Comparison of measured and Monte Carlo calculated electron beam central axis depth dose in water

Similar documents
Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Evaluation of latent variances in Monte Carlo dose calculations with Varian TrueBeam photon phase-spaces used as a particle source

Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Source Model Tuning for a 6 MV Photon Beam used in Radiotherapy

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

SHIELDING DEPTH DETERMINATION OF COBALT PHOTON SHOWER THROUGH LEAD, ALUMINUM AND AIR USING MONTE CARLO SIMULATION

Suitability Study of MCNP Monte Carlo Program for Use in Medical Physics

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

Improvements in Monte Carlo simulation of large electron fields

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Monte Carlo modeling of a Novalis TX Varian 6 MV with HD-120 multileaf collimator

ARTCOLL PACKAGE FOR GAMMA ART6000 TM ROTATING GAMMA SYSTEM EMISSION SPECTRA CALCULATION

Validation of GEANT4 Monte Carlo Simulation Code for 6 MV Varian Linac Photon Beam

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Implementation of Monte Carlo Dose calculation for CyberKnife treatment planning

Shielding factors for traditional safety glasses

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

Michael Speiser, Ph.D.

Basics of treatment planning II

Implementation of a double Gaussian source model for the BEAMnrc Monte Carlo code and its influence on small fields dose distributions

Code characteristics

Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling

Effects of the difference in tube voltage of the CT scanner on. dose calculation

A virtual photon energy fluence model for Monte Carlo dose calculation

Image-based Monte Carlo calculations for dosimetry

Monte Carlo evaluation of the dosimetric uncertainty in matched 6 MV Elekta and Varian linear accelerators

I Introduction 2. IV Relative dose in electron and photon beams 26 IV.A Dose and kerma per unit incident fluence... 27

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

On compensator design for photon beam intensity-modulated conformal therapy

Limitations in the PHOTON Monte Carlo gamma transport code

An investigation into the use of MMCTP to tune accelerator source parameters and testing its clinical application

Megan A. Wood, M.S. Under the direction of Larry DeWerd, Ph.D. University of Wisconsin Medical Radiation Research Center (UWMRRC)

84 Luo heng-ming et al Vol. 12 Under the condition of one-dimensional slab geometry the transport equation for photons reads ±()N(x; μ; ) du d N(

Disclosure 7/24/2014. Validation of Monte Carlo Simulations For Medical Imaging Experimental validation and the AAPM Task Group 195 Report

Radiation Beam Characterization and Dosimetry of Theratron Equinox-80 Telecobalt Machine Using BEAMnrc Monte Carlo Simulation Code

Influence of electron density spatial distribution and X-ray beam quality during CT simulation on dose calculation accuracy

Supercomputing the Cascade Processes of Radiation Transport

Investigation of photon beam output factors for conformal radiation therapy Monte Carlo simulations and measurements

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

Application of MCNP Code in Shielding Design for Radioactive Sources

Study of scattered photons from the collimator system of Leksell Gamma Knife using the EGS4 Monte Carlo Code

A fast and accurate GPU-based proton transport Monte Carlo simulation for validating proton therapy treatment plans

Particle track plotting in Visual MCNP6 Randy Schwarz 1,*

Transitioning from pencil beam to Monte Carlo for electron dose calculations

15 Dose Calculation Algorithms

Monte Carlo simulation of electron beams from an accelerator head using PENELOPE

Monte Carlo Treatment Planning: Implementation of Clinical Systems

Monte Carlo Simulations: Efficiency Improvement Techniques and Statistical Considerations

Room scatter effects in Total Skin Electron Irradiation: Monte Carlo simulation study

Application of efficient Monte Carlo photon beam simulations to dose calculations in voxellized human phantoms

Outline. Monte Carlo Radiation Transport Modeling Overview (MCNP5/6) Monte Carlo technique: Example. Monte Carlo technique: Introduction

Clinical implementation of photon beam flatness measurements to verify beam quality

Release Notes for Dosimetry Check with Convolution-Superposition Collapsed Cone Algorithm (CC)

Comprehensive evaluation and clinical implementation of commercially available Monte Carlo dose calculation algorithm

Modeling the ORTEC EX-100 Detector using MCNP

Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode

UNCOMPROMISING QUALITY

A CT-based Monte Carlo Dose Calculations for Proton Therapy Using a New Interface Program

ISOCS Characterization of Sodium Iodide Detectors for Gamma-Ray Spectrometry

Monte Carlo simulation of photon and electron transport

Accuracy of treatment planning calculations for conformal radiotherapy van 't Veld, Aart Adeodatus

Monte Carlo Method for Medical & Health Physics

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

BEAMDP Users Manual. C.-M. Ma and D.W.O. Rogers Ionizing Radiation Standards National Research Council of Canada, Ottawa

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

Mathematical methods and simulations tools useful in medical radiation physics

Basic Radiation Oncology Physics

Absorbed Fractions for Multi-Region Models of the Kidneys in ICRP/ICRU Voxel Phantoms

Monte Carlo-based inverse treatment planning

Verification measurements of an emc algorithm using a 2D ion chamber array

Basics of treatment planning II

VALIDATION OF A MONTE CARLO DOSE CALCULATION ALGORITHM FOR CLINICAL ELECTRON BEAMS IN THE PRESENCE OF PHANTOMS WITH COMPLEX HETEROGENEITIES

An EGSnrc generated TG-43 dosimetry parameter database

Proton dose calculation algorithms and configuration data

ANALYSIS OF CT AND PET/SPECT IMAGES FOR DOSIMETRY CALCULATION

An approach to calculate and visualize intraoperative scattered radiation exposure

Dose Point Kernel calculation and modelling with nuclear medicine dosimetry purposes

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona

A dedicated tool for PET scanner simulations using FLUKA

A SYSTEM OF DOSIMETRIC CALCULATIONS

Simulation of Radiographic Testing for POD Assessment

Monte Carlo simulations. Lesson FYSKJM4710 Eirik Malinen

Overview and Applications of the Monte Carlo Radiation Transport Tool Kit at LLNL

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 1, 2014

Transcription:

Original article UDC: 681.324:519.245 Archive of Oncology 2001;9(2):83-7. Comparison of measured and Monte Carlo calculated electron beam central axis depth dose in water Darko LALIÆ 1 Radovan D. ILIÆ 2 Srboljub J. STANKOVIÆ 3 1 MILITARY MEDICAL ACADEMY BELGRADE, RADIOTHERAPY DEPARTMENT, BELGRADE, YUGOSLAVIA 2 INSTITUTE OF NUCLEAR SCIENCES VINÈA, PHYSICS LABORATORY (010), VINÈA, YUGOSLAVIA 3 INSTITUTE OF NUCLEAR SCIENCES VINÈA, RADIATION PROTECTION DEPARTMENT, VINÈA, YUGOSLAVIA BACKGROUND: The Monte Carlo method is the most accurate means of predicting dose distributions in radiation treatment of patients. Owing to rapid development of computer technology the use of this method is now not restricted only to big research centers. A Monte Carlo simulation of medical linear accelerator head and central axis depth dose calculation for electron beams are presented in this work. METHODS: Calculation of central axis depth dose distributions for 6, 9 and 12 MeV electron beams from medical linear accelerator Varian 2100C was performed with program FOTELP on personal computer. FOTELP is a general purpose Monte Carlo code for simulation of coupled transport of photons, electrons and positrons. The results of calculations were compared with experimental data. Measurement of electron central axis depth dose distributions was performed with automatic field analyzer in water. RESULTS: Good agreement between calculated and measured data is demonstrated for depths from surface of water phantom to depth on which dose falls to about 50% of maximum dose on central axis. Systematic discrepancies between measured and calculated data exist under depth of 50% dose. Simplification of geometrical model of accelerator head is supposed to be the main reason for these discrepancies. CONCLUSION: Because of limited computer power (333MHz Celeron processor) it was necessary to simplify geometric model of accelerator head and to follow relatively modest number of electron histories. In this sense the results of calculations could be estimated as very good. In order to achieve better agreement between calculated and measured data or to perform more complex calculations a much more powerful hardware is needed. KEY WORDS: Monte Carlo Method; Phantoms, Imaging; Software; Radiotherapy Dosage Archive of Oncology 2001,9(2):83-87 2001, Institute of Oncology Sremska Kamenica, Yugoslavia INTRODUCTION T he Monte Carlo simulation of radiation transport is the most accurate means of predicting dose distributions and other quantities of interest in radiation treatment of patients (1). Due mainly to long computational times, Monte Carlo techniques are mainly used for investigational purposes. However, owing to rapid development of computer technology and algorithms the use of this method is now not restricted only to big research centers. It appears that we are rapidly approaching a time when Monte Carlo Address correspondence to: Darko Laliæ, Military Medical Academy, Radiotherapy Department, Crnotravska 17, 11000 Belgrade, Yugoslavia The manuscript was received: 07. 02. 2001. Provisionally accepted: 18. 02. 2001. Accepted for publication: 19. 03. 2001. simulations will be part of everyday practice in radiotherapy departments. The aim of this work was to calculate electron central axis depth dose data in water using general purpose Monte Carlo code FOTELP (2-4) and to compare calculated and measured distributions in water phantom. Calculation was done for 6, 9 and 12 MeV electron beams from medical linear accelerator Varian 2100C (Varian, Paolo Alto, USA). Simulation of particle transport through accelerator head and water phantom was done on a personal computer with 333 MHz Celeron processor and 64MB RAM. The geometrical model of accelerator head was made according to schemes, specially prepared by the manufacturer for purposes of Monte Carlo simulations (Monte Carlo Project No. 73). Experimental determination of depth dose distribution was performed with automatic field analyzer RTD (Multidata, St. Louise, 83

Laliæ D. USA). The motivation for this work was not only the increasing importance of Monte Carlo simulation in external beam radiotherapy, but also the possibility to use domestic program FOTELP, which can be easily installed on personal computers. Program FOTELP is a general purpose Monte Carlo code for the simulation of the coupled transport of electrons, positrons and photons. For purposes of external beam radiotherapy calculations this program was specially adjusted by its author Dr. R. Iliæ. Some of its capabilities, which make this program well suited for accelerator head modeling will be only briefly mentioned in this work. Attention will be paid mainly to the evaluation of results of central axis depth dose distributions simulation. Good agreement between simulated and measured data, which is demonstrated in this work, shows that program FOTELP is a valuable tool for radiotherapy calculations. The geometry and spectral characteristics of source, number of simulated particles from source and dimension of elementary volumes (voxel) in which the absorbed dose is scored are recorded in file FOTELP.inp. Geometrical model and calculation details The simplified model of Varian 2100C accelerator is shown in Figure 1. After leaving accelerator tube (1), narrow electron beam (2) travels through focusing coil system (3), bending chamber (4), vacuum window (5)(6), upper scattering foil (7), primary collimator opening (8), lower scattering foil (9), ionization chamber (10), mirror (11), movable collimator jaws (12) and finally, through electron applicator (13). Description of construction and role of these parts are beyond the scope of this work, for more details reader should consult reference (9). MATERIALS AND METHODS Software package FOTELP Software package FOTELP (2-4) is a general purpose Monte Carlo code to simulate the coupled transport of photons, electrons and positrons by the Monte Carlo method for numerical experiments in dosimetry, radiation shielding, radiotherapy, for evaluating the efficiency of detectors, and counters, for computing the absorbed energy in the layers of microelectronics components, for estimating radiation damage of materials, and other numerical experiments concerning the mentioned particles. Codes from this package perform calculations in 3D geometry with random spectra of particles having energy in the range from 1 kev to 100 MeV, and material region for which geometry can be described by planes and surfaces of the second order. FOTELP codes apply transition probabilities from the previous to the following state of phase space, which are prepared by FEPDAT code. Software package FOTELP, as other well-known programs, for instance BEAM (5) and PEREGRINE (6), PENELOPE (7,8), is adjusted to meet the special requirements of external beam radiotherapy calculations. This means that the code produces a phasespace output of the beam at any specified plane in the model (i.e. position, energy, direction and type for each particle crossing this plane).this phase-space file can be reused by the program FOTELP as an input for simulation of particle transport in water phantom or can be analyzed to obtain beam characteristics. The FOTELP code user prepares three input files in the text editor (2). The geometrical model of accelerator head and water phantom is described in file Rfg.inp. The physical and chemical characteristic of all materials included in the model as well as data for the creation of an energetic scale are contained in file Fepdat.inp. Figure 1. The simplified model of medical linear accelerator treatment head. See text for explanation The geometrical model of accelerator head used for simulation in this work is presented in Figure 2. In order to achieve reasonable calculation times the model is simplified comparing with the manufacturer's blueprints. Following the terms of use, these blueprints and materials and the dimensions of accelerator head elements are not presented. The model consists of upper (I) and lower (III, V) scattering foils, movable collimator jaws (VIII) and finally water phantom beneath the accelerator head (X). Air layers between the 84

Comparison of measured and MC calculated electron beam elements of the accelerator head (II, IV, VI, VII) and between the head and water phantom (IX) are also presented. The symmetry axis of the model is Z-axis, coincident with the beam axis. Geometrical surfaces (D1 - D11) are also marked in Figure 1. Intersections of geometrical surfaces are denoted with numbers 14-23. number of electrons in the primary beam was set to 2x10 8. The absorbed dose was scored in quadratic volumes (voxel) centered on the central axis of beam in water. The dimensions of voxel was 2x2x2mm. The cutoff energies of electrons, photons and positrons were set to 500keV (10). Particles with energies under off-off value are locally absorbed, i.e. their transport is interrupted and energy is absorbed at a point. Another interruption of particle transport and local energy absorption is performed in collimator jaws. The program calculates the relationship between particle position and energy in jaws. If the particle has insufficient energy to leave the jaws, its transport is interrupted. As in the case of all other simplification, the reason for transport interruption is a reduction of computation times. RESULTS AND DISCUSSION The results of the calculation and measurements of 6, 9 and 12MeV electron central axis depth dose distributions in water are shown in Figures 3-5. Figure 2. Geometrical model of accelerator head used in FOTELP code. See text for explanation The main simplification of the model, omitting of electron applicator, was done according to previous Monte Carlo calculations (5) which shows that electrons scattered from the applicator and collimator jaws contribute only about 10% to the surface dose. Electrons from the applicator are the least penetrating since some of them go through applicator scarpers. The segment ionization chamber and mirror are not included in the model because they are very thin in the direction of beam propagation. The primary electron beam entering the upper scattering foil (point Z=0 in Figure 1.) was supposed to be monoenergetic, because of a lack of adequate information on its spectral characteristics (10). The energy of this beam was adjusted to match the depth at which the dose falls to 50% of dose maximum on the measured central-axis depth-dose curve in water phantom. The Figure 3. Calculated and measured 6MeV electron beam central axis depth dose distribution In depth range from surface to depth, at which the dose falls to about 50% of the maximum dose, the agreement between calculated and measured values is very good. In this depth range the statistical precision of simulation is about 3% (on 1 level) and results coincidence within this range. 85

Laliæ D. Figure 4. Calculated and measured 9MeV electron beam central axis depth dose distribution Discrepancies between the calculated and measured dose exist for depths beneath the depth of 50% dose - calculated values are lower than measured. The precision of simulation in this depth range is also lower and is about 5%. Discrepancies between calculated and measured values can be partially explained by a lack of bremsstrahlung photons. The reason for this is an interruption of particle transport in collimator jaws; some of the absorbed electrons would otherwise produce bremsstrahlung photons. Another reason could be the difference between the stated and the actual scattering foil thickness. It is well known that most of bremsstrahlung photons are produced in scattering foils, so small differences in thickness can result in wrong predictions about bremsstrahlung photon production. (10). Finally, it should be mentioned that the low precision of simulation could also contribute to discrepancies between calculated and measured data. The depth range where the agreement between the results of simulation and measurement is good is very important for electron radiotherapy. It is obvious that program FOTELP with the simplified model of accelerator head can correctly calculate the socalled therapeutic range of beam (important in treatment planning) and a depth of 50% dose. The latter quantity is very important in electron beam dosimetry. The calculation time is a very important characteristic of every Monte Carlo simulation. Unfortunately, due to problems with GET- TIME routine in Fortran Power Station Compiler (Microsoft, USA) it was not possible to measure calculation times exactly. Problems appeared on several computers. Calculation times for simulation of 2x10 8 electron histories were about 50-90 hours. Routine GETTIME was not able to register so long time periods. For the same reason it was not possible to check some important relationships between the number of simulated electron histories, calculation times and statistical precision of simulation (11-13). CONCLUSION Figure 5. Calculated and measured 12MeV electron beam central axis depth dose distribution This work presents an initial step in radiotherapy calculations with FOTELP code. Two main field of interest are covered: radiotherapy treatment unit simulation (5,7,8) and dose distribution calculation based upon voxelized geometry of medium (14-16). Obtained results are encouraging for further investigations in the field of radiotherapy Monte Carlo simulations. In order to compute correctly the central axis depth dose distribution in the whole depth range, it will be necessary to include all relevant elements of the accelerator head in the geometrical model and to increase the number of simulated particles. In this case it would be possible to carry on a more complex calculations. This task can be realized only on much more powerful hardware. For instance, program Peregrine runs on a system of 24 86

Comparison of measured and MC calculated electron beam Pentium II processors, 300MHz each. This configuration permits the transport of about 2x10 8 particles through a grid of 2x2x2mm voxel in only one hour. On such a system it is possible to achieve statistical precision of order 1.5% within few hours. REFERENCES 1. Jette D. Electron beam dose calculations. In Physics of radiation therapy. Berlin: Springer Verlag; 1994. 2. Ilic RD. Instructions for use of FOTELP software package, version G2k. Beograd, 2000. 3. Ilic RD. Monte Carlo techniques in the transport of particles. Belgrade: Naucna knjiga; 1991. 4. Ilic RD. Computer simulation of transport of electrons through substance. Elektron- 100 godina od otkrica. Vol. 6. Belgrade: SANU; 1997. 5. Rogers DWO, Fadegong BA, Ding GX, MA M and Mackie TR. Beam: A Monte Carlo code to simulate radiotherapy treatment units. Medical Physics 1995;22:503-24. 6. Hartmann Siantar CL, Bergstrom PM, Chandler WP, Chase L, Cox LJ, Daly TP et al. Lawrence Livermore National LaboratoryÕs Peregrine project. UCRL-JC- 126732. Livermore; 1997. 7. Mazurier J, Salvat F, Chauvenet B, Barthe J. Simulation of photon beams from Saturn 43 accelerator using the code PENELOPE. Phys Med 1999;XV(3). 8. Sempau J, S nchez-reyes A, Salvat F, Oulad ben Tahar H, Jiang SB, Fern ndez-varea JM. Monte Carlo simulation of electron beams from an accelerator head using PENELOPE. Phys Med Biol 2001;46(4). 9. International commission on radiation units and measurements (ICRU), Radiation dosimetry: Electron beams with energy between 1 and 50 MeV, ICRU 35, 1984. 10. Ding GX and Rogers DWO. Energy spectra, angular spread and dose distributions of electron beams from various accelerators used in radiotherapy. National Research Council of Canada 1995; Report PIRS 439. 11. Briesmeister JF (editor). MCNP - A general Monte Carlo N-particle transport code. Manual LA-12625. Los Alamos; 1997. 12. Bielajew AF, Efficiency, statistics and sampling, NRC Reports, PIRS-0395, 1996. 13. Bielajew AF, Rogers DWO, Variance reduction techniques, NRC Reports, PIRS-0396 1996. 14. du Plessis FCP, Willemse CA, Lštter MG, Goedhals L. Comparison of the Batho, ETAR and Monte Carlo dose calculation methods in CT based patient models. Med Phys 2001;28(4). 15. Schneider W, Bortfeld T and Schlegel W, Correlation between CT numbers and tissue parameters needed for Mont Carlo simulations of clinical dose distributions. Phys Med Biol 2000;45. 16. Schneider W, Bortfeld T, Schlegel W. Vergleich von CT-basierten 3D Monte Carlo Simulationen und semiempirischen Verfahren bei Elektronenbestrahlungen. In: Leitner H, Stucklschweiger G, eds. Medizinische Physik '96. Graz: DGMP; 1996. 87