Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems

Similar documents
Cable Routing Procedures for Dell PowerEdge R630 Systems

Cable Routing Procedures for Dell PowerEdge T710 Systems

Cable Routing Procedures for Dell PowerEdge FX2/FX2s Systems

Mounting and Cable Routing Procedures for Dell Digital KVM s (1082DS, 2162DS, 4322DS)

MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas

Using Dell Repository Manager to Find Newer Updates from the Dell Online Repository

Vertiv Local Rack Access 18.5" LED LCD Console

2U, 4U, and 7U Systems

Dell EMC Enterprise Systems Rail Sizing and Rack Compatibility Matrix

Rack Installation Instructions

Install the Cisco SNS 3415 and Cisco SNS 3495 Hardware Appliances, page 1

Dell OpenManage Cluster Configurator on Dell PowerEdge VRTX

DellEMC TM Enterprise Systems Rail Sizing and Rack Compatibility Matrix

Lifecycle Controller Part Replacement

Dell Server Migration Utility (SMU)

Configuring Alert Actions in OpenManage Essentials

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA

Wall Mounted Building Entrance Enclosure Instructions

Using Dell Repository Manager to Create a Deployment Media (Bootable ISO) to Perform Systems Updates

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Dell IT Assistant Migration To OpenManage Essentials

Lifecycle Controller Part Replacement

G12/G12x USER S MANUAL

Datasheet. Fiber Optic Modular Patch Panel Features

Accelerating storage performance in the PowerEdge FX2 converged architecture modular chassis

Using Dell Repository Manager to Update Your Local Repository

Dell XPS 14z Owner s Manual

Dell PowerEdge R720xd with PERC H710P: A Balanced Configuration for Microsoft Exchange 2010 Solutions

Rack Installation Instructions

Cable Dressing and Wiring Workmanship Standard

APPLYING PROPER CABLE MANAGEMENT IN IT RACKS. A Guide For Planning, Deployment And Growth

The University of Texas at Austin July 30, 2014 SECTION COMMUNICATIONS TERMINATION BLOCKS AND PATCH PANELS

Assembly Instructions

HD Flex Zero RU Cassette Holder and Bracket

Dell Inspiron N5110 Service Manual

Rack Mount Cabinet with Fiber Mgmt System, accepts up to 3 Adapter Plates. Rack Mount Cabinet with Fiber Mgmt System, accepts up to 6 Adapter Plates

Rack Selection Guide for NetShelter SX

Understanding Discovery and Inventory of Dell Devices

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

CLOSET CONNECTOR HOUSING

CMA Installation Guide

Dell OptiPlex SFF AIO Stand. User s Guide. Model: IKAIO-01 1 /13

and Network Interface Modules Installation Instructions

vstart 50 VMware vsphere Solution Specification

Business Intelligence on Dell Quickstart Data Warehouse Appliance Using Toad Business Intelligence Suite

Installation Guide. HP J2437A 4-Port Token Ring Interface for the HP Router 650

Pretium Rack-mountable 1U Housing Hardware

Instructions for SVC-KIT-0020

HPE Performance Optimized Datacenter (POD) Networking Guide

IBM. Rack Installation Instructions

Rack Installation Instructions

Netfinity White Paper Netfinity Technology Center

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

InfraStruXure Central Standard/Enterprise Installation/Start-Up Service Procedure

FL1000 Wall-Mount Box Installation and Operation Guide

7403 K321. Display Wall Mount. Kit Instructions. Issue A

AMP NETCONNECT* Gen II Vertical Storage Area Management (SAM) System

Dell OpenManage Power Center s Power Policies for 12 th -Generation Servers

DNS-2608 Enterprise JBOD Enclosure User Manual

Replacing the Billboard Router

RACKS AND CABLE MANAGEMENT

Replacement Instructions. Backplane PCA for the HP Router 650

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

Fiber Management Tray (FMT) User Manual

Dell XPS L702X Service Manual

Introduction to the CRS Back-to-Back System

A Dell Technical White Paper Dell Virtualization Solutions Engineering

Internal tray pulls out towards the user, providing room to manage the fiber cable behind the fiber adapter panels.

NetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels

Solutions Guide for Cisco UCS B and C Series Servers

Cisco TelePresence VX Clinical Assistant TM

3 Angled Connector Housing (MC) Installation

Routing Power and Signal Cables

OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets

Storage Consolidation with the Dell PowerVault MD3000i iscsi Storage

Cost and Performance benefits of Dell Compellent Automated Tiered Storage for Oracle OLAP Workloads

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

IBM Systems. Quick start guide for IBM System p5 505 ( )

Ordering Guide for FIST Blue Label Racks (FIST-GR3)

Thank you for purchasing this Factory Service Manual CD/DVD from servicemanuals4u.com.

Get on-premise private cloud with enterprise managed services.

Agilent N2916B 6000 and 5000 Series Oscilloscope Rack Mount Kit

Internal Cabling Guide for the HP Smart Array 6400 Series Controller on an HP Integrity Server rx7620

Microsoft SQL Server 2012 Fast Track Reference Architecture Using PowerEdge R720 and Compellent SC8000

Dell Storage with Microsoft Storage Spaces Configurations and Solution IDs

Panzura Freedom Filer Installation Guide

M1034W Engineering Workstation

Rack Installation Instructions

Compaq Ultra-Dense Server Deployment in Telecommunications (Telco) Racks

E1135C PDU and Pod Upgrade Procedure

Dell PowerEdge C410x. Technical Guide

1. Unpacking the System

Replacing a 3.5-inch disk drive

INFOBrief. Dell PowerVault 114T DAT72, DLT VS160, SDLT 320, LTO-1, and LTO-2 Tape Rack Enclosure. Key Points

APC Open Frame Rack Networking Solutions

Enhancing Oracle VM Business Continuity Using Dell Compellent Live Volume

Analyzing Patent Data in Dell Quickstart Data Warehouse Appliance Using Toad Business Intelligence Suite

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

TDM To MiniMech conversion ProceDure

Transcription:

Cable Routing Procedures for Dell PowerEdge T320 & T420 Systems This Dell Technical White Paper explains the best practices for routing and securing the cables exiting the back of the T320 & T420 systems. Greg Henderson and Jose L. Flores Data Center Infrastructure Engineering May 2012

This document is for informational purposes only and may contain typographical errors and technical inaccuracies. The content is provided as is, without express or implied warranties of any kind. 2012 Dell Inc. All rights reserved. Dell and its affiliates cannot be responsible for errors or omissions in typography or photography. Dell, the Dell logo, and PowerEdge are trademarks of Dell Inc. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Dell disclaims proprietary interest in the marks and names of others. May 2012 Rev 1.0 2

Contents Introduction... 4 Section 1: Cabling a PowerEdge T320 & T420 system with a CMA... 4 1.1. Connecting the cables to the system... 4 1.2. Routing the power cables through the strain reliefs... 5 1.3. Installing the CMA... 6 Section 2: Replacing a hot swap power supply on a PowerEdge T320 & T420 system with a CMA... 8 2.1. Replacing a hot swap power supply with a left-side mounted CMA... 8 2.2. Replacing a hot swap power supply with a right-side mounted CMA... 8 Section 3: Cabling a PowerEdge T320 & T420 system without a CMA... 9 Figures Figure 1. System with cables installed... 5 Figure 2. Routing power cables through the strain reliefs on hot swap power supplies... 5 Figure 3. Routing the power cable through the strain relief on a fixed power supply... 5 Figure 4. Left-side mounted CMA installation (preferred)... 6 Figure 5. Right-side mounted CMA installation (CMA shown in service position)... 7 Figure 6. Replacing a hot swap power supply... 8 Figure 7. Cable routing without a CMA... 9 3

Introduction This white paper covers recommended cable routing procedures for the Dell PowerEdge T320 & T420 systems in the following racks: PowerEdge 2410, 4210 PowerEdge 2420, 4220, 4820 (including wide and deep versions) PowerEdge Energy Smart 4020S, 4620S If you are using the optional cable management arm (CMA), following these procedures will allow you to extend the system from the rack for service without powering down or disconnecting the cables. If you are not using the CMA, following these procedures will ensure secure attachment and strain relief of the cables behind the system. For guidelines on how to route cables within the rack, refer to the Dell Best Practices Guide for Rack Enclosure white paper. For additional details regarding potential interferences between the CMA and rear-mount power distribution units (PDUs) in Dell racks as well as general information about third party rack compatibility, refer to the Dell Enterprise Systems Rail Sizing and Rack Compatibility Matrix located at http://content.dell.com/us/en/enterprise/d/business~solutions~engineeringdocs~en/documents~rail-rack-matrix.pdf.aspx. Section 1: Cabling a PowerEdge T320 & T420 system with a CMA This section details how to cable the PowerEdge T320 & T420 systems using a CMA. If you are cabling the system without the optional CMA, refer to Section 3. Follow the instructions contained in the Rack Installation Instructions in the rail kit to install the server into the rack. Once installed, use these instructions to install the cables. All illustrations in the following sections were created using a PowerEdge T320 system. NOTE: The PowerEdge T320 & T420 systems are compatible with both the PowerEdge T610 rails and CMA and the PowerEdge T620 rails and CMA. 1.1. Connecting the cables to the system Attach the CMA tray to the back of the rails as described in the CMA Installation Instructions provided in the CMA kit. Connect all applicable cables to the rear of the system and verify that all connections are secure. See Figure 1. 4

Figure 1. System with cables installed 1.2. Routing the power cables through the strain reliefs After you have installed the tray and cables, route the power cable(s) through the strain relief(s) located on the power supply handle(s) as shown in Figures 2 & 3. Figure 2. Routing power cables through the strain reliefs on hot swap power supplies Figure 3. Routing the power cable through the strain relief on a fixed power supply 5

1.3. Installing the CMA The CMA can be installed on either the rear right or rear left side of the rails as described in the CMA Installation Instructions. Mounting the CMA on the side that is opposite of the power supplies (left-side mount) is recommended; otherwise, the CMA must be partially disconnected in order to remove the outer power supply. Refer to Section 2 for details on power supply replacement. NOTE: If you are installing fiber-optic cables in the CMA, a cable bend radius of at least 1 inch must be maintained throughout the length of the cable. It is recommended that fiber-optic cables be routed on the exterior of the cable bundle to increase the bend radius of the fiber-optic cables through the CMA. Additionally, a large amount of slack at the entrance and exit of the CMA is recommended. 1.3.1. Left-side mounting instructions 1. Install the CMA on the rear left side of the rails by attaching both CMA housings to the attachment brackets on the rails as described in the CMA Installation Instructions. 2. Route the cables through the CMA while avoiding twisting the cables. Use the hook-and-loop straps on the CMA to secure the cables. 3. If the cable bundle includes a keyboard, video, and mouse system interface pod (KVM SIP), it can be placed inside the CMA basket. 4. Once you have routed all of the cables through the CMA, dress the cable slack between the back of the system and the entrance of the CMA using the tie wraps provided in the CMA kit. 5. Clip off the excess length of material from the tie wraps. Make sure that the heads of the tie wraps are positioned so as to avoid interference with adjacent systems. Return the CMA to the closed (retracted) position. 6. Extend the system out of the rack to verify that there is sufficient slack in the cables on both ends of the CMA. See Figure 4 for an example of a completed left-side mounted CMA installation. Figure 4. Left-side mounted CMA installation (preferred) NOTE: Do not store excess cable slack inside the CMA. The cables may protrude through the CMA, thus causing binding and potentially damaging the cables. Cables entering the CMA should have a small amount of slack to avoid cable strain when the CMA is extended. KVM SIP can be placed inside the CMA basket. 6

1.3.2. Right-side mounting instructions 1. Install the CMA on the rear right side of the rails by attaching both CMA housings to the attachment brackets on the rails as described in the CMA Installation Instructions. 2. Route the cables through the CMA while avoiding twisting the cables. Use the hook-and-loop straps on the CMA to secure the cables. 3. If the cable bundle includes a KVM SIP, its length may be too short for it to be placed inside the CMA basket. Route the remainder of the cable that is beyond the SIP module through the CMA. DO NOT secure the SIP to the outside of the CMA as this may restrict the ability of the CMA to support full extension of the rails without causing damage to the SIP. 4. Once you have routed all of the cables through the CMA, dress the cable slack between the back of the system and the entrance of the CMA using the tie wraps provided in the CMA kit. 5. Clip off the excess length of material from the tie wraps. Make sure that the heads of the tie wraps are positioned so as to avoid interference with adjacent systems. Return the CMA to the closed (retracted) position. 6. Extend the system out of the rack to verify that there is sufficient slack in the cables on both ends of the CMA. See Figure 5 for an example of a completed right-side mounted CMA installation. Figure 5. Right-side mounted CMA installation (CMA shown in service position) KVM SIP placed outside the basket for right-side mounting. 7

Section 2: Replacing a hot swap power supply on a PowerEdge T320 & T420 system with a CMA 2.1. Replacing a hot swap power supply with a left-side mounted CMA 1. Swing the CMA to its service position as described in the CMA Installation Instructions provided with the CMA kit. 2. Disengage the strain relief and disconnect the power cord from the power supply. 3. Remove and replace the power supply. 4. Plug in the power cord, re-engage the strain relief, and return the CMA to the closed (retracted) position. 2.2. Replacing a hot swap power supply with a right-side mounted CMA 1. Swing the CMA to its service position as described in the CMA Installation Instructions provided with the CMA kit. 2. Disengage the strain relief and disconnect the power cord from the power supply. 3. Disconnect both CMA attachment housings from the brackets on the rails. 4. While supporting the CMA with one hand, remove and replace the power supply with the other hand as shown in Figure 6. 5. Reattach the CMA to the attachment brackets on the rails. 6. Plug in the power cord, re-engage the strain relief, and return the CMA to the closed (retracted) position. Figure 6. Replacing a hot swap power supply 8

Section 3: Cabling a PowerEdge T320 & T420 system without a CMA NOTE: The CMA for Dell PowerEdge T320 & T420 is optional. Without the CMA installed, the system must be powered down and all cables disconnected before it can be extended out of the rack. 1. Connect all applicable cables to the rear of the system and verify that all connections are secure. 2. Using the hook-and-loop straps supplied with the rail kit, bundle the cables and secure them to either the left or right CMA attachment bracket as described in the Rack Installation Instructions. See Figure 7 for an example of data cables secured to the left CMA bracket and power cables secured to the right CMA bracket (as viewed from the rear of the system). 3. It is recommended that the cables be secured to the outer brackets, but cables may be secured to the inner brackets if desired. Figure 7. Cable routing without a CMA 9