Industrial Computed Tomography YXLON International YXLON. The reason why 1
CT - applications YXLON. The reason why 2
CT - principles Computed Tomography (Line Detector) YXLON. The reason why 3
CT - principles 12000 10000 8000 Zählrate 6000 4000 2000 0 Detektorkanäle absorption profile sinogram reconstructed image YXLON. The reason why 4
CT - principles stack of 2D images volume data YXLON. The reason why 5
CT - principles Computed Tomography (Flat Panel) YXLON. The reason why 6
CT - principles set of projections volume data YXLON. The reason why 7
CT - applications Vizualization / NDT / geometrical measurement PU foam Al foam Al foam/ steel compound YXLON. The reason why 8
CT - applications NDT Aluminum casting YXLON. The reason why 9
CT - applications Visualization tool for injection moulding YXLON. The reason why 10
CT - applications Geometrical measurement cylinder/crank case YXLON. The reason why 11
CT - applications Visualization Sandstone sculpture (Cathedral of Mainz) YXLON. The reason why 12
CT - applications NDT casting defect in cylinder/crank case YXLON. The reason why 13
CT - applications NDT heater plug YXLON. The reason why 14
CT - applications NDT welding seam YXLON. The reason why 15
CT - applications Vizualization / NDT ceramic sphere YXLON. The reason why 16
CT - applications Vizualization / NDT cylinder head YXLON. The reason why 17
CT - applications Vizualization / NDT mounted device YXLON. The reason why 18
CT - applications Vizualization / NDT / geometrical measurement truck tire YXLON. The reason why 19
CT - applications 2D images or volume data polygon extraction (STL model) surface reconstruction (CAD model) - defect analysis - position control - geometrical measuring - nominal/actual comparison - rapid prototyping - FE simulations nominal/actual comparison CAD model YXLON. The reason why 20
CT - applications nominal/actual actual value comparison YXLON. The reason why 21
CT - applications solidification simulation YXLON. The reason why 22
CT - applications Reverse Engineering Reproduction of a cylinder head (1937 model) YXLON. The reason why 23
CT - systems General remarks resolution vs. object size YXLON. The reason why 24
CT - systems Small for objects with < 220 mm Ø < 500 mm height < 15 kg Line detector array < 50μm pitch < 1% contrast resolution (available with Flat-Panel) 225 kv Minifocus X-ray source (available with Microfocus) 4-axis high accuracy manipulator (+/- 10 µm) YXLON. The reason why 25
CT - systems Compact for objects with < 335 mm Ø < 500 mm height < 30 kg Line detector array 120 μm / 0.5% or Flat-Panel 400 µm / 1 % 160... 450 kv X-ray source 5-axis high load manipulator (+/- 50 µm) YXLON. The reason why 26
CT - systems Medium for objects with < 525 / 900 mm Ø < 1,000 mm height < 150 kg Line detector array 100 μm pitch 0.1% contrast resolution 450 kv X-ray source 225 kv Minifocus 5-axis high load manipulator (+/- 50 µm) YXLON. The reason why 27
CT - systems Medium for objects with < 525 / 900 mm Ø < 1,200 mm height < 50 kg Line detector array (100 μm / 0.1%) and Flat-Panel (400 µm / 1 %) 450 kv X-ray source 6-axis high accuracy manipulator (+/- 25 µm) YXLON. The reason why 28
CT - systems Large for objects with < 800 / 1300 mm Ø < 1,500 mm height < 350 kg Line detector array 600 μm pitch (250 µm available) 0.5% contrast resolution 2.5 MeV linear accelerator 5-axis high load manipulator (+/- 50 µm) YXLON. The reason why 29
CT - systems Detector-Capabilities for geometrical measurement YXLON. The reason why 30
CT - systems Comparison low energy appl. Line detector array 170 kv Aluminum YXLON. The reason why 31
CT - systems Comparison low energy appl. Flat Panel 170 kv Aluminum YXLON. The reason why 32
CT - systems Comparison dynamic range YXLON. The reason why 33
CT - systems Comparison high energy appl. Line detector array 450 kv Aluminum YXLON. The reason why 34
CT - systems Comparison high energy appl. Flat Panel 450 kv Aluminum YXLON. The reason why 35
CT - principles Computed Tomography (3D-CT) YXLON. The reason why 36
CT - systems Comparison LDA vs. Flat Panel speed spatial resolution contrast resolution detectability Visualization NDT geometrical measurement reverse engineering YXLON. The reason why 37
CT - systems Capabilities YXLON-CT-systems are usable for any material (as long as absorbing) any object (as long as penetrable) any application (as far as thinkable) YXLON-CT-systems are used with LDA (2D-CT) or FlatPanel(3D-CT) or both combined Micro-, Mini-, Macro-X-ray sources Radioisotopes, Linear accelerators on-top-equipment YXLON. The reason why 38
CT - systems Features YXLON-CT-systems are optimized for high performance (speed, resolution) high throughput (in-line reconstruction) high accuracy (manipulation) high reliability (industrial design, remote service) YXLON-CT-systems include easy-to-use operator interface 3D-visualization image analysis & measurement tools open interfaces YXLON. The reason why 39
YXLON International X-Ray GmbH www.yxlon.com YXLON. The reason why 40