Appendix E: Edge Ti. Overview. Appendix E: Edge Ti 169

Similar documents
Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

User s guide. Torch height controller. Model : THC Controller

USER S MANUAL VER.2. C76- MULTIFUNCTION CNC BOARD Rev. 1.4

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

ReFlx. ReFlx 100 Collision Avoidance System Instruction Manual Page 1 6/30/99

Centroid ACORN CNC controller Specification and Use Guide Updated 8/3/17. Overview

ACORN User Guide For Revision (Aka Acorn_rev3) Updated 1/23/17

Trigger I/O Board for the LogiComm Gun Driver

ReFlx 100 PLUS COLLISION AVOIDANCE SYSTEM

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

DG2S series. User s Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty.

C10- PARALLEL PORT INTERFACE CARD Rev. 8

PLCADD1616 User Guide 3/29/10. Overview

AXIMA Installation Manual

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

ADVANCED MICRO SYSTEMS

1. Introduction ALSPA MV DELTA

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

Mounting Card MC1XDZR02-HP1

Release Note. How to Use the OptoCon Connection Module. 1 Introduction. Option C Revision 4 Revised 8/13/98

AxCent Retrofit Large Size Models

AG300 Family CTL01-3A-03, AMP01-2A-02

DC3IOB Revision User Guide Updated 7/12/12. Overview

4Trio Motion Technology3

R325P Single Axis Driver

DC3IOB Revision User Guide Updated 3/29/10. Overview

UCBB dual port breakout board user's manual

170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0

Mounting Card MC1XDZR02-QD

INSTALLATION INSTRUCTIONS

Ndrive Linear Series. Digital Servo Amplifiers Linear. Output power range of 10 or 20 A peak with ±10 to ±80 VDC bus

Central-I Family. CiG1-AMP01-1A-01-00

2017 DIY Controls for a CNC Plasma Cutting Table

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

SPiiPlusEC Network Manager Installation Guide November2014 Document Revision: 02

Notes on safety: Improper use or disregard of these warnings may result in the injury or death of people.

PLC Racks IC697CHS782/783

ACR8020 Hardware Manual

Plasma Control. Industrial Motion Control. Control Software Features. Optional Part Nesting. MachMotion.com

Mounting Card MC1XDZC02

Hypertherm Shape Cutting Control

Overview Included in the Box: Pinout Installation Power Supply Stepping Motors DIP Switch (JP1) Location...

G540 User Manual. Date Modified: March 5, 2012 Page 1 of 10

Hardware Manual CNC760

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Version 1.9. Reference for Part Numbers: EQUBE-P EQUBE-N EQUBE-AI-P

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

C45 - LIMIT AND HOME UNIVERSAL BOARD Rev. 1

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS

DG4S series DC Servo drive

Model 7705 Control Module

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

USER S MANUAL. M16 POKEYS MOTION MOTHERBOARD Rev. 1.1 JUNE 2016.

WOODINVILLE, WA SUPERSTEP 2100 SERIES SEQUENCING PROPORTIONAL LOAD CONTROLLERS INSTALLATION & OPERATING MANUAL. Models: SLC2102-SLC2112

Galil Motion Control. DMC - 500x0. Datasheet. Galil Motion Control 270 Technology Way, Rocklin, CA [Type here] [Type here] [Type here]

24/48/120 VAC Interface Card Instruction Manual

C35- QUICK SETUP BREAKOUT BOARD Rev. 1.1

Central-I Family. CiG1-AMP01-1A-01-00

EDGE Connect Customized shape cutting control

midon design A 1-Wire Multi-purpose Sensor 1WIO Figure 1 MD2083 As-Shipped August 23, WIO User Guide Version 1.

MODEL DRIVER Ic Ip VDC

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

PLCIO2 Programmable Logic Controller Updated 3/26/10

C-Series C142 Machine Controller Eurocard DIN Packaged Systems

Hardware User s Manual. Digital Video Motion Detector DVMD1-X

SD DRIVE SERIES INSTALLATION MANUAL

USER S MANUAL VER.1. C34GV BOARD Rev. 1

EZ-24 EZ-24-HTB EZ-24-HTBS. Version May Publication PR-1100

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL. Total System Manager

KBMG MULTI-SPEED BOARD

Installation & Setup Guide

Model 500 Series Laser Diode Driver User's Manual

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

RTK3 Logic Controller User Manual Revised

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

6222 Two Door Module Technical Operations Manual

HDBB Breakout board user s manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

SAVE THESE INSTRUCTIONS

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

PP-BOB2-V1.0 PARALLEL PORT BREAKOUT BOARD

MT8050iE series. Installation Instruction (1) (2)

TECHNICAL PRODUCT DATASHEET

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

AXIMA 2000/4000 Installation Manual

PCL-725 Relay Actuator and Isolated D/I Card USER'S MANUAL

BENCHMARK MEDIA SYSTEMS, INC.

PMC Controller Electrical Manual

Trouble Shooting Leveling Control Box Electric Jacks. Touch Pad LED Probable Cause Solution

The SilverNugget is a servo controller/driver for NEMA 17 & 23 frame microstep motors.

C50- PARALLEL PORT INTERFACE CARD Rev. 1

TSM23P. Integrated Step-Servo Motor. Hardware Manual

Installing Your 1394 Drive Interface Module

HYPERTHERM SHAPE CUTTING CONTROL

Allegra Series Reference Manual. Programmable Motion Control System

Transcription:

Appendix E: Edge Ti 169 Appendix E: Edge Ti Overview The Edge Ti shape cutting control is an extremely versatile product offering up to four configurable axes of motion, built-in Servo Amplifiers and configurable I/O. Use of built in relay contacts for I/O increases interface options and minimizes external interface components. Edge Ti Hypertherm Automation PC based CNC controls for the shape cutting industry utilize our proprietary Graphical User Interface (GUI), and SoftMotion Technology to increase productivity, reduce operational costs while providing unsurpassed operational flexibility. The control features may be further expanded through use of integrated Sensor THC interface and networking Touch Screen The 15 display used in the Edge Ti is a patented IntelliTouch Surface Wave technology which provides precise drift free touch accuracy and unsurpassed clarity. Pure glass construction with tiny transducers on the back of the touch screen preserves color purity and works even if scratched. There is no known wear out mechanism as there are no layers, coatings or moving parts. IntelliTouch technology has been tested by the supplier for more than 50 million touches in one location without failure. Rear View THC, Joystick & Speedpots Features for Joystick and Speedpots are offered as standard. Optional features for integrated Sensor THC are available. Note: Use of some devices such as USB memory devices may require loading of a device driver for operation. Many standard device drivers are located in the C:\CABS or D:\CABS\I386 folders. Operation and maintenance of automated equipment involves potential hazards. Personnel should take precautions to avoid injury. This equipment should only be opened by trained service personnel.

170 Installation & Setup Guide Machine Interface The information provided here is the basic information for connection of the shape cutting control to the cutting table. Each machine interface will vary slightly based on the cutting table configuration and features. Additionally, I/O pinout information may vary slightly based on the configuration of the selected I/O and their locations. Changes to the I/O configuration may be made in the password protected I/O screen. All controls are shipped with a default selection of Inputs and interface locations for the selected control Interface (I/O) configuration. Installation and service should only be performed by a qualified service technician. The rear panel of the control has several cable connectors to connect the control to power, I/O and communication ports. These connectors are clearly labeled as to their function. AC Input The AC power cable is inserted into the AC power connector and plugged into a standard 3-way 115 or 230 volt outlet. The AC Power connector contains an integral fuse module and line filter. AC input power can be selected by the user by changing position of the fuse module so that the selected voltage is displayed. A remote communications link can be connected to one of the two serial ports and an external ground (PE) lug for earth grounding of the unit is also provided. Serial Port Please refer to the Ports Information section of the Installation Guide for additional information on configuration of Serial ports for communication. Note: Serial ports for the MicroEDGE are not optically isolated. Appropriate grounding or after market port isolator or protocol converter to add optical isolation is recommended.

Appendix F: Voyager III 171 I/O Configuration The Edge Ti provides several options for I/O interfacing with built in circuitry providing interface flexibility and reducing the need for external components. Inputs are through optoisolators and outputs are through relays. Contacts for both normally closed and normally open outputs are available for use. Note that the inputs have two different modes that are selectable using DIP switch SW1-3. When this switch is OFF the inputs are in the normal mode and an external voltage source of between 12V and 24V is required to activate the input. When DIP switch SW1-3 is ON, the inputs are all in the dry contact mode and require an external switch to common to activate the inputs. The normal logic states are reversed between the two input modes. In the normal mode an inactive input will produce a logic low and an active input will produce logic high. In dry contact mode these logic levels are reversed with an inactive input producing logic high and an active input producing a logic low.

172 Installation & Setup Guide I/O Interface The following illustration shows the details of connecting the I/O to common circuitry. All outputs are relay contacts rated at 1 AMP 250VAC maximum Example Inputs External Circuitry Edge-Ti Internal Circuitry Inputs Outputs Example Outputs External Circuitry Dry Contact Inputs Note: Logic Level Reversal SWITCH Dry Contact Inputs DIP Sw 3-C closed GND +24V Field COM NC NO Use External +12V Supply & normally Closed Contact LED + 12V RESISTOR Normal Inputs Use External +12V Supply Normal Inputs DIP sw 3-C Open Open RELAY SPDT COM NC GND_External GND_External Use External +5V Supply & normally Open Contact + GND NO RESISTOR 5V + 24V + OPTO ISOLATOR 12V GND_External Normal Inputs Use External +24V Supply RELAY Normal Inputs DIP sw 3-C Open GND Open RELAY SPDT COM NC NO RELAY OPTO ISOLATOR Use External 120 Vac & normally open contact GND_External 120 Vac RELAY SPDT GND_External WARNING! Do not exceed 24Vdc or 10mA into any optoisolator input. Use care to observe the correct signal polarities or damage may occur! Do not exceed 250 Vac or 1 Amp through any relay output.

Appendix F: Voyager III 173 I/O Pinout 4 Inputs/outputs per connector Connector I/O 1-3 Connector I/O 4-6 Pin# Signal Pin# Signal 1 OUT1 COM 1 OUT4 COM 2 OUT1 NC 2 OUT4 NC 3 OUT1 NO 3 OUT4 NO 4 OUT2 COM 4 OUT5 COM 5 OUT2 NC 5 OUT5 NC 6 OUT2 NO 6 OUT5 NO 7 OUT3 COM 7 OUT6 COM 8 OUT3 NC 8 OUT6 NC 9 OUT3 NO 9 OUT6 NO 10 IN1 10 IN4 11 IN1 COM 11 IN4 COM 12 IN2 12 IN5 13 IN2 COM 13 IN5 COM 14 IN3 14 IN6 15 IN3 COM 15 IN6 COM 16 Cable Shield 16 Cable Shield Connector I/O 7-9 Connector I/O 10-12 Pin# Signal Pin# Signal 1 OUT7 COM 1 OUT10 COM 2 OUT7 NC 2 OUT10 NC 3 OUT7 NO 3 OUT10 NO 4 OUT8 COM 4 OUT11 COM 5 OUT8 NC 5 OUT11 NC 6 OUT8 NO 6 OUT11 NO 7 OUT9 COM 7 OUT12 COM 8 OUT9 NC 8 OUT12 NC 9 OUT9 NO 9 OUT12 NO 10 IN7 10 IN10 11 IN7 COM 11 IN10 COM 12 IN8 12 IN11 13 IN8 COM 13 IN11 COM 14 IN9 14 IN12 15 IN9 COM 15 IN12 COM 16 Cable Shield 16 Cable Shield I/O Mating Connector The I/O connector is a standard sex circular CPC connector from AMP Connector AMP 16C #206037-1 Backshell AMP #206070-1 Sockets 20-24AWG AMP #66105-3 Shared Inputs Note that that inputs #11 and #12 are shared with the Lifter Interface Limit Switch inputs. These two inputs can only be used as general purpose inputs if they are NOT used by the Lifter Interface limit switches. If you are using the Lifter Interface and limit switches are connected to these inputs you must set DIP switches SW1-1 and SW1-2 to ON and you should not connect to inputs #11 and #12. Note that the standard Hypertherm Lifter does not use limit switches and the DIP switches SW1-1 & SW1-2 should be OFF so that inputs #11 and #12 can be used.

174 Installation & Setup Guide Front Panel I/O Edge TI has dedicated I/O for operation of front panel switches. Input # Description 24 Front Panel Start 25 Front Panel Stop 26 Front Panel Forward on Path 27 Front Panel Forward on Path 28 Raise Torch 1 29 Lower Torch 1 30 Front Panel Manual 31 Front Panel E-Stop For proper operation, these inputs should not be reassigned. Lifter Interface Edge Ti offers the option of an integrated Sensor THC. The lifter interface connector is provided for this use. Pinout: Pin# Description 1 Field +12VDC 2 Lower Limit 3 Upper Limit 4 Breakaway (Torch Collision) 5 Field Common 6 Field Common 7 Contact Sense 8 Contact Sense 9 Contact Sense Shared Inputs Note that that inputs #11 and #12 are shared with the Lifter Interface Limit Switch inputs. These two inputs can only be used as general purpose inputs if they are NOT used by the Lifter Interface limit switches. If you are using the Lifter Interface and limit switches are connected to these inputs you must Close DIP switches SW1-1 and SW1-2 and you should not connect to inputs #11 and #12. Note that the standard Hypertherm Lifter does not use limit switches and the DIP switches SW1-1 & SW1-2 should be left open so that inputs #11 and #12 can be used.

Appendix F: Voyager III 175 Plasma Interface A plasma interface is provided as standard to Plasma Interface Pinout Pin# Description 1 Field +12VDC 2 Field +12VDC 3 Plasma Start (Cut Control) 4 Plasma Start (Cut Control) 5 Hold Ignition 6 Hold Ignition 7 Transfer (Cut Sense) 8 Transfer (Cut Sense) 9 Field Common 10 Field Common 11 Field Common 12 Field Common 13 Field Common 14 Arc Voltage Electrode 15 Arc Voltage Work Mating Connector Connector AMP # Backshell AMP # Sockets AMP External Interlock An external interlock is provided for added safety. Interlock Pinout Pin# Description 1 Interlock Relay Coil 2 GND 3 GND 4 +24VDC (50 milliamps maximum) Additional Notes: 1. For Servo Drive Amplifiers to operate, Pin 1 must be connected to GND Pin 2, typically through a remote mushroom type switch. If no remote switch is to be used, connect pin 1 to pin 2 with a jumper or the servo drives will not power on. 2. 24VDC is provided for use to activate the digital inputs only in the case where, it must not be used for any other auxiliary purpose. Mating Connector Connector AMP #206060-1 Backshell AMP #206062-3 Sockets 20-24AWG AMP #66105-3

176 Installation & Setup Guide Motor Encoder Connections Edge Ti supports DC brush and brushless motors. Switch SW1 on the drive interface can be used to select motro type being used. Please note the location and setting in the following illustration. Axes Assignments Axes Axes Assignment 1 (X) Transverse or Rail 2 (Y) Transverse or Rail 3 (Z) Dual Gantry, CBH, Rotate or THC 4 (W) CBH, Tilt or THC

Appendix F: Voyager III 177 Motor Pinout Pin# Description 1 Brushless Motor-A or Brush + 2 Brushless Motor-B or Brush - 3 Brushless Motor-C 4 Brake + (24VDC, 250ma max) 5 Brake - 6 no connect 7 Cable Shield Additional Notes: 1. Brake output is limited to 250ma total. Drive Motor Mating Connector Connector AMP #211399-1 Backshell AMP #206966-1 Sockets 16-18AWG AMP #66101-3 Cabling: Use Belden # 9501 or equivalent for drive signals Encoder Pinout: 1 Encoder +5V 2 Encoder GND 3 Encoder Channel A 4 Encoder Channel A/ 5 Encoder Channel B 6 Encoder Channel B/ 7 Encoder Channel Z 8 Encoder Channel Z/ 9 +V Hall Out (6V @ 30MA max) 10 Hall GND 11 Hall A 12 Hall - B 13 Hall - C 14 Cable Shield Additional Notes: 1. Only 5 Volt encoders are supported. 2. Hall Sensors are used with Brushless motors only. 3. Inside the Edge Ti, a dipswitch is used to select Brush or Brushless mode, 2 switches per axis. Can mix Brushed and Brushless if switches are set properly. 4. For optimum noise immunity, cable shields may be tied externally to the control enclosure. Encoder Mating Connector and Cable Connector AMP #206044-1 Backshell AMP #206070-1 Pins (20-14AWG) AMP #66103-3 Cabling: Use Belden # 9504 or equivalent for encoder signals

178 Installation & Setup Guide Connector Kits CONN-0161 interlock kit Qty PN Desc 1 CONN-0159 plug 1 CONN-0160 cable clamp 4 CONN-0037 crimp sockets CONN-0162 I/O kit Qty PN Desc 4 CONN-0075 plug 4 CONN-0063 cable clamp 70 CONN-0037 crimp sockets CONN-0163 Motor/Encoder connector kit Qty PN Desc 1 CONN-0158 plug 1 CONN-0049 cable clamp 7 CONN-0050 crimp sockets 1 CONN-0062 plug 1 CONN-0063 cable clamp 16 CONN-0053 crimp pins