AGT/SUPER SS ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

Similar documents
ELECTRONIC SINGLE/DUAL DISPLAY

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

IDS-801 Series Compact Bench Counting Scale. User Manual

User Manual MODEL DIGI SERI DS

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

CONTENTS. PRECAUTIONS Introduction Installation... 7

EC100. Counting Scale. Operations Manual (V1611)

OHAUS Asia-Pacific Dealer Meeting March 23-25, 2010 Hua Hin, Thailand Compact & Counting Scales

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

KW serial. User s guide. Bench Scales UGKW-E0302

1. Introduction Specifications Operation Guide Trouble-shooting Note... 13

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

MWP SERIES. High Precision

!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

EB300 Weighing Scale Operation Manual

EHC-WF. User/Technical Manual. Contents subject to change without notice

Counting Scales. HC-i Series

S2 USER MANUAL. AL Manual 110ES WL S2 En 103

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Defender Multifunctional Bench Scale for Standard Industrial Applications. Washdown Bench Scales. Standard Features:

NEW. Touchscreen 8000 Series stainless steel indicator with customizable applications

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

Page 1 Instructions Manual for DCS-1T (C191) 21/06/201 INSTRUCTION MANUAL. DCS-1T Digital Crane Scale 1000kg / 2204LB Capacity C191

Compact Bench Scales NEW. Ranger Simplifying even the most complex industrial applications

Navigator. The Only Scale in its Class with Touchless Sensors That Free Up Your Hands! Portable Scales. Standard Features Include:

The Only Scale in its Class with Touchless Sensors That Free Up Your Hands!

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Scout STX Series USB

Adam Equipment LBK SERIES. (P.N. 9596, Revision D, July 2014)

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v )

SAC / SHC / SHC-CH SERIES

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

NB/NHB Precision Balance

G2 Series Multi-Function Weighing Scales

CAPITAL SCALE CC TEL: (012) FAX: CELL: ADVANCED MASS MEASUREMENT

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0]

Valor TM 3000 Xtreme

PLATINUM PRO6000 PROFESSIONAL SERIES DIGITAL COUNTERTOP / PORTABLE BALANCE

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity

Nimbus Analytical Balances

Navigator. The Only Scale in its Class with Touchless Sensors That Free Up Your Hands! Portable Balances. Standard Features Include:

Ranger Simplifying Even the Most Complex Industrial Applications. Compact Bench Scales. Standard Features Include:

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1

AJ Series. Intelligent-Lab NTEP Centigram Balance. Made in Japan


For the Lab and in the Field

Industrial Scales and Balances

Trade Approved Version NMI: S520

MI101 / MI102 / MI102S INDICATOR

KPZ 71-* / Mobil scale

User Manual ELECTRONIC SCALE

Oxford E Series. Instruction Manual

FG-3000R Digital Force Gauge Operation Manual

Visit for discount prices on Acculab Scales SVI SERIES PROFESSIONAL PRECISION INDUSTRIAL SCALE SVI-10A SVI-20B SVI-50C SVI-100E SVI-200F

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

FG-3000 Digital Force Gauge Operation Manual

MC Piece Counting Scale

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

CONTENTS. PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS I. Programming Mode II. Sales Mode...

Division Services. Model: DPAS-300. Division Portable Bulk Load Accumulator Scale INDUSTRIAL PH (901) FAX (901)

Adam Equipment. Euro January 2003

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

Navigator Series. The Only Scale in its Class with Touchless Sensors That Free Up Your Hands! Portable Scales. Standard Features Include:

B e n c h S c a l e KPZ 2E-06-N Stainless Steel DIN

KERN Veterinary scales

This document courtesy of:

When using the scale, the following safety precautions should always be followed:

TWP series. Weighing Indicator Service Manual

BW/BWS Weighing Indicator

COIN COUNTING SCALE TC-290 SERIES. Count Any Coin, Any Quantity, Anywhere, In Three Seconds Accurately!

Operation and Service Manual. METTLER TOLEDO XRM Price Computing Scale.

AELP PALLET BEAMS SCALES

TWP-W. Weighing Indicator Service Manual

! User Manual Rev. 1

Multi-Function Smart Indicator User Manual

Digital Bench Scale. Revision 8.93 August 12, 1993

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

-Direct.com FG-3000 Digital Force Gauge Operation Manual

Eclipse Analytical Balances

3000 SERIES LOW PROFILE FLOOR SCALE.

Laboratory Balances. Standard. Option (addit. price) KERN Your DKD Calibration Partner. Your specialist dealer

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

The Economical Choice of Balance for Routine Weighing Applications

ISH-DSA DIGITAL SHORE DUROMETER OPERATION MANUAL

NAVIGATOR. Digital Weight Indicator. Completely Menu-Driven Set-up Navigation. Bulletin No. 330D. Cardinal Scale Model 225 Weight Indicator

GPS mini Watch User Manual Introduction. Getting Started. Caution: Step 1) Know your Watch:

PS-IN202 Weighing Indicator User Manual

R310 & N310 R320 & N320 Digital Indicator

INVITATION TO BID. (This is not an order.)

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

uline.com OVERVIEW OF CONTROLS. k g. Tare Menu. Exit. Print. Units PRINT

Transcription:

AGT/SUPER SS ELECTRONIC SINGLE/DUAL DISPLAY WEIGHING/COUNTING SCALE USER MANUAL

Thank you for choosing our AGT-SUPER SS single/double side display electronic waterproof weighing/counting scale. The new SU model is made of plastic and the 3S is made from stainless steel. The scale is manufactured with advanced computer-controlled techniques. It exhibits hi accuracy weighing performance, whilst being convenient for carrying but also being cheap in price. It is sturdy and durable, and widely used in not only retail stores and weighing of ration packing of commodities, but also in high humidity surroundings because of its waterproof function. Ⅰ. MAIN TECHNICAL INDEX 1. Basic Data ITEM TYPE Max. Capacity Min. Capacity Division size (Option 0) Division size (Option 1) Division size (Option 2) Max. Tare Accuracy AGT-S-030 3kg AGT-S-075 7.5kg AGT-S-150 15kg 1.5/3kg 3/7.5kg 7.5/15kg 20e 1/2g 2/5g 5/10g 0.5/1g 1/2g 2/5g 0.2/0.5g 0.5/1g 1/2g 100% Max. Cap. III Pan Size 3S/NEW SU 19 23 cm 2. Working Temperature : -5 to +35 3. Storage Temperature: -25 to +50 4. Power: 6V4Ah rechargeable battery. 5. Net Weight: 3.6kg/pc 6. Dimension: 4pcs/ctn, 58x35x30cm

Ⅱ. KEYBOARD AND CHARACTER PROMPT 1. Keyboard ON/ ZERO Turns the scale on and zero. TARE Tare key. OFF Power off. SET Set up / Configuration key. Set parameter and input configuration. 2. SIGNS MEANING SP x.xx Means the version ------ Out of ballance -L- Low battery - charge immediately. FULL Charging complete. nnnnnn cell. Overload zero of load cell. Please re-adjust or change load

III. OPERATION GUIDE 1. Preparation Level the scale and make sure the pan is horizontal by adjusting the base feet, and using the built-in spirit level for accuracy. 2. Turn on Press the [ON/ZERO] key. The buzzer will sound and the display will show the battery voltage level and 888888, followed by the machine number. The machine will then show 0 and the scale is ready to use. 2.1 Turn off Turn the machine off by holding down the [OFF] key. 2.2 Auto-off (Optional) After 10 minutes of inactivity, the machine will automatically turn itself off. 2.3 Low voltage auto-off When the battery voltage falls below 5.6V, the machine will power-off. 3. Zero When the weight displayed is lower than 4% of maximum capacity, the [ON/ZERO] key, will, when pressed, zero the display. 4. Weighing Put weight on pan. 5. Tare weighing Place container or item on scale and press the [TARE] key. The display will then tare off and will show 0, and the tare LED light will be on. To clear the tare, press the [TARE] key, and the LED light will turn off. Place the objects to be weighed into the container the scale will show the net weight. * Cannot tare until machine is stable. * Can do multiple tares upto Max capacity. 6. Save power function After 40 seconds of inactivity, the machine will switch to auto power save and the display will show 0. Put a weight on the scale to start weighing again. 7. Battery indication Battery lamp: High means voltage higher than 6.3V, Mid means voltage between 6V and 6.3V, Low means voltage lower than 6V.

8. Charge The power is supplied by an internal rechargeable lead acid battery (6V/4Ah). When the display shows -batlo-, please connect the machine to a mains supply and charge immediately. The time of full charging is 12 hours. 9. Set parameters Press [SET + TARE] key for 3 seconds. The display will now enter into the parameter menu. Press [TARE] key to choose and [ON/ZERO] to confirm and move to next item. PRE-Dispaly precision: 0 is default option, 1 is double precision and 2 is super prcision. UNT-weighing unit: 0 means g, 1 means kg, 2 means lbs. BRT-display brightness 1-3 (bright dim) ZER-zero tracking 0~4 (0-4 divisions) dls-reverse display (lcd backlight) 0 means front display only 1 means both displays active. Fit-stability 0~3 (0 fast 3 slowest 1 default) SAV power saving function 1 is on 0 is off Out Audible alarm 0 is alarm at target weight and 1 is alarm greater Or lower than target weight. SPd Display update speed 0 is slow 1 is fast.

Weighing Alarm And Counting 1. Set Weighing Alarm With display showing 0 at the same time press [SET] and [REZERO] display shows rang. 2. Press [ON/ZERO] to confirm, the under LED is lit, to set lower limit press [SET] key to change digit and [TARE] key to change value press [ON/ZERO] key to confirm lower limit. Over LED is lit set upper limit using [SET] and [TARE] key, Press [ON/ZERO] key to confirm. 3.After setting machine will turn off and then auto turn back on, Under LED will remain lit until target weight is reached. Accept LED will be lit and buzzer will sound. Above target weight Over LED will be lit. 4. To remove target weight with the machine at 0 at the same time press the [SET] and [ON/ZERO] key display will show rang press [ON/ZERO] key 3 times machine will turn off and auto switch on. Set Counting 1. Place the number of items on the pan then at the same time press [SET] and the [ON/ZERO] key display shows PCS, press [ON/ZERO] key to confirm display shows 00000 press [SET] key to change digit and [TARE] key to change the value, press [ON/ZERO] key to confirm, remove items from the pan the machine will switch of and auto switch on, place items on pan to resume count. 2. to clear count at the same time press [SET] and [TARE] key, press [ON/ZERO] key 9 times ( machine scrolls through parameter settings) machine then switches off then auto switches on.

SCALE MAINTENANCE 1. Take care not to overload the scale. Do not place heavy things on the scale violently. The damage for overloading is not within the range of the guarantee. 2. Do not use sharp objects to operate the keypad. If the rubber is damaged it will influence the performance of the waterproof seal. 3. Keep the scale clean in order to maintain performance. 4. There is a lead seal on the bottom of the scale. Users are not allowed to remove the seal. If the seal is damaged the guarantee is void. 5. a. You must charge the battery at least once every 3 months during periods of scale inactivity. b. Please take care to correctly connect the battery terminals (ie, black to black, red to red). c. If the battery life seems short, even after frequent charging, please replace with a new battery.