Huawei Partner IT Product Manual

Similar documents
OceanStor T Series Configuration and Quotation Guide. Security Level:

Cloud-Oriented Converged Storage

Cloud-Oriented Converged Storage

The Best Choice for SMBs

OceanStor 5300F&5500F& 5600F&5800F V5 All-Flash Storage Systems

Huawei OceanStor V3 Converged Storage Systems Pre-sales Training HUAWEI TECHNOLOGIES CO., LTD.

Huawei OceanStor V3 Converged Storage Configuration and Quotation Guide HUAWEI TECHNOLOGIES CO., LTD.

Lightning Fast Rock Solid

OceanStor 6800F V5 Mission-Critical All-Flash Storage Systems

The Fastest Scale-Out NAS

Huawei KunLun Mission Critical Server. KunLun 9008/9016/9032 Technical Specifications

OceanStor V3 Converged Storage System Technical Proposal Template HUAWEI TECHNOLOGIES CO., LTD. Issue 1.2. Date

Huawei Unified Storage Overview. HCS Storage Pre-sales Training

HUAWEI Tecal X8000 High-Density Rack Server

Reconstruyendo una Nube Privada con la Innovadora Hiper-Convergencia Infraestructura Huawei FusionCube Hiper-Convergente

Huawei KunLun Mission Critical Server. KunLun 9008/9016/9032 Technical Specifications

THE SUMMARY. CLUSTER SERIES - pg. 3. ULTRA SERIES - pg. 5. EXTREME SERIES - pg. 9

HUAWEI OceanStor VIS6600T Product Presales Training

Best Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager. Huawei Enterprise BG, IT Storage Solution Dept Version 1.

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FusionServer X6000 High-Density Server

OceanStor V3 Converged Storage Pre-sales Training HCS Storage Pre-sales Training

IBM System Storage DCS3700

Copyright 2012 EMC Corporation. All rights reserved.

Huawei IT Products and Solutions

EMC & VMWARE STRATEGIC FORUM NEW YORK MARCH David Goulden President & COO. Copyright 2013 EMC Corporation. All rights reserved.

Introducing Tegile. Company Overview. Product Overview. Solutions & Use Cases. Partnering with Tegile

Huawei OceanStor 2200 V3 and 2600 V3 Storage Systems. Technical White Paper. Issue 01. Date HUAWEI TECHNOLOGIES CO., LTD.

HUAWEI OceanStor T Series V2 Unified Storage Pre-sales Specialist Training. Version: V1.0( )

Boundless Computing Inspire an Intelligent Digital World

Tiered IOPS Storage for Service Providers Dell Platform and Fibre Channel protocol. CloudByte Reference Architecture

Next Gen Storage StoreVirtual Alex Wilson Solutions Architect

NST6000 UNIFIED HYBRID STORAGE. Performance, Availability and Scale for Any SAN and NAS Workload in Your Environment

IBM Storwize V7000 Unified

DATA PROTECTION IN A ROBO ENVIRONMENT

Dynamically unify your data center Dell Compellent: Self-optimized, intelligently tiered storage

Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture

NetApp AFF. Datasheet. Leading the future of flash

Huawei IT Product and Solution

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://

Reliable Efficient Elastic

OceanStor T Series V200R002 Sales Guide

Dell Fluid Data solutions. Powerful self-optimized enterprise storage. Dell Compellent Storage Center: Designed for business results

EMC STORAGE FOR MILESTONE XPROTECT CORPORATE

Best Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3. Huawei Enterprise BG, IT Storage Solution Dept Version 1.

Data Sheet Fujitsu ETERNUS DX500 S3 Disk Storage System

TECHNICAL SPECIFICATIONS

SAN Storage Array Workbook September 11, 2012

Huawei OceanStor Dorado V3 All Flash Storage. Technical White Paper. Issue 1.0. Date HUAWEI TECHNOLOGIES CO., LTD.

Exam : Title : Storage Sales V2. Version : Demo

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Modern hyperconverged infrastructure. Karel Rudišar Systems Engineer, Vmware Inc.

Disruptive Forces Affecting the Future

VSTOR Vault Mass Storage at its Best Reliable Mass Storage Solutions Easy to Use, Modular, Scalable, and Affordable

Best Practice of HUAWEI OceanStor T Series Solutions for Key VMware Applications

Data Sheet Fujitsu ETERNUS DX200 S3 Disk Storage System

Thinking Different: Simple, Efficient, Affordable, Unified Storage

Dell PowerVault NX Windows NAS Series Configuration Guide

Системы хранения IBM. Новые возможности

Copyright 2012 EMC Corporation. All rights reserved.

QNAP OpenStack Ready NAS For a Robust and Reliable Cloud Platform

Make IT Simple, Make Business Agile With SUSE

DELL STORAGE NX WINDOWS NAS SERIES CONFIGURATION GUIDE

NetApp FAS8000 Series

DELL EMC NX WINDOWS NAS SERIES CONFIGURATION GUIDE

THESUMMARY. ARKSERIES - pg. 3. ULTRASERIES - pg. 5. EXTREMESERIES - pg. 9

Cloud Meets Big Data For VMware Environments

Dell Storage NX Windows NAS Series Configuration Guide

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

Mostafa Magdy Senior Technology Consultant Saudi Arabia. Copyright 2011 EMC Corporation. All rights reserved.

VMAX and XtremIO: High End Storage Overview and Update

São Paulo. August,

Huawei FusionServer. V5 Rack Server HUAWEI TECHNOLOGIES CO., LTD.

Fully Converged Cloud Storage

Dell EMC PowerVault ME4 Series Storage

Dell PowerVault MD Family. Modular Storage. The Dell PowerVault MD Storage Family

Cisco HyperFlex HX220c M4 and HX220c M4 All Flash Nodes

MODERNISE WITH ALL-FLASH. Intel Inside. Powerful Data Centre Outside.

IBM EXAM QUESTIONS & ANSWERS

OceanStor 5000F and 6000F V5 Series V500R007. Product Description. Issue 02 Date HUAWEI TECHNOLOGIES CO., LTD.

SUN ZFS STORAGE 7X20 APPLIANCES

FLASH.NEXT. Zero to One Million IOPS in a Flash. Ahmed Iraqi Account Systems Engineer North Africa

IBM System Storage DS5020 Express

Cisco HyperFlex HX220c M4 Node

Verron Martina vspecialist. Copyright 2012 EMC Corporation. All rights reserved.

High Volumes Storage Fundamentials V2

Data Sheet FUJITSU Storage ETERNUS DX600 S3 Disk System

A Dell Technical White Paper Dell Virtualization Solutions Engineering

IBM Storwize V5000 disk system

Data Sheet FUJITSU Storage ETERNUS DX500 S3 Disk System

Veritas NetBackup on Cisco UCS S3260 Storage Server

Huawei Enterprise IT Product Portfolio

EonStor DS - iscsi Series High-Availability Solutions Delivering Excellent Storage Performance

HUAWEI Tecal X6000 High-Density Server

M-Series Storage Family Comparison

Cisco HyperFlex HX220c Edge M5

Data Sheet Fujitsu ETERNUS DX400 S2 Series Disk Storage Systems

Boost your data protection with NetApp + Veeam. Schahin Golshani Technical Partner Enablement Manager, MENA

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

Isilon Scale Out NAS. Morten Petersen, Senior Systems Engineer, Isilon Division

Transcription:

Huawei Partner IT Product Manual Storage Section HUAWEI TECHNOLOGIES CO., LTD.

Huawei storage products panorama The channel storage products N8500 Clustered S Big Data & Cloud Storage CSS Distributed Storage Active-Active cluster architecture File and block interface 2~24 nodes, up to 15PB capacity SPECsfs2008 3M+ OPS Rich features for data management Open hardware and distributed file system architecture Posix/NFS/CIFS/JDBC/ODBC interface Multi-GE interconnect HDP3500E Data Protection Integrate with NBU DB, file and OS data protection VM data protection S2200T VTL6900 Disk Storage PB level scalability Cluster architecture Inline dedup and postprocessing dedup S2600T/S5500T/S5600T/S5800T Disk Storage Dual controllers 4GB/8GB cache 204 disks Unified Storage, supports both block and file applications Up to 192GB cache Up to 1,440 disks Storage Management Software Storage Software 1 SmartQoS SmartMotion SmartTier SmartCache SmartThin SmartX Insight UltrPath UltraVR UltraAPM Big Data Storage N9000 UDS Massive Storage Full symmetrix distributed architecture 3~288 nodes, up to 40PB capacity SPECsfs2008 5M+ OPS Dynamic storage tiering 10GE/Infiniband high-speed interconnect Amazon S3 compliance EB level scalability High density design, 2PB+ in 1 rack Dorado2100 G2 Dorado5100 Up to 400K IOPS of SPC-1 Access latency low to 500µs Four-level data protection Up to 600K IOPS of SPC-1 Access latency low to 500µs Four-level data protection S6800T VIS6600T 2~8 nodes, Scale-out Virtual Storage HVS85T/HVS88T Up to 384GB cache Up to 1440 disks Up to 250K IOPS of SPC-1 2 ~ 16 controllers Up to 3TB cache Up to 3,216 disks 0~5s RPO Data Replication Software Management Console InfraControl HyperSnap HyperClone HyperCopy HyperReplication

Product Positioning The match for SAN storage by similar specification HW HVS88T (3072GB, 3216Disks) EMC NetApp VMAX 40K (2TB,3200 Disks) VMAX 20K (1TB,2400 Disks) IBM DS8870 (1024GB,1536Disks) HVS85T (768GB,1584 Disks) S6800T (384GB, 1440 Disks) DS8800 (384GB, 1536Disks) DS8700 (384GB, 1024Disks) VMAX 10K (512GB, 1560 Disks) FAS6280 (192GB, 1440 Disks) FAS6240 (96GB, 1440 Disks) S5800T (192GB, 1440 Disks) XIV G3 (360GB, 180 Disks) S5600T (48GB, 1152 Disks) VNX7500 (48GB,1000 Disks) FAS6210 (48GB,1200 Disks) FAS3270 (32GB, 960 Disks) S5500T (32GB, 528 Disks) VNX5700 (36GB, 500 Disks) FAS3250 (40GB, 720 Disks) S2600T (16GB, 276 Disks) VNX5500 (24GB, 250 Disks) FAS3220 (24GB, 480 Disks) E5400 V7000U (Double nodes, 16GB, 240 Disks) FAS2240 (12GB,144 Disks) E2600 V3700 (16GB,120 Disks) FAS2220 (12GB,60 Disks) V3500 (8GB,24 Disks) VNX5300 (16GB,125 Disks) S2200T (8GB, 204 Disks) VNX5100 (8GB, 75 Disks) VNXe3300 (24GB, Disks) V7000U (8 nodes, 32GB, 480 Disks) VNXe3100(8GB, Disks) matching principle according to the numbers of cache and hard disks 2

Product Positioning The main SAN / Unified Storage HUAWEI EMC IBM NetApp HP Dell HDS BAND7 300K~500k S6800T VMAXe XIV FAS6200 BAND6 200K~300k S5800T VNX 7500 V7000U FAS3270 F400 P6000 Compellent BAND5 100K~200K S5600T VNX 5700 DS5300 E7900 FAS3240 F200 P6000 PS6010 BAND4 50K~100K S5500T VNX 5500 DS5100 E7900 FAS3210 P6000 PS6000 AMS2300 BAND3 25K~50K S2600T VNX 5300 DS5020 E5400 FAS2240 P4000 PS4000 AMS2100 BAND2 5K~25K S2200T VNX 5100 VNXe3300 VNXe3100 DS3500 E2600 FAS2040 P2000 MD3600 MD3200 Compellent AMS2500 Product Positioning The main high-end cluster S PRICE(USD) EMC Isilon HUAWEI IBM NetApp FAS BAND9 >1M BAND8 500K~1M BAND7 300K~500K N8500 S200 x400 N7900 SoS FAS6280 FAS6080 BAND6 200K~300K N8500 S200 x400 N6060 SoS FAS6240 FAS6040 N8500 3

Huawei storage specifications at a glance SAN / Unified Storage Specifications Model Architecture IOPS Number of file engine OPS Maximum Disks per drive type number enclosure of drives Cache Host port Power supply Power Consumption S2200T Single/Dual18,000 controller 4/8 204 12 SAS/NL SAS/ 8 Gbps FC or SATA 1 Gbps iscsi AC: 100V 127V 2U control enclosure 365W or 200V 4U hard disk enclosure 527W 240V S2600T Dualcontroller 40,266 * 2 100,000 8/16 276 12/24 8Gbps FC, SSD/SAS/NL 1Gbps iscsi, 10Gbps SAS/SATA Iscsi(TOE) 2U control enclosure 539W 4U hard disk enclosure 441W S5500T Dualcontroller 60,242 * 2/4 200,000 8/16/32 528 12/24 SSD/SAS/NL SAS/SATA S5600T Dualcontroller 102,471 * 2/4/6 300,000 24/48 1152 24 DualS5800T controller 150,286 * 2/4/6/8 400,000 96/192 1440 24 Dualcontroller 250,388 * 192/384 1440 24 S6800T SSD/SAS/NL 8Gbps FC, 1Gbps iscsi, SAS/SATA 10Gbps SSD/SAS/NL iscsi (TOE), SAS/SATA 10Gbps FCoE AC: 100V 127V or 200V 240V DC: -48V -60V 2U control enclosure 539W 2U hard disk enclosure 249W 4U hard disk enclosure 441W 4U control enclosure 800W 2U hard disk enclosure 249W 4U hard disk enclosure 441W 4U control enclosure 830W 2U hard disk enclosure 307W 4U hard disk enclosure 527W SSD/SAS/NL SAS/SATA *: SPC-1 Result Huawei storage specifications at a glance All-solid-state storage & High-end S specifications SPC-1 IOPS Number of host ports Maximum number of Disks per drives or enclosure capacity Model Architecture Dorado2100 G2 Dualcontroller 400,587 8Gb FC : 16 10 Gb iscsi: 8 48 40Gb IB:4 100 Dorado5100 Dualcontroller 600,052 8Gb FC : 40 10GE : 20 96 Cache 96 Drive Host port 25 SLC: 100GB/200GB; emlc: 200GB/400GB 8Gbps FC/ 10GE (iscsi) /40Gb IB 24 SLC: 100GB/200GB; emlc: 200GB/400GB 8Gbps FC/ 10GE (iscsi) Power supply Power Consumption AC: control enclosure: 800W 100V 127V or hard disk enclosure: 200V 240V 450W control enclosure: 492W hard disk enclosure: SLC: 211W/eMLC: 310W engine 830W(2 nodes) N8500 2~24 nodes 3,064,602* 4~16/node 16~192 GB/ 15PB node 12/24 SSD/SAS/NL_ SAS/SATA 10GE/GE AC: 100V 127V/ 200V 240V Storage unit control enclosure: 830W; hard disk enclosure: 550W *: SPECsfs2008_nfs.v3 Result 4

Huawei storage specifications at a glance List of software function software Intended use S2200T S2600T/5500T/ 5600T/5800T S6800T N8500 Dorado SmartQos prioritizing shared storage resources by multi-user or multi-service, to meet the different requirements of service level support support SmartTier According to user-defined policies to store the cold and hot data into different types of drives to achieve Information Lifecycle Management support support SmartMotion automatically balance the data between the old and new hard drives when the hard disk space expands, to eliminate the hotspot in hard disks support support Thin provisioning storage space is allocated based on the actual amount of written data, improve resource utilization HyperThin HyperThin HyperThin(Block) HyperThin SSD data cache Using SSD and hotspot identification technology, the hot data is copied from the HDD to the SSD to enhance the performance SmartCache SmartCache SmartCache Snapshot Based on the point-in-time data copy, provides data protection for local failure HyperImage HyperImage(Block) Snapshot(File) HyperImage HyperImage(Block) Snapshot(File) HyperCopy HyperCopy HyperCopy HyperCopy(Block) HyperClone HyerClone HyperClone(File) The heterogeneous Data migration between heterogeneous devices volume data copy HyperImage Volume cloning provide multiple real-time copies of data volumes, can be used for the production, testing Synchronous remote replication Provide data protection from power outages and disasters, to ensure zero data loss (Synchronous) (Synchronous) (Synchronous) (Synchronous) (Synchronous) Asynchronous remote replication Provide a long distance data protection from power outages and disasters; can accept some data loss (Asynchronous) (Asynchronous) (Block) File Engine Replication(File) (Asynchronous) (Asynchronous) (Block) File Engine Replication(File) (Asynchronous) Host Disk Protection Protect the host disk partition, the operating system and files DiskGuard DiskGuard DiskGuard data protection for application consistency Require the data consistency of application program UltraAPM UltraAPM UltraAPM Storage device management Provide configuration, monitoring and management ISM of storage device ISM ISM ISM ISM S protocols Require standard protocol when hosts access S storage CIFS/NFS/FTP/Http Multipath Provide path selection, path switching when hosts access SAN storage UltraPath UltraPath UltraPath Storage Resource Management Provide the end-to-end management of the storage from the host / virtual machine, network to storage device InfraControl InfraControl InfraControl InfraControl VMware VAAI Compatible with vsphere VAAI to enhance the storage efficiency of virtual machine Support 5.1U1 Support 5.1U1 Support 5.1U1 Vmware SRM Compatible with Vmware SRM interface, realize disaster recovery of virtual machine SRM 5.0; SRM 5.0 Update 1 SRM 5.0; SRM 5.0 Update 1 SMI-S CTP Compatible with SMI-S standard protocols, provides a standard interface for third-party management system SMI-S 1.4 SMI-S 1.4 #: only 2100G2 support *: only 5100 support 5 CIFS/NFS/FTP/Http UltraPath

Starter storage S2200T Target Market SMBs and remote /branch offices Distributed DAS implementations Large enterprise and corporate distributed sites dual controllers Government and education single controller Current FC SAN Implementations Customers with high-bandwidth applications that require strong sequential performance Key selling points: Large file storage Entry-level price, 816TB Value Video capture/streaming Low-end market leader with feature-rich software and SharePoint & CAD meet the full different demand. Backup-to-disk implementations S2200T Controller Enclosure Front view of the controller enclosure (single controller and dual controllers) Controller enclosure Houses 12x3.5-inch hard disks Supports mainstream SAS, NL SAS, and SATA disks Provides four 2+2 redundant coffer disks in the first four slots Rear view of the controller enclosure (dual controllers) Controller and disk integration (dual controller) Provides management network ports and serial ports. Carries one onboard 4x6 Gbit/s SAS port. Supports one expansion I/O module. Carries four onboard GE ports. Rear view of the controller enclosure (single controller) Power module Fan/BBU Controller and disk integration 1+1 redundant Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.) Intelligent fan speed control BBUs are built in the system to provide power failure protection Provides management network ports and serial ports. Carries one onboard 4x6 Gbit/s SAS port. Carries four onboard GE ports. 6

Unified Storage: T Series SAN application server S application server CIFS/NFS FC/iSCSI File engine components Key selling points: Block engine components File & block fusion, network simplifies Innovative Smart Series software, according Disks group components To the need of storage resources Key selling points Customer problems 7 Product features Business Impact Structured and unstructured data coexist Integration reduces the total cost of ownership Large capacity to meet the rapid data growth Rapid data growth Unified storage (files and data blocks) Scalable Flexible Meet stringent SLA requirements Redundant modules provide highly reliability Hot swap technology Designed to provide "five nines" availability A wealth of data protection features To achieve the best level of service High performance access Always available (best state) Data is protected The complexity of the storage tiering Smartcache Policy-based tiering Automated tiering Improve the performance of reading data Easy to manage Automation efficiency Management costs The unified support: files, data blocks Storage optimization technology, including data blocks virtual file deduplication and virtual provisioning Tiered storage (SSD, SAS, NL-SAS) Value-added software Cost-effective Efficient storage utilization Reduce management costs Cost-effective warranty options

T Series components introduction: File Engine The file engine of a T series unified storage system is developed on the Pangea V1R3 hardware platform. It is a 4 U independent engine and resembles the Pangea V1R1 hardware platform (S5500T/S5600T/S6800T controller enclosure). Each controller in the independent engine is a node of the file engine, that is, every engine provides two nodes. Controller File engine One controller is one node. Interface module File Engine S2600T/ S5500T S5600T/ S5800T CPU One Intel Xeon E5504 2.0 GHz One Intel Xeon E5645 2.4 GHz Memory 16GB 24GB Each node has six I/O module slots. Each node has a GE card for heartbeat communication. Each node has an 8 Gbit/s Fiber Channel adapter for array connection. Each node has a maximum of four GE or 10GE adapters for S host interfaces. T Series components introduction: S2600T Block Engine 3.5-inch controller enclosure Houses 12x3.5-inch hard disks Supports mainstream SAS disks, SATA disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots Power module Achieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.) Controller module Provides management network ports and serial ports Carries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard GE ports Fan/BBU Fan speed is intelligently controlled BBUs are built in the system to provide power failure protection 8

T Series components introduction: S5500T Block Engine 2.5-inch controller enclosure: Houses twenty-four 2.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots Independently powers on or off each hard disk 3.5-inch controller enclosure Houses 12x3.5-inch hard disks Supports mainstream SAS disks, NL SAS disks, and SSDs Provides four 2+2 redundant coffer disks in the first four slots Independently powers on or off each hard disk Controller module Fan/BBU Power module Provides management network ports and serial ports Carries two onboard 4x6 Gbit/s SAS ports Supports one expansion I/O module Carries four onboard 8 Gbit/s Fiber Channel ports Fans are in 3+1 redundancy. (The system can tolerate the failure of one fan.) Fan speed is intelligently controlled BBUs are built in the system to provide power failure protection Achieves 1+1 redundancy Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.) T Series components introduction: S5600T/S5800T Block Engine Controller module BBU Dual controllers Automatic CPU frequency control System power-off button 2+2 redundancy DC/AC power failure protection Interface module Fan 12 I/O module slots Up to 1440 hard disks Hot-swappable I/O modules Diversified interface types: 8 Gbit/s Fiber Channel, 4 Gbit/s Fiber Channel, 4x6 Gbit/s SAS, GE/10GE 5+1 redundancy (the failure of one fan is tolerable.) Intelligent fan speed control Power module Management module 1+1 redundancy Hot-swappable 9 Dual power planes (2+2 redundancy) Provides a conversion efficiency of 92%. (The conversion efficiency of golden power supplies is 88%.)

SAN S6800T Key selling points: Highly reliable architecture designed to ensure that the customer's business system is secure High-end quality, mid-range price S6800T Block Engine Control module BBU module Two controllers CPU frequency control, reducing power consumption System power-off button 2+2 redundancy. Supports DC/AC power failure protection Interface module Fan module 5+1 redundancy of fans (Faults on one fan do not affect the normal running of the system.) Intelligent fan speed adjustment Provides 12 I/O modules slots Supports up to 1,440 hard disks Supports hot-swappable interface cards Supports various types of interfaces cards: 8 Gbit/s FC, 4 Gbit/s FC, 4 x 6 Gbit/s SAS, and GE/10GE Power supply module Management module 1+1 redundancy Supports hot swap Dual plane power supply (2+2 redundancy) The transfer efficiency is up to 92% that is higher than that (88%) of gold medal power supply 10

N8500 OceanStor N8500 cluster S storage system is an industry-leading, unified storage platform for high-end applications, with high performance, high scalability, high reliability, high efficient data management features. Key selling points: 1st Leading performance: SPEC 3,064,602 OPS, 2 times to the 2nd No single point failure, high reliability design 15PB flexible space, hundred billion files N8500 N8500 Hardware Infrastructure The N8500 is based on the separation of the clustered S file engine and the storage unit. The engine is either directly connected to the storage unit or cascaded by using the FC switch Suggested storage unit model: S5500T, S5600T, S5800T, S6800T Rack GE switch unit (optional) FC switch unit (optional) Engine unit Storage unit 1 Clustered S File Engine 2 Fabric Cable 3 FC Switch unit 4 Storage unit controller 5 Storage unit disk enclosure 11

Direct connection (two nodes) Two heartbeat links FC port GE port N8500 Engine Heartbeat port Storage unit Direct connection (four nodes) Two heartbeat switches Two heartbeat links N8500 Engine Storage unit FC port GE port Heartbeat port 12

Switch connection (four nodes) Two heartbeat switches Two heartbeat links N8500 Engine FC switches Storage unit FC port GE port Heartbeat port N8500 S File Engine Control module BBU module apron Two controllers Mainstream server platform Automatic frequency adjustment, reducing power consumption System power-off button 2+2 redundancy DC/AC power failure protection Fan module Fan 5+1 redundancy Low power consumption for heat dissipation Granular fan speed control Interface module Local system module Power module By default, each node provides four GE service interfaces, four 8 Gbit/s FC back-end storage interfaces, and two GE heartbeat interfaces Each node provides three PCE2.0 8x interface card slots for the expansion of GE/10GE service interface card or 8 Gbit/s FC back-end storage interface card All the interface cards support hot swapping Embedded reliable SSD as the local system disk Each system module provides an independent management port. Each system module provides a serial port for software debugging 2+2 redundancy 92% power conversion efficiency 13

Storage Unit Controller with Disks: S5500T Block Engine 2.5-inch disk enclosure 24 x 2.5-inch hard disks Support mainstream disks, such as SAS, SATA, and SSD The first four disks are coffer disks, forming 2+2 redundancy Each disk can be independently powered on/off 3.5-inch disk enclosure 12 x 3.5-inch disks Support mainstream disks, such as SAS, SATA, and SSD The first four disks are coffer disks, forming 2+2 redundancy Each disk can be independently powered on/off Control module integrating controller and disk Mainstream desktop CPU platform Provides management network ports and serial ports. Two integrated 6 Gbit/s SAS interfaces. Supports 1 interface module Four integrated 8 Gbit/s FC interfaces Fan module/bbu module Power module Fan 3+1 redundancy Delicate fan speed control Embedded BBU to protect data when a power-off occurs 1+1 redundancy 92% power conversion efficiency Storage Unit Controller without Disks: S5600T/S5800T/S6800T Block Engine Control module BBU module Two controllers Mainstream server platform Automatic frequency adjustment, reducing power consumption System power-off button 2+2 redundancy DC/AC power failure protection Fan module Interface module Fan 5+1 redundancy Low power consumption for heat dissipation. Granular fan speed control 12 interface card slots A maximum of 1440 hard disks All the interface cards support hot swapping Various interface types, such as 8 Gbit/s FC, 6 Gbit/s SAS, GE, and 10GE Management module Power module 2+2 redundancy Hot swap Embedded reliable SSD as the system coffer 2+2 redundancy 92% power conversion efficiency 14

All-solid state storage Dorado Huawei OceanStor Dorado series are high-performance all-solid-state SAN for enterprises, with the advanced cache management and I / O scheduling algorithm, based on the design of all-solid-state storage system architecture, provide users performance experience, to meet the needs of large database, high-performance computing, VDI and other different applications of high-performance storage. Dorado2100 G2 Dorado5100 Dorado2100 G2 Key selling points: 600K IOPS, Microsecond-level access latency, providing ultra high efficiency. Fully redundant architecture, Active/Active mode, enabling services to always remain online. Superior performance SPC-1 IOPS: SPC-1 IOPS 400,587, equivalent in performance to the traditional array with 750 pcs 15K rpm SAS hard drives. Access time: access latency is as low as 500 µs, only 5% of the traditional array delay. Green energy-saving Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same performance, energy saves up to 90%. Stable and reliable Proprietary four level data protection architecture eliminate single point failure, keep business continuing 15

Dorado 5100 Key selling points: 1M IOPS, Microsecond-level access latency, providing ultra high efficiency. Fully redundant architecture, Active/Active mode, enabling services to always remain online. Superior performance SPC-1 IOPS: Dorado5100 provides up to 600,052 SPC-1 IOPS, equivalent in performance to the traditional array with 2000 15K rpm SAS hard drives. Access time: access latency is as low as 500 µs, only 5% of the traditional array delay. Green energy-saving Low power consumption: Typical power consumption of the system is less than 110W, compared to traditional arrays with the same performance, energy saves up to 90%. Stable and reliable Proprietary four level data protection architecture eliminate single point failure, keep business continuing 16

Copyright Huawei Technologies Co., Ltd. 2013. All rights reserved. No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd. Trademark Notice, HUAWEI, and are trademarks or registered trademarks of Huawei Technologies Co., Ltd. Other trademarks, product, service and company names mentioned are the property of their respective owners. General Disclaimer The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an offer nor an acceptance. Huawei may change the information at any time without notice. HUAWEI TECHNOLOGIES CO., LTD. Huawei Industrial Base Bantian Longgang Shenzhen 518129, P.R. China Tel: +86-755-28780808 Version No.: M3-035262-20130719-C-6.0 www.huawei.com