IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

Similar documents
Monitoring system CMC III

Technical System Catalogue CMC III Monitoring System

Power Distribution Unit

Modular PDU Smart metering for your IT

Security 5.6. Monitoring system CMC-TC. Security individual and flexible. Security. communication between the Master and Processing Unit II.

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Smart Monitoring System compact, secure, efficient

The new TS IT rack Rittal IT security Rittal IT power supply Rittal IT monitoring Rittal IT climate control Rittal references

Liquid Cooling Package LCP Cooling Systems

Data Centre In A Box

IT power distribution Power distribution units (PDU) Basic. Versions available:

VizioGuard Tiny. Datasheet

Rittal Cooling Solutions A. Tropp

ROOM GUARD VT335. Environmental Infrastructure monitoring

Blue e+ chillers with the principle

Product Catalogue 2015 Power Distribution Monitoring & Remote I/O Radio Time Systems Isolators

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

ROOM GUARD VT335. Environmental Infrastructure monitoring

Rittal KVM technology

VT805 / Monitoring system

CMC III Processing Unit / CMC III Processing Unit Compact

MCX08M2 Programmable controller

Liquid Cooling Package LCP Cooling Systems

PDU metered/switched/ managed international UK

AC5160 SiPass integrated controller kit

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

RTT I/O Unit DK Assembly, Installation and Operation

TopConsole system TP. Combination options 1-part 2-part 3-part. System accessories Page 537 Monitors, keyboards From page 796 Climate control Page 389

Specification Sheet: HT SERIES

CMC-TC Basic CMC DK

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

Room Temperature Controllers

VT608 / Switched PDU with 8 outlets

IT solutions. News 2003 Additions to the IT Catalogue

PLC PFC200 Controller PFC200 CS 2ETH RS

CMC-TC Master II DK

RiMatrix S Make easy.

Monitoring system LN-VT325. Environmental Infrastructure monitoring

JUMO mtron T Measuring, Control, and Automation System

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

DK-PS Rack. New generation DK-PS Rack for room climate control

SmartAisle. SmartAisleTM. Energy-efficient use of existing cooling power in data centers to

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

RiLine Compact The smart power distribution system

Room Temperature Controller

Room Temperature Controller

LANTIME M3000: Time and Frequency Synchronization Platform

LCP Hybrid Efficient performance with heat pipe technology

PDU Solutions. PDU Solutions

VIDI System Controller

CMC III Universal Sensor

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

INSTALLATION MANUAL Z-UMTS

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

UCU Room Display. Operation Modes. Features. Applications DATASHEET

PI Server - 19 enclosures

Description Front View of SSC-0025 Rear View of SSC-0025

Specifications MLC Plus 50/100/200 Series

JUMO Quantum PID100/PID200/PID300

PT-7728 Series. IEC G-port Gigabit modular managed Ethernet switch. Introduction PT-7728

KNX is a European Standard Protocol used for household and industrial Buliding Management System (BMS).

Cabinet Interface Device

ImproX IXP20 Controller INSTALLATION MANUAL

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Network Components. Network Components 8

MCX06C Programmable controller

LED Controls. Lighting Controls. LED Controls

TM241CEC24R controller M IO relay Ethernet CAN master

TG Technical specifications

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Poseidon 4002 MANUAL

LightRules Network Infrastructure

MGate 5102-PBM-PN Series

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

RACK-220 CHASSIS USER S MANUAL

IEI emerge MicroNode Install and Setup Guide. Contents

ECL Comfort V a.c. and 24 V a.c.

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

Three Phase Systems-International PC302-I/MTD

EDR-G902/G903 Quick Installation Guide

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

H.264 Internet Video Server

Semi Flush-mount Room Temperature Controllers with LCD

EXOcompact. Freely programmable controller

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

Power Monitoring in the Data Centre

Communicative heating controller, Ethernet

Features and Benefits. Certifications

TM221ME32TK controller M IO transistor PNP Ethernet

iloq S10 Online Configuration Guide

Features and Benefits. Certifications

FEATURES AND BENEFITS. Installation and operation. Controller

AC5160 Controller. Fire & Security Products. SiPass integrated

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

USER MANUAL. SL-10 Master Room Controller MODEL: P/N: Rev 4

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Junos WebApp Secure 5.0 Hardware Guide

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

ZLJ\YP[`7YVIL, :[HUKHYK

Transcription:

IT monitoring Monitoring system system representation...446 system overview...448 Processing Unit/Compact...450 sensors/accessories control units/ sensors...45 Interface for CMC II sensors...45 Access System...452 Interface for PSM, PCU...452 PSM and slave PDU for direct connection...45 accessories Power supply unit...457 Programming cable...457 CAN bus connection cable...457 Connection cable/extension...457 Extension cable RJ 2...458 Mounting unit, U...458 Mounting unit...458 Door control system Door control system...459 Door control module...460 Door kit...460 Door comfort handle...460 Door switch...460 Monitor/keyboard unit Monitor/keyboard unit, U...46 KVM switch...46 Dynamic Rack Control RFID aerial...462 RFID tags...462 RFID controller...462 CAN bus DRC...462 Management software RiZone...46 Server shutdown software...46 Your benefits A better overview of your IT infrastructure Enhanced security Automated processes Exceptional cost efficiency High energy savings Simple project management Fast installation Flexible, individual solutions with standard products from Rittal High standard of quality with coordinated standard products Sample applications, see page 449 Liquid Cooling Package LCP, see page 428 Monitor/keyboard unit, see page 46 Electric comfort handle TS 8, see page 564 Rittal Catalogue 4/IT infrastructure 445

Monitoring system Computer Multi Control (CMC) is an alarm system for network and server enclosures, cases, containers and rooms. It monitors temperatures, humidity, access, smoke, energy and many other physical ambient parameters. It is a modular system that can be flexibly adapted to meet the customer's specific monitoring requirements. User benefits plus exceptional savings are achieved, thanks to monitoring via the network and the automation of security processes. Further information can be found at: www.rittal.com 2 Processing Unit 2 7 4 9 8 0 446 Rittal Catalogue 4/IT infrastructure

5 6 Processing Unit, see page 449 Power supply Redundant power supply I/O unit power unit PSM measuring bar for direct connection Up to 6 CAN bus systems may be connected vandalism sensor temperature sensor CAN bus sensor for connection of CMC II sensors CAN bus access Up to 6 CAN bus systems may be connected Rittal Catalogue 4/IT infrastructure 447

+ Processing Unit Compact System overview Up to 4 CAN bus components are supported ) sensors for direct connection Mini USB: Programming cable 700.080 is required for programming, see page 457 Internal infrared access sensor 0 CAN bus CAN bus sensor as adaptor for CMC II sensors Processing Unit Compact Voltage supply 24 V (DC) and Redundant voltage supply 24 V (DC) Power packs, see page 457 CAN bus access with integral IR access sensor Alarm relay output: Changeover contact for safety extra-low voltage Ethernet 0/00 BaseT RJ 45 with PoE: Ethernet interface to IEEE 802. Over 0/00 BaseT full duplex 0/00 Mbit/s RJ 2/RS22 accessory modules: Display unit, ISDN unit, GSM unit External temperature sensor (included in the supply of C) Two integral digital inputs CAN bus unit Note: Server shutdown software for is required to shut down the server, see page 46 24 V (DC) 2) Interfaces unit for connecting CMC II accessories Connection for other products, see page 452 2) External 24 V (DC) supply via 700.060 required ) Depending on power supply/ connection combinations, see page 45 CAN bus unit 700.00 448 Rittal Catalogue 4/IT infrastructure

+ Processing Unit System overview CAN bus sensors for direct connection Mini USB: Programming cable 700.080 is required for programming, see page 457 0 Internal infrared access sensor CAN bus sensor as adaptor for CMC II sensors CAN bus 2 SD card insert: for data logging Processing Unit CAN bus access with integral IR access sensor Voltage supply 24 V (DC) and redundant voltage supply 24 V (DC) Power packs, see page 457 Alarm relay output: Changeover contact for safety extra-low voltage Ethernet 0/00 BaseT RJ 45 with PoE: Ethernet interface to IEEE 802. via 0/00 BaseT full duplex 0/00 Mbit/s RJ 2/RS22 accessory modules: Display unit, ISDN unit, GSM unit Up to 6 CAN bus systems are supported ) External temperature sensor (included in the supply of ) USB master for data logging and update ) Depending on power supply/connection combinations, see page 45 Two integral digital inputs Up to 6 CAN bus systems are supported ) Control units CAN bus unit I/O unit power unit 2 24 V (DC) 2) Contains 8 digital inputs 2 and 4 relay outputs Functions: Switching and measuring voltage, current, power and work With two outputs Also for the activation of fans Interfaces unit for connecting CMC II accessories Connection for other products, see page 452 2) External 24 V (DC) supply via 700.060 required I/O unit 700.040 Power unit 700.050 CAN bus unit 700.00 Rittal Catalogue 4/IT infrastructure 449

Processing Unit/Compact System overview Page 448/449 Basic modules and connection accessories Page 45 Redundant voltage supply, plus Power over Ethernet (PoE) Simple wiring with CAN bus connection system (RJ 45) Connection to control roomsystems via OPC UA Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 705 Protection category IP to IEC 60 529: IP 0 Supply includes: Basic system Quick-start instructions 4 mounting feet Approvals: culus Photo shows a configuration example with equipment not included in the scope of supply Processing Unit Processing Unit Compact W x H x D mm 8 x 40 ( U) x 20 + 2 (front assembly) 8 x 40 ( U) x 20 + 2 (front assembly) Operating temperature range 0 C +45 C 0 C +45 C Operating humidity range 5 95 % relative humidity, non-condensing 5 95 % relative humidity, non-condensing Sensors/CAN bus connection units max. 2 max. 4 Max. overall cable length for CAN bus 2 x 50 m x 50 m 700.000 700.00 Interfaces Inputs and outputs Operation/ signals Protocols Redundant power supply Functions Integral sensors Network interface (RJ 45) Ethernet to IEEE 802. via 0/00BaseT with PoE Ethernet to IEEE 802. via 0/00BaseT with PoE Front USB interface Mini USB for system setting Mini USB for system setting Rear USB interface For USB stick for data records and SW updates up to 2 GB Front SD-HC slot x up to 2 GB for data recording Rear serial RS22 (RJ 2) x for the connection of x for the connection of display unit, GSM unit or ISDN unit display unit, GSM unit or ISDN unit CAN bus (RJ 45) 2 x for max. 6 sensors each = 2 sensors in total (quantity restriction, see page 45) x for max. 4 sensors (quantity restriction, see page 45) Digital inputs (terminal) 2 2 Relay output (terminal) Changeover contact max. 24 V (DC), A Changeover contact max. 24 V (DC), A Push-button x acknowledgement button x acknowledgement button Concealed reset button x service button x service button Piezo signal generator LED display x multi-colour OK/warning/alarm x multi-colour OK/warning/alarm Rear LED x for the network status x for the network status Ethernet TCP/IPv4, TCP/IPv6, SNMPv, SNMPv2c, SNMPv, Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS, SMTP, Syslog, LDAP TCP/IPv4, TCP/IPv6, SNMPv, SNMPv2c, SNMPv, Telnet, SSH, FTP, SFTP, HTTP, HTTPS, NTP, DHCP, DNS, SMTP, Syslog, LDAP Input 24 V DC (jack) x for connecting power pack x for connecting power pack x for direct connection or x for direct connection or Input 24 V DC (terminals) for connecting power pack for connecting power pack Power over Ethernet PoE x 5.4 W x 5.4 W Time function Real-time clock, energy-buffered (24 h) without battery/accumulator, with NTP Real-time clock, energy-buffered (24 h) without battery/accumulator, with NTP User administration LDAP LDAP User interface Integral WEB server Integral WEB server Control room connection Integral OPC UA server Integral OPC UA server Temperature sensor NTC sensor with cable, supplied loose NTC sensor with cable, supplied loose Access sensor Infrared technology in the enclosure front Infrared technology in the enclosure front 450 Rittal Catalogue 4/IT infrastructure

Control units for Processing Unit Sensors/accessories Compact Page Maximum quantity I/O Unit, 8 digital inputs + 4 relay outputs 700.040 6 454 Power Unit, input (C4) + 2 outputs (C) 20 V, 50/60 Hz For switching 0 A total current (fan/heater etc.) For measuring current, voltage, power, energy 700.050 6 454 Also required: CAN bus connection cable 700.090/.095, see page 457 Mounting unit, U, 700.070, see page 458 sensors for direct connection Compact Page Maximum quantity Temperature sensor with external sensor 700.0 4 2 454 Temperature/humidity sensor 700. 4 2 454 Infrared access sensor 700.20 4 2 454 Vandalism sensor 700.0 4 2 454 Analog airflow sensor 700.40 4 0 ) 454 Analog differential pressure sensor 700.50 4 2 454 Universal sensor (2x digital input and 4 20 ma) 700.90 4 2 454 ) Max. 5 pieces for power supply with PoE Also required: CAN bus connection cable 700.090/.095, see page 457 Interface for CMC II sensors Compact Page Maximum quantity CAN bus sensor 700.00 4 2 For connecting the following products: 5 x access sensors (packs of 2), connect a max. of 5 in series 720.50 455 x smoke detector 720.560 455 x motion detector 720.570 455 x leakage sensor 720.60 455 x leakage sensor, with sensor length 5 m 720.6 455 / x fire detector and extinguisher system DET-AC Plus with messages 78.20 47 / x early fire detector system DET-AC Plus with messages 78.220 47 /2 x door control system for one rack 720.790 460 Also required: CAN bus connection cable 700.090/.095, see page 457 Rittal Catalogue 4/IT infrastructure 45

Accessories Access system The CAN bus access is designed for one door. It has an integral IR access sensor and may be connected to one handle system and one reader unit. Compact Page Maximum quantity CAN bus access 700.200 2 6 ) For connection to handle: x TS 8 handle with master key function 720.72 2 6 ) 455 For connection to reader unit: x coded lock 700.220 2 6 ) 455 x transponder reader 700.20 2 6 ) 455 ) Max. 5 pieces for power supply with PoE Also required: CAN bus connection cable 700.090/.095, see page 457 Interface for PSM, PCU The products listed may be connected to the / Compact via CAN bus unit 700.00, see page 456. Compact Page Maximum quantity CAN bus unit 700.00 4 456 For connecting the following products: 2 x 4 x Rittal Power Control Unit (PCU) 8-way 7200.00 42 2 x 4 x Rittal Power Control Unit (PCU) C LED, 8-way 7859.225 42 2 x 4 x Rittal Power Control Unit (PCU) C/9 LED, 6-way 7859.25 42 2 x 4 x PSM socket module C, 8-way 7856.20 4 2 x 4 x PSM socket module C/earthing-pin, 6-way 7856.20 4 2 x 4 x PSM socket module C/9, 6-way 7856.204 4 2 x 4 x PSM socket module C/earthing-pin LED, 6-way 7859.22 4 2 x 4 x PSM socket module C LED, 8-way 7859.222 4 2 x 4 x PSM socket module C/9 LED, 6-way 7859.22 4 Accessories: Power supply unit 700.060 and connection cable 7200.20, see page 457 CAN bus connection cable 700.090/.095, see page 457 Mounting unit, U, 700.070, see page 458 Note: Allow one power pack 700.060 for every CAN bus unit 452 Rittal Catalogue 4/IT infrastructure

PSM and slave PDU for direct connection Accessories Compact Page Maximum quantity PSM measuring bars 6 A, with 2 infeeds 7859.050 4 8 40 PSM measuring bars 2 A, with infeed 7859.05 4 8 40 PSM MID measuring module 6 A, with 2 infeeds 7859.2 4 8 42 PSM MID measuring module 2 A, with 2 infeeds 7859.2 4 8 42 Slave PDU international, managed, 6 A, 2 x C 7955.90 6 47 Slave PDU international, managed, 6 A, 24 x C, 4 x C9 7955.90 6 47 Slave PDU international, managed, 2 A, 24 x C, 4 x C9 7955.9 6 47 Slave PDU international, managed, 6 A, 8 x C, x C9 7955.9 6 47 Slave PDU international, managed, 6 A, 24 x C, 6 x C9 7955.92 6 47 Slave PDU international, managed, 2 A, 24 x C, 6 x C9 7955.9 6 47 Slave PDU UK, managed, A, 6 x UK 7955.940 6 48 Slave PDU UK, managed, 6 A, 6 x UK, 4 x C9 7955.94 6 48 Slave PDU UK, managed, 2 A, 6 x UK, 4 x C9 7955.942 6 48 Accessories: CAN bus connection cable 700.090/.095, see page 457 Rittal Catalogue 4/IT infrastructure 45

Accessories control units/ sensors Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 705 Protection category IP to IEC 60 529: IP 0 Connection RJ 45 2 x CAN bus Inputs Outputs IO Unit C NC NO C NC NO C NC NO C NC NO C Control unit I/O unit Inputs for earth-free signals Relay output (changeover contact) can handle loads of up to max. 24 V (DC)/ A 8 x digital 4 x relays 700.040 2 Power Unit C Control unit, power unit Switches 2 outputs Measures voltage, current, power, work For controlling and switching fans, heaters, equipment x voltage C4 0 20 V 50/60 Hz 2 x current C Aggregate current max. 0 A 700.050 2 C Temperature sensor External NTC sensor, 2 m cable Measurement range for external sensors: -40 C +80 C 700.0 C Temperature/humidity sensor Measurement range: 0 C +55 C/ 5 % relative humidity... 95 % relative humidity 700. Infrared access sensor Monitoring and reflector on the door, spacing adjustable 700.20 Vandalism sensor Axis: x, y, z Acceleration limits: -7 7 g, adjustable 700.0 Analog airflow sensor External airflow sensor: 4 20 ma Measurement range: 0.5 5 m/s Application: Fan, filter, climate control devices 700.40 P 2 Analog differential pressure sensor 2 pressure measuring points (infeed via hose) Measurement range: -500 m Pa +500 m Pa Application: Cold aisle containment, raised floor Universal sensor Choice of digital inputs for an application: Earth-free signals S 0 Input for energy measurement systems Wiegand interface (external access systems) 700.50 2 x digital may be switched over to pulse input S 0 or a Wiegand interface x analog 4 20 ma 700.90 454 Rittal Catalogue 4/IT infrastructure

Accessories Interface for sensors Connection RJ 45 2 x CAN bus Input RJ 2 Output RJ 2 CAN Bus Sensor 2 CAN bus sensor For connecting one CMC II sensor x 700.00 2 CMC II access sensor Sensor: Reed contact/magnet Max. 5 reed contacts in series 2 m cable included with the supply x 720.50 CMC II smoke detector Sensor: Visual 2 m cable included with the supply x 720.560 4 CMC II motion detector Sensor: Infrared 2 m cable included with the supply x 720.570 5 6 CMC II leak sensor Sensor: Point infrared sensor 2 m cable included with the supply x 720.60 CMC II leak sensor 5 m Sensor: 5 sensitive cables 2 m cable included with the supply x 720.6 Access system Connection Inputs Outputs RJ 45 2 x CAN bus RJ 2 Flat-pin connector RJ 2 Flat-pin connector CAN Bus Access 2 CAN bus access For connecting one handle and one reader unit for door monitoring Integral IR access sensor x x 700.200 2 4 Handles TS 8 handle with master key function Handle monitoring Rated voltage: 24 V (DC) m cable, 2 m extension cable included with the supply x 720.72 5 reader units Coded lock Transponder reader Numerical code from 0 8 digits may be selected Transponder technology: Mifare m cable included with the supply x 700.220 700.20 Rittal Catalogue 4/IT infrastructure 455

Accessories Interface for PSM, PCU Material: Plastic Surface finish: Front: Smooth Enclosure: Textured Colour: Front: RAL 9005 Enclosure: RAL 705 Protection category IP to IEC 60 529: IP 0 Connection RJ 45 2 x CAN bus Inputs CAN Bus Unit C + CAN bus unit For connecting: PSM socket strips PCU 482.6 mm (9 ) socket strips 2 x for PSM, PCU, see page 452 For operating the required connection clamp for the 24 V power pack 700.060 700.00 2 CAN Bus DRC C + CAN bus DRC For connecting: RFID controller 7890.500 Max. x RFID controller, see page 462 Connection clamps for the 24 V power pack (optional) 700.060 700.550 2 PSM MID measuring module see page 42 New 456 Rittal Catalogue 4/IT infrastructure

Accessories Power supply unit for, Compact, CAN bus unit, CAN bus DRC, Door Control System. Technical specifications: Input voltage: 00 240 V / 50/60 Hz Output voltage: 24 V (DC)/2.5 A Length of 24 V DC connection cable: 0.6 m Supply includes: 4 mounting feet Packs of pc(s). 700.060 Also required: Connection cable, see page 457 Accessories: Mounting unit, see page 458 Programming cable For commissioning the Processing Unit () or Compact. Supply includes: CD with driver and system description Packs of pc(s). 700.080 CAN bus connection cable This can be used to connect the with the CAN bus sensors III, units III, control units III as a bus. Also for cabling the CAN bus sensors III, units III, control units III together. CAN bus connection cable Length m Packs of RJ 45 0.5 pc(s). 700.090 RJ 45 pc(s). 700.09 RJ 45.5 pc(s). 700.092 RJ 45 2 pc(s). 700.09 RJ 45 pc(s). 700.480 RJ 45 4 pc(s). 700.490 RJ 45 5 pc(s). 700.094 RJ 45 0 pc(s). 700.095 Connection cable/extension For connecting to: power pack C power unit C PCU C9 PDU C9 Technical specifications: PVC cable, -pole, with IEC cable coupling (non-heating appliances) with contact protection CEE22 Length: Minimum.8 m Country Version Voltage Volt Packs of D/F/B/C 20 pc(s). 7200.20 Non-heating appliance extension C/C4 Connection cable D/C9 Connection cable C9/C20 20/5 pc(s). 7200.25 20/5 pc(s). 7200.26 20/5 pc(s). 7200.27 Rittal Catalogue 4/IT infrastructure 457

Accessories Extension cable RJ 2 with RJ 2 connector/jack To extend the cable connections to CMC II sensors. Length m Packs of 2 pc(s). 720.84 Mounting unit, U To accommodate Compact Control units CAN bus unit CAN bus DRC power pack Can accommodate up to units and is attached to the 482.6 mm (9 ) frame. Material: Sheet steel Surface finish: Zinc-plated Supply includes: 2 blanking covers Packs of pc(s). 700.070 Accessories: Cable clamp strap 760.000, see page 458 Cable clamp strap For rear attachment on the mounting unit. Material: Sheet steel, 2 mm Surface finish: Zinc-plated Supply includes: Assembly parts Packs of pc(s). 760.000 Mounting unit To accommodate Compact Control units CAN bus unit CAN bus DRC power pack Can accommodate one unit and is mounted on the enclosure frame. Material: Sheet steel Surface finish: Zinc-plated Packs of pc(s). 700.07 458 Rittal Catalogue 4/IT infrastructure