyzer maintenance. MON2000 also has a number of tools built in that help users manage their analyzers such as: Automatic recording of alarms in a log fi le Event logs that provide a continuous record of all operator changes with time and user name stored Maintenance log scratch pad for keeping track of maintenance or testing done Data collected from the process gas chromatographs can be stored and displayed in a wide range of options such as trend lines on the screen and logs automatically documenting all changes made to the process gas chromatograph. Data can also be exported in formats compatible with most third-party Windows applications. Comparing multiple chromatograms and zooming into specific sections is easy with the point and click design of MON2000. Windows is a registered trademark of Microsoft Corporation Powerful Yet Simple MON2000 Software Simple dropdown menus Connect to any GC with a mouse click Summary of application event status and time Automatic listing of measured components Full featured chromatogram display Quickly add chromatograms to overlay Save CGM's to hard drive Page 4

Analyzer Networking and Data Communication Emerson s Rosemount Analytical Process Gas Chromatographs can be confi gured in a number of networking and data communication schemes to meet most process communication requirements. Options include Ethernet networks as well as multi-drop RS-485 networks. It is even possible to set up automatic polling for data collection over phone lines if desired. Data communication options to the plant control system include simple analog and discrete signals as well as Modbus serial links. To preserve the integrity of the analysis data, all Model 700 Process Gas Chromatographs are capable of storing up to 99 days of analysis data in the event of loss of communication to the plant control system. All Rosemount Analytical Process Gas Chromatographs are designed to operate unattended. Occasionally, adjustments to the analyzers analytical method or a review of possible alarms may be needed. Using our exclusive MON2000 software loaded on either a PC or laptop running Windows, you ll have complete control of your process gas chromatographs - either locally or remotely. Networking Flexibility Whether you want to network process gas chromatographs throughout the plant or simply link a single gas chromatograph to the DCS system, the Model 700 can be confi gured to handle most any scenario: Choice of Ethernet or RS-485 networks Can use the same network to connect Model 700, Model 500 and Model 1000 Process Gas Chromatographs Able to connect multiple PC workstations using MON2000 Connectivity to plant control systems using industry standard protocols such as Modbus and OPC Secure Modbus Connectivity For process gas chromatographs, Modbus continues to be the preferred choice to connect a process gas chromatograph network to the plant control system. Modbus design avoids the use of central interface cards or computers that can act as a single-point of failure in the Modbus link. Instead, the plant DCS system can talk directly to each process gas chromatograph to gather the data needed. Furthermore, the register and coil addresses can be easy customized to meet the specifi c data structure of the DCS. There is also a program built into the MON2000 workstation to test the Modbus link to the DCS if troubleshooting is needed. The main electronics for the Model 700 Process Gas Chromatograph is mounted in a separate lower enclosure for protection of the electronics as well as providing easy accessibility. With Ethernet, analyzers transmit directly to the plant s digital control system (including DeltaV ) quickly and securely using either industry standard Modbus or the new OPC protocol. Page 5

Environmental Chamber Testing Emerson Process Management provides the most thorough process gas chromatograph testing in the world. Each Model 700 must operate to specifi cation in our walk-in environmental test chambers cycling between 0 F and 130 F for 24 hours minimum. This is all part of our commitment to provide process gas chromatographs that are capable of providing reliable measurements in the fi eld. Custom Engineered Sample Systems Any process gas chromatograph is only as good as the quality of the sample it measures. So every sample system for Rosemount Analytical Process Gas Chromatographs is custom engineered for the specifi c requirements of the application. Common features include: Heated and open panel designs All components rated for the area classifi cation Automatic calibration / validation available as an option Variety of sample probes to extract a reliable and stable sample from the process Legendary measurement stability in extreme climates is tested for every Model 700 Process Gas Chromatographs before it ships. 00 350 300 250 200 150 100 50 Lower Installation and Maintenance Cost Rosemount Analytical Process Gas Chromatographs offer some of the lowest cost of ownership in the industry. Most process measurements can be made at or near the sample point greatly reducing the overall lifetime cost of the measurement. Expenses such as shelters, air conditioning, heating, long/heated sample lines can be minimized or completely eliminated in most applications. Furthermore, Rosemount Analytical Process Gas Chromatographs are designed to operate unattended for long periods of time without adjustment. When adjustments are required, all components are easily accessible and can be performed in the fi eld in minutes with standard tools. Page 6

Request A Quotation Every Model 700 Process Gas Chromatograph is custom built for the specifi c application requested. To request a free quotation, simply fi ll out the information below and send it to the address at the end of this data sheet. You can also fi nd an electronic version of the Request For Quotation form at our web site http://www.raihome.com. Name: Title: Company: Address: Your Reference #: Project Name: Process Unit: Stream Name(s): Phone #: Fax #: Email: Hazardous Area Classification: Stream Composition Units Stream 1 Stream 2 Min Normal Max Measure Min Normal Max Measure (For more than two streams, make copies of this page) Stream Temperature: Stream Pressure: Stream Phase (vapor / liquid) Stream Contaminants: Stream 1 Stream 2 Distance to GC from Sample Point: Mounting: Wall ( ) Pipe ( ) Stand ( ) Power: 100-240 VAC ( ) 24 VDC ( ) Data Communication: Analog Output ( ) Modbus ( ) OPC ( ) Printer ( ) Modem ( ) Analyzer Network: Ethernet ( ) RS-485 Multi-Drop ( ) Other Options: Carrier Gas ( ) Calibration Gas ( ) Start-Up ( ) Training Class ( ) Special Instructions: Page 7

4 OR 2 POLE MODEL 700 SPECIFICATIONS Power: Standard: 24 VDC, (23-28 VDC); 80 watts Optional: 90-264 VAC, 47-63 Hz; 80 watts 80 watts start-up; 33 watts nominal Environment: -29 to 60 C (-20 to 140 F) Dimensions (without sample system): Wall-Mount: 914mm H x 462mm W x 483mm D (36 H x 18.2 W x 19 D) Pipe-Mount: 914mm H x 462mm W x 645mm D (36 H x 18.2 W x 25.4 D) Floor-Mount: 1483mm H x 419mm W x 577mm D (58.4 H x 16.5 W x 22.7 D) Mounting: Free-standing (standard) wall- or pipe- mount (optional) Approximate Weight (without sample system): 80 kg (175 lbs.) Area Safety Certification Options: Canada: Class I, Zone 1, Ex d IIB+H2, T4, Enclosure Type 4 USA: Class I, Zone 1, AEx d IIB+H2, T4, Enclosure Type 4 Europe: Ex II 2G EEx d IIC T4 Tamb = 60 C Oven: Airless heat sink, maximum 100 C (212 F) Tamb = 60 C Valves: 6-port and 10-port diaphragm chromatograph valves Other types of valves may be used depending on the application such as liquid injection and rotary valves Carrier Gas: Application dependent. Typically zero-grade helium, nitrogen or hydrogen at 90 psig Detector: Thermal Conductivity Detector (TCD), Flame Ionization Detector (FID); TCD/TCD or TCD/FID dual detector configurations possible; Flame Photometric Detector (FPD) available (see FPD Module data sheet) Gating Options: Fixed-Time, Slope and Automatic gating of peaks Streams: Up to 8 streams (including calibration stream) Analog Inputs: Four inputs filtered with transient protection (user scalable and assignable) Analog Outputs: Four non-isolated analog outputs, 4 20 ma (standard); four additional isolated analog outputs or eight additional non-isolated analog outputs (optional) Serial Communication Ports: Three serial ports standard with option for a total of seven. Depending on the port, choice of RS-232, RS-422 and RS-485 is available as well as the Modbus protocol Digital Inputs: Five digital inputs; user assignable Digital Outputs: One gas chromatograph alarm and four user assignable outputs (2 form A, 3 solid-state optically isolated) Parallel Printer Port: One parallel port available for printed reports Internal Modem (optional): Field-configurable; 300 to 33.6k baud rate Ethernet Card (optional): 10 mbps with RJ-45 port OUTLINE AND MOUNTING DETAILS 25.4 22.4 MOUNT OPTION 15.50 22.7 4X Ø.50 THRU 13.6 26.25 REMOVAL CLEARANCE TYPICAL 56.6 1.56 SAMPLE PLATE 58.4 12.0 36.8 SAMPLE PLATE 16.75 18.2 33.8 RECOMMENDED FROM GROUND OR FLOOR 16.5 22.1 FRONT VIEW FLOOR MOUNT UNIT SIDE VIEW FLOOR MOUNT UNIT FRONT VIEW WALL MOUNT UNIT POLE MOUNT UNIT The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available on request. We reserve the right to modify or improve the designs or specifi cations of our products at any time without notice. Emerson Process Management Rosemount Analytical Inc. Process Analytic Division 5650 Brittmoore Road Houston, TX 77041 USA T: 713.827.6380, F: 713.827.3865 Toll Free in US and Canada: 1.866.GC.CENTER Email: gc.csc@emersonprocess.com www.raihome.com Rosemount Analytical Inc., 2005. All rights reserved. Printed in U.S.A. on recycled paper.