FOR CLEAN WATER AND SEWAGE WATER

Similar documents
FOR LIQUIDS AND SOLIDS

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 307. Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % / 0.

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO

LMP 308i. Separable Stainless Steel Probe Precision. Stainless Steel Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Product information. Hydrostatic. Submersible pressure transmitter VEGABAR 86 VEGABAR 87 VEGAWELL 52. Document ID: 45079

Model 675 DREXELBROOK. Shark Cage Submersible Level Transmitter DATA SHEET. Description. Features. Applications.

Product Data. Model 675 Shark Cage Submersible Level Transmitter ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

SMARTLINE RM76 Supplementary instructions

DR7100 SERIES Supplementary instructions

Capacitance level switches LS 210 LS 220

LS 6600 Technical Datasheet

Level gauges Series LS Level indicator, switch and transmitter for liquids

Operating Instructions

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids.

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

Inductive sensor with analog output BI15-M30-LI-EXI

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Variable Area Flowmeter DATASHEET

Flow measurement FlexFlow PF20S Flow sensor for industrial applications

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

Float Switches with Permanent Magnet For Vertical Installation Model RSM

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

I-LEVEL OMX 167 Hydrostatic Level Measurement

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

General Specifications

TRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights

Level Measurement Continuous level measurement - Ultrasonic transmitters

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Level measurement CleverLevel LBFI Point level detection

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

RT2Y Compact temperature switch intrinsic safety

HLX31 Series. Multifunctional Industrial Transmitter for Humidity / Temperature / Dew Point / Absolute Humidity... Model A. Model B.

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

5 Fieldbus Technology

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Signal conditioning instruments for level switches. Conductive VEGATOR 256C VEGATOR 532 VEGATOR 631. Product Information

General Specifications

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

TEPI11 P/I signal converter

Level Transmitter. Table of dimensions see page 4. Total length B Installation length A SW55 Ø 55 Ø 75

Gladiator Acoustic Switch Series

Magnetic float switch For vertical installation Model FLS

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Level and Flow Measurement. IMP Range

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Prothermo NMT 532. Technical Information. Intrinsically safe multi-signal converter with precision average temperature sensor for inventory control

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

OPTISWITCH 6600 C Technical Datasheet

Pneumatic Control/Feedback

Pneumatic Control/Feedback

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Signal conditioning instruments VEGASCAN 693. Product Information

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Technical Information Promonitor NRF560

ExCos-P Pressure sensor 20 Pa Pa

Continuous level measurement Radar transmitters

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Differential pressure transmitter PASCAL Ci4 Delta P

Spare Parts for RM71 SmartLine Guided Radar Level Meter

VALVES Inline 3/2-, 5/2- & 5/3 Spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

DS 201P. Electronic Pressure Switch. Pressure Port With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Digital Positioner 8049

InBin-P Pressure switches from 5 Pa Pa

Operating Instruction

Technical Information Waterpilot FMX21

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP

Gladiator Admittance Smart Switch Series

Ordering Information - Level Measurement

PTU300 Combined Pressure, Humidity and Temperature Transmitter

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

Temperature measurement TER8 Front-flush and low-invasive resistance thermometers

TECHNICAL INFORMATION Level Probe LGC2

Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

OPTIFLEX 1100 C Technical Datasheet

Transcription:

FOR CLEAN WATER AND SEWAGE WATER HYDROSTATIC LEVEL TRANSMITTERS LEVEL TRANSMITTERS

O U R P R O F E S S I O N NIVOPRESS N HYDROSTATIC LEVEL TRANSMITTERS FOR CLEAN WATER AND SEWAGE MAIN FEATURES Measuring range up to 200 m (656 ft) IP68 protection Remote programmable Submersible or screw-in types Ø 22/24 mm (Ø 0.85/1 inch) tube HART communication 2- or 3-wire versions 2x output (level + temperature) GENERAL DESCRIPTION Built-in Pt100 temperature sensor Overvoltage and inverse polarity protection Wide range of accessories Ex version Can be certified for potable water Available with capacitance ceramic, piezorezistive stainless steel or ceramic sensor moisture filter APPLICATIONS Level and temperature measurement of drinking water wells, tanks, pools Submersible pump control Screw-in submersible type with IP68 protection for applications with risk of flooding Clean or slightly contaminated liquids Sewage, wastewater Draw-down protection Sewage lift station control Saline solutions, seawater The NIVOPRESS N hydrostatic borehole level transmitters are designed to measure the level of clean or contaminated liquids. The pressure sensor at the bottom of the probe measures the hydrostatic pressure (P hydr ) of the liquid column above it and compares with the atmospheric pressure (P atm ). The atmospheric pressure is led to the sensor through a breathing capillary which is equipped with a moisture filter that prevents the moisture reaching the electronics and decreasing the accuracy of the measurement. This enables the atmospheric pressure to be subtracted from the measured pressure to get the hydrostatic pressure which is proportional to the height of the liquid column (h). The electronics converts the sensor s signal into an output signal. If temperature measurement (of the liquid) is needed beside the level measurement a combined (level + temperature) transmitter should be used. The installation and wiring of the transmitter is helped by the wide variety of accessories. A sewage adapter working on the principle of the diving bell can be snapped (NP) or can be screwed (NZ) into the place of the protecting cap to avoid the direct contact between the sensor and the measured contaminated liquid. An extra mechanical protection is built in the NZ type sewage adapters in the form of a mechanical filter. The N-500 types can be used in hazardous environments. The NZ screw-in type transmitters are recommended for applications where there is a risk of flooding. The NB/NG plastic housing types are designed for those applications where the aggressive medium (e.g. saline solutions or seawater) could cause galvanic corrosion of the stainless steel body. NC NP/NK NB/NG APPLICATIONS CLEAN WATER SALT WATER WASTEWATER VISCOUS SEWAGE / SLURRY A: NIVOPRESS NZ B: NIVOPRESS D C: NIVOPRESS NP D: NIVOPRESS NB E: NIVOPRESS ND F: NIVOPRESS NP E: + NAW-104 G: NIVOPRESS NK H: NIVOPRESS NC A C D F G H E B

I S Y O U R L E V E L TECHNICAL DATA Type Sensor type 2-wire (1) High temperature (up to 75 C (167 F)) version is available on special request 3-wire NB, NG NK, NN / ND, NH NC, NT NP, NF / NZ, NR NPH, NFH / NZH, NRH Principle Piezoresistive Capacitance Piezoresistive Material Ceramic Stainless steel Housing Plastic Stainless steel Measuring range Overload allowed (versus range) 0 20 m (0... 65 ft) water head 0 200 m (0... 656 ft) water head As per order code; the current output can be customized in the pressure range from 2% to 130% with remote programming 3 x 20x (h 3 mvo) 10x (h > 3 mvo) Output 4 20 ma 4 20 ma 4 20 ma 3 x 0 10V (0 V 80 mv) measured to the power supply Power supply 12 30 V DC 18 30 V DC / 6 ma Max. load (U t = power supply; U min = min. power supply) Temperature transmitter NPD, NZD types R min = (U t U min ) 0.02 A Power supply: 14 30 V DC / 4 20 ma; 0 +60ºC (32 F... 140 F), Accuracy: ±3 C (±5.4 F) Temperature sensor Pt100 B NoP types NCP types NoP types Linearity error (level) ± 0.45 % ± 0.25 % Temperature error ± 0.1 % / 10 K ± 0.2 % / 10 K Process temperature (1) Process connection Ingress protection Electrical protection Electrical connection Cable Cable length Dimensions Mass Material of wetted parts Type Ø 24x212 mm (1x8.3 inch) Probe: 0.15 kg 30 C... +60 C (-22 F... 140 F) NAA-209 cable mounting wedge clamp, NZ, NR, ND, NH types: ¾ BSP thread NK,NN: Ø 22x173 mm (0.87x6.8 inch) ND,NH: Ø 38x174 mm (1.5x6.85 inch) NK,NN: Probe: 0.2 kg (0.44 lb) ND,NH: Probe: 0.3 kg (0.66 lb) IP68 Class III. Shielded cable with breathing capillary Ø 7 mm (0.275 inch); 0.34 mm 2 (AWG22) 0... 300 m (0... 985 ft) as order code Ø 40x146 mm (1.55x5.75 inch) Probe: 0.4 kg (0.88 lb) 5 k NP,NF: Ø 22x173 mm (0.87x6.8 inch) NZ,NR: Ø 38x174 mm (1.5x6.85 inch) NP,NF: Probe: 0.2 kg (0.44 lb) NZ,NR: Probe: 0.3 kg (0.66 lb) Sensor Al 2 O 3 1.4404 (316L) Housing POM 1.4571 (316 Ti) Cable coating Polyurethane (PUR) or FEP Sealings VITON (FKM) Protecting cap POM 1.4571 (316 Ti) 1.4571 (316 Ti) SPECIAL DATA FOR Ex CERTIFIED MODELS NP / NZ 500 types Protection type Intrinsically safe Ex marking ATEX x II 1G Ex ia IIC T6 Intrinsically safe data Ui = 30 V, Ii = 100 ma, Pi = 0.8 W, Ci = 12 nf+ h x 0.4 nf; Li = 1.3 mh + h x 0.9 µh (h = cable length in meter) Power supply 14 30 V DC Operation temperature range 10 C... 60 C (14 F... 140 F) WIRING Type Cable wire NoK NoH NoD NoP 1 yellow 2 red I+ U+ I+ I+ 3 black/blue I U I I 4 uncolored Uout I +( C) 6 black 7 black/red Pt100 5 uncolored/blue I ( C) L breathing capillary with moisture filter L L L L

DIMENSIONS NP/NK NP/NK+ NAW-104 NZ/ND NZ/ND+ NAZ-103 NC NB/NG NB/NG+ NAW-107 ACCESSORIES A wide range of accessories make an easier and safer installation and usage of the Nivopress N hydrostatic level transmitters. NAA-101: Cable terminal box with moisture filter and terminals for wiring the unit : Cable terminal box with moisture filter and terminals with built-in OVP-22/33 type overvoltage protection unit for wiring the level transmitter NAA-209: Cable mounting wedge clamp OVP-22/33: Outdoor overvoltage protection unit for use in loop with IP54 protection OVP-32/33: Indoor overvoltage protection unit for use in loop with IP20 protection, EN 60715 rail mountable type NAW-104, NAW-107, NAZ-103: Sewage adapter made from 1.4571 (316 Ti) stainless steel or plastic (POM). The NP/NK/NB type probes can be equipped with the suitable sewage adapter (NAW-104 or NAW 107) by snapping instead of the sensor protective cap. The NAZ-103 type sewage adapters can be screwed to the NZ/ND types with ¾ threaded process connection. The air layer below the sewage adapter helps to avoid the direct contact between the sensor and the measured contaminated liquid. NAA-105, NAA-106: Cable sliding sleeve with 1 ½ BSP or NPT thread; material: st. steel 1.4571 (316 Ti) Technical data of the accessories Cable terminal box Dimensions Ingress protection Operating temperature Material Cable gland Electrical connection Cable terminal box with overvoltage protection Data Electrical Data Cable mounting wedge clamp Max. mechanical load Material Operating temperature NAA-101 93 x 93 x 55 mm (3.66 x 3.66 x 2.16 inch) IP65 40 C +70 C ( 40 F... +158 F) Plastic M20x1.5 (cable Ø 5 Ø 10 mm (0.2... 0.4 inch) Terminal block for cable with max. cross section of 2.5 mm 2 (AWG13) (2) See NAA-101 See OVP NAA-209 300 m (985 ft) cable Polyamide, stainless steel wedge clamp 20 C + 60 C ( 4 F... +140 F) Overvoltage protection unit OVP22/33 (2) (2) Type field use EN 60715 rail mountable Dimensions 72 x 42 x 19 mm (2.8 x 1.65 x 0.75 inch) 62 x 65 x 18 mm (2.44 x 2.56 x 0.7 inch) Ingress protection IP54 IP20 Breakdown voltage 33 V Absorbed energy 600 W / 1 ms Serial resistance 13 Leakage current 10 µa NAA 101/102 NAA 105 NAA 209 OVP-32/33 IN 1 (C) ; IN 2 (D); Out 1 (F); Out 2 (E); A,B,H,G = OVP-22/33 (2) only for 2-wire 4 20 ma equipments!

MEASURING CIRCUITS Level transmission Field Control room Level: Level + temperature transmission Level: level Temperature: temperature level Level: Temperature: Thermocont TBW-500-4 temperature Pt100 4-wire temperature Nivopress N TRANSMITTERS IN SYSTEM WITH A PC SAK-305 Instruments with HART output can be connected to a PC interfaced by a UNICOMM HART-USB modem. A HART multidrop loop can consist of a maximum of 15 transmitters. All measured values can be visualized and/or the NIVOPRESS N transmitters can be remote programmed by the PC. Applicable software: EView2 configuration software or NIVISION process visualization software. HART Nivopress N TRANSMITTERS IN HART MULTIDROP LOOP The MultiCONT processes and displays measurement data supplied by NIVELCO s HART equipped transmitters connected to a Multidrop loop. Up to 15 transmitters (also mixed models) can be connected and remote programming can be also performed through the MultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed. RS485

npk4s15a0603b ORDER CODES ( n o t a l l c o m b i n a t i o n s a v a i l a b l e) Nivopress N hydrostatic level transmitters (1) Nivopress N - - Sensor/ housing (conn.)/cable Piezoresistive sensor S. steel housing / PUR P Stainless steel Ceramic (3) S. steel housing / FEP F S.s. housing, threaded / PUR S.s. housing, threaded / FEP S. steel housing / PUR K S. steel housing / FEP N S.s. housing, threaded / PUR S.s. housing, threaded / FEP POM housing / PUR POM housing / FEP G Capacitive sensor S. steel housing / PUR C(2) S. steel housing / FEP T Output Z R D H B (6) K 0 10 V DC (2) (7) H Level: Temperature: (2)(7) Level: Temperature: Pt100 (6) D P Version Range (4) Normal With ceramic sensor 2 (3) Normal With piezo sensor 4 Ex - With piezo sensor 5(5) 0 1 mvo (0 100 mbar) 1 0 2 mvo (0 200 mbar) 2 0 5 mvo (0 500 mbar) 3 0 10 mvo (0 1000 mbar) 4 0 20 mvo (0 2000 mbar) 5 0 50 mvo (0 5000 mbar) 6 0 100 mvo (0 10000 mbar) 7 0 200 mvo (0 20000 mbar) 8 Cable length 0 0 m until 100 m 0 m 0 1 10 m 1 m 1 2 20 m 2 m 2 3 30 m 3 m 3 4 40 m 4 m 4 5 50 m 5 m 5 6 60 m 6 m 6 7 70 m 7 m 7 8 80 m 8 m 8 9 90 m 9 m 9 A 100 m (1) The order code of an Ex version should end in Ex (2) Not available in Ex version (3) For maximum 20 m (65 ft) water height (4) For HART capable units the current output can be customized in the pressure range from 2% to 130% with remote programming (5) NK, NN, ND, NH, NB, NG: Under approval (6) HART communication is not available for N K-200 and N P-200 types (7) Only with stainless steel sensor over 100 m 0 m 0 B 200 m 10 m 1 C 300 m 20 m 2 30 m 3 40 m 4 50 m 5 60 m 6 70 m 7 80 m 8 90 m 9 Nivelco reserves the right to change technical data without notice! ACCESSORIES Specifications in metric & US units! Accessories and auxiliary devices to order NAA-101 Cable terminal box with moisture filter Cable terminal box with moisture filter with OVP 22/33 (only for 2-wire types) NAW-104 Sewage adapter, can be mounted instead of the protective cap (stainless steel) Auxiliary devices Accessories NAW-107 Sewage adapter, can be mounted instead of the protective cap (plastic - POM) NAZ-103 Sewage adapter (for 3/4 threaded process connection (stainless steel) NAA-105 Cable sliding sleeve with cable gland and 1 ½ BSP thread NAA-106 Cable sliding sleeve with cable gland and 1 ½ NPT thread NAA-209 Cable mounting unit with stainless steel wedge clamp OVP-22/33 IP54 rated outdoor overvoltage protection unit for loop OVP-32/33 IP20 rated indoor overvoltage protection unit for loop, rail mountable MultiCONT P-200 Multichannel process controller / display unit, wall mountable NIPOWER PPK-331 24V DC power supply unit, rail mountable THERMOCONT TBW-500 Field display / temperature transmitter unit for Pt100 sensor output, wall mountable UNICONT PKK-312 Current controlled limit switch with SPDT relay output, rail mountable UNICONT PDF-401 Universal current loop indicator for transmitters, wall mountable UNICONT PMM-511 Universal controller / display panel unit UNICONT PGK-301 Ex Intrinsically safe isolator power supply unit, rail mountable UNICOMM SAK-305 HART- USB/RS485 modem for remote programming via PC, rail mountable UNICOMM SAT-304 HART- USB modem for remote programming via PC EView2 FREE download! Configuration software for remote programming via PC NIVELCO PROCESS CONTROL CO. H-1043 Budapest, DUGONICS U. 11. Tel.: (36-1) 889-0100 fax: (36-1) 889-0200 E-mail: sales@nivelco.com http://www.nivelco.com