CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Similar documents
CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2657A-LIM-3 LO Interconnect Module

HV-CS kv Edge Mount Triaxial Jack

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

Model 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1

2260B-RMK-Series Rack Mount Kit

Model 2380 Rack-Mount Kit

Model 7705 Control Module

Model 2380 Rack-Mount Kit

Model 8010 High Power Device Test Fixture Interconnection Reference Guide

Safety Precautions A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring.

Series 370 S SoftwSystem are Qui Switch/Mult ck Start G imeter uide Quick Start Guide

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Startup Software Quick Start Guide

Model GHz 50 Ohm RF Module

Model 7701 Multiplexer Module

Model Channel High Voltage Multiplexer Card

Models 2634B, 2635B, and 2636B System SourceMeter Instruments Quick Start Guide

Series 2600A System SourceMeter

S530 Parametric Test System

Models 707B and 708B Switching Matrix

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

Model 7700 Multiplexer Module

Model 2440 Service Manual Rev. B / December 2004

Model 2450 Interactive SourceMeter Instrument

2281S Precision DC Supply and Battery Simulator Quick Start Guide

Model 8101-PIV Test Fixture User s Guide. Overview. SMU Device holder (near latch) Two Leaded Part Plungers. PIV Device holder (near hinge)

KPXI 3U Instrument Chassis

Model 2701 Ethernet-Based DMM / Data Acquisition System

Model 2700 Multimeter/Data Acquisition System Service Manual

Model DAQ6510 Quick Start Guide

Series 3700 System Switch/Multimeter

Model 2000-SCAN Scanner Card

Model 2001 Multimeter

Model kw Pulse Mode Interactive

700 Series 200 Amp Clamp Meters

OPERATING MANUAL FOR THE 30KV A.C. TEST SET P123. Bicotest High Voltage Products Ltd

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model DAQ6510 Data Acquisition and Multimeter System

Series 3700 Screw Terminal Assemblies Installation Instructions

POCKET MULTIMETER Model No: MM18

Autoranging True RMS Multimeter User Manual

OPERATING INSTRUCTION

Model 2010 Multimeter Service Manual Rev. D / October 2003

User Guide True RMS Multimeter Extech EX205T

Mini Digital Multimeter

Agilent Technologies E5346A 38-Pin Probe and E5351A 38-Pin Adapter Cable

9040/9040UK. Users Manual. Phase Rotation Indicator

Mini Digital Multimeter

Model 3750 Multifunction I/O Card

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

PCT2000. User Manual. Precision current transducer 2000 A

Line Impedance Stabilization Network (LISN)

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

DM3058/DM3058E Digital Multimeter

Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement

Model /2-Digit Resolution Digital Multimeter

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Autoranging Mini Multimeter

Model 9140A-PCA Probe Card Adapter

Agilent Technologies E5385A 100-Pin Probe

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Model 610C, 610CR Solid-State Electrometers Instruction Manual

AutoRanging Digital MultiMeter

ETHOS Auto Ranging Digital Multimeter

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

User's Guide. Digital Multimeter. Model MN42

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

Agilent 34401A 6½ 桁マルチメータ ユーザーガイド

Model R5010. TRMS Digital Multimeter. Instruction Manual

2016 SIGLENT TECHNOLOGIES CO.,LTD

DS1000B Series Digital Oscilloscope

User's Guide. Extech AM A AC Analog Clamp Meter

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Mini Digital Multimeter

P5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Digital ac/dc (24V) Input Module

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

Mini Digital Multimeter Model MN15. User's Guide

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

TETRIS 2500 High Impedance Active Probe. Instruction Manual

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

PCT200. User Manual. Precision current transducer 200 A

Model A Mini AC/DC Clamp Meter. User's Guide

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

* * Agilent Power Distribution Unit (PDU) Installation Guide

INSTRUCTION MANUAL. * Design and Specifications are subject to change without notice. ver. 1.0 PRINTED IN KOREA

PT30-10C mk2 with Current Limit

Transcription:

Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-3K-KIT 3 kv Bias Tee Kit Description The CVU-3K-KIT Bias Tee Kit consists of three bias tees for performing high voltage (up to 3 kv) capacitance-voltage (C-V) measurements using Series 2600 and 4200 SMUs along with the Model 4210-CVU Capacitance-Voltage Instrument. Each bias tee combines C-V measurement with DC bias while isolating the C-V instrument and SMU instrument from each other. Figure 1: CVU-3K-KIT contents Parts list The following table lists the parts that are supplied with the CVU-3K-KIT. Part number Description Quantity 131936100 SMA (M) to SMB (M) Adapter 6 131936200 SMA (F) to SMB (F) Adapter 4 2600-RBT-200 200 V Bias Tee 2 2650-RBT-3K 3 KV Bias Tee 1 386782100 Remote Bias Tee Mounting Bracket 1 7078-TRX-1 3-Slot Triaxial Cable, 1 ft 2 8020-DP High Voltage Discharge Probe 1 CA-406B 50 Ω M-M SMA Cable, 33 cm 1 CA-568-120 Ground Cable, 120 in. 2 CS-1391 SMA Tee Adapter, F-M-F 2 HV-CA-554-.5 HV Triaxial Cable,.5 m, Male to Male 1 071321100 / October 2014 *P071321100* 1

Assembly and dimensions Figure 2: CVU-3K-KIT dimensions 2 071321100 / October 2014

You must connect both of the included CA-568-120 grounding cables to the safety ground studs of the bias tee mounting bracket. See the following graphic for an example. Figure 3: Bias tee mounting bracket with CA-568-120 grounding cable connection example Bias tee theory and overview The bias tee and device capacitance must be discharged with the included Model 8020-DP discharge probe. Refer to the Model 8010 High Power Device Test Fixture User's Manual for discharge instructions. 071321100 / October 2014 3

The bias tees in the CVU-3K-KIT are intended for use with the Model 8010 High Power Device Test Fixture. When not used with the Model 8010, you must connect Model 2657A-PM-200 external protection modules in series with the 2600-RBT-200 bias tees. The CVU-3K-KIT bias tees combine C-V measurement with DC bias while isolating the C-V instrument and SMU instrument from each other. The CVU-3K-KIT bias tee option has multiple operation modes that optimize the performance for each measurement type while nearly eliminating measurement configuration changes between DC I-V and C-V measurements. Additionally, the bias tees are fully guarded and configured for triaxial connections so that the low current DC measurements may be performed through the bias tee (see the following figure). Figure 4: 8020-CVU single bias tee block diagram 4 071321100 / October 2014

Bias tee modes Mode Application Block diagram I-V mode C-V mode Use for best DC low-current measurement performance. Ideal for any DC measurements made with the CVU-3K-KIT installed. DC currents up to 1 A are permissible in this mode. Example tests: Idss, Vds-Id Use for C-V measurements with a maximum DC bias current of 100 µa. Frequency range of 10 khz - 2 MHz possible. 2 Example tests: Ciss, Coss I-V mode Control voltage 1 0 V (default state) AC switch state AC guard switch state DC switch state Open Open Closed C-V mode -10 V Closed Open Open C-V HI I mode Use for C-V measurements with a maximum DC bias current of 1 A. Frequency range of ~100 khz - 2 MHz possible. 3 Not for low current DC measurements. Example tests: Ciss, Coss C-V HI I mode +10 V Closed Open Closed AC guard Use for measuring capacitance between two terminals of a device with three or more terminals. This mode guards capacitance to third terminal by shunting AC current away from the AC measurement circuit. Example tests: Cgd, Cgs, Cds AC guard +12 V 4 Closed Closed Closed 1 The control voltage is a DC voltage driven at the AC input of the bias tee. Each control voltage must be maintained within ± 250 mv. A minimum drive current of 15 ma is required to close any of the desired switches. 2 Dependent on test system inductance. 3 Dependent on test system inductance. 4 Must be supplied by an external power source. HV C-V measurement software ACS Basic Edition software version 2.1 (or higher) includes a large device test library and automatically controls bias tee modes with each test. For example, the software programs the bias-connected tee mode to I-V mode before measuring the Idss (drain-to-source current) test of a FET. For Ciss (input capacitance) measurement of a power MOSFET, the software programs the bias tee for C-V mode. 071321100 / October 2014 5

Safety precautions The following safety precautions should be observed before using this product and any associated instrumentation. Although some instruments and accessories would normally be used with nonhazardous voltages, there are situations where hazardous conditions may be present. This product is intended for use by qualified personnel who recognize shock hazards and are familiar with the safety precautions required to avoid possible injury. Read and follow all installation, operation, and maintenance information carefully before using the product. Refer to the user documentation for complete product specifications. If the product is used in a manner not specified, the protection provided by the product warranty may be impaired. The types of product users are: Responsible body is the individual or group responsible for the use and maintenance of equipment, for ensuring that the equipment is operated within its specifications and operating limits, and for ensuring that operators are adequately trained. Operators use the product for its intended function. They must be trained in electrical safety procedures and proper use of the instrument. They must be protected from electric shock and contact with hazardous live circuits. Maintenance personnel perform routine procedures on the product to keep it operating properly, for example, setting the line voltage or replacing consumable materials. Maintenance procedures are described in the user documentation. The procedures explicitly state if the operator may perform them. Otherwise, they should be performed only by service personnel. Service personnel are trained to work on live circuits, perform safe installations, and repair products. Only properly trained service personnel may perform installation and service procedures. Keithley Instruments products are designed for use with electrical signals that are measurement, control, and data I/O connections, with low transient overvoltages, and must not be directly connected to mains voltage or to voltage sources with high transient overvoltages. Measurement Category II (as referenced in IEC 60664) connections require protection for high transient overvoltages often associated with local AC mains connections. Certain Keithley measuring instruments may be connected to mains. These instruments will be marked as category II or higher. Unless explicitly allowed in the specifications, operating manual, and instrument labels, do not connect any instrument to mains. Exercise extreme caution when a shock hazard is present. Lethal voltage may be present on cable connector jacks or test fixtures. The American National Standards Institute (ANSI) states that a shock hazard exists when voltage levels greater than 30 V RMS, 42.4 V peak, or 60 VDC are present. A good safety practice is to expect that hazardous voltage is present in any unknown circuit before measuring. Operators of this product must be protected from electric shock at all times. The responsible body must ensure that operators are prevented access and/or insulated from every connection point. In some cases, connections must be exposed to potential human contact. Product operators in these circumstances must be trained to protect themselves from the risk of electric shock. If the circuit is capable of operating at or above 1000 V, no conductive part of the circuit may be exposed. Do not connect switching cards directly to unlimited power circuits. They are intended to be used with impedance-limited sources. NEVER connect switching cards directly to AC mains. When connecting sources to switching cards, install protective devices to limit fault current and voltage to the card. Before operating an instrument, ensure that the line cord is connected to a properly-grounded power receptacle. Inspect the connecting cables, test leads, and jumpers for possible wear, cracks, or breaks before each use. When installing equipment where access to the main power cord is restricted, such as rack mounting, a separate main input power disconnect device must be provided in close proximity to the equipment and within easy reach of the operator. For maximum safety, do not touch the product, test cables, or any other instruments while power is applied to the circuit under test. ALWAYS remove power from the entire test system and discharge any capacitors before: connecting or disconnecting cables or jumpers, installing or removing switching cards, or making internal changes, such as installing or removing jumpers. Do not touch any object that could provide a current path to the common side of the circuit under test or power line (earth) ground. Always make measurements with dry hands while standing on a dry, insulated surface capable of withstanding the voltage being measured.

For safety, instruments and accessories must be used in accordance with the operating instructions. If the instruments or accessories are used in a manner not specified in the operating instructions, the protection provided by the equipment may be impaired. Do not exceed the maximum signal levels of the instruments and accessories, as defined in the specifications and operating information, and as shown on the instrument or test fixture panels, or switching card. When fuses are used in a product, replace with the same type and rating for continued protection against fire hazard. Chassis connections must only be used as shield connections for measuring circuits, NOT as protective earth (safety ground) connections. If you are using a test fixture, keep the lid closed while power is applied to the device under test. Safe operation requires the use of a lid interlock. If a screw is present, connect it to protective earth (safety ground) using the wire recommended in the user documentation. The symbol on an instrument means caution, risk of danger. The user must refer to the operating instructions located in the user documentation in all cases where the symbol is marked on the instrument. The symbol on an instrument means caution, risk of electric shock. Use standard safety precautions to avoid personal contact with these voltages. The symbol on an instrument shows that the surface may be hot. Avoid personal contact to prevent burns. The symbol indicates a connection terminal to the equipment frame. If this symbol is on a product, it indicates that mercury is present in the display lamp. Please note that the lamp must be properly disposed of according to federal, state, and local laws. The WARNING heading in the user documentation explains dangers that might result in personal injury or death. Always read the associated information very carefully before performing the indicated procedure. The CAUTION heading in the user documentation explains hazards that could damage the instrument. Such damage may invalidate the warranty. Instrumentation and accessories shall not be connected to humans. Before performing any maintenance, disconnect the line cord and all test cables. To maintain protection from electric shock and fire, replacement components in mains circuits including the power transformer, test leads, and input jacks must be purchased from Keithley Instruments. Standard fuses with applicable national safety approvals may be used if the rating and type are the same. Other components that are not safety-related may be purchased from other suppliers as long as they are equivalent to the original component (note that selected parts should be purchased only through Keithley Instruments to maintain accuracy and functionality of the product). If you are unsure about the applicability of a replacement component, call a Keithley Instruments office for information. To clean an instrument, use a damp cloth or mild, water-based cleaner. Clean the exterior of the instrument only. Do not apply cleaner directly to the instrument or allow liquids to enter or spill on the instrument. Products that consist of a circuit board with no case or chassis (e.g., a data acquisition board for installation into a computer) should never require cleaning if handled according to instructions. If the board becomes contaminated and operation is affected, the board should be returned to the factory for proper cleaning/servicing. Safety precaution revision as of January 2013.