Artifact Mitigation in High Energy CT via Monte Carlo Simulation

Similar documents
Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Simulation of Beam Hardening in Industrial CT with x-ray and Monoenergetic Source by Monte Carlo Code

Combining Analytical and Monte Carlo Modelling for Industrial Radiology

CBCT Equivalent Source Generation Using HVL and Beam Profile Measurements. Johnny Little PSM - Medical Physics Graduate Student University of Arizona

Fast iterative beam hardening correction based on frequency splitting in computed tomography

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

DUAL energy X-ray radiography [1] can be used to separate

Indrin Chetty Henry Ford Hospital Detroit, MI. AAPM Annual Meeting Houston 7:30-8:25 Mon 08/07/28 1/30

Scatter in an uncollimated x-ray CT machine based on a Geant4 Monte Carlo simulation. Wadeson, Nicola and Morton, Edward and Lionheart, William

Limitations in the PHOTON Monte Carlo gamma transport code

Spectral analysis of non-stationary CT noise

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Development a simple point source model for Elekta SL-25 linear accelerator using MCNP4C Monte Carlo code

Monte Carlo simulation of photon and electron transport

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

Determination of Three-Dimensional Voxel Sensitivity for Two- and Three-Headed Coincidence Imaging

Application of MCNP Code in Shielding Design for Radioactive Sources

Improvements in Monte Carlo simulation of large electron fields

Emission Computed Tomography Notes

Scatter Correction Methods in Dimensional CT

Proton dose calculation algorithms and configuration data

Measurement of depth-dose of linear accelerator and simulation by use of Geant4 computer code

ENHANCED IMAGING OF CORROSION IN AIRCRAFT STRUCTURES WITH REVERSE GEOMETRY X-RAY

Accelerated quantitative multi-material beam hardening correction(bhc) in cone-beam CT

I Introduction 2. IV Relative dose in electron and photon beams 26 IV.A Dose and kerma per unit incident fluence... 27

Monte Carlo simulations. Lesson FYSKJM4710 Eirik Malinen

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

Basics of treatment planning II

Photon Energy Spectrum Reconstruction Based on Monte Carlo and Measured Percentage Depth Dose in Accurate Radiotherapy

Impact of X-ray Scatter When Using CT-based Attenuation Correction in PET: A Monte Carlo Investigation

Introduction to Biomedical Imaging

X-ray simulation and applications

CIVA CT, an advanced simulation platform for NDT

Monte Carlo simulations

Source Model Tuning for a 6 MV Photon Beam used in Radiotherapy

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

SHIELDING DEPTH DETERMINATION OF COBALT PHOTON SHOWER THROUGH LEAD, ALUMINUM AND AIR USING MONTE CARLO SIMULATION

Index. aliasing artifacts and noise in CT images, 200 measurement of projection data, nondiffracting

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Synrad3D Photon propagation and scattering simulation

Outline. Monte Carlo Radiation Transport Modeling Overview (MCNP5/6) Monte Carlo technique: Example. Monte Carlo technique: Introduction

Performance of the ATLAS Inner Detector at the LHC

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

An Iterative Approach to the Beam Hardening Correction in Cone Beam CT (Proceedings)

A PRACTICAL ALGORITHM FOR RECONSTRUCTION FROM X-RAY

Comparison of Scatter Correction Methods for CBCT. Author(s): Suri, Roland E.; Virshup, Gary; Kaissl, Wolfgang; Zurkirchen, Luis

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

Ch. 4 Physical Principles of CT

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel

Determination of primary electron beam parameters in a Siemens Primus Linac using Monte Carlo simulation

A Curvelet based Sinogram Correction Method for Metal Artifact Reduction

DUE to beam polychromacity in CT and the energy dependence

Evaluation of Computed Tomography Techniques for Material Identification in Low Level and Intermediate Level Waste

Study of scattered photons from the collimator system of Leksell Gamma Knife using the EGS4 Monte Carlo Code

Comparison Study of Monte Carlo Simulations and Measurements of Relative Output Factors of 6 MV Photon Beam

18th World Conference on Nondestructive Testing, April 2012, Durban, South Africa

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Radiographic Simulator artist: Version 2

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

Metal Artifact Reduction CT Techniques. Tobias Dietrich University Hospital Balgrist University of Zurich Switzerland

(RMSE). Reconstructions showed that modeling the incremental blur improved the resolution of the attenuation map and quantitative accuracy.

Monte Carlo Methods for Accelerator Simulation and Photon Beam Modeling

Synrad: Program for Calculating Synchrotron Radiation Power

Unmatched Projector/Backprojector Pairs in an Iterative Reconstruction Algorithm

Prospects for spectral CT with Medipix detectors

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010

BEAMDP Users Manual. C.-M. Ma and D.W.O. Rogers Ionizing Radiation Standards National Research Council of Canada, Ottawa

CT vs. VolumeScope: image quality and dose comparison

Code characteristics

Release Notes for Dosimetry Check with Convolution-Superposition Collapsed Cone Algorithm (CC)

CALIBRATIONS FOR ANALYZING INDUSTRIAL SAMPLES ON MEDICAL CT SCANNERS

Improved Detector Response Characterization Method in ISOCS and LabSOCS

Moscow-Bavarian Joint Advanced Student School 2006 / Medical Imaging Principles of Computerized Tomographic Imaging and Cone-Beam Reconstruction

Non-Stationary CT Image Noise Spectrum Analysis

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

An Acquisition Geometry-Independent Calibration Tool for Industrial Computed Tomography

Scaling Calibration in the ATRACT Algorithm

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

π ± Charge Exchange Cross Section on Liquid Argon

X-ray tomography. X-ray tomography. Applications in Science. X-Rays. Notes. Notes. Notes. Notes

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

How beam hardening influences the dimensional geometry in X-ray computed tomography

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Quality control phantoms and protocol for a tomography system

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

Accuracy of treatment planning calculations for conformal radiotherapy van 't Veld, Aart Adeodatus

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

NON-COLLIMATED SCATTERED RADIATION TOMOGRAPHY

2D DOSE MEASUREMENT USING A FLAT PANEL EPID

Monte Carlo Method for Solving Inverse Problems of Radiation Transfer

Transcription:

PIERS ONLINE, VOL. 7, NO. 8, 11 791 Artifact Mitigation in High Energy CT via Monte Carlo Simulation Xuemin Jin and Robert Y. Levine Spectral Sciences, Inc., USA Abstract The high energy (< 15 MeV) incident polychromatic γ-ray spectrum and energyresolved photon attenuations in steel, obtained via EGS/BEAM Monte Carlo, were applied to derive beam hardening correction in steel cylinders and pipes. Monte Carlo simulated pencil beam projections were processed using latch bit filters to isolate exiting primary photons. The beam hardening correction was applied to these projections, which were then interpolated to a uniform grid. Filtered back projections of the raysums with and without the beam hardening correction were compared. It was demonstrated that beam hardening artifacts can be successfully removed for steel structures. 1. INTRODUCTION CT artifacts resulting from preferential absorption of lower energy photons in a polychromatic beam are known as beam hardening effects, and have been a focus of intense research [1,. The beam hardening correction (BHC) involves a renormalization of each measured intensity with a correction factor that depends on the measured intensity, the polychromatic input spectrum, an energy-dependent attenuation, and a reference monoenergetic photon beam energy [1. Steel is a high-z dense material upon which accelerator-based high energy (> 1 MeV) photon sources are applied for nondestructive testing (NDT) CT [3. In this paper, we apply the Monte Carlo simulated incident polychromatic γ-ray spectrum and the energy-resolved attenuation [3 to compute the BHC, and demonstrate procedures necessary to obtain corrected images with steel cylinders and pipes. Cylinders will have more beam hardening and scattering disparity along a projection, whereas the thin pipe boundaries are more easily masked by artifacts.. BEAM HARDENING CORRECTION OVERVIEW Formally, the measured raysum, r, from a polychromatic source with normalized incident spectral density S n (E) through a homogeneous material of attenuation µ(e) and thickness d is modeled as r = ln S n (E)e µ(e)d de (1) The BHC in CT converts r to an equivalent raysum µ(e )d for a monoenergetic source of reference energy E [1. For N incident photons and N detector particle counts, the raysum estimate r results from ln(n /N). The appropriate BHC for this measurement converts r to r = ln(n /N) + µ(e )d + ln S n (E)e µ(e)d de. () Monte Carlo simulation has a significant role in determining the BHC via calculation of the input attenuation µ(e) and spectral density S n (E) in Eq. ()..1. Polychromatic Sources The accelerator that creates a breamsstrahlung-generated photon flux for high-z NDT is similar to a radiotherapy medical accelerator, except the flattening filter and ion chamber have been removed to increase photon yields. In the accelerator head a 15 MeV electron beam is incident on a 1 cm thick tungsten slab to create bremsstrahlung photons with a continuous spectrum in the range 15 MeV. Primary photon fluence is defined as γ-rays created via target bremsstrahlung that do not interact anywhere further in the beam line to the scoring plane. Monte Carlo simulations were performed for 1 million input 15 MeV electrons and simulated interactions, trajectories, and particle showers using the EGS/BEAM code [ with processors on a Beowulf cluster. A scoring plane was placed at the end of the accelerator head to compute the

PIERS ONLINE, VOL. 7, NO. 8, 11 79 GB phase space file for the emerging 18 beam. The spectral density of the phase space particles in the central 1 cm of the beam, an area that defines a pencil beam for raysum measurements, was calculated. Figure 1 shows the spectral density for the pencil beam in which the primary photon spectrum is separated from electrons and positrons. There are energy cutoffs for photon (1 kev) and electron (.7 MeV) transport which force the spectrum to zero. The cutoffs are chosen based on the extremely short range of these particles in solids in order to speed-up the Monte Carlo simulation [. The charged particle cutoff is higher, but as can be seen in Figure 1, represents a very small percentage of the particles in the beam (and also would not have a significant range in steel). In order to compute the BHC in Eq. () an explicit expression for the normalized spectrum S n (E) is required, which was obtained from a six order polynomial fit to the spectrum shown in Figure 1... Steel Spectral Attenuation The energy-resolved steel spectral attenuation, µ(e), is also employed in Eq. (). This was derived using a series of EGS/BEAM Monte Carlo slab simulations with incident monoenergetic photons. Figure contains the resulting primary photon attenuation µ(e) for steel, which is appropriate if scatter has been removed via collimation. Also shown is a third order exponential fit to the data that is applied to the BHC calculation in Eq. ()..3. BHC Estimation The steel BHC versus thickness d is derived from the following equation BHC(d) = µ(5. MeV)d + ln S n (E)e µ(e)d de, (3) where S n (E) and µ(e) are given in Figures 1 and. The reference energy E = 5. MeV is somewhat arbitrary. Procedures for choosing E are discussed in the literature [1. Figure 3 shows the resulting steel BHC and an exponential fit to the function BHC(d), which is used for the applications to tomographic reconstructions in the next section. 3. APPLICATION OF BHC TO TOMOGRAPHIC RECONSTRUCTION In this section we apply the steel BHC in Figure 3 to tomographic reconstruction of steel cylinders and pipes. In order to obtain the necessary projection data via Monte Carlo simulation, we use a polychromatic photon pencil beam with the spectrum in Figure 1. The incident pencil beam had square areal dimensions with x = y =.1 cm half maxima. Projection data was obtained through a series of EGS/BEAM simulations with different incident offsets on the steel target. A scoring plane was placed behind a 19 cm lead collimator nearly two meters downstream from the steel targets. Latch bits were set to distinguish primary and scattered particles. The specific steps in generating projection data, applying the BHC, and performing CT reconstructions were as follows: 1) obtain projection data via independent multiple-offset pencil beam Figure 1: EGS/BEAM Monte Carlo simulation of 15 MeV accelerator head pencil beam spectral densities. Figure : Steel spectral attenuation in the range.5 15 MeV via EGS/BEAM Monte Carlo slab calculations.

PIERS ONLINE, VOL. 7, NO. 8, 11 793 Figure 3: Steel BHC versus thickness. 1 1 ln(n /N) 8 Interpolated ln (N /N) 8 without beam hardening correction with beam hardenig correction 8 1 1 1 Figure : Projection from EGS/BEAM simulations on steel cylinder with radius of 15 cm. -15-1 -5 5 1 15 Figure 5: Interpolation of projection data to uniform 5 point grid with and without the steel BHC. simulations using the phantom model, ) apply spline interpolation of projection data onto an equally spaced 5 sample grid to create a 5 5 reconstructed image, and 3) perform filtered back projection using the Siddon algorithm [5 with 18 one-degree separated beams for the uncorrected reconstruction. Alternatively, after step, we apply the BHC in Eq. (3) to projection data, and perform the same filtered back projection reconstruction to the BHC-processed projections to obtain corrected reconstructions. The results of these procedures for the steel cylinder and pipe are shown in the following sections. 3.1. Steel Cylinder The steel cylinder of 15 cm radius was constructed as an EGS/BEAM Monte Carlo phantom. For each offset.1.1 cm pencil beam, a total of N = million incident photons were chosen from the polychromatic spectrum in Figure 1. The offsets of the incident pencil beams in centimeters for the EGS/BEAM simulations were, 1,, 3,, 5,, 7, 8, 9, 1, 1.5, 11, 11.5, 1, 1.5, 13, 13., 13., 13., 13.8, 1, 1.1, 1., 1.3, 1., 1.5, 1., 1.7, 1.8, 1.9, 1.95, 15. In order to isolate beam hardening from scatter effects, latch bits were employed to count primary photons [. This count of exiting photons N at the scoring plane was obtained for each pencil beam. Figure shows the count plotted as ln(n /N) versus offset that defines the projection data. The interpolation of this function to a uniform grid is shown in Figure 5 with and without the application of the BHC in Eq. (3) using the appropriate thickness d of the steel cylinder at the corresponding offset. The magnitude of the BHC is significant, nearly a factor of 7. at the center of the cylinder. The filtered back projection reconstructions are shown in Figures and 7. The beam hardening artifact is prominent in Figure (a), and is completely removed in Figure (b) after the application of BHC. This is further illustrated in Figure 7 with a horizontal slice through the reconstructed images in Figure.

Fig 11 Fig 8 PIERS ONLINE, VOL. 7, NO. 8, 11 79 3.. Steel Pipe The second example we considered was a steel pipe of 13 cm inner radius and 15 cm outer radius. In order to boost photon yields and isolate beam hardening effects, the pipe phantom was set in a vacuum. Consequently, only N = 5 million photons were needed for each pencil beam simulation. This allowed dense beam offset sampling near the inner and outer edges of the pipe. The offsets (a) (b) Reconstructed attenuation µ/ρ..3..1. -15-1 -5 5 1 15 Figure : Tomographic reconstructions of steel cylinder from EGS/BEAM simulated projection in (a) without the BHC and (b) with the BHC. Figure 7: The red curve is from Figure (a) (without BHC) and the blue curve is from Figure (b) (with BHC). 5 ln(n /N) 5 3 1 Interpolated ln (N /N) 3 1 withouth beam hardening correction with beam hardening correction 8 1 1 1 Figure 8: Primary photon fluence projection from EGS/BEAM simulations on steel pipe of inner radius 13 cm and outer radius 15 cm. -15-1 -5 5 1 15 Figure 9: Projections interpolated onto equally spaced grid of 5 samples with and without the steel BHC..5 Reconstructed attenuation µ/ρ..3. (a) (b).1-15 -1-5 5 1 15 Figure 1: Tomographic reconstructions of steel pipe from EGS/BEAM projections. Figure 11: Horizontal slices through the reconstructions in Figure 1. The red curve is from Figure 1(a) (without BHC) and the blue curve is from Figure 1(b) (with BHC).

PIERS ONLINE, VOL. 7, NO. 8, 11 795 in centimeters were given by, 1,, 3,, 5,, 7, 8, 9, 9.5, 1, 1.5, 11, 11.5, 1, 1.5, 1.9, 13, 13.1, 13., 13.3, 13.5, 13.8, 1, 1., 1.5, 1., 1.7, 1.8, 1.9, and 15. We computed primary photon numbers at the scoring plane using appropriate latch bit filters. The resulting function ln(n /N) versus offset is plotted in Figure 8. Spline interpolation to a uniform grid was applied to the projection data, and the BHC in Eq. () was implemented for steel thickness d at the corresponding offset. The results shown in Figure 9 indicate a large correction in the pipe center and at the rim where the reconstruction is most delicate. Filtered back projection reconstructions from 18 one-degree views with the raysum estimates in Figure 9 are shown in Figure 1. The beam hardening artifact is apparent in Figure 1(a) and completely removed via the (Eq. (3)) BHC application in Figure 1(b). Figure 11 shows horizontal slices through the reconstructions in Figure 1 without (red) and with (blue) the BHC. Beam hardening is observed in the cupped signature towards the edge of the pipe image.. CONCLUSIONS The key inputs to high energy (> 1 MeV) beam hardening correction for nondestructive testing, incident photon spectral density and material spectral attenuation, were derived via first-principles Monte Carlo simulation. In this paper, the Monte Carlo-derived BHC was shown to remove beam hardening effects for steel cylinders and pipes. The overall reconstruction corrections were remarkably successful, but required dense edge sampling and interpolation via pencil beams. These may not be available in CT measurements and processing. Nevertheless, if there is prior knowledge of the accelerator head configuration and expected materials, it is possible to derive spectra from Monte Carlo simulation for BHC calculation. In our future research, we will fully simulate the BHC procedure by including simulated calibration curves that correlate the BHC factor with measured particle counts at the detector. REFERENCES 1. Kak, A. C. and M. Slaney, Principles of Computerized Tomographic Imaging, IEEE Press, New York, 1988.. Gao, H., L.Zhang, Z. Chen, Y. Xing, and S. Li, Beam hardening correction for middle-energy industrial computerized tomography, IEEE Trans. Nuclear Science, Vol. 53, 79 87,. 3. Jin, X., R. Y. Levine, and D. Reiss, Spectral feature of high energy photon scatter in high-z materials, IEEE Trans. Nucl. Sci., 11 (submitted for publication).. Rogers, D. W. O., B. A. Faddegon, G. X. Ding, C.-M. Ma, J. We, and T. R. Mackie, BEAM: A Monte Carlo code to simulate radiotherapy treatment units, Med. Phys., Vol., 53 5, 1995. 5. Siddon, R. L., Fast calculation of exact radiological path for a three-dimensional CT array, Med. Phys., Vol. 1, 5 55, 1985.