Curve Correction in Atomic Absorption

Similar documents
Agilent MicroLab Quant Calibration Software: Measure Oil in Water using Method IP 426

Transfer and Manipulation of Atomic Absorption Data Using An IBM PC/AT LOTUS Software and Agilent SpectrAA-40 Spectrometer

UV-6 Series Double Beam UV/Vis Spectrophotometers

1

Using Excel for Graphical Analysis of Data

Agilent ChemStation for UV-visible Spectroscopy

Countdown to your final Maths exam part 8 (2017) Examiners Report & Markscheme

Retention Time Locking with the MSD Productivity ChemStation. Technical Overview. Introduction. When Should I Lock My Methods?

Using Adjustable Slits to Reduce Interfering Element Effects

Graphical Analysis of Data using Microsoft Excel [2016 Version]

UV / VIS SPECTROPHOTOMETER

Implicit Curvilinear Interpolation

Planting the Seeds Exploring Cubic Functions

D-Optimal Designs. Chapter 888. Introduction. D-Optimal Design Overview

Chapter 5 Accumulating Change: Limits of Sums and the Definite Integral

SELECTION OF A MULTIVARIATE CALIBRATION METHOD

Using Excel for Graphical Analysis of Data

Chapter 5. Track Geometry Data Analysis

Error Analysis, Statistics and Graphing

Keyword: Quadratic Bézier Curve, Bisection Algorithm, Biarc, Biarc Method, Hausdorff Distances, Tolerance Band.

FUNCTIONS AND MODELS

Integrated Math I. IM1.1.3 Understand and use the distributive, associative, and commutative properties.

Bootstrapping Method for 14 June 2016 R. Russell Rhinehart. Bootstrapping

Four equations are necessary to evaluate these coefficients. Eqn

Curve fitting. Lab. Formulation. Truncation Error Round-off. Measurement. Good data. Not as good data. Least squares polynomials.

CCSSM Curriculum Analysis Project Tool 1 Interpreting Functions in Grades 9-12

Standard Operating Procedure for the Horiba FluroMax-4

WESTMORELAND COUNTY PUBLIC SCHOOLS Integrated Instructional Pacing Guide and Checklist Algebra, Functions & Data Analysis

DesignDirector Version 1.0(E)

1. Assumptions. 1. Introduction. 2. Terminology

Using Graphical Analysis This exercise will familiarize you with using Graphical Analysis in Beer s Law and kinetics.

Mathematical Methods 2019 v1.2

specular diffuse reflection.

Exercise: Graphing and Least Squares Fitting in Quattro Pro

Part I, Chapters 4 & 5. Data Tables and Data Analysis Statistics and Figures

3.7. Vertex and tangent

round decimals to the nearest decimal place and order negative numbers in context

Agilent EZChrom Elite. PDA Analysis

Objectives and Homework List

f( x ), or a solution to the equation f( x) 0. You are already familiar with ways of solving

Development of an Electronic Technique for Determining Rate of Solution of Solid Products

Reading: Graphing Techniques Revised 1/12/11 GRAPHING TECHNIQUES

One of the most important areas where quantifier logic is used is formal specification of computer programs.

Rational Functions Video Lecture. Sections 4.4 and 4.5

Assignment 2. with (a) (10 pts) naive Gauss elimination, (b) (10 pts) Gauss with partial pivoting

CHAPTER 6. The Normal Probability Distribution

Lecture 8. Divided Differences,Least-Squares Approximations. Ceng375 Numerical Computations at December 9, 2010

UV WinLab Software The Lambda Series

MEI STRUCTURED MATHEMATICS. MEI conference University of Hertfordshire June C3 COURSEWORK

To Plot a Graph in Origin. Example: Number of Counts from a Geiger- Müller Tube as a Function of Supply Voltage

7 Fractions. Number Sense and Numeration Measurement Geometry and Spatial Sense Patterning and Algebra Data Management and Probability

( ) = Y ˆ. Calibration Definition A model is calibrated if its predictions are right on average: ave(response Predicted value) = Predicted value.

Visual Formula, Important Graphs, Inequalities, and Other Things

VW 1LQH :HHNV 7KH VWXGHQW LV H[SHFWHG WR

Thermo Scientific Spectronic 200 Visible Spectrophotometer. The perfect tool. for routine measurements

LOESS curve fitted to a population sampled from a sine wave with uniform noise added. The LOESS curve approximates the original sine wave.

Math 1525: Lab 4 Spring 2002

DOWNLOAD PDF BIG IDEAS MATH VERTICAL SHRINK OF A PARABOLA

Week 2: Frequency distributions

5 Classifications of Accuracy and Standards

Intermediate Algebra. Gregg Waterman Oregon Institute of Technology

Multivariate Calibration Quick Guide

Math 182. Assignment #4: Least Squares

Surveying Prof. Bharat Lohani Indian Institute of Technology, Kanpur. Lecture - 1 Module - 6 Triangulation and Trilateration

Component Level Prediction Versus System Level Measurement of SABER Relative Spectral Response

Solutions. Algebra II Journal. Module 2: Regression. Exploring Other Function Models

Experiment 5: Exploring Resolution, Signal, and Noise using an FTIR CH3400: Instrumental Analysis, Plymouth State University, Fall 2013

Introduction: Equipment: Getting Started Collecting the data:

Spectrophotometric Methods of Refractive Indices Measurement

1.2 Numerical Solutions of Flow Problems

Ingredients of Change: Nonlinear Models & 2.1 Exponential Functions and Models

Activity 7. The Slope of the Tangent Line (Part 2) Objectives. Introduction. Problem

McGill University - Faculty of Engineering Department of Electrical and Computer Engineering

End-of-Module Assessment Task

Calculus I Review Handout 1.3 Introduction to Calculus - Limits. by Kevin M. Chevalier

MATHEMATICS SYLLABUS SECONDARY 5th YEAR

EC121 Mathematical Techniques A Revision Notes

FUNCTIONS AND MODELS

Montana Instructional Alignment HPS Critical Competencies Mathematics Honors Pre-Calculus


Geology Geomath Estimating the coefficients of various Mathematical relationships in Geology

Experiments with Edge Detection using One-dimensional Surface Fitting

Chapter 12: Quadratic and Cubic Graphs

Agilent ChemStation for UV-Visible Spectroscopy

Approximating Square Roots

Upholding Ethics and Integrity: A macro-based approach to detect plagiarism in programming

Supplemental 1.5. Objectives Interval Notation Increasing & Decreasing Functions Average Rate of Change Difference Quotient

Graph Theory Day Four

Hopalong Fractals. Linear complex. Quadratic complex

Honors Precalculus: Solving equations and inequalities graphically and algebraically. Page 1

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

PR3 & PR4 CBR Activities Using EasyData for CBL/CBR Apps

An Intelligent Method for Searching Metadata Spaces

Area and Perimeter EXPERIMENT. How are the area and perimeter of a rectangle related? You probably know the formulas by heart:

Evaluation Method of Surface Texture on Aluminum and Copper Alloys by Parameters for Roughness and Color

Lecture 5. If, as shown in figure, we form a right triangle With P1 and P2 as vertices, then length of the horizontal

a) y = x 3 + 3x 2 2 b) = UNIT 4 CURVE SKETCHING 4.1 INCREASING AND DECREASING FUNCTIONS

A4.8 Fitting relative potencies and the Schild equation

In this course we will need a set of techniques to represent curves and surfaces in 2-d and 3-d. Some reasons for this include

This handout will discuss three kinds of asymptotes: vertical, horizontal, and slant.

Transcription:

Curve Correction in Atomic Absorption Application Note Atomic Absorption Authors B. E. Limbek C. J. Rowe Introduction The Atomic Absorption technique ultimately produces an output measured in optical units typically, in absorbance units. The operator must somehow convert this absorbance to concentration units in order to obtain the analytical result. The absorbance would ideally be linear with concentration if the Beer-Lambert Law could be applied exactly, but in practice there is always some deviation. Even within a limited concentration range, calibration curvature is the rule rather than the exception. Some of the causes of this curvature are controlled by the instrument design or by the experimental conditions used. The degree of curvature for nickel at the 232.0 nm wavelength, for instance, is controlled by the spectral bandwidth chosen on the monochromator, because the curvature arises from overlap of a nearby nonabsorbed line in the nickel spectrum. At practical instrument settings, it is not possible to eliminate this curvature completely. There are also more fundamental causes for calibration curvature, relating to the degree of overlap in the Voigt profiles of the emission and absorption lines. Curvature from such causes is not under the control of the operator, and since it varies from element to element, it cannot be completely removed in instrument design. Thus it is not possible to avoid the curvature, and various curve-fitting devices have been developed to compensate for the curvature and produce calibrated concentration output from atomic absorption instruments. Naturally, recent efforts in this direction have been aided by computer and microcomputer technology. The problem is to produce a suitable mathematical algorithm which matches the natural calibration curve as closely as possible, so that after initial set-up the concentration can be computed numerically from the measured absorbance.

Investigations In investigating suitable algorithms, we first considered the known practical constraints: 1. The algorithm must be accurate within 1% or better, to be of practical use. Even by manually drawing a calibration graph, we found we could achieve almost 1% accuracy, and the algorithm would need to be at least as good as this to avoid introducing systematic errors into the result. 2. The algorithm must be accurate for all elements, bander all practical conditions. Thus we considered both gentle and severe curvatures, whether instrument-related or more fundamental, as part of the same mathematical problem. 3. The algorithm must be accurate for all atomizers and all measurement modes. We commonly measure equilibrium absorbance signals from a flame atomizer or peak signals from a furnace, and in each situation an accurate concentration output is needed. 4. The algorithm must be accurate over a wide dynamic range in concentration. The total dynamic range in atomic absorption is only about 4 orders of magnitude, and to further restrict this range with a limited curve-correction formula would be a severe disadvantage. 5. The algorithm must achieve this accuracy with a limited number of standards. A blank and three standards is a well-established analytical prescription, and it would be a significant practical advantage if this prescription could be followed. It is also desirable to allow less accurate but more convenient calibration with 1 or 2 standards, and more accurate calibration with perhaps 5 standards. For more than 5, the labor in preparation and maintenance of standards becomes too great to be justified for most work. With these constraints in mind, we established the shape of the curve in detail for a number of extreme and intermediate cases, ranging from silver determinations in the flame where the calibration was almost exactly linear up to 2.0 absorbance, to arsenic determinations where (under the extreme conditions applied) the calibration curved towards an asymptote at about 0.6 absorbance so that every concentration above 400 µg/ml produced almost the same absorbance. In this paper we will concentrate on the results obtained for nickel at 232.0 nm. This is an important practical example, and it also represents one of the most stringent tests of the various computation algorithms. The curvature is quite severe, and the severity depends on the instrumental condi- tions so that different degrees of curvature are likely in different laboratories. For nickel, we prepared 21 accurate standard solutions covering the range up to 50 µg/ml. The calibration points fall on curves as shown in Figure 1. Figure 1. At this stage we assumed no knowledge of the causes for curvature; we were concerned only with the shape of the curve. We first considered simple mathematical functions as approximating curves (Figure 2). Figure 2. All of these would be fairly easy to compute, although the quadratic and cubic polynomials expressed with concentration as the variable would require iterative computation to convert a measured absorbance into an unknown concentration after calibration. Results Now, using the nickel results at 0.5 nm bandwidth as a typical example, let us examine the performance of these algorithms. The quadratic in abs, c = P + Qa + Ra 2, is not generally satisfactory (Figure 3). 2

Figure 3. If the concentration range is small, a good fit can be obtained with well-chosen standards, but this will only apply if the operator has detailed knowledge of the behaviour of the curve in advance. For this nickel example we could not obtain a satisfactory fit above 15 µg/ml so that two-thirds of the possible working range must be sacrificed. The quadratic in conc, a = P + QC + Rc 2, is a better fit (Figure 4). Figure 5. For more gentle curves, this approximation is excellent, but for a fairly severe curve such as this, there is a compromise. If the curve fits well at the top of the range there are errors at the bottom, and vice versa. The cubic in conc polynomial, a = P + QC + Rc 2 + Sc 3, can avoid this problem. With the correct choice of standards, a good fit can be achieved throughout the range (Figure 6). Again, however, there are possible turning points within the range if the wrong standards are used, and beyond the last standard the results are doubtful. For example, if the last standard used was 40 µg/ml the error at 45 µg/ml could be as much as 10%. By using more standards it is possible to refine either of these cubic approximations. Least-squares regression, for example, produces a curve such as that shown in Figure 7 (using 10 standards). Figure 4. There are, however, two obvious problems. The working range is again limited, and because the turning point of the parabola is so close there is a risk of misinterpretation. When a measured absorbance can correspond to two quite different computed concentrations, errors are almost certain. A cubic polynomial is better still. The cubic in abs, c = P + Qa + Ra 2 + Sa 3, can certainly be useful for this curve (Figure 5). Figure 6. 3

To improve this, one instrument company has published a modified exponential function based on transmittance rather than on absorbance data. There is a benefit (see Figure 9). Again, however, only two standards are used and the fit is not good over a wide range, at least for our data. Figure 7. The nature of the least-squares approach is to produce the largest benefit with the largest numbers, and here the curve does indeed fit well at higher absorbance. However, a cubic function is inescapably cubic, and as in this example it will always give errors above the last standard. If anything, the errors are worse using the regression because the lower part of the curve has been forced into a particular shape which emphasizes the rate of change beyond the last standard. An exponential function has sometimes been recommended for curve fitting in AA, because conceptually the curve seems to approach an asymptote. For nickel the fit is quite good (Figure 8). Figure 9. A New Method After considering all of these approximations, we concluded that none were wholly satisfactory. All of them are useful in a small working range, but over a wider range all of them have one disadvantage or another, causing inaccuracies. We concluded that the natural calibration graph (absorbance against concentration) could not be approximated well enough without more complex mathematics. Therefore, we searched for some transformation of the data which would produce more easily-handled curves. Graphical trials on several possible transformations revealed that a plot of a/c against a, or c/a against c, produced pseudo calibrations which had very desirable properties. We chose the a/c against a plot as the basis for a new calibration algorithm using the parabolic rational function a/c = P + Qa + Ra 2. For brevity we call this the rational method. Looking at the data for nickel, we can see how this data transformation works (Figure 10). Figure 8. Over a limited range, the exponential is a good approximation, but only two calibration points can be used, and over a wider range the fit between the calibration points suffers. In place of the natural calibration curves, we have new curves with interesting properties. Where the normal calibration is almost straight (at low absorbance), the transformed data follows almost a straight line. The transformed data has no particular physical meaning, but it does allow us to approximate the calibration with very simple mathematical functions. Indeed, a straight line is a good fit to the upper part of these transformed curves (at higher absorbance) and using a parabola the fit is even better. 4

Figure 12. Figure 10. Applying the rational method to these nickel calibrations, and plotting the results in the more familiar absorbance-concentration co-ordinates, the fit is obviously very promising (Figure 11). As we can see, errors do appear above the top standard, but these errors are generally quite small. There is no systematic deviation as there is with the earlier cubic approximations, for example. The calibration range can be extended to the fourth order of magnitude by suitable choice of three standards, as seen above, but for maximum accuracy over the wider range it is better to add a fourth or even a fifth standard (Figure 13). Figure 13. Figure 11. The errors are less than 1% even over this wide range if three calibration points are suitably chosen. Even with badly chosen standards the errors are quite small. For these examples the standards were at 5, 20, 50 µg/ml (good fit) and at 2, 5, 50 µg/ml (worse fit but not a natural choice of calibration points). These curves genuinely possess the characteristics of real calibrations; a benefit which, as we have seen, cannot be claimed for the earlier approximations. Over a limited concentration range (say 3 orders of magnitude), two or three standards are quite sufficient with this algorithm (Figure 12). With five standards, a choice arises: least-squares regression on a single curve, or generation of a family of overlapping curves. Least-squares regression works best when there is a statistically significant number of calibration points, but for four or five standards we prefer to generate a family of overlapping parabolas. This method provides an excellent fit to the actual calibration and allows for the fact that the rational method transformation does not always provide a simple curve. There is a degree of S-shape in the curve at high absorbance which is best approximated by taking a family of parabolas rather than one. This rational method is very successful for a large variety of curves. The most severe curve in our trials was for arsenic under extreme instrument conditions which resulted in the calibration curving almost to an asymptote at about 0.6 absorbance (Figure 14). 5

The same excellent fit is obtained using other atomizers. For peak height or peak area results in the graphite tube atomizer, or with vapor generation methods, the fit is excellent. Even flame emission results can be accommodated, in spite of the fact that self-absorption (the major cause of curvature in flame emission) produces fundamentally different curves which would not be expected to match the same algorithm as the atomic absorption curves. This new algorithm has been chosen as the calibration method for our atomic absorption products. Figure 14. With five standards, even this curve could be accommodated. In practice, of course, it is not feasible to use such a calibration at high concentration because the absorbance difference between 350 and 400 µg/ml is almost zero. Over a more limited range the curve can be accommodated with three standards. Where the curvature is not so severe, three standards are almost always sufficient (Figure 15). We feel that this new rational-method algorithm will provide consistently better results than any previous method. It is very quick in computation, involving no iterations or approximations (unlike exponential methods). It fits exactly at each calibrating point (unlike regressions methods), and for all of the elements in our study the accuracy was better than 1% at all points with any rational choice of standards. It allows the entire working range to be used up to about four orders of magnitude, and it allows for all types of calibration curvature regardless of the cause. This Varian Instruments At Work was originally published in August 1977 as a Lecture Transcript. The rational method algorithm described here has been used in all Varian AA instruments produced since then and the method has consistently proved its accuracy and fidelity. For More Information For more information on our products and services, visit our Web site at www.agilent.com/chem Figure 15. For silver and copper there is little curvature and almost any approximation is good; the rational method is no exception. For iron, which is an example of moderate curvature typical of a large class of elements, the fit with three standards is excellent (the absorbance scale here has been extended to 2.0 absorbance, so that the curvature for iron appears to be exaggerated). www.agilent.com/chem Agilent shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing, performance, or use of this material. Information, descriptions, and specifications in this publication are subject to change without notice. Agilent Technologies, Inc., 1986 Printed in the USA November 1, 2010 AA058