November 3rd, 2016 Studio 5000 V29 & Controller Update

Similar documents
Safety over EtherNet/IP with Compact GuardLogix, Kinetix and PowerFlex drives

What s new in Logix? Studio 5000 V28 and High Performance Hardware PUBLIC. Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

L18 - Studio 5000 and Logix Basics Lab

CompactLogix 5370 L2 Programmable Automation Controllers

Kendall Connection Live

CompactLogix 5370 L3 Programmable Automation Controllers. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

CompactLogix 5370 L3 Controllers

CompactLogix Selection Guide

Studio 5000 v31 Release Summary

1769 Expansion Cables

Compact GuardLogix. GSR Relay CR30. GuardLogix. Making Safety Simple PUBLIC. Copyright 2017 Rockwell Automation, Inc. All Rights Reserved.

ControlLogix System. Selection Guide. Catalog Numbers 1756 Series

ControlNet Communication Options for 1768 CompactLogix Controllers

Studio 5000 v31 Release Summary

Introduction to Safety PLCs GuardLogix & CIP Safety

T62 - Next Generation of Compact AC Drives

Logix Controllers Comparison

CompactLogix 5370 L2 Programmable Automation Controllers

T22 What s New in CompactLogix Controllers

Studio 5000 Architect Getting Results Guide

ControlLogix/Studio 5000 Logix Designer Course Code Course Title Duration CCP143 Studio 5000 Logix Designer Level 3: Project Development 4.

ControlLogix 5580 and GuardLogix 5580 Controllers

T28 Introduction to GuardLogix Integrated Safety Systems

T39 - What s New in Logix

T40 - What's New in Connected Components Workbench Software?

Leveraging Automatic Device Configuration. K endall C onnection L ive!

Logix5000 Controllers Nonvolatile Memory Card

T02 - What s New in Logix Hardware. Copyright 2014 Rockwell Automation, Inc. All Rights Reserved.

T61 Leveraging Integrated Architecture Using Kinetix and PowerFlex Drives

CompactLogix Communication Options

Integrated Architecture Midrange System

Connected Components Workbench Software Release 10.00

PanelView 5000 Portfolio of Graphic Terminals

GuardLogix 5570 Controller Systems

W05 High Availability for Today s Process Market

Logix Designer V16 V30 PUBLIC. Copyright 2016 Rockwell Automation, Inc. All Rights Reserved.

Integrated Motion on EtherNet/IP: 8 Axis Basic Linear/Ring. Note: Performance is what we tested, not the max capacity PV+ HMI.

EtherNet/IP Network Configuration

PanelView 5000 Portfolio of Graphic Terminals

User Manual. PowerFlex 25-COMM-E2P Dual-Port EtherNet/IP Adapter

EtherNet/IP Communication Modules in Logix5000 Control Systems

Logix Controllers Comparison

EtherNet/IP Network Configuration

EtherNet/IP Network Configuration

L25 - Studio 5000 Logix Designer : Basics Lab. For Classroom Use Only!

Integrated Safety & PowerFlex DriveGuard

L01 - Basic Stratix Switch and EtherNet/IP Features in Converged Plantwide Ethernet (CPwE) Architectures

L14 - Experience Connected Components Workbench Software to Develop Your Basic Standalone Machine Application

Studio 5000 Automation Engineering & Design Environment Enhance Productivity through Simplified System Development

T31 - What s New in Studio 5000

Scalable Motion Solutions

GuardLogix Controller Systems

GuardLogix Controller Systems

IntegratedArchitecture

ControlLogix Communication Modules

ControlLogix Controllers, Revision 18

ControlLogix Redundancy

Allen-Bradley Communications Modules Implementing network-based access control for users, devices and networks

L05 - PowerFlex Drives Configuration & Programming

Reference Manual. Replacement Guidelines: ControlLogix 5560/5570 to ControlLogix 5580

Integrated Architecture. Putting the Pieces Together

ControlLogix Redundancy

Applying EtherNet/IP in Real-time Manufacturing. Copyright 2012 Rockwell Automation, Inc. All rights reserved.

DESIGN These Tools & Documents Help You Design Your EtherNet/IP System

CompactLogix System. Selection Guide

Logix5000 Controllers Produced and Consumed Tags

GuardLogix Controller to Kinetix 6000 Drive with Safe-Off using EtherNet/IP CompactBlock Guard I/O Module

AKD Using AKD EtherNet/IP with RSLogix Manual

L17 - Studio 5000 View Designer featured on the PanelView 5000

Agenda. Session Agenda. Introduction to GuardLogix Approx 15min. Hands-on lab Approx 1.5 hrs

Guardmaster Safety Relays. Innovative technology in a broad portfolio of safety control solutions

Optimize Productivity with RSLogix 5000 Design and Configuration Software

Distributed Control System Training Curriculum. PlantPAx. Distributed Control System. Improve Performance with a Complete Workforce Training Solution

Logix5000 Controllers Add-On Instructions

Scalability-The Best Approach to Change

WORKBENCH SERIES. FREE Technical Updates & Training. technical training 2016 TOPICS: Multiple dates, times, and locations!

ControlLogix Controllers, Revision 18

Optional Device Level Ring (DLR) Single fault tolerant network provides resiliency Device level ring requires no additional hardware to implement

Logix5000 Controllers I/O and Tag Data

Micro800 Programmable Logic Controller (PLC) Family

Logix5000 Controllers Major, Minor, and I/O Faults

L18 - Studio 5000 and Logix Advanced Lab New and existing features

L01 - Effective Design Methods for Integrating Safety Using Logix Controllers. For Classroom Use Only!

SINAMICS Drives Connectivity with EtherNet/IP TM. Networks. Manufacturing in America 02/22-23/2017

Logix5000 Controllers Design Considerations

T08: What s New in Motion and Time-based

Agenda. 1. Controllers, I/O, HMI terminals, Network switches. 2. Motion Control Current Product Technology, Next Generation Control

Actuator Subsystems Stop Cat. 0 or 1 via an Integrated Safety Controller and PowerFlex 527 Drive with Hardwired Safe Torque Off Safety Function

CT233 - Intelligent Motor Control The Connected Enterprise

Allen-Bradley Replacements

T29 - New PanelView TM 800 HMI Family

Troubleshooting Ethernet Network Issues When Using Integrated Motion Kinetix and Powerflex Technical Support

T02 - Increasing Software Development Efficiency Using the Integrated Architecture Tools

User Manual. PowerFlex ENETR Dual-port EtherNet/IP Option Module Firmware Revision Number 1.xxx

Safety Update 2017 PUBLIC. Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

Logix5000 Controllers Produced and Consumed Tags

ControlLogix Integrated Motion

OMRON Rockwell CompactLogix or ControlLogix

L20 - Integrated Motion on Ethernet/IP: Advanced Lab. For Classroom Use Only!

ControlLogix EtherNet/IP Bridge Module

Transcription:

November 3rd, 2016 Studio 5000 V29 & Controller Update A M E M B E R O F T H E K E N D A L L G R O U P

Logix Designer v29 What s New in This Release PUBLIC

5370 Safety Controller - Compact GuardLogix New Compact GuardLogix safety controller featuring a 1oo2 safety architecture for SIL 3, PL(e), Category 4 safety applications AFC DEC 2015 Same functionality as equivalent standard catalog numbers Will add 50% extra memory for safety applications Three Catalog Numbers Planned: L30ERMS (+0.50MB Safety Memory, 4 axes of motion) L33ERMS (+1.0 MB Safety Memory, 8 axes of motion) L36ERMS (+1.5 MB Safety Memory, 16 axes of motion) Embedded ENet DLR for CIP Safety communications CIP Motion supported in all catalogs Supported firmware and Studio5000 - V28

ControlLogix 5580 ( L8 ) 1-GB embedded EtherNet/IP port enables highperformance I/O and motion control Multi-Core Processor Integrated Motion on EtherNet/IP for motion applications up to 256 axes supporting 32 axis per ms Onboard display allows for enhanced diagnostics and troubleshooting Reset button feature provides the ability to return the controller to the out-of-the-box state Digitally-signed controller firmware provides an added layer of security Controller-based change detection and logging enable added security Embedded storage module removes the need for a battery

High Performance Architecture Release Focus: Enabling the entire family of the Logix 5580 and 5380 controllers CompactLogix 5380 ControlLogix 5580 Scalable, High Performance Architecture

Studio 5000 Logix Designer v29 Release Summary Hardware Support: Support for the entire ControlLogix 5580 and CompactLogix 5380 family: ControlLogix 5580 (1756-L81E, 1756-1L82E, 1756- L84E) CompactLogix 5380 (5069-L306ER(M), 5069-L310ER(M), 5069-L320ER(M), 5069-L330ER(M), 5069-L340ER(M)) CompactLogix (Device Level Ring and Dual IP) Software Features: ControlLogix 5580 & CompactLogix 5380 - Instruction based alarms ControlLogix 5580 & CompactLogix 5380 - PanelView 5000 support ControlLogix 5580 & CompactLogix 5380 - String Assignment Support ControlLogix 5580 & CompactLogix 5380 - Message to SELF Generic Ethernet Safety and Standard Profile Guardmaster 440C-CR30 Profile Enhancement Compare & Merge Enhancements

New Hardware Support ControlLogix 5580 and CompactLogix 5380 Focused Updates

High Performance Logix Controllers Right size your controller based on your application needs Catalog Number Memory Nodes Integrated Motion on EtherNet/IP Local I/O 5069-L306ER(M) 600 KB 16 2 8 5069-L310ER(M) 1 MB 24 4 8 5069-L320ER(M) 2 MB 40 8 16 5069-L330ER(M) 3 MB 50 16 31 5069-L340ER(M) 4 MB 55 20 31 Catalog Number Memory Nodes 1756-L81E 3 MB 60 Total Axes of Motion Local I/O 1756-L82E 5 MB 80 256 16 1756-L83E 10 MB 100 (subject to 16 1756-L84E 20 MB 150 node limit) 16 1756-L85E 40 MB 300 16 16

ControlLogix 5580 System Scaling Simplified method for counting controller resources The ControlLogix 5580 is now scaled on EtherNet/IP nodes Maximum controller nodes include those connected to the front port as well as backplane communication modules Any device added directly to the Ethernet I/O configuration are counted toward the node limits Remote communication adapters Devices with an embedded EtherNet/IP port (e.g. I/O modules, drives and linking devices EtherNet/IP devices connected to an in-chassis communication module Remote controllers HMIs included in the I/O tree (e.g. PanelView Plus terminals) Linking devices (e.g. 1788-EN2DNR) What is not a node? Computer Communication modules in the local chassis HMIs that are not added to the I/O configuration tree MSG instructions

Controller Node Support View your usage and capacity anytime, right from the new Capacity Tab Capacity Tab Renamed the Memory Tab to be Capacity Controller Capacity Safety Capacity Ethernet Nodes Ethernet Node Counter Clear Indication of Node Capacity Available for ControlLogix 5580 and CompactLogix 5380 and 5370 series controllers

CompactLogix 5380 Machine Architecture Providing flexibility on interfacing to plant networks with or without a switch Device Level Ring: Logical separation of control network Plant Network Dual IP: Physical separation of control network Plant Network CompactLogix 5380 Controller CompactLogix 5380 Controller 100MB 50 Device DLR Ring Stratix 5700 Configurable 100MB 50 Device DLR Ring 1783-ETAP PanelView Plus Kinetix Drives 1734 Point I/O PowerFlex Drives PanelView Plus Kinetix Drives 1734 Point I/O PowerFlex Drives

CompactLogix 5380 (DLR and Dual IP) Simple configuration now available in the Controller Properties dialog Configure the IP Mode (Dual-IP or Linear / DLR mode) in the 5380 Controller Properties dialog

Logix 5580 & 5380 - Instruction based alarms Choose Instruction Based or Tag Based Alarming based on your application Instruction Based Alarms ALMA & ALMD Instruction Support in the ControlLogix 5580 and CompactLogix 5380 Controllers June 13, 2011

Logix 5580 & 5380 - PanelView 5000 support Simple configuration, improved performance, and greater flexibility New Logix and View Communications method New instruction in Logix that HMI will interact with High speed deterministic communications similar to I/O Benefits Reduced lag and improved accuracy for manual jog operations from traditional HMI More flexible than physical buttons with comparable performance Eliminates need for custom logic to verify active communications Jog Motor A-B Logix detects comms failure and automatically resets the button request June 13, 2011

Productivity and Security Improvements ControlLogix 5580 and CompactLogix 5380 Focused Updates

Logix 5580 & 5380 - String Assignment Support Increased programming productivity through better string management Structured Text Editor Support String to String Direct Assignment MyString:= StringTag; Literal to String Assignment MyString:= A String Literal ; Ladder Editor Support Literal to String Tag MOV String Tag to String Tag MOV MOV Move Source MyString UpperRoll Dest StringTag UpperRoll MOV Move Source A String Literal Dest MyString A String Literal

Logix 5580 & 5380 Controller MSG to SELF User configurable functionality for an additional layer of security Programmatic ability enable/disable via Message to SELF Configurable Masking of Scrolled Fields 4-Char LCD Knowledgebase article KB869648 Embedded Web Page Disable/Enable Knowledgebase article KB869649, KB869651 Embedded Ethernet port Disable/Enable Knowledgebase article KB869650, KB869652

Logix 5580 & 5380 4-Char LCD User configurable Masking for an additional layer of security Normal Scrolling Messages on the LCD Display: 1.) Controller Name - ( ) 2.) Link Status - ( ) 3.) Port Status - ( ) Configurable Masking of Scrolled Fields with a MSG to SELF Default (All shown) Controller Name and Link Status (only) Port & IP Address (only) Completely OFF Knowledgebase article KB869648

Logix 5580 & 5380 Embedded Web Page User configurable Disable/Enable for an additional layer of security Configurable Disable/Enable of Controller Embedded Web Page Knowledge Base article KB869649, KB869651

Logix 5580 & 5380 Embedded Ethernet Port User configurable Enable/Disable for an additional layer of security Configurable Disable/Enable of Controller Ethernet Port Knowledgebase article KB869650, KB869652

Compare & Merge Enhancements Increased granularity to compare individual parts of individual projects Support any L5X file to perform a compare AOI-to-AOI UDT-to-UDT Program-to-Program Routine-to-Routine One-to-One also One-to-Many Compare AOIs that are signed

Device Profiles New and Improved

Device Profile Enhancements Generic Ethernet Safety and Standard Profile Simplifies Configuration Supports the following connection types: Standard, Standard with Status Safety Safety and Standard, Safety and Standard with Status Simplifies integration and improves user experience One profile versus two One IP address versus two Simplified hardware implementation Common user experience Configurable connection types Single IP address

Guardmaster 440C-CR30 Safety Relay New profile provides a simplified and integrated design experience Available with Add-on Profile v2.01 Fully functional Logic editor for the Guardmaster 440C-CR30 safety relay Benefits: Single software/project for configuring and monitoring Logix 5000 controller and Guardmaster 440C-CR30 safety relays

Thank you! PUBLIC www.rockwellautomation.com