DICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number:

Similar documents
DICOM Conformance Statement August 23, 2010 Version 1.0 ImageWorks Internal document number:

Copyright FUJIFILM Corporation, Japan. August, th Edition 897N100760F

REGIUS CONSOLE CS-2. Revision History. Date Version Description 02/08/2004 Ver This Conformance Statement applies to DICOM3.0 (2000 version).

DICOM CONFORMANCE STATEMENT

This conformance statement specifies the compliance of EponaTech s Metron-DVM to the DICOM standard Version 3.0.

DICOM Conformance Statement

nstream Version 3.1 DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT

DICOM Conformance Statement for GALILEI. Software Version V6.0

DICOM Conformance Statement

Kodak Point of Care CR systems. DICOM Conformance Statement

Artwork consists of sixty-five (65) 8 ½ inch x 11 inch pages.

DICOM CONFORMANCE STATEMENT FOR DIAGNOSTIC ULTRASOUND SYSTEM MODEL SSA-640A V5.0

KARL STORZ OR1 FUSION V1.3.1 DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR VANTAGE-GALAN TM VERSION V5.0

DICOM Conformance Statement

DICOM. Conformance Statement For VINNO Medical Ultrasound System Revision 2.0. Copyright 2012 by VINNO Technology (Suzhou) Co., Ltd.

Sonovision DICOM Conformance Statement

Fluoroscan InSight V5.0.6 DICOM Conformance Statement

MediaWorkStation. MWS DICOM Push Interface. DICOM Conformance Statement. Version 2.0. English

DICOM Conformance Statement

DICOM Conformance Statement

Hologic Physician s Viewer 5.0 DICOM Conformance Statement

KARL STORZ AIDA V1.3.1 DICOM Conformance Statement PRODUCT INFO OR1 OR /2017/PI-E 1/32

Artwork consists of twenty three (23) 8½ x 11 inch pages.

DICOM 3.0 Conformance Statement for PlatinumOne Systems

Topcon Medical Systems

DICOM Conformance Statement for PenFetch

DICOM Conformance Statement

SonoWin Picture Archiving System

DICOM Conformance Statement

DICOM Conformance Statement for FLEXAVISION HB/FD

Technical Publication. DICOM Conformance Statement. BrainSUITE NET 1.5. Document Revision 1. March 5, Copyright BrainLAB AG

DICOM Conformance Statement for IMAGEnet 5

Uscan. DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT. BrainLAB PatXfer 5

SCORE 3D Workstation DICOM CONFORMANCE STATEMENT

Printlink III-ID/IV. Revision History. Date Version Description 20/08/2004 Ver First edition

Technical Publications

DICOM Conformance Statement. CT AV Series Product Line. Document Number February 1997

DICOM Conformance Statement * /02* /02 MADE IN GERMANY

DICOM CONFORMANCE STATEMENT FOR CANON DIGITAL RADIOGRAPHY SYSTEM. MODEL DRAD series / MRAD series

DICOM Conformance Statement for Selenia Dimensions Acquisition Workstation Software Version 1.8 Part Number MAN Revision 002

Villa Sistemi Medicali DRF 4343

AGFA HEALTHCARE DICOM Conformance Statement

DICOM Conformance Statement, Biim Ultrasound App Version 1

DICOM Conformance Statement

Retinal imaging control software NM. DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL DRAD-3000A, DRAD-3000E

Technical Publications

CoActiv, LLC CoActiv Medical Business Solutions EXAM-PACS Conformance Statement

Lumify 1.8.x DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM

Technical Publications

DICOM Conformance Statement. Forum

DICOM Conformance Statement for DR-200/DRU-200

DICOM CONFORMANCE STATEMENT STORAGE SCU FOR TOSHIBA DIGITAL FLUOROGRAPHY SYSTEM MODEL DFP-2000A. with XIDF-053A or XIDF-056A (MIIXR0001EAB)

DICOM Conformance Statement AIDA HD Connect

Galileo CAD. DICOM Conformance Statement Version Copyright by ARCADIA LAB srl

DICOM Conformance Statement

Dx Server for Windows NT DICOM 3.0 Conformance Statement

Technical Publications

Surgimap. DICOM Conformance Statement. Revision 2.0

Dx Server for Windows NT DICOM 3.0 Conformance Statement

DBSWIN DICOM Conformance Statement. DBSWIN DD-DICOM Interface. DICOM Conformance Statement V2.1

DICOM Conformance Statement FORUM

DICOM Conformance Statement

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM. Infinix Celeve-i series / Infinix-i series Model XIDF-3DP801 AND ANGIO WORKSTATION

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL ADR-1000A /R2 (MIIXR0003EAE)

DAR-9400f / DAR-9500f DICOM Conformance Statement Revision J

DICOM Conformance Statement

DICOM Conformance Statement RadWorks 2.1 Product Line

Table of contents REVISION HISTORY INTRODUCTION DICOM CONFORMANCE STATEMENT IMPLEMENTATION MODEL

The CT Synergy (V3.1/V3.2/V3.3/V3.4/V3.5) Conformance Statement

DICOM. Conformance Statement. HD3 Release Rev A. Koninklijke Philips Electronics N.V All rights are reserved.

Whole Body X-ray CT System Supria. DICOM Conformance Statement

Technical Publication. DICOM Conformance Statement. iplan 3.0. Document Revision 1. November 17, Copyright BrainLAB AG

JiveX Enterprise PACS Solutions. JiveX DICOM Worklist Broker Conformance Statement - DICOM. Version: As of

DICOM 3.0 Conformance Statement DXIMAGE RIS

Technical Publications

SonoWin Picture Archiving System

HS40 Ultrasound System

DICOM Conformance Statement. CR-VW 674 for DICOM Storage DICOM Print DICOM MWM DICOM MPPS DICOM Media Storage

DICOM Conformance Statement RadWorks 4.0 Product Line

OASIS V4.0 DICOM Conformance Statement Rev. 3

DICOM CONFORMANCE STATEMENT FOR TOSHIBA DIGITAL RADIOGRAPHY SYSTEM MODEL HDR-08A

DICOM CONFORMANCE STATEMENT FOR TOSHIBA SUGICAL C-ARM SYSTEM. SXT series. Model SXT-2000A ( CXVIEW )

DICOM. Conformance Statement. Panorama Release 6. Panorama 0.6T Panorama 0.23T Panorama 0.23T I/T Panorama 0.23T R/T

DICOM CONFORMANCE STATEMENT FOR Diagnostic Ultrasound System

efx Software DICONDE Conformance Statement

Technical Publications

MediPlus TM PACS&RIS Version 2.6

Sep, th Edition 897N101668H

Echology Server. DICOM Conformance Statement Volume 1. <Storage and Query/Retrieve Server> Revision 1.0 Software Version 5.

CMT MEDICAL TECHNOLOGIES

GE Healthcare. Technical Publications. ConnectR Plus Version 5.0 DICOM CONFORMANCE STATEMENT. GE Healthcare IT. Direction DOC Revision 0.

DICOM Conformance Statement. DSI Release 4.4. Document Number June Copyright Philips Medical Systems Nederland B.V.

X-Porte DICOM Conformance Statement

Technical Publications

DICOM Conformance Statement FORUM

Transcription:

DICOM Conformance Statement June 24, 2011 Version 0.4 ImageWorks Internal document number: 0000062015 ImageWorks 250 Clearbrook Road, Suite 240 Elmsford, NY 10523 (914) 592-6100 www.imageworkscorporation.com 1

Revision History Version Date Author/revised by: Description 1.0 Draft 04/11/2008 Lance C Paulose Initial draft of the Dicom conformance statement for the ViewAll software. 0.0 04/21/2008 Lance C Paulose Updated the document with review comments. 0.1 07/09/2008 Lance C Paulose Updated the SOP Class Information and SOP Specific Conformance Storage SCU attributes. 0.2 07/23/2008 Lance C Paulose Updated the Implementation Class UID value of dcm4che-1.4.11 0.3 07/10/2009 Elena dasilva Feroe Added the Modality Worklist SCU and DICOM Receiver. 0.4 06/24/2011 J Johnson Update Company Name and Logos. Replaced ViewAll Vet with ViewAll. Added Verification C-Echo. Updated Worklist functionality 2

Contents 1 INTRODUCTION... 5 1.1 Intended Audience... 5 1.2 Purpose of This Document... 5 1.3 Sources for This Document... 5 2 IMPLEMENTATION MODEL... 6 2.1 Application Data Flow Diagram... 6 2.2 Functional Definitions of AE s... 7 2.2.1 Storage SCU... 7 2.2.2 Modality Worklist SCU... 7 2.2.3 Verification (Echo) SCU... 8 3 AE SPECIFICATIONS... 8 3.1 Supported Services... 8 3.1.1.1 General... 8 3.1.1.2 Number of Associations... 8 3.1.1.3 Asynchronous Nature... 8 3.1.1.4 Implementation Identifying Information... 8 3.1.2.1 Presentation Context Table... 9 3.1.2.2 Called/Calling AE-Titles... 9 3.1.2.3 Association Initiation by Real World Activity... 9 3.1.3.1 SOP Specific Conformance Storage SCU... 10 3.1.3.2 SOP Specific Conformance Modality Worklist SCU... 12 4 COMMUNICATION PROFILES... 13 4.1 Supported Communication Stacks... 13 3

4.2 TCP/IP Stack... 13 5 EXTENSIONS / SPECIALIZATIONS / PRIVATIZATIONS... 13 5.1 Standard Extended/Specialized/Private SOPs... 13 5.2 Private Transfer Syntaxes... 13 6 CONFIGURATION... 13 6.1 AE Title/Presentation Address Mapping... 13 6.2 Configuration Parameters... 14 4

1 INTRODUCTION 1.1 Intended Audience The reader of this document is involved with system integration and/or software design. We assume that the reader is familiar with the terminology and concepts that are used in the DICOM 3.0 standard. Readers not familiar with DICOM 3.0 terminology should first read the appropriate parts of the DICOM standard itself, prior to reading this conformance statement. 1.2 Purpose of This Document This document is the DICOM Conformance Statement for the DICOM services of ViewAll as an acquisition modality. Its purpose is to specify compliance with the DICOM standard on the following ViewAll supported service classes: Digital X-Ray Image Storage For Presentation Service Class as an SCU DICOM Receiver Modality Worklist Service Class as an SCU 1.3 Sources for This Document Digital Imaging and Communications in Medicine (DICOM) V3.0, ACR-NEMA 5

2 IMPLEMENTATION MODEL The ViewAll is a point-to-point image acquisition device for image transmission, storage between DICOM modalities and the DICOM network. Basic Worklist Management service is used to get patient demographic data from an existing server. The DICOM Receiver allows ViewAll to store images that are sent from other Application Entities (AE). 2.1 Application Data Flow Diagram The Basic and Specific Application models for this device are shown in the following illustrations: DICOM Standard Interface Send Object from Database DICOM Sender DICOM Receiver Storage SCP Store Object in Database DICOM Receiver DICOM Sender Storage SCU Figure 2.1 Application Data Flow Diagram The DICOM Receiver is a Microsoft Windows (Windows 7, Vista and XP) application for the transfer of DICOM images. It is executed on OS startup as a separate application process for all Windows operating systems. 6

2.2 Functional Definitions of AE s 2.2.1 Storage SCU ViewAll Store SCU is implemented as an application entity for transmitting DX images. The DICOM Storage Service of DX image is used to send demographic information and pixel data to an external image manager. Initiate a DICOM association to send the SC IOD Issue a C-STORE service Send the IOD with the pixel data processed as defined in the configuration of the external user Access the local database to update the exam information. Close the Association The DICOM Receiver waits for other Application Entities (AEs) to initiate DICOM storage requests. Then it informs the user that a Store request was received. The user must acknowledge and approve the Store, in order for the patient to be added and the images to be saved in the ViewAll image management database. 2.2.2 Modality Worklist SCU ViewAll Modality Worklist SCU is implemented as an application entity for retrieving the Modality Worklist from any DICOM Server SCP. The DICOM C-Find Service of MWL is used to request the scheduled procedure steps. Initiate a DICOM association to request the Modality Worklist Issue a C-FIND request with the requested attributes IOD Send the IOD to the DICOM Server SCP Access the local database to add or update the scheduled objects Close the Association 7

2.2.3 Verification (Echo) SCU ViewAll will automatically respond to a Verification request when the DICOM Receiver is enabled. Verification requests from ViewAll to other DICOM AE are initiated manually with user dialog indicating success or failure. 3 AE SPECIFICATIONS 3.1 Supported Services ViewAll provides Standard Conformance to the DICOM V3.0 SOP Classes as an SCU. SOP Class Name SOP Class UID Verification SOP Class 1.2.840.10008.1.1 Media Storage SOP Class 1.2.840.10008.5.1.4.1.1.1.1 Modality Worklist Information Model - FIND 1.2.840.10008.5.1.4.31 Table 3.1 SOP Classes Supported as an SCU 3.1.1 Association Establishment Policies 3.1.1.1 General Before any SOP Classes can be exchanged between the ViewAll (SCU) and the SCP, an association stage takes place to negotiate the capabilities of the SCU and SCP. 3.1.1.2 Number of Associations The ViewAll opens only one association at a time. 3.1.1.3 Asynchronous Nature Asynchronous mode is not supported. All operations will be performed synchronously. 3.1.1.4 Implementation Identifying Information The ViewAll SCU will respond with the following implementation identifying parameters: Implementation Class UID Implementation Version Name 1.2.40.0.13.1.1 dcm4che-1.4.11 8

3.1.2 Association Initiation Policy ViewAll attempts to initiate a new association for every service. 3.1.2.1 Presentation Context Table Presentation Context Table - Proposed Abstract Syntax Transfer Syntax Role SOP Class Name SOP Class UID Transfer Syntax Name Verification 1.2.840.10008.1.1 Explicit VR Little Endian Digital X-ray Presentation Modality Worklist Information Model 1.2.840.10008.5.1.4. 1.1.1.1 1.2.840.10008.5.1.4. 31 Explicit VR Little Endian Explicit VR Little Endian Table 3.2 Presentation Context List UID 1.2.840.10008.1.2.1 SCU 1.2.840.10008.1.2.1 SCU 1.2.840.10008.1.2.1 SCU 3.1.2.2 Called/Calling AE-Titles This can be modified during configuration via a configuration setting. The calling AE Title is case sensitive. The calling AE- Title is VIEWALLVET and can be modified by the user. 3.1.2.3 Association Initiation by Real World Activity 3.1.2.3.1 Storage The ViewAll Digital X-ray Presentation AE initiates a new association for each set of images it needs to transfer. The status of the image transfer is displayed by the status bar available at the bottom left corner of the software. If the SCP AE rejects the Association, then the ViewAll will explicitly notify the user. When the DICOM Receiver receives images to be stored, it prompts the user to select the appropriate patient, based on the Tag information found in the image. Only then will it proceed with adding the patient and images to the database. 9

3.1.2.3.2 Modality Worklist The ViewAll Worklist SCU AE initiates a separate Association for each Worklist of items to be obtained. If the SCP AE rejects the Association, then ViewAll issues a warning message. 3.1.3 SOP Specific Conformance 3.1.3.1 SOP Specific Conformance Storage SCU 3.1.3.1.1 Supported attributes Attribute Name Tag VR VM Remark Patient s Name (0010,0010) PN 1 Configurable Patient ID (0010,0020) LO 1 Configurable Patient s Sex (0010, 0040) LO 1 Configurable Patient s Sex Neutered (0010, 2203) CS 1 Configurable Patient s Birth Date (0010, 0030) DA 1 Configurable Patient s Weight (0010, 1030) DS 1 Configurable Patient s Size (0010, 1020) DS 1 Configurable Patient s Telephone Numbers (0010,2154) SH 1-n Configurable Patient s Comment (0010, 4000) LT 1 Configurable Patient Species Description (0010, 2201) LO 1 Other Patient s IDs (0010, 1000) LO 1-n Institution Name (0008, 0080) LO 1 Configurable Institution Address (0008, 0081) ST 1 Configurable Performing Physician Name (0008,1050) PN 1-n Configurable Responsible Person (0010,2297) PN 1 Configurable Responsible Person Role (0010, 2298) CS 1 Configurable Responsible Organization (0010, 2299) LO 1 Configurable Breed Registration Number (0010, 2295) LO 1 Configurable Issuer Of Patient ID (0010, 0021) LO 1 Type Of Patient ID (0010, 0022) CS 1 Study Date (0008, 0020) DA 1 Study ID (0020, 0010) SH 1 10

Study Instance UID (0020, 000D) UI 1 Image Type (0008, 0008) CS 1-n Acquisition Date (0008, 0022) DA 1 Modality (0008, 0060) CS 1 Accession Number (0008, 0050) SH 1 Output Power (0018, 5000) SH 1-n X-Ray Tube Current in ma (0018, 9330) FD 1 Configurable Exposure Time (0018, 1150) IS 1 Configurable Image Comments (0020, 4000) LT 1 Configurable Manufacturer (0080, 0070) LO 1 Device Serial Number (0018, 1000) LO 1 Rows (0028, 0010) US 1 Columns (0028, 0011) US 1 Samples Per Pixel (0028, 0002) US 1 Bits Allocated (0028, 0100) US 1 Bits Stored (0028,0101) US 1 Pixel Representation (0028, 0103) US 1 High Bit (0028, 0102) US 1 Image Type (0008,0008) CS 1-n Burned In Annotation (0028, 0301) CS 1 Pixel Intensity Relationship (0028, 1040) CS 1 Pixel Intensity Relationship Sign (0028, 1041) SS 1 Rescale Intercept (0028, 1052) DS 1 Rescale Slope (0028, 1053) DS 1 Rescale Type (0028, 1054) LO 1 Lossy Image Compression (0028, 2110) CS 1 Detector Type (0018,7004) CS 1 Device Description (0050,0020) LO Configurable Imager Pixel Spacing (0018,1164) DS 2 Presentation Intent Type (0008,0068) CS 1 Photometric Interpretation (0028,0004) CS 1 11

Presentation LUT Shape (2050,0010) CS 1 Anatomic Region Sequence (0008, 2218) SQ 1 Acquisition Context Sequence (0040, 0555) SQ 1 Transfer Syntax UID (0020, 0010) UI 1 Source Application Entity Title (0020, 0016) AE 1 SOP Class UID (0008, 0016) UI 1 Media Storage SOP Class UID (0002, 0002) UI 1 Instance Creation Time (0008, 0013) TM 1 Instance Creation Date (0008, 0012) DA 1 SOP Instance UID (0008, 0018) UI 1 Study Instance UID (0020, 000D) UI 1 Specific Character Set (0008, 0005) CS 1-n Window Width (0028, 1051) DS 1-n Window Center (0028, 1050) DS 1-n Patient Orientation (0020, 0020) CS 2 Configurable Image Laterality (0020,0062) CS 1 Configurable Table 3.3 C-Store SCU Standard DICOM Attributes 3.1.3.2 SOP Specific Conformance Modality Worklist SCU 3.1.3.2.1 Supported attributes Attribute Name Tag VR VM Remark Modality (0008,0060) CS 1 Configurable Study Date (0008, 0020) DA 1 Configurable Table 3.4 Modality Worklist Information Model Attributes 3.1.4 Association Acceptance Policy Not applicable, because the VIEWALL (SCU) cannot accept an Association. 12

4 COMMUNICATION PROFILES 4.1 Supported Communication Stacks DICOM Upper Layer (PS 3.8) is supported using TCP/IP. 4.2 TCP/IP Stack The ViewAll (SCU) uses TCP/IP for the protocol stacks. 5 EXTENSIONS / SPECIALIZATIONS / PRIVATIZATIONS 5.1 Standard Extended/Specialized/Private SOPs None Supported 5.2 Private Transfer Syntaxes None Supported 6 CONFIGURATION See ViewAll User Manual for configuration. 6.1 AE Title/Presentation Address Mapping The Local AE Title is configured as VIEWALLVET. The title could be viewed in the Tools-> DICOM Settings menu. The Local AE Title of the Receiver is configured as VAVSER. The title could be viewed in the Tools-> DICOM Settings menu. 13

6.2 Configuration Parameters The following fields are configurable for this Store SCU/SCP and Query and Retrieve SCU: Name of the Server DICOM Server Address (Remote IP Address) Remote AE Title DICOM Server Port (Remote TCP Port Number) Local AE Title Retry Wait Time (ms) The following fields are configurable for this Receiver: DICOM Server Port (Local TCP Port Number) Local AE Title The Following fields are configurable for this Modality Worklist SCU: DICOM Server Address (Remote IP Address) Remote AE Title DICOM Server Port (Remote TCP Port Number) Date Modality (DX, DR, CR, ALL) 14