Technical Data Sheet OPUS A6 ECO Basic

Similar documents
Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB,

Technical Data Sheet OPUS A6 ECO Full TDS OPUS A6eF,

Technical Data Sheet OPUS A3 ECO Full

Technical Data Sheet OPUS A3 ECO Basic

Technical Data Sheet OPUS A6 STANDARD Full

Technical Data Sheet OPUS A3 ECO Basic TDS OPUS A3eB,

Technical Data Sheet OPUS A3 STANDARD Full

Technical Data Sheet OPUS A6 STANDARD Full TDS OPUS A6sF,

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A3 STANDARD Basic TDS OPUS A3sB,

Technical Data Sheet OPUS A6 ECO Full

Technical Data Sheet OPUS A8 STANDARD Full TDS OPUS A8sF,

Technical Data Sheet OPUS A3 ECO Full

Technical Data Sheet OPUS A6 ECO Basic

Technical Data Sheet OPUS A8 ECO Basic

MultiViu Flex 4 Data Sheet

Technical Data Sheet OPUS A8 ECO Full

Technical Data Sheet OPUS A3 STANDARD Basic

Technical Data Sheet OPUS A6 STANDARD Full

I /O. OPUS A6s - For Perfectionists IP 65 IP "

Operating Manual HMI 4 HMI 4. Operating Manual Hardware Description INTER CONTROL GmbH & Co. KG

DSEM870. DSEControl PROGRAMMABLE DISPLAY FOR USE IN VEHICLES AND OFF-HIGHWAY MACHINERY

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Control Panel CP600-eCo CP604, CP604-B

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 7 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Programmed with Eaton Pro-FX Control Software 32-bit Processor, 4.3 WVQA Sunlight Viewable Display

Control Panel CP600 CP635, CP635-B, CP635-WEB

Control Panel CP600 CP651, CP651-WEB

PowerView Model PV485. Installation Manual Section 78

Control Panel CP600 CP635-FB, CP635-FW

IRMA MATRIX Release 2

CCD1100S. Technical Data Sheet

Installation instructions Process and dialogue module PDM360 NG CR1080 CR9223 CR1081 CR9224 CR CR1084 CR9226 CR1085 CR9227

2 Control Equipment for General Applications

DATA SHEET Advanced Graphical Interface, AGI 100 series

HelmView 450 Model HV450. Installation Manual Section 78

Operating Instructions 12/2010 MN Z-EN XV-152 MICRO PANEL

A-307. Mobile Data Terminal. Android OS Platform Datasheet

CDC2000X. Technical Data Sheet

2 Device description. 2 Device description 2.1 Function. 2.1 Function. 2.2 Intended use. 2.3 Device versions

PRELIMINARY. USB1 / USB2 USB host interface to read data via memory stick. Bus Out (system bus) For connection to a router

MCX06C Programmable controller

Valueline Industrial PC

HelmView Model HV750. Installation Manual Section 78

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

MRS Electronic, Inc Winner Circle Dayton, OH (937) Datasheet CAN Relay Box 16. Page 1 of 8 Version 1.

HMISTO " wide screen touch panel, Ethernet

NOVOHALL Transducer 5 up to 50 mm touchless. Series TFD-4000

Inclination sensors 2-dimensional, measuring range up to ±90

F1000 User's Manual. (Version: V1.01)

HelmView Model HV750; HVS750. Installation Manual Section 78

MRS Electronic GmbH. Datasheet CAN I/O & CAN PLC CAN I/O & CAN PLC. CAN I/O & CAN PLC Site 1 of 5 Version 1.0

DATA SHEET Advanced Graphical Interface, AGI 100 series

Evo2. Free programmable room controller. Summary

TECHNICAL DATASHEET #TDAX050000K CAN

Inclination sensors 1-dimensional, measuring range

CCPILOT PRODUCT CATALOG 2018 AN ACTUANT COMPANY

Absolute Encoders Multiturn

D E C E M B E R

Page 1 of 11 Version 1.2 Release Date: PenMount PM2204 PCI Controller Board Data Sheet. Table of contents

Solid State Battery Fuel Gauge

Electronic Control Unit RC

KS 108 flexible Compact PLC with touch operating screen

Features. Intel 45nm Atom Processor N270: 1.6 GHz

PCAN-TJA1054 Bus Converter High-Speed CAN to Low-Speed CAN. User Manual. Document version ( )

General Operating, Maintenance and Installation Manual

VESA 75/75 or 100/100 (full metal housing only); fastening clips (built-in-variant only)

DATA SHEET Advanced Graphical Interface, AGI 300 series

IRMA MATRIX Release 2 Data sheet

KS 108 easy Compact automation unit for industrial control and process technology

Page 1 of 13 Version 1.5 Release Date: PenMount PM1410 PCI Controller Board Data Sheet. Table of contents

XC-CPU-201 XC-CPU-201-XV

AT200V3 Vehicle Tracking Device. Version 3.x Hardware. User Guide

Programmable controller Type MCX06C

DATASHEET. 48.3cm (19 ) POS-LINE MONITOR. DATA DISPLAY GROUP

Mobile Automation. Products and Services. We automate your success.

WP4200 Platform. control systems. CPU module for WP42xx Systems and Concepts. High performing controller for all types of turbines

Linear Position Transducer HLT 1000-R2

DATASHEET. 38.1cm (15 ) POS-LINE MONITOR. DATA DISPLAY GROUP

1/2 Description XV400 Flexible in Application

CCpilot XA CCpilot XS CrossCore XS

The modems are made in industrial 108mm wide aluminium housing for DIN rail mounting. UCM RS232 interface

Sturdy aluminium housing, aodized in black. LED red (-): Measuring value < lower tolerance threshold

PRODUCT OVERVIEW. Industrial Grade Monitors. POS-Line 15 up to 65. Brilan 4K 75. Fire Load Optimized. Monitors 32 up to 55.

Note : Power consumption and sample rate will vary according to different firmware versions.

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Touch Displays, Line COP 400

Installation / Control / Monitoring Technique

PCAN-B10011S Bus Converter High-speed CAN to Truck-Trailer CAN. User Manual V2.0.0

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

General information. Display. Supply voltage. Input current

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Hardware Manual RM Display 2501 S01..S04

DI572 Digital Input Module

Programmable controller MCX06C

Hardware Manual RM Display 2401

DI561 Digital Input Module

Instruction book IQAN-LST. Publ no HY /UK Edition 0301

Transcription:

Technical Data Sheet OPUS A6 ECO Basic TDS OPUS A6eB, 20.02.2015 OPUS A6 ECO Basic 20.02.2015 Wachendorff Elektronik Industriestraße 7 DE-65366 Geisenheim

1 Order Numbers OPUS A6 ECO Basic Wachendorff Elektronik Wachendorff Projektor Landscape Landscape with touch CoDeSys Landscape Landscape with touch ISO-VT Landscape Landscape with touch Remark 2 Mechanical 2.1 Dimensions OPUSA6EN1CANB000, OPUSA6EL1CANB000 OPUSA6EN1CANT000, OPUSA6EL1CANT000 OPUSA6EN1CDSB000, OPUSA6EL1CDSB000 OPUSA6EN1CDST000 OPUSA6EN1ISOB000, OPUSA6EN1ISOF000 OPUSA6EN1ISOT000 The neutral Versions will substitute the portrait and landscape versions. 20.02.2015 Wachendorff Elektronik Industriestraße 7 DE-65366 Geisenheim

2.2 Housing Plastic housing, coloured light grey (RAL 7035) with black rubber frame 2.3 Mounting landscape or portrait standalone in-dash 3 Display Type Size Mounting accessories (not included): In-Dash mounting frame (OPUSA6ZBEB001) Standalone mounting adaptor for RAM mounting system (OPUSA6ZBAH001) TFT Color Graphic LCD with LED backlight 7, 152 mm (W) x 91 mm (H) Resolution 800 x 480 px (WVGA), 15:9 Colours Brightness 262k typ. 400 cd/m² Contrast Ratio typ. 500:1 4 Input Devices 4.1 Touch analogue resistive (OPUSA6EN1CANT000, OPUSA6EL1CANT000, OPUSA6EN1CDST000 and OPUSA6EN1ISOT000 only) 5 Electronics 5.1 Processor platform CPU Mass storage RAM RTC Freescale I.MX35, 532 MHz 512 Mbyte (approx. 450 MB for customer use) 128 Mbyte buffered by gold cap 5.2 Buzzer 65 db(a) in 30 cm distance lifetime min. 1000h 5.3 Interfaces 5.3.1 Power supply Operating voltage range Protection Overvoltage resistance Inverse polarity protection System supplied through terminal 30 (battery +, see pinout) and 31 (battery -, see pinout). Terminal 15 (ignition) to be used to switch on/off. 9 36 V DC short circuit protection 48V for max. 2 minutes up to -48 V DC for max. 5 minutes Current consumption (without external load), max Power Mode current at 13,5 V DC current at 27 V On 900 ma 500 ma Low-power 200 ma 120 ma Sleep 100 ma 65 ma Off <3 ma <3 ma 5.3.2 Can Interfaces 2 x CAN-Interfaces ISO 11898, CAN-specification 2.0 B active, up to 1 Mbit/s (default 250 Kbit/s, 500 Kbit/s, 750 Kbit/s and 1 Mbit/s) 5.3.3 RS232 1 x RS232-Interface Type Speed EIA232 (only RxD, TxD, GND) max. 115 Kbps 5.3.4 USB Host 2.0 Main connector 1 x Full speed 20.02.2015 Wachendorff Elektronik Industriestraße 7 DE-65366 Geisenheim

5.3.5 Video-Interface analog video input, 1 Vss camera control output (open drain) for special functionality (mirror, shutter, heating etc.), ampacity 300mA @ 12V DC 5.3.6 Ethernet-Interface 1 x 10/100 Mbit/s Base T 6 Connections Main connector Tyco-AMP 1437288-6 Mating connector (customer) Tyco-AMP 3-1437290-7 Mating crimp contact (customer) Tyco AMP 3-1447221-4 Video connector M12 round connector, female, 5-pole, B-coded acc. to EN 61076-2-101 Ethernet connector M12 round connector, female, 4-pole, D-coded acc. to EN 61076-2-101 Connector pinout see chap. 9. 7 Software 7.1 Operating System Linux, kernel 2.6.28 7.2 Application Programming Wachendorff Projektor Tool Optional: Codesys-Tools (3.5) Optional: ISO-VT Optional: C/C++ 8 Testing and Verification 8.1 CE-Compliance EU Directive 2004/108/EC (EMC) according to EN 12895: Industrial Trucks Electromagnetic compatibility EN 13309: Construction machinery Electromagnetic compatibility of machines with internal electrical power supply EN ISO 14982: Agricultural and forestry machinery - Electromagnetic compatibility - Test methods and acceptance criteria 8.2 E1 - Type approval EU Directive ECE R 10.4 (Dec 2013) 8.3 Protection Level (IP Code) IP 6k5 and IP 6k7 according to ISO 20653: Road Vehicles Degrees of protection (IP-Code) Protection of electrical equipment against foreign objects, water and access 8.4 Electrical 12 and 24V-Systems according to: ISO 16750-2: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Electrical loads ISO 15003: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions 8.5 Mechanical According to ISO 16750-3: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Mechanical loads, Code L ISO 15003: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions o Mechanical Shock: Level 2 o Random Vibration: Level 2 o Sinusoidal Vibration: Level 2 8.6 Climate According to ISO 16750-4: Road Vehicles Environmental conditions and testing for electrical and electronic equipment Climatic Loads o Operating Temperature Range: -30 +65 C o Storage Temperature Range: -40 +85 C ISO 15003: Agricultural Engineering Electrical and electronic equipment Testing resistance to environmental conditions 20.02.2015 Wachendorff Elektronik Industriestraße 7 DE-65366 Geisenheim

9 Pinout 9.1 Main connector pinout pin no. assignment description 1 VCC supply voltage +; terminal 30 2 Ignition Input ignition input; terminal 15 3 GND supply voltage - ;terminal 31 4 CarGND Car GND 5 n. c. Not connected 6 n. c. Not connected 7 n. c. Not connected 8 CAN1H CAN 1 high 9 CAN1L CAN 1 low 10 CAN2H CAN 2 high 11 CAN2L CAN 2 low 12 USB_VCC USB +5V supply 13 USB_GND USB supply GND 14 USB_D- USB Data - 15 USB_D+ USB Data + 16 RS232 RxD RS232 receive data 17 RS232 TxD RS232 transmit data 18 RS232 GND RS232 GND 19 n. c. Not connected 20 n. c. Not connected 21 n. c. Not connected 22 n. c. Not connected 23 SERV_EN service enable 24 n. c. Not connected 25 n. c. Not connected 26 n. c. Not connected view on rear side of the A6 20.02.2015 Wachendorff Elektronik Industriestraße 7 DE-65366 Geisenheim

9.2 Video connector pinout Round Connector, 5 pins, M12 1 VidSig+ 2 Mirror 3 Camera+ 4 Camera - 5 VidSig GND Video- Connector, M12, female, 5 pins, b-coded, view on rear side of the A6 9.3 Ethernet connector pinout Round Connector, 4 pins, M12, acc. To IEC 61076-2-101 1 TD+ 2 RD+ 3 TD- 4 RD- Ethernet Connector, M12, female, 4 pins, d-coded, view on rear side of the A6 20.02.2015 Wachendorff Elektronik Industriestraße 7 DE-65366 Geisenheim