Wind Plant Systems Grid Integration Plant and Turbine Controls SCADA

Similar documents
Power System Network Simulator (PSNsim)

Utility Interconnection. Highlights of the New Fast Track Process Proposed by FERC and Changes to IEEE 1547

Christian PAYERL, Poznan, 20 th May, 2009 ABB FACTS Grid connection of Wind Farms. ABB Group May 22, 2009 Slide 1

Grid Interconnection of Renewable Generation

ISO New England Data Modeling Requirements

3/2/2010. SCADA Defined. What They re Generally Best At (Although All Systems Vary) Three Levels of SCADA Systems

Small Generator Interconnection System Impact Study Report. Completed For Q0047

The current state of the electrical grid And the technologies that will enable its transformation

FACTS and HVDC for Grid Connection of Large Wind Farms

Interconnection and Transmission

OVERVIEW: KEY APPLICATIONS

Si-TEC Xtend CGC ET DATA SHEET. Digital control range for extraction steam turbines. Key features. Models. Description

Advanced Wind Turbine Concept. Mita-Teknik. Data Sheets. Park Control Mita-Teknik. All rights reserved

INTERCONNECTION FACILITIES STUDY REPORT

ENGINEERING AND SERVICES FIRM THAT SPECIALIZES IN HYDROELECTRIC POWER AND CONTROL SYSTEM DESIGN, OUR TEAM OF PROFESSIONALS HAVE WORKED TOGETHER

PLUS Technology for Large Scale Renewable Energy Integration

Matthew Musto, Senior Project Manager, New York ISO Charles Alonge, Senior Software Developer, New York ISO

Protection, Monitoring, and Control System for Distribution Substations ALARM HISTORY SYSTEM COMM. On-Line Documentation TRANSFORMER 12 MW

SEL Real-Time Automation Controller (RTAC)

Advanced Protection and Control Technologies for T&D Grid Modernization

Si-TEC Xtend CGC DATA SHEET. Digital control range for steam turbine generators. Key features. Models. Description

Real-time visualization for detecting and solving power system challenges

Si-TEC Xtend GSM DATA SHEET. Digital control range for grid parallel/bus tie. Key features. Description

Large Embedded Generators Register of Completed Projects

Karl Iliev, San Diego Gas & Electric Company

Wind Power SCADA. SCADA system for modern wind farm control.

POWER-ONE ITALY, 5 TH JUNE 2018 Cloud, Big Data & Cyber Security. Business, Opportunities and Risks

THE NEXT BIG THING IN DISTRIBUTION AUTOMATION

2009 E09PS E09PS E09PS E09PS E09PS E09PS38 IEEE 2009 E09PS39 E09PS40 E09PS41 E09PS42 E09PS43 IEEE 2008 E09PS44

Power Distribution Automation Solution Smart Grid Data Aggregation. Patrick Pipet IEA/ADEME Workshop XVII may 18th, 2011

Bob Warden. IP Metering and the Smart Grid WAN Revolution October 27, 2008

Hot pluggable communication modules

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 10, 2015 ISSN (online):

Power System Enterprise Solution

WAProtector Power System Wide Area Monitoring Protection and Control

Power System Resilience & Reliability. Robert W. Cummings Senior Director of Engineering and Reliability Initiatives i-pcgrid March 28, 2017

The bridge between green energy and the power grid CM-UFD grid feeding monitoring relays with Modbus RTU

Status and Next Steps NARUC Electricity Committee Hank Courtright, Senior VP July 15, 2014

Features. Application range. Si-TEC Xtend Recip interface. Accumulated data recording of engine running hours, kwatt hours, kvar hours, etc.

TriStar MPPT (150V and 600V) Wind Charging Control Info

Facility Connection Requirements

PG&E Transmission Interconnection Handbook

Interconnection Feasibility Study Report GIP-IR377-FEAS-R1

Multilin P30 Phasor Data Concentrator

Quantum Chargers Enhanced AC Line Transient Immunity

Generator Interconnection Impact Study Report Pamlico County, NC 200 MW Wind Farm Queue #281

Sacramen Sacr t amen o t Municipal Utility Dis t Dis rict t SMUD May Ma 10,

SIGUARD System for Phasor Data Processing

SCADA Upgrades to Otay Water Treatment Plant

Revised Generation Interconnection Impact Study Report. For. Queue Position 31 ( Interconnection Customer )

Rule 21 Working Group 3

Programmable laboratory power supplies direct from the manufacturer

Application Note (Revision NEW) Original Instructions. EGCP-2 Differences

The Automation of Converting SCADA EMS Displays to PI WebParts

CIM, PI AF and SISCO CIM Adapter Create New Application Opportunities for Utilities

Demonstration Test Bed for Advanced Control Systems

Distributor Thoughts on Smart Grid

Generation Interconnection Feasibility Study Report

DISTRIBUTED GENERATION INTERCONNECTION REQUIREMENTS

Reliable Monitoring Data for PV plants

2U/5U. AC + DC Power Solutions. Transient Generation for Disturbance Tests. only. High Performance Programmable AC Power Source

3. SCHEDULED ACTIONS Scheduling Using Different Bases: Time, Temperature, Pricing Signals...32

IDM DATA ACQUISITION SYSTEM

DRAFT Reliability Guideline: Modeling Distributed Energy Resources in Dynamic Load Models

Reliability Models for Electric Power Systems

Substation SCADA Monitoring

Evolution of Control for the Power Grid

XXXXX XXXX Wind Generation Project

C E R T I F I C A T E O F C O M P L I A N C E

Dispatcher Training Simulator (DTS) JOB AIDE

THE INTEGRATED TESTING SOLUTION

Substation automation products. MicroSCADA Pro for substation automation

NERC Event Analysis Update Webinar. Hassan Hamdar Chair, Event Analysis Subcommittee October 20, 2016

The Importance of Coordinated Control Systems in Solar Generation Plants

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

University of Strathclyde

Smart Distribution Technology

NEO 3000 Substation System THE FAMILY OF EQUIPMENT DEDICATED FOR POWER UTILITIES. Energy Sector

Series 2400 Paralleling Switchgear

Welcome and Workshop Opening Ted Reguly, Director Growth and Technology Integration Department SDG&E EPIC Fall Symposium.

ABB ABILITY NETWORK MANAGER X. SCADA for rail Operational confidence.

INTER PLANT STANDARD STEEL INDUSTRY

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

4.1.1 Generator Owner Transmission Owner that owns synchronous condenser(s)

Mains Quality PQ-ANALYZER CLASS A

SCADA Protocols. Overview of DNP3. By Michael LeMay

SIMEAS Q80 quality recorder: Voltage quality starts with measurement.

PGC 4000v2 POWER GENERATION CONTROLLER

Peter Overgaauw Pascal Stijns 27 Oct 2016 EXPERION PKS CONTROLS ELECTRICAL SYSTEMS TOO!

Collector System Design Considerations for Wind Farms. Sean Carr Ernst Camm S&C Electric Co.

Transformer Protection Relay

Table of Contents. Section 10 - Grid Tie

Lessons Learned Implementing an IEC based Microgrid Power- Management System. K.A. GRAY, J.J. MRAZ* POWER Engineers, Inc.

System Acceptance Testing & Performance Evaluation of Battery Energy Storage Systems

Flexible High-Speed Load Shedding Using a Crosspoint Switch

High-Reliability Fault-Clearing System solution. Application Guide. Outdoor Distribution (15.5 kv through 38 kv) S&C ELECTRIC COMPANY

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

CASE STUDY : Transient Stability Simulation Package

Trends for Smart Grid Automation and Industry 4.0 Integration. presented by Detlef Raddatz Managing Director SystemCORP Embedded Technology

Transcription:

GE Energy Wind Plant Systems Grid Integration Plant and Turbine Controls SCADA Mahesh Morjaria Manager, Wind Plant Systems Platform Adopted for Wind Power Management class http://www.icaen.uiowa.edu/ edu/~ie_155/ by Andrew Kusiak Intelligent Systems Laboratory 2139 Seamans Center The University of Iowa Iowa City, Iowa 52242 15227 andrew-kusiak@uiowa.edu Tel: 319-335-5934 Fax: 319-335-5669 http://www.icaen.uiowa.edu/~ankusiak Agenda Grid Friendly Wind Plant Wind Plant Controls SCADA System 1

What makes a Wind Plant Grid Friendly? Does not trip during Faults and other System Disturbances ride through capability Regulates Plant Voltage and Power Limits the Rate of Change of Power from Variations in Wind Speed Ramp Rate Control Reacts to Changes in Grid Frequency Frequency Droop Controls the Insertion and Removal of Large Power Blocks Startup and Shutdown Control Provides Reactive Power When Needed Wind Free Reactive Power Grid Fault Tolerance 120 GE's Standard WindRIDE-THRU Offerings Low Voltage Ride Through > Required by grid codes > Improves gearbox life Zero Voltage Ride Through > Required by FERC after 12/31/07 > New controls for unbalanced faults > GE 1.5 and 2.5 will comply Fault Recovery tage at Point of onnection (Percent) Volt Interco > Voltage recovery better than conventional generator Grid X X Gen Unbalanced line-to-line fault 100 80 60 40 Transmission Bus Voltage (pu) 20 LVRT ZVRT 0-1.0 0.0 1.0 2.0 3.0 4.0 5.0 6.0 200 ms Time (seconds) Total Plant Power (MW) 0.9 1.2 1.0 0.8 0.6 0.4 0.2 0.0 250 200 150 100 50 0 Voltage recovery of the wind farm is better Time (seconds) Synchronous Generator swings dramatically Mahesh Morjaria #4 2

Low Voltage Ride Through Capability Low voltage ride through (LVRT) is a turbine capability when the voltage in the grid drops due to a fault or load change in the grid. The severity of the voltage dip is defined by the voltage level during the dip (may go down to zero) and the duration of the dip. Depending on the application the device may, during and after the dip, be required to: Disconnect temporarily from the grid, but reconnect and continue operation after the dip Stay operational and not disconnect from the grid Stay connected and support the grid with reactive power Mahesh Morjaria #5 Power Droop When circuit activity changes abruptly, it can cause a sudden drop or rise in power supply voltage. This change is known as power droop and is an instance of power supply noise. Power droop can cause an IC to fail. Such failures should be screened during testing Evaluation of the worst-case power drop by accumulating the high- and low-frequency effects. Mahesh Morjaria #6 3

Voltage Regulation Regulates Grid Voltage at Point of Interconnection Minimizes Grid Voltage Fluctuations Even Under Varying Wind Conditions Actual measurements from a 162MW wind plant Average Wind Speed Voltage at POI Wind Plant Voltage Wind Turbine Generator Converter Control kw kvar 34.5k V Transformer Substation Main Transformer WFMS POI 45 mi. 230kV Average Wind Speed Wind Plant Power Output kw kvar Voltage Regulation Like A Conventional Power Plant Mahesh Morjaria #7 Active Power Controls Typical Grid Requirements > Ramp rates > Power curtailment > Power droop w/ frequency 1.200 1.000 0.800 0.600 Curtailment Example 0.400 Available Power 0.200 0.000 Actual Power Shutdown Ramp Test Power Droop Test 2% Frequency Increase Power (kw) Power Ramping Down Turbines Transitioning Offline Power (kw) 50% Power Reduction Frequency (Hz) Mahesh Morjaria #8 4

WindFREE Reactive Power Wind Turbine converter can deliver reactive power (kvar) without wind (kw) Benefits weak grids and systems with high wind penetration Voltage support continues without active power generation even following trips Reactive Power - even without wind Mahesh Morjaria #9 Agenda Grid Friendly Wind Plant Wind Plant Controls SCADA System 5

Wind Plant SCADA System Real-time operational control of each turbine & complete Wind Plant Historical data base with comprehensive reporting system including Production and Wind reports Secure User-Access, intuitive Operation & Maintenance tool Tools to operate, maintain and manage the wind plant Mahesh Morjaria #11 Wind Plant Systems Key Components Turbines VP 2.x VP 2.x Turbine Control Bachmann PLC & PC Controller S/W VisuPro S/W RM&D RCC WindCONTROL TM Plant Level Control Grid Mgmt Plant Optimization Intermittency Mgmt Ethernet Network OPC ODBC WindSCADA Real Time Viewer Reporting System Remote Access Customer System Substation Met Mast Web-based SCADA Replace PC MkVIe Platform Remote User Mahesh Morjaria #12 6

Plant Level SCADA System Mahesh Morjaria #13 Plant Level SCADA System Mahesh Morjaria #14 7

3.X Reporting System Advanced Reports Tabular listing of park efficiency variables with units in column headers Next Gen Reporting Higher level processing actionable information Web based Reporting Scheduled Reports Multiple Language Capable Park Efficiency Report Park Efficiency Report Sample Ver 1.vsd Pareto chart of trip events Provides trip counts, outage duration and lost energy Mahesh Morjaria #15 Web Based Reporting System Available Reports Operational Reports Operational Data Meter Reading Plant Efficiency UPE Due to Curtailment Performance Grid Power Curve Line Plot Power Curve Line Plot Comparison Power Curve Scatter Plot Power Curve Scatter Plot (Min/Max) Wind Speed Distribution Maintenance Reports Historian Data Coverage Event Log Event Pareto Fault Analysis Command Log Parameter Change Inverted Input VP/Bachmann PLC Comm Loss Parameter Values Time period of report Scatter plot of actual power versus reference power Data points for power curve are segmented into bins. The bins are organized in 0.5 m/s increments with the center point in the Bin column. For example, the first bin is 1.75 2.25 m/s. Wind speed (m/s) of data point Power (kw) of data point Site reference power (kw) for that wind turbine at that bin wind speed. Minimum 10-minute averaged power (kw) for the data points at that bin wind speed. Maximum 10-minute averaged power (kw) for the data points at that bin wind speed. Mahesh Morjaria #16 8

Web Based Reporting System Available Reports Operational Reports Operational Data Meter Reading Plant Efficiency UPE Due to Curtailment Performance Grid Power Curve Line Plot Power Curve Line Plot Comparison Power Curve Scatter Plot Power Curve Scatter Plot (Min/Max) Wind Speed Distribution Maintenance Reports Historian Data Coverage Event Log Event Pareto Fault Analysis Command Log Parameter Change Inverted Input VP/Bachmann PLC Comm Loss Parameter Values Time period of report Data points configured in report Line graph of 10-minute averages for configured data point in report, time frame is also configured Ten minute averages for the configured data points in report Mahesh Morjaria #17 Backup Material Mahesh Morjaria #18 9

160 140 120 100 80 60 40 20 0 154 123 27 2 1 1 1 2 3 4 5 6 20 15 10 5 0 1 2 3 First SCADA Users Group Mtg at AWEA Conference Participants 14 users from FP&L, AEP, Brookfield Power, Horizon Energy, enxco, AES Agenda SCADA development plans Test drive of web-based reporting and ESS operational web pages with user surveys Feedback Sessions Customer Feedback: Browser based tools preferred, FPL has nine different SCADA packages across fleet migration to Web-based tools Connectivity to third party systems (OSI-PI, Second Wind, customer systems) a plus relative to other vendors open architecture Increased user configurability & flexibility Reports get customized at each site Excel export capability key Users appreciated opportunity to provide inputs, look forward to next year s event Need upgrade for their existing SCADA s/w Mahesh Morjaria #19 WindSCADA Version 3.0 Released (June 2007) Key Features: Web-based Reporting with improved performance Built-in export capability (Excel, PDF, XML etc) Improved Product Documentation Fixed major software bugs of previous version RTViewer Issues Reporting Services 200 166 157 100 0 1 2 3 9 Alarm Manager Mahesh Morjaria #20 10

Mahesh Morjaria #21 WindCONTROL Hardware Overview Substation Mounted Cabinet PT&CT Interface to Substation SCADA HMI Operates on Wind Plant LAN Plant Level Controller Orchestrates Operation of Individual Turbines Mahesh Morjaria #22 11