4D Auto MVQ (Mitral Valve Quantification)

Similar documents
GE Healthcare. Vivid 7 Dimension 08 Cardiovascular ultrasound system

GE Healthcare. Vivid E9 XDclear. with

GE Healthcare. Vivid E9 XDclear. with. healthymagination. GE imagination at work

EchoPAC Software Only v201

What you should know about the new release

csound 2.0 Vivid E95 gehealthcare.com Background

A powerful, software-based beamformer image reconstruction platform

Ultrasound. Q-Station software. Streamlined workflow solutions. Philips Q-Station ultrasound workspace software

Accurate Regression-based 4D Mitral Valve Segmentation from 2D MRI Slices

LOGIQ. V2 Ultrasound. Part of LOGIQ Vision Series. Imagination at work LOGIQ is a trademark of General Electric Company.

3D Echocardiography Development Timeline

Modeling Mitral Valve Leaflets from Three-Dimensional Ultrasound

Using TeraRecon intuition Viewer with STAT Quick Reference Guide

This is your imaging dashboard. There is a bevy of valuable information to read from here. Let s break it up.

Volumetric Analysis of the Heart from Tagged-MRI. Introduction & Background

Technical Principles of Transthoracic Three-Dimensional Echocardiography

icatvision Quick Reference

Mitral Annulus Segmentation From 3D Ultrasound Using Graph Cuts

PASS Sample Size Software

3D Surface Plots with Groups

Chapter 9 Conclusions

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc.

QAngio XA 7.3. Quick Start Manual. July 31, v6.0

Analysis of CMR images within an integrated healthcare framework for remote monitoring

Contour LS-K Optical Surface Profiler

Presenting System 1* v18.1

Leica Cyclone 5.4 Technical Specifications

A Semi-automatic Endocardial Border Detection Method for 4D Ultrasound Data

Development of 3D Model-based Morphometric Method for Assessment of Human Weight-bearing Joint. Taeho Kim

PREMIER DIAGNOSTIC ULTRASOUND. Diagnostic ultrasound. that delivers unparalleled. image resolution.

8/3/2017. Contour Assessment for Quality Assurance and Data Mining. Objective. Outline. Tom Purdie, PhD, MCCPM

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.

Robust Live Tracking of Mitral Valve Annulus for Minimally-Invasive Intervention Guidance

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

BUZZ - DIGITAL OR WHITEPAPER

PalmScan PRO 5 in 1 Biometer Your Complete Biometry System - Fully Configurable

Clinical Importance. Aortic Stenosis. Aortic Regurgitation. Ultrasound vs. MRI. Carotid Artery Stenosis

DICOM Conformance Statement

Segment CT Instructions For Use - English

Resona 7. New Waves in Ultrasound Innovation. Premium Ultrasound System

Improving Access to Healthcare. CLINiC. Clinical Care Device. Capsa Cart & Wall Mount Solutions Featuring the CLINiC

NUCLeUS: Your Partner Before, During & After Surgery

Resona 7. Premium Ultrasound System. New Waves in Ultrasound Innovation

GE Healthcare CLINICAL GALLERY. Discovery * MR750w 3.0T. This brochure is intended for European healthcare professionals.

SUPPLEMENTARY INFORMATION

Fluorescence Tomography Source Reconstruction and Analysis

SHARP Pen Software. Version 2.2 OPERATION MANUAL

syngo.mr Neuro 3D: Your All-In-One Post Processing, Visualization and Reporting Engine for BOLD Functional and Diffusion Tensor MR Imaging Datasets

EPSRC Centre for Doctoral Training in Industrially Focused Mathematical Modelling

PART I GravoStyle5-Laser Introduction

ilook 25 Next Generation in Portable Ultrasound Delivering the Personal Imaging Tool

XD 3.6 Release Notes

T-SCAN 3 3D DIGITIZING

Morphometric Analysis of Biomedical Images. Sara Rolfe 10/9/17

Case TAVR080: Aortic Valve Step-by-Step Guide

By your side. Anytime. Anywhere.

YOUR WAY TO PRECISE OUTCOMES

Object Identification in Ultrasound Scans

EnSite NavX Navigation and Visualization Technology EnSite Fusion Registration Module Procedure Guide

Ultrasound To Go. MySono U5

The Supreme 3D/4D Ultrasound. The Supreme 3D/4D Ultrasound. CT-V20-ICM

Quantitative Three-Dimensional Imaging of the Posterior Segment with the Heidelberg Retina Tomograph

SHARP Pen Software. Version 2.3 OPERATION MANUAL

Anatomic Growth Modelling of Cleft Palate Shape. S.K. Chua*, S.H. Ong*, K.W.C. Foong**

연구용유방초음파질관리 원광대학병원김혜원

Dell Canvas Layout. Version 1.0 User s Guide

CADMATIC is a registered trademark of CADMATIC Oy. All other trademarks are the property of their respective owners.

From Eye to Insight Hand-held, contact-free Optical Coherence Tomography for pediatrics ENVISU C2300 OCT Take OCT to your patient FDA 510(k) Cleared

QMass 8.1. Quick Start Manual. June 13, v2.0

A Comprehensive Method for Geometrically Correct 3-D Reconstruction of Coronary Arteries by Fusion of Intravascular Ultrasound and Biplane Angiography

SAFI Sample Projects. Design of a Steel Structure. SAFI Quality Software Inc. 3393, chemin Sainte-Foy Ste-Foy, Quebec, G1X 1S7 Canada

7D Cardiac Flow MRI: Techniques & Automation of Reconstruction

Creating a Basic Chart in Excel 2007

Roof Designer USER S GUIDE

Coke Drum Laser Profiling

Impact of 3D Laser Data Resolution and Accuracy on Pipeline Dents Strain Analysis

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Automatic Subthalamic Nucleus Targeting for Deep Brain Stimulation. A Validation Study

Microsoft Office Excel

NEW! PORTABLE DIAGNOSTIC ULTRASOUND PLATFORM. Considered to be the gold standard in ophthalmic diagnostic ultrasound,

Kaluza C Analysis Software PROTECTS YOUR DATA AND YOUR REPUTATION.

QIBA PET Amyloid BC March 11, Agenda

What s new in Solutionix s scanners?

Mitral Annulus Segmentation from 3D Ultrasound Using Graph Cuts

GE Healthcare. AppsLinq* remote courses catalogue

Improve your image. ClearVue 350 ultrasound system

coding of various parts showing different features, the possibility of rotation or of hiding covering parts of the object's surface to gain an insight

User Manual 2.1.1(draft)

STIC AmSud Project. Graph cut based segmentation of cardiac ventricles in MRI: a shape-prior based approach

A Framework for Real-time Left Ventricular tracking in 3D+T Echocardiography, Using Nonlinear Deformable Contours and Kalman Filter Based Tracking

Focus on your needs. Ultrasound system HS60 SAMSUNG MEDISON CO., LTD. CT-HS60 V1.0-OB-FT EN

ezimagex2 User s Guide Version 1.0

Using Pinnacle 16 Deformable Image registration in a re-treat scenario

DAILY LINAC QA BEAM QA

David Wagner, Kaan Divringi, Can Ozcan Ozen Engineering

M2M GEKKO. State-of-the-art phased-array flaw detector with TFM

Internal Organ Modeling and Human Activity Analysis

Section 7.2 Volume: The Disk Method

MobileScan3D. MobileScan3D PlugIn for Geomagic. By Steintek GmbH

User Guide. mk Config

Transcription:

4D Auto MVQ (Mitral Valve Quantification) Federico Veronesi, Glenn Reidar Lie, Stein Inge Rabben GE Healthcare Introduction As the number of mitral valve repairs is on the rise, so is the need for mitral valve quantification. Due to the complex anatomy and physiology of the mitral valve apparatus, 4D visualization and quantification is becoming increasingly important. The use of 4D imaging prior to, during and after these repairs is mandatory for certain procedures. 4D quantification tools for the mitral valve have existed for some time and are available from several vendors. These tools provide more objective and accurate measurements as compared to 2D quantification tools, where access to desired views may be more difficult. The 4D Mitral Valve Quantification tools are usually automated to achieve quick access to the measurements of interest. GE Healthcare has over the years introduced a series of quantification tools for 2D (e.g. 2D Strain, AFI and 2D Auto EF) as well as for 4D (4D Auto LVQ, 4D LV Mass, 4D Strain, 4D Auto AVQ). GE Healthcare has also licensed tools from TomTec. These tools, 4D RV Function and Mitral Valve Assessment, were implemented as plug-ins into our 4D ultrasound systems (Vivid E9, Vivid S70 with 4D and Vivid E95) as well as the EchoPAC work station. We have now implemented GE Healthcare s 4D Auto MVQ tool as a replacement for TomTec s Mitral Valve Assessment. * This tool is seamlessly integrated into the Vivid systems workflow providing quick access to 4D raw data analysis. gehealthcare.com

Method 4D Auto MVQ is a quantification tool for rapid semi-automated detection of morphology of the mitral valve, including the annulus and the leaflets. Segmentation of the MV during systole is performed using a multistep approach. First, from the user-identified landmarks the MV annulus is identified by means of template matching along an a-priori 3D saddle-shaped line. Then, the MV leaflets are represented by a surface which during segmentation is deformed using image data together with the tracked annulus. The segmentation is represented as a state estimation problem and solved with an extended Kalman filter. From the detected surface, the MV coaptation line and possibly MV orifice is detected considering shape and thickness of anterior and posterior MV leaflets. 4D Auto MVQ workflow description The fully integrated tool requires a 4D data set containing the mitral valve acquired with a TTE or a TEE probe, either in a full volume or zoomed acquisition. Care must be taken during acquisition to ensure that the complete valve, with the ring/annulus is included, and that the volume rate exceeds 12 volumes per second for adequate temporal assessment if dynamic systolic performance is of interest. Speed of access to stored 4D images (from pressing the 4D Auto MVQ button on the touch panel until the 4D data is available for analysis) is twice as fast compared to its predecessor. The 4D rendering quality of the valve is similar to that of the original scanner acquisition throughout the entire quantification procedure. The workflow is divided into stages (see Figure 1) accessible both through the touch panel as well as on the main screen. When entering the tool, the first step is to adjust 2D gain, 4D gain and zoom if needed. These controls are available throughout the remaining stages to always ensure optimal image quality. Then one can set/adjust the End Systolic (ES) and End Diastolic (ED) time events if needed. This is followed by an Alignment stage (see Figure 2) to ensure a standardized and expected view is obtained where the vertical axis crosses through the center of the MV, while the horizontal axis is parallel to the mitral valve. Six Landmark points (see Figure 3) are then placed (two mitral annulus points, two anterior/posterior points, the coaptation point plus the aorta point). Using the above described method, the tool then generates a model for the leaflets and the annulus which can easily be edited by the operator through an intuitive and flexible user interface. The editing offers undo/redo capabilities, and one can at any time go back and forth between the various stages as one observes the results and the potential need for editing. Both systolic and full cycle loops can be played, though the tool only displays the model during systole. Figure 2. Alignment stage Figure 1. Stages Figure 3. Landmark stage

The tool offers three layouts at the Review stage (Biplane, Scallops and Commissures) depending on assessment needs (See Figure 4). In the Review stage, the 3D model can be checked in all slices. To visualize the model in different slices, the user must rotate and translate the reference slices in 2D view (dotted lines) and observe the segmentation in the other interactive views. The 3D model is adjusted by clicking and dragging contours on 2D views when needed. Five layouts are offered at the Results stage, see Figure 5 (Biplane, Scallops, Compact, Dynamic and Measurements). The Results layouts show all the Annulus and Leaflets parameters including three that were not supported in the predecessor tool (Inter-trigonal Distance, Anterior Leaflet Angle and Billowing Height). Figure 4. Review Biplane The Laser Lines introduced on GE systems years ago can be offered as an overlay on to the model to ease orientation both in the Review and Results stages. The ten most commonly requested and used measurements are transferred into the Worksheet for reporting when selecting the Approve & Exit button. Now, the tool also stores the complete setup and the results together with the exact screen view. When later recalling this particular image/loop and entering the 4D Auto MVQ tool, all prior alignments, landmarks, models and results are recalled for ease of continued analysis and review. This also serves as quality control. Figure 5. Results Compact Additionally, for documentation purposes at any time during use of the tool, image screen shots can be stored to the clipboard and be part of the study.

Validation The 4D Auto MVQ tool has been compared to the MV Assessment tool by TomTec on a set of 20 4D datasets including both normal subjects and patients affected by mitral valve disease. Results of the comparison are reported in table 1 as average ± standard deviation. For further information regarding the validation, contact your local representative. Limitations: The measurements obtained from the two products compared in the validation span a clinically significant range. However, the number of subjects analyzed is limited and further studies on specific populations are needed to identify the clinical benefit of using advanced 3D tools to characterize the MV. Both 4D Auto MVQ (and MV Assessment TomTec) use an automated segmentation algorithm to initiate a 3D model from where the tool s measurements are calculated. There is an inherent risk that these automated segmentation algorithms may give inaccurate 3D models. That means that the tool results should not be approved without review and, if necessary, editing of the 3D model. If the tools are used without review and editing, the expected accuracy will be negatively affected. Table 1. Comparison between 4D Auto MV and MVA Assessment tool by TomTec Annulus Perimeter Measurement unit Values MVQ Values TomTec TomTec - MVQ Difference cm 13.7 ± 2.6 13.71 ± 2.64 0.01 ± 0.58 * Annulus Area 3D cm 2 15.12 ± 5.57 14.51 ± 5.32-0.61 ± 1.37 * AL-PM diameter cm 4.44 ± 0.78 4.37 ± 0.82-0.07 ± 0.25 * A-P diameter cm 3.76 ± 0.78 3.86 ± 0.83 0.11 ± 0.34 * Annulus Height mm 7.05 ± 2.59 7.46 ± 2.14 0.42 ± 1.58 * Mitral Annular Excursion Leaflet Angle Mitral-Aortic Angle Anterior Leaflet Area Leaflet Area mm 6.58 ± 3.37 7.02 ± 3.22 0.44 ± 2.1 * 21.85 ± 17.72 23.76 ± 15.05 1.91 ± 6.85 * 127.7 ± 10.4 127.72 ± 14.12 0.08 ± 8.59 * cm 2 7.64 ± 2.42 7.77 ± 2.63 0.13 ± 1.0 * cm 2 8.48 ± 4.11 8.83 ± 4.12 0.36 ± 1.0 * Tenting Height cm 0.62 ± 0.39 0.62 ± 0.29 0.0 ± 0.26 * Anterior Leaflet Length Leaflet Length *Not significantly different (Two-tails paired Student s t-test with P>0.05) cm 2.48 ± 0.53 2.46 ± 0.48-0.02 ± 0.23 * cm 1.77 ± 0.68 1.87 ± 0.71 0.11 ± 0.24 *

Imagination at work * Available on the Vivid E95 and Vivid S70N 4D Productivity Elevated release. 2017 General Electric Company All rights reserved. GE Healthcare reserves the right to make changes in specifications and features shown herein, or discontinue the product described at any time without notice or obligation. Contact your GE Healthcare representative for the most current information. Please visit www.gehealthcare.com/promotionallocations. GE, the GE Monogram, imagination at work, Vivid and EchoPAC are trademarks of General Electric Company or one of its subsidiaries. GE Healthcare, a division of General Electric Company. TomTec is a trademark of TomTec Imaging Systems GmbH. Third party trademarks are the property of their respective owners. GE Medical Systems Ultrasound & Primary Care Diagnostics, LLC, a General Electric Company, doing business as GE Healthcare. JB48903XX