Radiator Lockshield Valves ADN.. AEN..

Similar documents
Radiator Valves. Building Technologies HVAC Products. NF norm, for 2-pipe heating systems

Electromotoric actuators

HERZ STRÖMAX GM/GML/GR STRÖMAX-GM/GML Circuit Control Valve with test points STRÖMAX-GR Circuit Control Valve Data sheet STRÖMAX GM/GML/GR, Issue 0215

Electromotoric actuators

Electromotoric actuator

3-PORT SEAT VALVES PN16 WITH EXTERNALLY THREADED CONNECTIONS STAZ-16, STBZ-16, STCZ-53 DATASHEET

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Lockshield valves Series 195UM - 196UM 1195UM UM

SAX.. ACVATIX Electromotive actuators for valves. with a 20 mm stroke

Rotary actuators for ball valves

OCI Service tool. As of ACS790 V9.00. Service case with software and service interface

2-PORT SEAT VALVES PN16 WITH FLANGED CONNECTIONS STAZ-16, STBZ-16, STCZ-52 DATASHEET

AEW Pulse Adapter. Building Technologies

Electrical Actuators

M3P..G/A, M3P..F/A Modulating control valves (PN16) for chilled and hot water systems

Electrical Actuators

Electromotoric actuators

RMZ790. Operator Unit. Building Technologies. Synco 700

Electromotoric actuators

Electromotive actuators for combi valves

Immersion Temperature Sensors

Fast running actuators for air dampers

Electrical actuators

Rotary version, three-position control

Temperature sensors and accessories for heat and cooling measurement points

Jaga-Deco Pro thermostatic valves

AEW36.2. Pulse Adapter. Building Technologies. Siemeca AMR

Heating Circuit Controller

Wall-mounted Heat Interface Unit HIU Instantaneous domestic hot water production Mechanical control

ERF910. RF Repeater. Synco living

Room unit with PPS2 interface

Pipe fittings and flanges, sockets for bayonet locks

Air damper actuators

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

9283P01. Extension module. Integration of existing PT-I/O modules in Desigo Used with PXC50...D, PXC100...D or PXC200...D

Rotary actuator for ball valves KNX / PL-Link

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

15 and 16 Series BSP and hose fittings

VAV modular controller

Interface converter for VAV compact controllers

Digital input modules

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Room Temperature Controller

VAV compact controller

Room unit with PPS2 interface

Combi-System. Composition pipe Copipe

RF adapter plugs, dimming

Mobile Data Collector

Electromotoric actuators for stroke valves

TXM1.8RB. TX-I/O Blinds module

Balancing valve PN 16 and PN 25 DN

BSP & HOSE Fittings M5, 1/8... 1

USB-KNX Interface OCI702. USB-KNX interface with cables and service bag

Thermal Mass Flowmeter Sensyflow FMT200-D

Heating Circuit Controller

Catalogue 2016 HOSE TECHNOLOGY. Fittings, Valves and Accessories. Schauenburg Hose Technology Group

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

STAF, STAF-SG, STAF-R, STAG

Temperature Measurement SITRANS TS300

EW773 Series Ultrasonic Hydronic Meters FOR HEATING AND COOLING APPLICATIONS

BACnet/IP Web Interface

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Float switch For industrial applications Model RLS-1000

Room controller STRA-17

Extension module for lighting control

Electrical Actuators

Fume Hood Cable Sash Sensor

Tykoflex cold method. A safe, simple and proven cold method TYKOFLEX COLD METHOD

Compression fittings Metric and inch

Belimo ZoneTight TM QCV 2-way characterised control valves and 3-way change-over ball valves. Table of Contents. Notes for project planning

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Connecting cables for valves, plug pattern ZC, metric screw Type codes

4 Control engineering

Power supply module, bus connection module

Valves, controls + systems Combi-System Copipe Composition pipe Cofit Connection system

Network node WTT56.. A6V _en--_c Building Technologies

Super universal modules

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

RXC39.5. Room controller. Building Technologies. Desigo RXC. Communicating room controller for fan-coil applications

Motorised Butterfly Valve DMK Nominal Diameter Rp 3/4 - Rp 2

Electromotoric actuators

Resistance measuring module

SPCH/ Big bottle blowing block

97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7

RA-N Radiator Valves with Integrated Presetting

Gas Pressure Regulator HON

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

B 201 A B C. dynamx variable flow-control valves, series DXMB_C. Dynamic Flow Networking. Description. Content

21023, 21025, 2/2 Direct solenoid actuated poppet valves

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Ball valve C 200 PROP / C 200 DOS

Series 95000, 2/2 Direct solenoid actuated poppet valve

selection of special materials is available to handle almost any fluid.

Instructions for Use. Viega Eco Plus Universal shower WC element. for wall-hung WCs, wall-hung shower WCs, wall-hung WCs with shower WC top

Motorised Butterfly Valve DMK

PureFlow PEX Crimp Fittings Most widely recognized fitting system in North America

Web interface BACnet/IP

Transcription:

07 EN - Straight version ADN.. Angle version AEN.. ACVATIX TM Radiator Lockshield Valves ADN.. AEN.. for -pipe heating systems Valve bodies made of brass, mat nickel-plated DN 0, DN and DN 0 Integrated presetting of k v -values Internally and externally threaded (Rp/R) conforming to ISO 7- Presetting protected by a cap CEN07en 07-0- Building Technologies

Use The radiator lockshield valves are for use in hot water heating plant to: Shut off the flow of water to the radiator when doing maintenance work or when replacing the radiator Throttle the flow of water for hydraulic balancing in the case of thermostatic valves without presetting or when using manual valves Type summary Straight version Angle version DN k v -value [m /h] setting range ADN0 AEN0 0 0. ADN AEN 0. ADN0 AEN0 0 0.0 Ordering Example: Type Order number Description Quantity AEN AEN Lockshield valves Delivery Valves and accessories are packed separately. Rev. no. See overview, page Fehler! Textmarke nicht definiert.. Function / mechanical design The flow rate can be throttled by turning the plug with an mm hexagonal socket wrench. Cap Guiding sleeve Plug 4 Valve body Union nut 6 Nipple Accessories AVN.. Compression fittings Data Sheet N00 /

Engineering notes k v -value The k v -value gives the volumetric water flow 00 across the valve of bar. V. in m /h at a pressure drop k v -values at different positions Type reference k v -value [m /h] with number of revolutions of plug 0.7... 4 k vs ADN0 / AEN0 0.4 0.6 0.9...6.7.. ADN / AEN 0. 0.4 0.6.0..7.9... ADN0 / AEN0 0. 0.4 0.6 0.....4.6..0 The lockshield valves are supplied in their fully open position. Setting procedure: Remove cap (use a spanner SW, if required) Use an mm hexagonal socket wrench. to fully close the plug (clockwise rotation) Set the required k v -value by making the correct number of revolutions according to the above table or the chart given below (counterclockwise rotation) Replace cap /

Setting charts ADN0 AEN0 V 00 [ m /h] 0.0 0. 0. 00 0.0 0. 0 0 0.4 4 [kpa] 0 0 0. 0. [bar] [mws] 0 4 0.0 0.0 0.0 0. 0. 0.0 0 00 00 00 00 000 000 000 000 V 00 [ l/h] 0 0 0 0 T = 0 K ADN AEN 4 6 0 0 Q [ kw] 00 V 00 [ m /h] 0.0 0. 0. 00 0 60 00 T = 0 K.0 0 0. 07D0 [kpa] 0 0 0 0.4 0. 0. [bar] 4 [mws] 0 4 0.0 0.0 0.0 0. 0. 0.0 0 00 00 00 00 000 000 000 000 V 00 [ l/h] 0 0 0 0 T = 0 K 4 6 0 0 60 00 T = 0 K Q [ kw] 00 07D0 4/

ADN0 AEN0 V 00 [ m /h] 0.0 0. 0. 00 0.0 0. 0 0 0.4 4 [kpa] 0 0 0. 0. [bar] [mws] 0 4 0.0 0.0 0.0 0. 0. 0.0 0 00 00 00 00 000 000 000 000 V 00 [ l/h] 0 0 0 0 T = 0 K 4 6 0 0 60 00 T = 0 K Q [ kw] 00 07D0 /

Notes Mounting The lockshield valves are supplied fully open. Orientation Maintenance Repair Disposal Optional The lockshield valves are maintenance-free. The valves cannot be repaired; the complete unit must be replaced. Do not dispose of the device as household waste. Special handling of individual components may be mandated by law or make ecological sense. Observe all local and currently applicable laws and regulations. Warranty Application-related technical data must be adhered to. If not observed, Siemens will not assume any responsibility. Technical data Functional data Pressure class PN 0 Suitable media cold and hot water, water-glycol mixtures; recommendation: water treatment to VDI 0 Environmental compatibility Medium temperature max. 0 C Perm. operating pressure Test pressure Product environmental declaration (contains data on RoHS compliance, materials composition, packaging, environmental benefit, disposal) RoHS conformity declaration,000 kpa (0 bar),600 kpa (6 bar) CEE07*) compliant Materials Valve body brass, mat nickel-plated Dimensions / weight Fitting Cap O-ring Refer to «Dimensions» brass, mat nickel-plated brass, mat nickel-plated NBR Mounting length DIN 4- Thread Rp internally threaded R externally threaded G thread to ISO 7- to ISO 7- to ISO / *) The documents can be downloaded from http://siemens.com/bt/download. 6/

Dimensions ADN.. AEN.. Dimensions [mm] Thread [inch] Weight [kg] Type DN l l l l 4 B C Rp R G ADN0 0 76 / /B / 0 ADN 4 / /B /4 0 ADN0 0 6 9 /4 /4B AEN0 0 7 4 / /B / AEN 0 7 7 6 / /B /4 0.00 AEN0 0 4 6 0 /4 /4B 0.0 Prod. no. DN Compression fittings for copper and soft steel pipes for plastic pipes with aluminum foil ADN0 0 Prod. no. Connection valve side Connection pipe side Prod. no. Connection valve side Connection pipe side [Inch] pipe Ø [mm] [Inch] pipe Ø [mm] ADN AVN- ½ AVN-A6 ½ 6 x ADN0 0 AEN0 0 AEN AVN- ½ AVN-A6 ½ 6 x AEN0 0 7/

Published by: Siemens Switzerland Ltd. Building Technologies Division International Headquarters Gubelstrasse 60 Zug Switzerland Tel. +4 4-74 4 4 www.siemens.com/buildingtechnologies Siemens Switzerland Ltd 004 Delivery and technical specifications subject to change /