Micro-CT Methodology Hasan Alsaid, PhD

Similar documents
Ch. 4 Physical Principles of CT

MEDICAL EQUIPMENT: COMPUTED TOMOGRAPHY. Prof. Yasser Mostafa Kadah

CLASS HOURS: 4 CREDIT HOURS: 4 LABORATORY HOURS: 0

Applying Hounsfield unit density calibration in SkyScan CT-analyser

XRADIA microxct Manual

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

Empirical cupping correction: A first-order raw data precorrection for cone-beam computed tomography

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Computer-Tomography I: Principles, History, Technology

BME I5000: Biomedical Imaging

DUE to beam polychromacity in CT and the energy dependence

Shadow casting. What is the problem? Cone Beam Computed Tomography THE OBJECTIVES OF DIAGNOSTIC IMAGING IDEAL DIAGNOSTIC IMAGING STUDY LIMITATIONS

TEP Hounsfield units. Related topics Attenuation coefficient, Hounsfield units

S. Guru Prasad, Ph.D., DABR

Assessment of 3D performance metrics. X-ray based Volumetric imaging systems: Fourier-based imaging metrics. The MTF in CT

Introduction to Biomedical Imaging

Lorad FFDM QC Procedures for Medical Physicist. Tao Wu, Ph.D. Hologic, Inc.

SYSTEM LINEARITY LAB MANUAL: 2 Modifications for P551 Fall 2013 Medical Physics Laboratory

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

Fundamentals of CT imaging

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

LAB DEMONSTRATION COMPUTED TOMOGRAPHY USING DESKCAT Lab Manual: 0

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

Corso di laurea in Fisica A.A Fisica Medica 4 TC

CT vs. VolumeScope: image quality and dose comparison

Loma Linda University Medical Center Dept. of Radiation Medicine

Inveon User Notes. Inveon Scanners and Inveon Acquisition Workplace 2.0

James R Halama, PhD Loyola University Medical Center

Annexure XII SPECIFICATIONS FOR A NEW STATE OF ART 16 SLICE ALL PURPOSE C. T. SCANNER

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

Spectral analysis of non-stationary CT noise

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Photon counting spectral CT versus conventional CT: comparative evaluation for breast imaging application

Slide 1. Technical Aspects of Quality Control in Magnetic Resonance Imaging. Slide 2. Annual Compliance Testing. of MRI Systems.

Conflicts of Interest Nuclear Medicine and PET physics reviewer for the ACR Accreditation program

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

CT Basics Principles of Spiral CT Dose. Always Thinking Ahead.

SPECT QA and QC. Bruce McBride St. Vincent s Hospital Sydney.

MEDICAL IMAGING 2nd Part Computed Tomography

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

Agenda : Lung Density Breakout Session

Porosity and Pore-Size Distribution of Geomaterials from X-Ray CT Scans

How does the ROI affect the thresholding?

MEDICAL IMAGING 2nd Part Computed Tomography

Image Acquisition Systems

8/7/2017. Disclosures. MECT Systems Overview and Quantitative Opportunities. Overview. Computed Tomography (CT) CT Numbers. Polyenergetic Acquisition

Computer-Tomography II: Image reconstruction and applications

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Lucy Phantom MR Grid Evaluation

Digital Image Processing

NumaStore Preclinical FAQ

CT: Physics Principles & Equipment Design

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

Correlation between Model and Human Observer Performance on a Lesion Shape Discrimination Task in CT

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

Tomographic Reconstruction

Financial disclosure. Onboard imaging modality for IGRT

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

Quality control phantoms and protocol for a tomography system

QIBA PET Amyloid BC March 11, Agenda

Modifications for P551 Fall 2014

PLANMECA PROMAX 3D MID CBCT UNIT

Superior Imaging on the Go

Optimisation of Toshiba Aquilion ONE Volume Imaging

icatvision Quick Reference

CT Protocol Review: Practical Tips for the Imaging Physicist Physicist

AAPM Standard of Practice: CT Protocol Review Physicist

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc.

CT Protocol Clinical Graphics Move Forward 3D motion analysis service

INTERNATIONAL STANDARD

Improvement of contrast using reconstruction of 3D Image by PET /CT combination system

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Superior Imaging on the Go

A closer look at CT scanning

1.1. FireCR Calibration

DUAL energy CT (DECT) is a modality where one and. Empirical Dual Energy Calibration (EDEC) for Cone-Beam Computed Tomography

Planmeca ProMax 3D Max CBCT unit

Enhancement Image Quality of CT Using Single Slice Spiral Technique

Enhanced material contrast by dual-energy microct imaging

Deviceless respiratory motion correction in PET imaging exploring the potential of novel data driven strategies

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Discontinued Products

Diagnostic quality of time-averaged ECG-gated CT data

Cardiac Dual Energy CT: Technique

Multigrid Reconstruction of Micro-CT Data

CT Systems and their standards

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

DUAL-ENERGY CT IN PROTON THERAPY

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

[PDR03] RECOMMENDED CT-SCAN PROTOCOLS

Contrast Enhancement with Dual Energy CT for the Assessment of Atherosclerosis

Effects of the difference in tube voltage of the CT scanner on. dose calculation

Recognition and Measurement of Small Defects in ICT Testing

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

Medical Image Processing: Image Reconstruction and 3D Renderings

Transcription:

Micro-CT Methodology Hasan Alsaid, PhD Preclinical & Translational Imaging LAS, PTS, GlaxoSmithKline 20 April 2015

Provide basic understanding of technical aspects of the micro-ct Statement: All procedures were approved by the Animal Care and Use Committee of GlaxoSmithKline and were specifically designed to minimize animal discomfort. Agenda: 1. Introduction to key parameters for a typical (Acquisition) protocol. 2. Description of the 3-D image reconstruction process. 3. Necessary calibrations. 4. Inclusion of phantoms as a control. 5. How are images acquired, reconstructed and analyzed? 6. Computer settings and image storage. 2

Key parameters for typical CT Acquisition protocols System parameters: X-ray tube setup: x-ray flux Voltage (kvp) & Current (ua): Higher voltages are used for denser or larger subjects; lower voltages are used for less dense or smaller subjects. The x-ray flux is proportional to the square of the operating voltage. The x-ray flux is directly proportional to the anode current. Filter thickness: filter the low energy x-rays. Detector (camera) setup: Binning: higher binning increases the effective pixel size and reduces the size of the data set. Exposure time (ms): for each exposure. Field of View (FOV): - Detector readout: active part of the detector. - System magnification.

Key parameters for typical CT Acquisition protocols System parameters: CT Setup: Rotating start position. Total rotation: total angle of rotation. Rotation steps: number of rotation steps to complete the total rotation. Dataset file size: Number of rotations. Binning. FOV. Image reconstruction: down sampling. Data format. Inveon preclinical CT, Siemens Medical Solutions

Image acquisition and reconstruction Schematic illustration of CT scan generations Image reconstruction is a mathematical process generating images from data acquired at many different angles around the subject. Image reconstruction impacts image quality & radiation dose. * Image Reconstruction Techniques, Yu and Leng, NOVEMBER 2010 / WWW.IMAGEWISELY.ORG 5

Quality Control & Necessary Calibrations X-ray flux X-ray flux is not stable X-ray flux is stable Center offset: Distance between the center of the detector and the scanner iso center. CT Hounsfield Unit calibration: the radio density of distilled water and air at standard pressure and temperature is 0 and -1000 respectively. Stitching calibration for multi bed positions. Dark and light calibration: Increasing the number reduces the noise of these frames, improving soft tissue contrast and reducing ring artifacts. System QC: daily, weekly, quarterly.

Inclusion of phantoms as a control 1. What do we need a phantom to address? The position and alignment: center offset, stitching (phantom should cover multi bed positions). CT HU accuracy: Air, Water, Bone,... presented as Mean ± SD. Assess the low and the high spatial resolutions: series of cylinders of a known material/contrast with different diameters. CT homogeneity for both resolution and contrast: should be measured in the center and in the periphery of the cylinder phantom. 2. What do we need to capture? Water Air Low density material Bone CT phantom images. CT phantom data. * http://www.acr.org/~/media/acr/documents/accreditation/ct/phantomtestinginstruction.pdf

How are images acquired, reconstructed and analyzed? Acquisition Workstation Image Analysis Workstations Inveon CT scanner (Siemens Medical Solutions) Reconstruction Workstation Server (PACS) *PACS: Picture Archiving and communication system.

Computer settings and image storage Computer settings: High performance workstation for image analysis of 3D data : High performance CPU (with integrated memory). Large/high speed hard disk. Large memory RAM. High performance graphic card (with integrated memory). Image analysis software: qualitative / quantitative measurements. Data Storage: Data needs to be organized in a standard form: sample number/dataset number, study number, study date, imaging session. Image should be converted to a standard format DICOM*, AVI... QC may be performed on the data before or after moving it to the server/pacs. *DICOM: Digital Images and communications in Medicines.

Preclinical & Translational imaging Tinamarie Skedzielewski Beat Jucker, PhD Thank you Reproductive and Developmental Toxicology Stacia Murzyn Joyce Rendemonti Sharon Chapman Howard Solomon, PhD