Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

Similar documents
itemp TMT180 Technical information

TMT470L Temperature Transmitter

4 â RIA251. Technical Information. Process display Digital loop powered display for ma current loops

Technical Information RIA16

WirelessHART Adapter SWA70

Technical Information RIA16

Paperless recorder Ecograph

RA33. Technical Information. Batch controller For the batching and dosing of mass and volume

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

EngyVolt RV12 and RV15

SITRANS T measuring instruments for temperature

MID approval no. DE-08-MI004-PTB004 Date of release

Process display RIA 251. Digital loop powered display for ma current loops. Application areas. Plant and machine construction.

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Technical Information Promonitor NRF560

LineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Inform IT Single Pen Circular Chart Recorder

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Precision hand-held pressure indicator Model CPH6400

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

1 Overview. Pressure Measurement Transmitters with WirelessHART. 1/36 Siemens FI US Edition. SITRANS P280 for gauge and absolute pressure

General information. Display. Supply voltage. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Wall-/Pipe Mounted Universal Process Indicator

Immersion Temperature Sensors

Color hybrid recorder alpha-log

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Data sheet Video Recorder LINAX A303

Industrial Power Supplies

Vert-X 05E 5V / % Ub. Application Access control systems Forklift

Contact protection relay

General information. Display. Supply voltage. Input current. Encoder supply. Output current

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

DI572 Digital Input Module

LineMaster 200. Continuous-line Recorder. ABB Instrumentation 10/ EN

MULTICHANNEL DATA RECORDERS

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

EC 600 Electronic Volume Corrector

Flow simulation system PROline FieldCheck

PointMaster 100. Multipoint Recorder 10/ EN

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

TRC-190 User s Manual

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

KiTorq Stator. Torque. Torque Evaluation Unit (Stator) for a Torque Measuring Flange. Type 4541A...

SITRANS P measuring instruments for pressure

Supplementary Components WirelessHART products

General information. Display. Supply voltage. Input current

Technical Information Liquiline To Go CYM290 and Liquiline To Go Ex CYM291

M5100 Heavy Industrial Pressure Transducer

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

Ecograph T. Technical Information. Multi Channel Recorder Display, record, communicate

General information. Display. Supply voltage

Installation Instructions Temperature transmitter TAA /00 06/2011

General information. Display. Supply voltage

System Components Surge Arrester HAW 261 and HAW 262

iologik E1200H Series

Ecograph A. Technical Information

C160 Wall-/Pipe Mounted Universal Process Indicator

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010

Compact Inductive Proximity Sensor

Hand-held thermometer Model CTH6200

FICHA TÉCNICA DE PRODUTO

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

DI561 Digital Input Module

T EN TROVIS Electropneumatic Positioner

Digital Indicator Solutions

PHOENIX CONTACT - 07/2006

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

Industrial Power Supplies

LineMaster 100 Continuous-line Recorder

MULTICHANNEL DATA RECORDERS

MODEL 9250 Preliminary data sheet

AI561 Analog Input Module

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

DC562, digital input/output module,

Series 3730 Type Electropneumatic Positioner

Signal conditioning instruments VEGASCAN 693. Product Information

General information Engineering with Programming package. Display with display

/8 DIN Universal Process Indicator

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Multi-functional precision thermometer CTR3000

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Technical Information Fieldgate SFG500

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

Transcription:

Technical Information Minilog RDL10 Measured value collector with 2 input channels for storing analog and digital values Application Data storage for termperature, humidity, pressure, flow, level, and analysis values Temperature monitoring: Storage and transport temperature measurement Operation time recording Access monitoring Piece part and quantity monitoring Quantity recording by integrating the analog signal Where measured values are to be automatically recorded and stored Start analog value recording using an external digital control signal ON/OFF signals are stored using date and time and displayed in Readwin 2000. Your benefits Variable sensor connections using 0/4 to 20 ma, 0 to 1 V or Pt100 as well as potential free contact for event or count impulses Instantaneous value or min-, max-, average value recording Measured value storage always includes date and time Storage of up to 64,000 measured values Presettable storage cycle (1 minute up to 24 hours) Stand alone battery powered unit or for external power supply available Robust (IP 65 / NEMA 4), small and economical User friendly setting up and data analysis using the Readwin 2000 software package Selectable display function TI00089R/09/EN 71138624

Function and system design Measuring principle Measuring system Set points Interface / Readwin 2000 software Data visualization The Minilog B, Version II data-logger records analog and digital measured values. The analog input signals can be 0/4 to 20 ma, 0 to 1 V and Pt100 resistive thermometers. In addition to the analog input there is also a digital input available. A potential free contact (or TTL-signal) can be connected to this input. This input records, for example, count impulses with a max. frequency of 25 Hz and 1 s at events. Alternatively this input can be used to, for example, calculate the running time of a particular piece of equipment or machine. The unit reads these values every second. From the values it calculated the instantaneous values or min, max and averages. The memory capacity is a max. 16,000 measured values (optionally max. 64,000 measured values) with a presettable storage cycle of 1 minute up to 24 hours. analog: Data-logger Minilog B, Version II and separate transmitters in 0/4 to 20 ma, 0 to 1 V and Pt100 technology digital: Data-logger Minilog B, Version II and potential free contact In addition to recording the data the data-logger also monitors two set points. These set points can be set up using the Readwin 2000 software package. Any infringement of these values is indicated in the display. A choice of whether to record continuously or only in the case of a set point infringement (in the preset storage cycle) is available and can be set up. Minilog B, Version II data-logger can be simply and easily set up using the RS232 interface. Simple and safe setting up is made possible by using the on-line help text. The Readwin 2000 software package is delivered with the unit free of charge. Interface cables for connection to a PC or Modem can be purchased as accessories. The recorded data can be read out, transmitted and displayed using the Readwin 2000 software package. The main features are: Common PC operating system Saving the unit settings in a database Instantaneous value display Min-/max-/average value display Quantities Events Read out of the values stored in the unit Measured value display in the form of traces, columns and tables Data export onto spread sheets (e.g. Excel, Lotus etc.) Printout of graphics, tables and unit parameters Readwin 2000 PC operating software R09-RDL10xx-20-01-00-en-000 2 Endress+Hauser

Measured variable! Note! Input Universal application analog: transmitter must have 0/4 to 20 ma, 0 to 1 V output signal or direct Pt100. digital: potential free contact or TTL peak 5 V DC Minilog B, Version II has no loop power supply. Power supply minus, GND connection (pin 4) of the interface, analog input minus (terminal 1) and terminal 5 of the digital input are internally connected. Number of inputs Analog input: 1 Digital input: 1 Terminal assignment Power supply Terminal assignment of the data-logger R09-RDL10xx-04-xx-xx-en-000 Supply voltage Lithium battery 3.6 V Type AA, optional Type C or external power supply 7 to 30 V DC, approx. 5 ma Battery life cycle Type AA (2.1 Ah) Type C (7.2 Ah) Monthly readout min. 2 years min. 5 years Continuous readout min. 1 month min. 2 month Endress+Hauser 3

Terminals Cable entries Termination on 2.5 mm 2 (14 AWG) terminals, 1.5 mm 2 (16 AWG) core with ferrule. Two-wire connection (three-wire on Pt100); connection access using 2x PG9 cable glands (optional 1x ½" NPT instead of 1x PG9) Performance characteristics Maximum measured error Analog input 0 to 1 V, R i 1M Accuracy ± 0.25 % FSD 0/4 to 20 ma, via shunt, R i = 50 Cable open circuit monitor < 2 ma (on 4 to 20 ma) Accuracy ± 0.25 % FSD Pt100, -100 to +400 ma, screened cable Accuracy ± 0.5 C (± 0.8 F), cable open circuit monitor Digital input 1 input using two terminals; f max = 25 Hz on pulses, 1 s on events; for potential free contact Long-term drift Influence of ambient temperature Time drift ± 50 ppm ( 30 min/year) Temperature drift ± 0.25 % / 10 K (± 0.14 % / 10 F) Installation Orientation Mounting kit The unit should be mounted vertically, for this a wall or stand pipe mounting kit can be ordered. Wall mounting Dimensions of the wall mounting plate R09-RDL10xx-06-00-06-xx-000 4 Endress+Hauser

Stand pipe mounting Dimensions of the stand pipe mounting plate R09-RDL10xx-06-00-06-xx-001 Environment Ambient temperature range Storage temperature Climate class Degree of protection Vibration resistance Electromagnetic compatibility -25 to +55 C (-13 to 131 F) -25 to +60 C (-13 to 140 F) IEC 654 Part 1 Class C1 IP 65 / NEMA 4 with closed cover IEC 654-3, v < 3 mm/s, 1<f<150 Hz RF protection To EN 55011 Group 1, Class B Interference safety ESD Electromagnetic fields Burst (supply cicuit) Burst (signal circuit) Surge HF discharge Normal mode noise rejection To EN 61000-4-2, Level 3, 6/8 kv To EN 61000-4-3, Level 3, 10 V/m To EN 61000-4-4, Level 3, 1 kv / 2 kv To EN 61000-4-4, Level 3, 1 kv To EN 61000-4-6, 10 V additional measurement accuracy 0.5 % 26 db at input range/10, f = 50/60 Hz, not on resistance measurement Endress+Hauser 5

Mechanical construction Design, dimensions Dimensions of the data-logger R09-RDL10xx-06-00-06-xx-002 Weight Materials 0.5 to 0.7 kg (1.1 to 1.5 lb), dependent on model Transmitter housing Aluminum die cast, surface galvanized Accessories Wall / stand pipe adapter: 1.4301 (304 SS) Strap: 1.4301 (304 SS) Operability Operating concept Local operation The device is operated using the Readwin 2000 operating software. Display LC display, 7 segment, prefix, decimal point, limit symbol, battery status symbol Display of the data-logger 1 Limit symbol R09-RDL10xx-07-xx-xx-xx-000 Remote operation Readwin 2000 software package for setting up, transmission and display of measured data. Download under www.readwin2000.com 6 Endress+Hauser

Certificates and approvals CE mark Guide lines 2004/108/EG Ordering information Product structure RDL10 Data-logger Minilog B, Version II Power Supply: R Battery 3.6V 2.1Ah T 7-30VDC, (w/o battery) U Prepared for battery 3.6V 7.2Ah (w/o battery) Y Special version, TSP-no. to be spec. Input; Software: 1 0/4-20mA 0-1VDC Pt100; standard 2 W/o E+H label, 0/4-20mA 0-1VDC Pt100, basic software 3 0/4-20mA 0-1VDC Pt100; telealarm + GSM cable, w/o digital input, only 24VDC version 4 W/o E+H label, telealarm + GSM cable, 0/4-20mA 0-1VDC Pt100 w/o digital input, only 24VDC version 9 Special version, TSP-no. to be spec. Internal memory: B 32K, max 16000x meas. value C 128K max 64000x meas. value F Works calib. certif., 32K G Works calib. certif., 128K Y Special version, TSP-no. to be spec. Temperature Sensor: 1 Not selected 2 Incl. Pt100, -25...+55oC, PG gland 9 Special version, TSP-no. to be spec. Cable Entry: A Gland PG9 B Gland PG9 + Lead seal option C Thread NPT1/2 D Thread NPT1/2 + Lead seal option Y Special version, TSP-no. to be spec. Additional Option: 1 Basic version 2 Mounting bracket, wall 3 Mounting bracket, pipe 4 RS232 cable 5 Mounting bracket, wall + RS232 cable 6 Mounting bracket, pipe + RS232 cable 9 Special version, TSP-no. to be spec. Customer requirements: L Board varnished, mounted in ASP2000 M Board varnished Z Special version, TSP-no. to be spec. Marking: A Tagging (TAG), metal B Tagging (TAG), on device C Commissioning label, paper F Tagging (TAG), by customer RDL10- Order code complete Endress+Hauser 7

Scope of delivery The following is included in the delivery: Built-in lithium battery (only for version with 3.6 V / 2.1 Ah battery), operating manual, mounted cable glands, PC software package Readwin 2000. Device-specific accessories Accessories Description Order no. Interface cable without software 50086167 Interface cable for MODEM with adapter RDL10A-VL Mounting bracket cpl. for wall mounting 51000946 Mounting bracket/pipe mounting/complete 51000924 Battery (Lithium) Typ AA, 3.6 V / 2.1 Ah 51000981 Battery (Lithium) Typ C, 3.6 V / 7.2 Ah Adapter set for connection of two Minilog B to one modem Can be ordered from: http://www.tadiranbat.com/index.php/ tadiran-international-distributors RDL10A-AA Documentation Standard documentation Recorder and data acquisition technology brochure: Data managers, paperless recorders and associated software packages: FA014R/09 Operating instructions Minilog B, RDL10: BA00123R/09 Instruments International Endress+Hauser Instruments International AG Kaegenstrasse 2 4153 Reinach Switzerland Tel.+41 61 715 81 00 Fax+41 61 715 25 00 www.endress.com info@ii.endress.com TI00089R/09/EN/01.11 71138624 FrameMaker 9 ProMoDo