IOmark- VDI. IBM IBM FlashSystem V9000 Test Report: VDI a Test Report Date: 5, December

Similar documents
IOmark- VM. IBM IBM FlashSystem V9000 Test Report: VM a Test Report Date: 5, December

IOmark- VM. HP MSA P2000 Test Report: VM a Test Report Date: 4, March

IOmark- VM. HP HP ConvergedSystem 242- HC StoreVirtual Test Report: VM- HC b Test Report Date: 27, April

IOmark-VM. VMware VSAN Intel Servers + VMware VSAN Storage SW Test Report: VM-HC a Test Report Date: 16, August

IOmark-VM. Datrium DVX Test Report: VM-HC b Test Report Date: 27, October

How Architecture Design Can Lower Hyperconverged Infrastructure (HCI) Total Cost of Ownership (TCO)

LATEST INTEL TECHNOLOGIES POWER NEW PERFORMANCE LEVELS ON VMWARE VSAN

INTEL NEXT GENERATION TECHNOLOGY - POWERING NEW PERFORMANCE LEVELS

Introducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile

VMware vstorage APIs FOR ARRAY INTEGRATION WITH EMC VNX SERIES FOR SAN

W H I T E P A P E R. Comparison of Storage Protocol Performance in VMware vsphere 4

NAS for Server Virtualization Dennis Chapman Senior Technical Director NetApp

VMware VAAI Integration. VMware vsphere 5.0 VAAI primitive integration and performance validation with Dell Compellent Storage Center 6.

NEXGEN N5 PERFORMANCE IN A VIRTUALIZED ENVIRONMENT

VMware vsan 6.6. Licensing Guide. Revised May 2017

VMware vsan Ready Nodes

The next step in Software-Defined Storage with Virtual SAN

VMWare Horizon View 6 VDI Scalability Testing on Cisco 240c M4 HyperFlex Cluster System

VMware vsphere 5.0 STORAGE-CENTRIC FEATURES AND INTEGRATION WITH EMC VNX PLATFORMS

VMWARE VSAN LICENSING GUIDE - MARCH 2018 VMWARE VSAN 6.6. Licensing Guide

VMware Virtual SAN. Technical Walkthrough. Massimiliano Moschini Brand Specialist VCI - vexpert VMware Inc. All rights reserved.

EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager

Citrix VDI Scalability Testing on Cisco UCS B200 M3 server with Storage Accelerator

KillTest *KIJGT 3WCNKV[ $GVVGT 5GTXKEG Q&A NZZV ]]] QORRZKYZ IUS =K ULLKX LXKK [VJGZK YKX\OIK LUX UTK _KGX

Stellar performance for a virtualized world

Nutanix Tech Note. Virtualizing Microsoft Applications on Web-Scale Infrastructure

Considerations to Accurately Measure Solid State Storage Systems

XenApp and XenDesktop 7.12 on vsan 6.5 All-Flash January 08, 2018

Evaluation Report: Improving SQL Server Database Performance with Dot Hill AssuredSAN 4824 Flash Upgrades

Surveillance Dell EMC Storage with Digifort Enterprise

A Kaminario Reference Architecture: Reference Architecture for Running SQL Server on ESXi

Pivot3 Acuity with Microsoft SQL Server Reference Architecture

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

Surveillance Dell EMC Storage with FLIR Latitude

Data center requirements

2014 VMware Inc. All rights reserved.

Surveillance Dell EMC Storage with Bosch Video Recording Manager

VMware vsphere 5.5 Advanced Administration

White Paper Effects of the Deduplication/Compression Function in Virtual Platforms ETERNUS AF series and ETERNUS DX S4/S3 series

Surveillance Dell EMC Storage with Cisco Video Surveillance Manager

VMWARE HORIZON 6 ON HYPER-CONVERGED INFRASTRUCTURES. Horizon 6 version 6.2 VMware vsphere 6U1 / VMware Virtual SAN 6U1 Supermicro TwinPro 2 4 Nodes

AccelStor NeoSapphire VDI Reference Architecture for 500 users with VMware Horizon 7

How To Get The Most Out Of Flash Deployments

MongoDB on Kaminario K2

EMC Business Continuity for Microsoft Applications

SAN Storage Evaluation Guide Including Solid State / Flash Storage

Citrix XenDesktop 5.5 on VMware 5 with Hitachi Virtual Storage Platform

Deep Dive on SimpliVity s OmniStack A Technical Whitepaper

VMware Virtual SAN Design and Sizing Guide for Horizon View Virtual Desktop Infrastructures TECHNICAL MARKETING DOCUMENTATION REV A /JULY 2014

Dell EMC. Vblock System 340 with VMware Horizon 6.0 with View

Virtualized SQL Server Performance and Scaling on Dell EMC XC Series Web-Scale Hyper-converged Appliances Powered by Nutanix Software

Nutanix Complete Cluster Reference Architecture for Virtual Desktop Infrastructure

Using IBM FlashSystem V9000 TM with the VMware vstorage APIs for Array Integration

ECONOMICAL, STORAGE PURPOSE-BUILT FOR THE EMERGING DATA CENTERS. By George Crump

Performance Testing of SQL Server on Kaminario K2 Storage

Condusiv s V-locity VM Accelerates Exchange 2010 over 60% on Virtual Machines without Additional Hardware

LEVERAGING FLASH MEMORY in ENTERPRISE STORAGE

Dell EMC SAN Storage with Video Management Systems

Deploying EMC CLARiiON CX4-240 FC with VMware View. Introduction... 1 Hardware and Software Requirements... 2

HyperFlex. Simplifying your Data Center. Steffen Hellwig Data Center Systems Engineer June 2016

VMware Horizon View. VMware Horizon View with Tintri VMstore. TECHNICAL SOLUTION OVERVIEW, Revision 1.1, January 2013

NetApp All Flash FAS Solution for Nonpersistent Desktops with VMware Horizon View

Data Protection for Virtualized Environments

Administering VMware Virtual SAN. Modified on October 4, 2017 VMware vsphere 6.0 VMware vsan 6.2

Why Datrium DVX is Best for VDI

VMware Virtual SAN Technology

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

Dell Storage vsphere Web Client Plugin. Version 4.0 Administrator s Guide

INTEGRATED INFRASTRUCTURE FOR VIRTUAL DESKTOPS ENABLED BY EMC VNXE3300, VMWARE VSPHERE 4.1, AND VMWARE VIEW 4.5

Infinio Accelerator Product Overview White Paper

VMware vsphere APIs for I/O Filtering (VAIO) November 14, 2017

Nutanix Reference Architecture Version 1.1 July 2016 RA-2022

IBM Emulex 16Gb Fibre Channel HBA Evaluation

Soluzioni integrate con vsphere La virtualizzazione abilita il percorso evolutivo di innovazione dell'it

DELL EMC UNITY: DATA REDUCTION

EMC Virtual Infrastructure for Microsoft Applications Data Center Solution

PERFORMANCE STUDY OCTOBER 2017 ORACLE MONSTER VIRTUAL MACHINE PERFORMANCE. VMware vsphere 6.5

EMC Integrated Infrastructure for VMware. Business Continuity

The next step in Software-Defined Storage with Virtual SAN. VMware vforum, 2014 Bünyamin Özyaşar 2014 VMware Inc. All rights reserved.

High-Performance, High-Density VDI with Pivot3 Acuity and VMware Horizon 7. Reference Architecture

Accelerate with IBM Storage: IBM FlashSystem A9000/A9000R and Hyper-Scale Manager (HSM) 5.1 update

Functional Testing of SQL Server on Kaminario K2 Storage

Performance Report: Multiprotocol Performance Test of VMware ESX 3.5 on NetApp Storage Systems

New HPE 3PAR StoreServ 8000 and series Optimized for Flash

Scalability Testing with Login VSI v16.2. White Paper Parallels Remote Application Server 2018

Creating the Fastest Possible Backups Using VMware Consolidated Backup. A Design Blueprint

Fujitsu PRIMEFLEX for VMware vsan 20,000 User Mailbox Exchange 2016 Mailbox Resiliency Storage Solution

What's New in vsan 6.2 First Published On: Last Updated On:

StorMagic SvSAN: A virtual SAN made simple

Data Protection for Cisco HyperFlex with Veeam Availability Suite. Solution Overview Cisco Public

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing

StorageCraft OneXafe and Veeam 9.5

Nimble Storage vs HPE 3PAR: A Comparison Snapshot

Performance Testing December 16, 2017

Administering VMware vsan. 17 APR 2018 VMware vsphere 6.7 VMware vsan 6.7

HPE Nimble Storage HF20 Adaptive Dual Controller 10GBASE-T 2-port Configure-to-order Base Array (Q8H72A)

PRESENTATION TITLE GOES HERE

vsphere Virtual Volumes

Microsoft RemoteFX for Remote Desktop Virtualization Host Capacity Planning Guide for Windows Server 2008 R2 Service Pack 1

vsan Planning and Deployment Update 1 16 OCT 2018 VMware vsphere 6.7 VMware vsan 6.7

Transcription:

IOmark- VDI IBM IBM FlashSystem V9000 Test Report: VDI- 151205- a Test Report Date: 5, December 2015 Copyright 2010-2015 Evaluator Group, Inc. All rights reserved. IOmark- VDI, IOmark- VM, VDI- IOmark, and IOmark are trademarks of Evaluator Group, Inc. in the United States and other jurisdictions. www.iomark.org

2 IOmark- VDI Test Report Table of Contents Executive Summary... 3 Vendor Product Description... 3 IBM FlashSystem V9000... 3 IOmark- VDI Test Summary... 4 IOmark- VDI Results... 5 Tested Configuration Details... 6 Hypervisor Configuration for IOmark- VDI Workload... 6 Storage Configuration for IOmark- VDI Workload... 7 Configuration Diagram... 8 Connectivity... 9 Tested Configuration Pricing... 10 Detailed Results... 11 Why the Need for IOmark- VDI... 13 How IOmark- VDI Operates... 13 Benchmark Application Workload Set... 14 VDI Workload... 14 VDI Benchmark Parameters... 14 VDI Workload Generation... 14 VDI Workload Details... 15 Understanding Results... 15 Benchmark Criteria... 15 More Information about IOmark- VDI... 16 About Evaluator Group... 16 IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

IOmark- VDI Test Report 3 Executive Summary IOmark is a storage specific workload and benchmark designed to test storage systems performance using a variety of real world, application centric workloads. The IOmark- VDI benchmark is a specific workload that measures Virtual Desktop Infrastructure (VDI) workloads against storage systems. Results are published after audit and certified approval by IOmark authorized auditors. IOmark- VDI is a benchmark that certifies storage systems for VDI results. The measurement criteria are storage performance, with the restriction that all storage workloads must be supported by the tested system. Although there are CPU and memory considerations, these aspects are not tested by IOmark- VDI workload. This document is the official benchmark report for the tested configuration using IBM V9000 FlashSystem appliance. The result of the benchmark showed the tested solution supported 4,096 simultaneous, virtual desktop instances at a cost of $183.59 per VDI instance, meeting the storage response time requirements. The system also supported 3,072 VDI fully provisioned instances while meeting the storage performance requirements. A full description of the configuration tested along with pricing information are provided in the following document, with application workload details in Appendix A. The criteria and performance requirements are as follows: For all application workloads: o All workloads must reside entirely on the tested system o 70% of response times for I/O s must not exceed 30ms o The replay time must complete within 1 hour and 5 minutes for each 1 hour workload Vendor Product Description IBM FlashSystem V9000 IBM FlashSystem V9000 is a comprehensive all- flash enterprise storage solution. FlashSystem V9000 delivers the full capabilities of IBM FlashCore technology plus a rich set of storage virtualization features. FlashSystem V9000 delivers industry- leading value to enterprises along three dimensions: Performance, Economics, and Integration. The V9000 FlashSystem is production- ready within 15 minutes and can be used for any virtualization project where simplicity is key. The IBM V9000 FlashSystem features the following: Three dimensions of value: Scalable Performance, Enduring Economics, Agile Integration Accelerate time to value with agile, easy- to- implement, fully- integrated systems Data protection with a full suite of DR tools including snapshots, clones and replication Provides advanced virtualization, provisioning and performance management with IBM Virtual Storage Center IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

4 IOmark- VDI Test Report IOmark- VDI Test Summary For the tested configuration, the following data is provided Item Value Testing Identifier: Product: Test Sponsor: Auditor: VDI- 151205- a IBM FlashSystem V9000 IBM Corporation Evaluator Group Inc. Table 1: Test Identifier Information Item Value IOmark- VDI Version: IOmark- VDI 3.8 Testing Completed: November 2015 Equipment Availability: December 2014 Audit Certification Date: 1, December 2015 Report Date: 5, December 2015 Table 2: Test Revision and Dates IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

IOmark- VDI Results IOmark- VDI Test Report 5 Shown below are the IOmark- VDI results for the system under test. The definition and workload characteristics of the benchmark are provided in Appendix A. Price information provided below is explained in detail in Table 7 in this report. A VDI user may be configured to run in one of two modes: Fully Provisioned (No clones - Requires at least 14 GB of thinly provisioned capacity / VDI user before compression) Linked Clones (Hypervisor based clones - Requires 4 GB of thin capacity / VDI user) For each configuration run, the results are reported. Tables 3 and 4 below show the number of users supported (as defined in Appendix A). VDI Mode IOmark- VDI Standard Worker Tested Logical Capacity Total Price Price / User Linked Clone 4,096 18.25 TB $752,000.00 $183.59 Fully Provisioned 2,816 26.0 TB $752,000.00 $267.05 Table 3: IOmark- VDI Summary for Standard Worker The Standard Worker workload is measured during a steady- state period during the VDI workload. The measurement period discards the startup and end portions of the workload and measures a 30- minute window during the middle of a 60- minute workload. The response time summary is shown below in Table 4, with further details shown in Figures 3 and 4. VDI Mode Test RAID Level Average Read Resp. Time Average Write Resp. Time Average Response Time / VDI User Linked Clone RAID 5 2.11 ms 1.59 ms 1.82 ms Fully Provisioned RAID 5 1.97 ms 2.75 ms 2.34 ms Table 4: IOmark- VDI Workload Results for Standard Worker As shown above in Table 4, the 4,096 Linked Clone users had an average response time of 1.82 ms, and the 2,816 Fully Provisioned users had an average response time of 2.34 ms. both of which were lower (better) than the required response time. IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

6 IOmark- VDI Test Report Tested Configuration Details Connectivity, configuration and pricing information for the system under test are provided. Hypervisor Configuration for IOmark- VDI Workload Detailed hypervisor configuration parameters for the system under test, including connectivity are provided below in Table 5. Storage System Parameter Value Hypervisor VMware ESXi vsphere Number of interfaces to the storage system: 4 @ 16 Gb FC / Controller (8 total) Host Connectivity to the storage system: 4 @ 16Gb FC Hypervisor storage protocol used: FCP (SCSI over FC) Hypervisor version: VMware ESXi 5.5 U2 Thin provisioning: Not utilized in VMFS Hypervisor Storage Access: VMFS datastore Datastore Filesystem: VMFS 5.6 1 MB block size VAAI: VAAI supported SATP: VMW_SATP_ALUA PSP: VMW_PSP_RR (Round Robin) Total capacity of system allocated to IOmark- VDI: 26.0 TB (Actual used w/ thin provisioning) Table 5: Hypervisor Configuration Parameters IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

Storage Configuration for IOmark- VDI Workload IOmark- VDI Test Report 7 A total of 64 SCSI logical units (LUNs) were utilized on the IBM FlashSystem V9000 VMFS datastore type, with VMFS 5 chosen Each virtual machine was allocated using thin provisioning as VMware datastore type Storage System Parameter Value Storage System firmware IBM V9000 firmware version 7.5.1 High Availability Access to all LUNs Yes (active / active) Total raw capacity of system under test (SUT) 34.8 TB Total usable capacity of system under test (SUT) 26.0 TB Thin provisioning: Yes RAID Level(s) V9000 default - RAID 5 (multi- level chip R5) Total Cache Capacity: 128 GB (dual V9000 controllers R/W cache) Read Cache: Dynamic Read Ahead Write Cache: Dynamic Write Back VAAI Features Enabled: Yes - Block Zero Yes - Full Copy Yes - HW Locking Yes - NAS Clone N/A - NAS Reserve N/A Automated tiering within the storage system: No - All flash storage media Deduplication or compression of data: No Storage system clones / writeable snapshots: No Type of storage system clone: No Storage Media Utilized: - - SSD s 12 x 2.9 TB flash module = 34.8 TB - 15K RPM NA - 10K RPM NA - 7.2K RPM NA Table 6: Storage System Configuration Parameters IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

8 IOmark- VDI Test Report Configuration Diagram The logical data layout of the test configuration is shown below in Figure 1. VDI Workloads 32 / LUN = 64 LUNs @ 125 GB 26.0%TB%Pool% %Available%Capacity% Figure 1: Logical System Configuration IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

Connectivity IOmark- VDI Test Report 9 The storage connectivity was 16 Gb Fibre Channel. Each V9000 controller utilized 8 connections to the Brocade FC switch, and the V9000 storage module also used 8 FC connections, for a total of 24 @ 16 Gb FC connections for the storage. Not shown was an additional 4 @ 16 GB FC host connections. A diagram is shown below in Figure 2. Brocade+6500+16+Gb+FC+ Switch++ 24+@+16+Gb+FC+V9000+ connec?ons+ FlashSystem+V9000+ ControllerD1+ FlashSystem+Storage+ Module+ FlashSystem+V9000+ ControllerD2+ Figure 2: Physical System Connectivity IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

10 IOmark- VDI Test Report Tested Configuration Pricing Item Description Qty. List Price 1 IBM V9000, w/ 26 TB usable capacity 1 $752,000 Total List Price HW + 3 year service & support $752,000 Table 7: IOmark- VDI Price Information IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

IOmark- VDI Test Report 11 Detailed Results IOmark- VDI performance results are measured against all VDI system workloads. The average storage response times for all VDI applications are shown below in Figure 3, plotted as a Cumulative Distribution Function (CDF) for results. The CDF is a measure of statistical probability, and indicates the probability that a response time is less than a specific value. CumulaZve Response Times 120.0% Percentage of Values 100.0% 80.0% 60.0% 40.0% 20.0% V9000 0.0% 2 5 10 20 30 40 60 80 100 Response Time in ms. Figure 3: Response Time Results - V9000 Fully Provisioned As shown above in Figure 3 for 2,816 fully provisioned standard users, the system performance exceeded the requirements, indicating response times were lower than required (lower times are better). The primary response time of interest is: 99.9% of response times were less than 30 ms Also of interest is the fact that 99.9% of response times were less than 5 ms IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

12 IOmark- VDI Test Report CumulaZve Response Times 120.0% Percentage of Values 100.0% 80.0% 60.0% 40.0% 20.0% V9000 Compre ssed 0.0% 2 5 10 20 30 40 60 80 100 Response Time in ms. Figure 4: Response Time Results - V9000 Linked Clone Users As shown above in Figure 4 for 4,096 linked clone standard users, the system performance exceeded the requirements, indicating response times were lower than required (lower times are better). The primary response time of interest is: 99.9% of values were less than 30 ms Also of interest is the fact that 99.9% of response times were less than 5 ms. IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

IOmark- VDI Test Report 13 Appendix A - IOmark- VDI Overview The ability to recreate a known workload is important for comparing a system against potential alternatives. Establishing a reference or benchmark workload enables system vendors as well as resellers and IT users to compare several systems utilizing a known workload. Specifically, the IOmark- VDI benchmark recreates a storage workload that typically occurs in virtual desktop infrastructure environments. The workload is non- synthetic and recreates several applications that are commonly found in virtualized server environments. Why the Need for IOmark- VDI Currently, several application generators have been developed that are able to generate VDI workloads. However, there is no standard reference configuration, with the primary focus is on the server infrastructure. There are no existing benchmark workloads focusing on storage and storage system performance while running VDI applications. By establishing a set of standard applications and capturing their I/O streams, it is possible to recreate application based storage workloads for these complex environments. IOmark- VDI is designed utilizing these concepts, and as such is the first benchmark designed to accurately generate application workloads for storage systems, enabling direct comparison of storage system configurations and their ability to support a specific number of applications. How IOmark- VDI Operates IOmark- VDI uses the concept of workload replay. I/O streams are captured from actual running applications and then replayed so that the exact sequence and I/O commands are issued. This allows the creation of a workload that is indistinguishable from an actual workload to the system under test, while being reproducible and requiring fewer resources. Additionally, the test environment is less expensive, easier and faster to create since actual applications are not required. Because CPU and memory are not consumed running applications, a much higher I/O workload may be generated with a set of server resources than is possible using native applications. This ratio is typically 10:1, but may vary. In order to scale up the workload on a storage system, additional VDI workloads may be added to the same, or to other physical hosts. The only limitation to the scale of the test is the physical infrastructure supporting the workload. Sufficient, CPU, memory and I/O capabilities must be available to run additional workload sets. Unlike artificial workload generation tools, IOmark- VDI recreates accurate read vs. write and random vs. sequential I/O requests. Another benefit of IOmark- VDI is the fact that it creates accurate access patterns, thus enabling storage cache algorithms to work properly. Finally, IOmark- VDI maintains an accurate ratio of performance to capacity as workloads are scaled, ensuring that storage performance is measured with respect to storage capacity accurately. As a result, IOmark- VDI maintains an accurate ratio of I/O to capacity, producing results applicable to IT users. IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

14 IOmark- VDI Test Report Benchmark Application Workload Set VDI Workload 1. View steady state operation a. Heavy Worker Profile Average / VDI User i. 12.52 iops. / User ii. 1.06 MBps / User b. Standard Worker Profile Average / VDI User i. 6.26 iops. / User ii. 0.53 MBps / User 2. Benchmark Criteria: 70% of I/O response times must not exceed 30ms All storage utilized must reside on/within the storage system under test VDI Benchmark Parameters Operating System disk size is 20 GB (thinly provisioned) All user sessions were running Windows 7 as their guest OS No user data disk utilized VMware Linked clones may be utilized (as noted) Storage linked clones may be utilized (as noted) Heavy Profile: o The workload is non synthetic, actual I/O patterns are issued based on application capture o The size of I/O s is variable, ranging from 512, up to 2 MB transfers based on application Standard User Profile: o The workload is non synthetic, actual I/O patterns are issued as captured o Rates are 50% of Heavy user profile o The size of I/O s is variable, ranging from 512, up to 2 MB transfers VDI Workload Generation The workload generator used to generate the VDI workload was VMware View Planner. This application workload generator controlled running the 8 listed applications above, in a Windows 7 64 bit OS environment, running as a guest VM in a hypervisor environment. IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015

IOmark- VDI Test Report 15 VDI Workload Details The specific applications comprising a VDI workload set are detailed below in Table 7. Application Guest OS (Microsoft Win 7 64bit) MS Office (Word, Excel, PowerPoint and Outlook) MS Internet Explorer Adobe Acrobat Reader Windows Media Server Windows 7 zip Total VDI Guest Environment Storage Capacity / Instance 20 GB N/A N/A N/A N/A N/A Total = 20 GB Table 8: IOmark- VDI Guest Application Overview The total capacity required for each set of applications is approximately 20 GB of logical capacity. Each additional workload set requires an additional 20 GB of logical capacity. The capacity required for linked clone users is 4 GB which is the capacity after data reduction, and the capacity required for fully provisioned users is 14 GB without data reduction, or 8 GB with compression. Understanding Results IOmark- VDI produces results indicating the response time of a storage system given a particular workload. Based on established criteria, these results indicate how many VDI sessions are supported by a specific storage configuration with a maximum allowed response time. The report is audited for accuracy and issued by Evaluator Group, Inc., an independent storage analyst firm. Benchmark Criteria IOmark has established the benchmark criteria for the IOmark- VDI workload. The performance requirements are established as follows: For all application workloads: o 70% of response times for I/O s must not exceed 30ms o All storage must reside on the storage system under test o The replay time must complete within 1 hour and 15 seconds for each 1 hour workload IOmark- VDI Test Identifier: VDI- 151205- a Report Date: 5, December 2015

16 IOmark- VDI Test Report More Information about IOmark- VDI For more information about the IOmark benchmark, a theory of operations guide, published results and more, visit the official website at http://www.iomark.org. Some content is restricted to registered users, so please register on the site to obtain all available information and the latest results. About Evaluator Group Evaluator Group Inc. is a technology research and advisory company covering Information Management, Storage and Systems. Executives and IT Managers use us daily to make informed decisions to architect and purchase systems supporting their digital data. We get beyond the technology landscape by defining requirements and knowing the products in- depth along with the intricacies that dictate long- term successful strategies. Web: www.evaluatorgroup.com, Twitter: @evaluator_group IOmark- VDI: Test Identifier: VDI- 151205- a Report Date: 5, December 2015