M-Bus-Logger Data Logger

Similar documents
UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

Interface Module XC Level Converter / User Manual

Meter Bus. Intelligent Communication

TS2M-Bus Protocol Converter / User Manual

Interface Module XC Modbus Protocol Converter / User Manual

UniMod Intelligent Communication for all Metering Application

Solenvis SL80 Pulse to M-Bus Converters

SSW7. User Manual. Adapter for MPI-Bus. Version:2 / HW: 1 / FW: 3.0 and higher. Order number of manual: VK21/en VK21

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Smart Energy & Power Quality Solutions. ProData datalogger. Datalogger and Gateway

PSI-MODEM-SHDSL/SERIAL

Modular Two-Wire Telecontrol System

A2000 Multifunctional Power Meter

GmbH, Stettiner Str. 38, D Paderborn. M-Bus Modem

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Millenium II +: general characteristics

SSW7-RK512/RS422. Adapter for MPI Bus with RK512 Protocol, RS VK21. User Manual. Version: 1 / HW: 1 / FW: 2.

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

Process displays For current and voltage

Manual Fiber Optic Interfaces

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

M-Bus Central Unit. Use

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Complete Solutions. Installation of Equipment in Switching Cabinets. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

Manual Industry Interfaces

02/11/2015

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Pen Drive USB Datalogger!

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

SINGLE PHASE AMR ELECTRONIC METER MEM Electric meter has the following functions: Technical information

Micro Motion Model 7950 and Model 7951 Signal Converters

Universal communications device Metcom T A..

Weilekes Elektronik GmbH Am Luftschacht Gelsenkirchen Germany Tel: Fax:

UniStream Uni-I/O Modules

THE SOLUTION. MFW product family DATASHEET. MFW - Modular radio telecontrol system. A system from the. INFOwww.ees-online.de

RS 485 Mini Modbus 1AO

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

Data Collecting Device. ProData. Operating Instructions. Dip Switches. Interface. Mode RS485- PT LON. Interface Analogue Input 0-20mA

EXOcompact Third Generation Manual

Converter Box Data Sheet

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

PCAN-Repeater DR CAN Repeater for the Decoupling of Bus Segments. User Manual. Document version ( )

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

02/11/2015

D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

20.4VDC to 28.8VDC with less than 10% ripple. Input impedance 10mSec typical, when used as normal digital inputs

adjustment via factory default or directly on the sensor signal display flashing at threshold undercut or /exceedance

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

Samba PLC+HMI SM35-J-RA22

EElectronic Devices and Systems. EK-87 Electronic Volume Corrector. This product is discontinued!

The new Expert Logger 400: Industry 4.0 ready!

PADPULS2 M-BUS Pulse Input Modules

ioselect Z-NET Z-SG Bridge Input Isolating I/O Module

Binary output and supervision 520CSD01 Data sheet

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

Product Manual for the Mini Industry Meter MIZ Installation I Device description I Operation

Item SM35-J-T20 SM43-J-T20 SM70-J-T20

LON-module for MULTICAL 601

Control IT AC 800C Controller

U1602, U1603 ENERGY CONTROL SYSTEM

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Installation & Operation Guide

ENMAT Premium Data Logger User Manual

USER MANUAL Z-8NTC 8 CHANNELS NTC TEMPERATURE SENSOR CONVERTER WITH USB / RS485 PORT AND MODBUS RTU PROTOCOL

3 Digital, 3 Digital/Analog, 3 PT1000/NI1000 Inputs, 5 Relay, 1 pnp/npn Outputs

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO

SCADAPack 50. Wireless Remote Data Logger

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

ECT Signal Isolator/Converter

SCHMIDT Sensor interface PROFIBUS Instructions for use

The RTU for small utility applications featuring EN/IEC protocol RTU870

THREE PHASE ROUTER ELECTRONIC METER MET410...K Electric meter has the following functions: Technical information

Item SM35-J-TA22 SM43-J-TA22 SM70-J-TA22

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

COUNTIS Ci Notice d utilisation GB Operating instructions Bedienungsanleitung NL Gebruiksaanwijzing

digiclip Data sheet DF31DP Special features B en

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

Fieldbus Independent I/O Modules SSI Transmitter Interface Manual

TM221M16R controller M IO relay

Analog output 520AOD01 Data sheet

LBVR1718. Description. Features channel paperless recorder

RS485 MODBUS Module 8I8RO

User Manual Revision English

MIC-2 Multi-instrument DATA SHEET

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

RS485 MODBUS Module 8I8O

ABB 520BID01 Binary Input datasheet

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

V350-T38 V350J-T38.

Transcription:

Data Logger User Manual Doc.-No.: E102303517074 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com

COPYRIGHT Copyright 2017 BÄR Industrie-Elektronik GmbH. All rights, including those originating from translation, (re)-printing and copying of this document or parts thereof are reserved. No part of this manual may be copied or distributed by electronic, mechanic, photographic or indeed any other means without prior written consent of BÄR Industrie-Elektronik GmbH. All names of products or companies contained in this document may be trademarks or trade names of their respective owners. Note Based on its policies, BÄR Industrie-Elektronik GmbH develops and improves their products on an ongoing basis. In consequence, BÄR Industrie-Elektronik GmbH preserve the right to modify and improve the software and hardware products described in this document. Specifications and other information contained in this document can change without prior notice. This document does not cover all functions in all possible detail or variations that may be encountered during installation, maintenance and usage of the software. Under no circumstances whatsoever will BÄR Industrie-Elektronik GmbH accept any liability for mistakes in this document or for any sub sequential damage arising from installation or usage of the software. BÄR Industrie-Elektronik GmbH preserves the right to modify or withdraw this document at any time without prior announcement. BÄR Industrie-Elektronik GmbH does not accept any responsibility or liability for the installation, usage, maintenance or support of third party products. Printed in Germany 2

Table of Contents 1 General... 4 1.1 M-Bus... 4 1.2 M-Bus Structure... 4 1.3 Communication... 5 2 M-Bus-Logger... 6 2.1 Pulse inputs... 7 2.2 LED-Displays... 8 2.3 Parameterization... 8 2.4 Data Storage... 9 3 Technical Data... 10 3.1 Dimensions... 11 3

1 General 1.1 M-Bus The M-Bus system is a data transmission system for acquiring, evaluating, optimizing and controlling energy and process data. Modular components permit networking of a large number of different energy meters and computer-controlled terminals. The high degree of noise immunity, even in noisy environments, ensures reliably and error-free measured value transmission. Via modem interfaces, it is also possible to cover large distances to connect modular expansions or complex substation systems. The M-Bus system is the system preferred by operators supplying numerous consumers (e.g. industry and technology parks, trade fairs, building managements, etc.). 1.2 M-Bus Structure An M-Bus system consists of user specifically configurable and task specific system components and different repeaters that are grouped together in one or more segments via a simple twisted-pair cable. The structure of an M-Bus segment can be designed as a: Star structure Linear structure Tree structure Figure 1, M-Bus segment 4

Each segment is terminated with a repeater and connects up to 250 terminals (mini repeater: up to 10 / 25 terminals). Repeaters can be cascaded, i.e. segments can brunch to lower level segments. The control centre of an M-Bus system is formed by the M-Bus master. It consists of an M-Bus repeater connected to a normal commercially available PC. Figure 2, M-Bus structure 1.3 Communication Data transfer at the M-Bus is executed serial as Master-Slave operation via M-Bus master or mini master with RS232 interface to PC: Figure 3, Communication A two-wire standard telephone cable (e.g. JYStY N*2*0.8 mm or better) is used as the transmission line for the M-Bus. 5

2 M-Bus-Logger The M-Bus-Logger has a modular design in top-hat rail installation. The following options are available (changeable vie parameterization software): Load profile: 4000 values ( ca. 40 day with 15 min. registration period) Billing data: for 16 resets (e.g.: 16 month-values) For both option the date will be saved by 8 digits with time stamp; Programming and data retrieval by M-Bus (according to DIN EN 1434-3); The following device types are possible: Reed-Inputs: without supply voltage, includes internal Lithium-Battery S0-Inputs, Option 1: with supply voltage 15VDC - 24VDC S0-Inputs, Option 2: with supply voltage 230VAC or 115VDC Reed-Inputs and Option 1: Option 2: Figure 4, Device type This description includes all types of the device. 6

2.1 Pulse inputs The following pulses are available: Potential-free reed pulse, voltage 2,6 to 3,6V (via M-Bus), standard S0 pulse according to DIN 43864 (only with AC or DC supply voltage), optional The register overflow happens from 2 147 483 647 (conforms to 7FFFFFFF hexadecimal) to 0. Reed-Inputs (without supply voltage) S0-Inputs Option 1: 15VDC - 24VDC S0-Inputs Option 2: 230VAC or 115VAC Mix (Option 1) Mix (Option 2) 7

2.2 LED-Displays The functions of the M-Bus-Logger are displayed by two LED s: LED Function Description M-Bus (yellow) Error (red) Dimly lit Blinking light Permanent light Flash M-Bus on-line Data communication via M-Bus Permanent error: Data error in the measurement memory (EEPROM) Action: The M-Bus-Logger must be sent to the manufacturer for service Measuring period: at the begin of new measuring period (e.g. every 15 min.) the Error-LED flashes for one second. 2.3 Parameterization The device can be programmed via the die M-Bus interface (according to DIN EN 1434-3) with the software MBusLogSet. It provides following functions: Set date, clock, baud rate, device address, register value, etc. Read configuration Read data Figure 5, Parameterization program MBusLogSet 8

Factory settings for M-Bus-Logger (if not differently ordered): Baud rate: 2400 Baud (8E1) Primary address: 0 Secondary address: serial number (8 digits) Option (for data storage): load profile, registration period 15 minutes 2.4 Data Storage Bus-Logger consists following components (needed for internal registration memory): Internal Lithium-Battery M-Bus voltage (active ca. 36VDC) Note: For option 1 with supply voltage (15VDC to 24VDC) is for recording of load profile the M-Bus voltage needed! Optionally supply voltage Reed-Inputs with M-Bus active Reed-Inputs without M-Bus S0-Inputs with supply voltage with M-Bus active Pulse logging (Reed): yes Load profile with time stamp: yes S0-Inputs without supply voltage with M-Bus active Pulse logging (Reed): yes Load profile with time stamp: no S0-Inputs with supply voltage without M-Bus Pulse logging (S0): yes Pulse logging (Reed): yes Load profile with time stamp: yes S0-Inputs without supply voltage without M-Bus Pulse logging (S0): no Pulse logging (Reed): yes Load profile with time stamp: yes Pulse logging (S0): yes Pulse logging (Reed): yes Load profile with time stamp: yes Pulse logging (S0): no Pulse logging (Reed): yes Load profile with time stamp: no 9

3 Technical Data Housing: top-hat rail installation Degree of protection: IP20 Dimensions: W = 35+1 mm (Option 1) or 70+2 mm (Option 2) H = 90 mm D = 58 mm Protection class: 2 Auxiliary power (M-Bus): max. 3mA via M-Bus (:= 2 M-Bus standard load) Battery: Type: Lithium 3,6V (necessary for load profile) Lifespan: ca. 8 years without M-Bus connection Supply voltage: optional (possible for S0 pulses only) None: Reed-Inputs only Option 1: 15VDC to 24VDC (S0 and Reed) Option 2: 230VAC (S0 and Reed) or 115VAC Interface: M-Bus passive (according to DIN EN 1434-3) Baud rate: 300, 2400 (default), 9600 or 19200 Baud 8E1 Software interface: According to IEC 60870-5 primary or secondary addresses Pulse inputs: No.: 2 Type: Reed (all versions) or S0 (Option 1 or 2 only) Pulse frequency: max.12hz, pulse length 40ms minimum Option: 150Hz (pulse length 0,05ms / break 5ms) Pulse input reed: Potential-free, min. 1MΩ isolation Capacity: < 2nF (incl. cable) Resistor: open > 1 MΩ close < 2kΩ Voltage: 2,6 to 3,6V Currency: ca. 11μA Pulse input S0 (Option): According to DIN 43864 Adjustment: 1..255 / 1..255 Measuring period : 1min to 24hours Real time clock: max. deviation 30 sec/month at 25 C (10ppm) Data storage: Load profile: max. 4000 values Billing data: max. 16 resets LED: 2 LED s for: Error and M-Bus Extent of delivery: - M-Bus-Logger with 2 Reed-Inputs Optional: - Power supply for AC or DC - 2 pulse inputs for S0 pulses Order-Number: 11913: 2 Reed-Inputs, without supply voltage 12405: 2 S0-Inputs, supply voltage 15VDC to 24VDC 11792: 2 S0-Inputs, supply voltage 115VAC 11821: 2 S0-Inputs, supply voltage 230VAC Accessories: - M-Bus Master / Repeater / Mini Master - Cable - Software MBusLogSet - AMR-Software (e.g. SIGLON) 10

3.1 Dimensions 11

Subject to change without notice!