High-throughput optical coherence tomography at 800 nm

Similar documents
Ultrafast web inspection with hybrid dispersion laser scanner

Time-Stretch Imaging and its Applications to High-throughput Microscopy and Microsurgery

The role of light source in coherence scanning interferometry and optical coherence tomography

Company Pioneer in Ytterbium ultrafast lasers High quality manufacturing Intense and active R&D Located in Bordeaux and Paris US offices in Boston and

Enhanced optical absorptance of metals using interferometric femtosecond ablation

The Temporal Gearbox

University of Lübeck, Medical Laser Center Lübeck GmbH Optical Coherence Tomography

OPTICAL COHERENCE TOMOGRAPHY:SIGNAL PROCESSING AND ALGORITHM

Real time micro/nano particle detection and tracking with. nanosecond resolution

Outline. Nuclear Forensics & Laser-Induced Breakdown Spectroscopy. Interferometry & Shadowgraphy. Conclusion & Future Work. Experimental Setup

specular diffuse reflection.

Physics 625 Femtosecond laser Project

Signal post processing in frequency domain OCT and OCM using a filter bank approach

Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

MEMS SENSOR FOR MEMS METROLOGY

Breaking Speed and Sensitivity Limits

Experimental reconstruction of a highly reflecting fiber Bragg grating by using spectral regularization and inverse scattering

Silicon Avalanche Photodiodes in Dynamic Light Scattering

The Future of OCT? Swept Source. Todd J. Purkiss, MD, PhD River City Retina Club July 16, 2015

Roughness Measurement Methodology according to DIN 4768 Using Optical Coherence Tomography (OCT)

Optical coherence tomography with the "Spectral Radar" - Fast optical analysis in volume scatterers by short coherence interferometry

Surface and thickness measurement of a transparent film using wavelength scanning interferometry

Text for the class, Pump-Probe Technique for Picosecond Time-resolved X-ray Diffraction at Cheiron School

Surface and thickness profile measurement of a transparent film by three-wavelength vertical scanning interferometry

Simulation of Simultaneous All Optical Clock Extraction and Demultiplexing for OTDM Packet Signal Using a SMZ Switch

Improved Resolution Optical Time Stretch Imaging Based on High Efficiency In-Fiber Diffraction

7.3 Refractive Index Profiling of Fibers and Fusion Splices

Xuechang Ren a *, Canhui Wang, Yanshuang Li, Shaoxin Shen, Shou Liu

Chapter 7. Widely Tunable Monolithic Laser Diodes

Attosecond Optics. Zenghu Chang Kansas State University University of Central Florida

Optical Topography Measurement of Patterned Wafers

High spatial resolution measurement of volume holographic gratings

Sensor based adaptive laser micromachining using ultrashort pulse lasers for zero-failure manufacturing

Introduction of the Industry's Broadest Tunable Quantum Cascade Lasers. February Block Engineering 1

Recent Advances in Ultrafast Laser Subtractive and Additive Manufacturing

Optics for nonlinear microscopy

Near Field Observation of a Refractive Index Grating and a Topographical Grating by an Optically Trapped Gold Particle

RoHS COMPLIANT 2002/95/EC

LOW-COHERENCE INTERFEROMETRY, AN ADVANCED TECHNIQUE FOR OPTICAL METROLOGY IN INDUSTRY

High-Accuracy LIBS with Nanosecond and Picosecond Time Resolution Enabled by Ultrasensitive emiccd Technology

Systematic design process for slanted graing couplers,

Development of a Simulation Method of Three-Dimensional Ultrafine Processing by Femtosecond Laser Shunsuke Nabetani 1, a, Hideki Aoyama 1, b * 1, 2, c

White-light interference microscopy: minimization of spurious diffraction effects by geometric phase-shifting

Double-Shot 3-D Displacement Field Measurement Using Hyperspectral Interferometry

Real-Time Measurements, Rogue Events and Photon Economics

Text for the class, Pump and probe technique for picosecond time-resolved x-ray diffraction at the Cheiron School

Phase-Contrast Imaging and Tomography at 60 kev using a Conventional X-ray Tube

Time-Resolved measurements by FEL spontaneous emission: A proposal for sub-picosecond pumps & probe structural and spectrometric investigations

Testbed experiment for SPIDER: A photonic integrated circuit-based interferometric imaging system

Coherent Gradient Sensing Microscopy: Microinterferometric Technique. for Quantitative Cell Detection

TRiCAM APPLICATIONS KEY FEATURES. Time Resolved intensified CAMera. TRiCAM 13001A01 31/10/2013

QUANTITATIVE PHASE IMAGING OF BIOLOGICAL CELLS USING OFF-AXIS METHOD OF WIDE FIELD DIGITAL INTERFERENCE MICROSCOPY (WFDIM)

Final Year Projects in Integrated Photonics

Performance of serial time-encoded amplified microscope

Enhancement of Multiplexing Capability of Low-Coherence Interferometric Fiber Sensor Array by Use of a Loop Topology

100 Gbit/s Computer Optical Interconnect

Optical Sectioning. Bo Huang. Pharmaceutical Chemistry

Mode-Field Diameter and Spot Size Measurements of Lensed and Tapered Specialty Fibers

Ultrafast photonic packet switching with optical control

Coherent Microscopy and Optical Coherence Tomography for Biomedical Applications

Nanorelief measurements errors for a white-light interferometer with chromatic aberrations

Enabling Devices using MicroElectroMechanical System (MEMS) Technology for Optical Networking. Dan M. Marom

Fringe modulation skewing effect in white-light vertical scanning interferometry

Multiple optical traps from a single laser beam using a mechanical element

1 Introduction. Teresa C. Chen Harvard Medical School and Massachusetts Eye and Ear Infirmary 243 Charles Street Boston, Massachusetts 02114

Optical Add Drop Multiplexer (OADM) Based on Dense Wavelength Division Multiplexing Technology in Next Generation Optical Networks

Signature Core Fiber Optic Cabling System

A Single Grating-lens Focusing Two Orthogonally Polarized Beams in Opposite Direction

Title. CitationOptics Express, 20(26): B77-B84. Issue Date Doc URL. Rights. Type. File Information

Development of Ultrafast CXRS system in Heliotron J. Graduate School of Energy Science Kyoto University LU XIANGXUN 03/15/2016

Optical WDM-PON Access System with Shared Light Source

High-Power Femtosecond Lasers

The Overlapping Effects of Step Exposure by Laser Interferometric. Lithography System

University of Huddersfield Repository

Optical diffraction gratings embedded in BK-7 glass by low-density plasma formation using femtosecond laser

Available online at ScienceDirect. Procedia CIRP 10 (2013 ) th CIRP Conference on Computer Aided Tolerancing

MICROMACHINING OF OPTICAL FIBRES WITH A NANOSECOND LASER FOR OPTICAL COMMUNICATION AND SENSOR APPLICATIONS

Applications of adaptive optics in femtosecond laser material processing

Theory and Measuring of Antireflection Coatings

Development and validation of a short-lag spatial coherence theory for photoacoustic imaging

Design of AWG-based WDM-PON Architecture with Multicast Capability

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

University of Huddersfield Repository

What is Frequency Domain Analysis?

Efficient Signal Processing Algorithms for Optical Doppler Tomography Literature Survey

Coupling of surface roughness to the performance of computer-generated holograms

A Novel Reconfigurable Ring Architecture of Multiple Secure Private Networks over EPON Using OCDMA Code-Drop Units

Models of Light The wave model: The ray model: The photon model:

Condenser Optics for Dark Field X-Ray Microscopy

Tutorial: Instantaneous Measurement of M 2 Beam Propagation Ratio in Real-Time

Full-field optical coherence tomography by achromatic phase shifting with a rotating polarizer

Layered media and photonic crystals. Cord Arnold / Anne L Huillier

Optical node with time-space-and-wavelength. domain contention resolution, deflection and dropping. dropping capability

LED holographic imaging by spatial-domain diffraction computation of. textured models

Image Reconstruction in Optical Tomography : Utilizing Large Data Sets

HOLOGRAPHIC FEMTOSECOND LASER PROCESSING AND THREE-DIMENSIONAL RECORDING IN BIOLOGICAL TISSUES

WORCESTER POLYTECHNIC INSTITUTE

Laser readiness for all optical EUV FEL

JoshuaE. Rothenberg. Lawrence Livermore National Laboratory, L-493 P.O. Box 808, Livermore, CA 94551

Experimental Observation of Invariance of Spectral Degree of Coherence. with Change in Bandwidth of Light

Transcription:

High-throughput optical coherence tomography at 800 nm Keisuke Goda, 1,2,3,* Ali Fard, 1,2,4 Omer Malik, 1 Gilbert Fu, 1 Alan Quach, 1 and Bahram Jalali 1,2,3,5 1 Department of Electrical Engineering, University of California, Los Angeles, CA 90095 USA 2 California NanoSystems Institute, Los Angeles, CA 90095 USA 3 Department of Bioengineering, University of California, Los Angeles, CA 90095 USA 4 Current Address: Wellman Center for Photomedicine, Massachusetts General Hospital, Boston, MA 02114 USA 5 Department of Surgery, David Geffen School of Medicine, University of California, Los Angeles, CA 90095 USA * goda@ee.ucla.edu Abstract: We report high-throughput optical coherence tomography (OCT) that offers 1,000 times higher axial scan rate than conventional OCT in the 800 nm spectral range. This is made possible by employing photonic timestretch for chirping a pulse train and transforming it into a passive swept source. We demonstrate a record high axial scan rate of 90.9 MHz. To show the utility of our method, we also demonstrate real-time observation of laser ablation dynamics. Our high-throughput OCT is expected to be useful for industrial applications where the speed of conventional OCT falls short. 2012 Optical Society of America OCIS codes: (110.4500) Optical coherence tomography; (120.4825) Optical time domain reflectometry; (060.2370) Fiber optics sensors; (120.3940) Metrology. References and links 1. D. Huang, E. A. Swanson, C. P. Lin, J. S. Schuman, W. G. Stinson, W. Chang, M. R. Hee, T. Flotte, K. Gregory, C. A. Puliafito, and J. G. Fujimoto, Optical coherence tomography, Science 254(5035), 1178 1181 (1991). 2. D. C. Adler, Y. Chen, R. Huber, J. Schmitt, J. Connolly, and J. G. Fujimoto, Three-dimensional endomicroscopy using optical coherence tomography, Nat. Photonics 1(12), 709 716 (2007). 3. R. Huber, M. Wojtkowski, and J. G. Fujimoto, Fourier domain mode locking (FDML): a new laser operating regime and applications for optical coherence tomography, Opt. Express 14(8), 3225 3237 (2006). 4. W. Wieser, B. R. Biedermann, T. Klein, C. M. Eigenwillig, and R. Huber, Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second, Opt. Express 18(14), 14685 14704 (2010). 5. D. Choi, H. Hiro-Oka, H. Furukawa, R. Yoshimura, M. Nakanishi, K. Shimizu, and K. Ohbayashi, Fourier domain optical coherence tomography using optical demultiplexers imaging at 60,000,000 lines/s, Opt. Lett. 33(12), 1318 1320 (2008). 6. S. Moon and D. Y. Kim, Ultra-high-speed optical coherence tomography with a stretched pulse supercontinuum source, Opt. Express 14(24), 11575 11584 (2006). 7. R. E. Saperstein, N. Alic, S. Zamek, K. Ikeda, B. Slutsky, and Y. Fainman, Processing advantages of linear chirped fiber Bragg gratings in the time domain realization of optical frequency-domain reflectometry, Opt. Express 15(23), 15464 15479 (2007). 8. K. Goda, D. R. Solli, and B. Jalali, Real-time optical reflectometry enabled by amplified dispersive Fourier transformation, Appl. Phys. Lett. 93(3), 031106 (2008). 9. D. Stifter, Beyond biomedicine: a review of alternative applications and developments for optical coherence tomography, Appl. Phys. B 88(3), 337 357 (2007). 10. M. Wiesner, J. Ihlemann, H. H. Müller, E. Lankenau, and G. Hüttmann, Optical coherence tomography for process control of laser micromachining, Rev. Sci. Instrum. 81(3), 033705 (2010). 11. B. G. Goode, Optical coherence tomography: OCT aims for industrial application, Laser Focus World. Sep. (2009). 12. K. Goda, D. R. Solli, K. K. Tsia, and B. Jalali, Theory of amplified dispersive Fourier transformation, Phys. Rev. A 80(4), 043821 (2009). 13. K. Goda, K. K. Tsia, and B. Jalali, Serial time-encoded amplified imaging for real-time observation of fast dynamic phenomena, Nature 458(7242), 1145 1149 (2009). 14. S. Gupta and B. Jalali, Time stretch enhanced recording oscilloscope, Appl. Phys. Lett. 94(4), 041105 (2009). 15. Y. Han and B. Jalali, Photonic time-stretched analog-to-digital converter: fundamental concepts and practical considerations, J. Lightwave Technol. 21(12), 3085 3103 (2003). (C) 2012 OSA 27 August 2012 / Vol. 20, No. 18 / OPTICS EXPRESS 19612

16. J. H. Yoo, O. V. Borisov, X. Mao, and R. E. Russo, Existence of phase explosion during laser ablation and its effects on inductively coupled plasma-mass spectroscopy, Anal. Chem. 73(10), 2288 2293 (2001). 17. C. Phipps, Laser Ablation and its Applications (Springer, 2007). 1. Introduction Optical coherence tomography (OCT) has proven to be a valuable tool based on lowcoherence interferometry for micrometer-scale tomographic imaging of turbid media in a diverse range of applications [1,2]. In OCT, the ability to acquire images at high speeds is strongly desirable for a few practical reasons. First, high-speed OCT is useful for probing rapid dynamics and immune to motion artifacts caused by the moving sample or environment in biomedical settings [2 8]. Second, for industrial applications, fast image acquisition is required for inspecting a large quantity of pieces in a short period of time as well as for imaging a large field of view [9 11]. For these reasons, the frequency-domain OCT methods are preferred for field use as they provide higher scan rates and signal-to-noise ratio than the traditional time-domain method [2 8]. In the last decade, efforts have been made for faster OCT. First, a high-speed frequencysweeping technique known as Fourier-domain mode locking (FDML) has been developed through pioneering work of Huber et al [3,4] to perform swept-source OCT at MHz axial scan rates. Different from the operation of conventional frequency-swept lasers, FDML drives an intra-cavity tunable band-pass filter at a period matched with the round-trip time of the cavity and hence overcomes the trade-off between the laser linewidth (i.e., axial range) and build-up time (i.e., sweep rate), producing axial scan rates as high as 5.2 MHz [4]. Another technique that achieves MHz axial scan rates is Fourier-domain OCT with optical demultiplexers recently developed by Choi et al [5]. This method replaces the slow spectrometer with a pair of optical demultiplexers and photodiode arrays, leading to an impressive axial scan rate of 60 MHz at 1560 nm [5]. Finally, the spectrum-stretching method known as frequency-to-time mapping [6,7], dispersive Fourier transformation [12,13], or photonic time-stretch [14,15] has also been shown to provide MHz axial scan rates. This method maps the spectrum of an optical pulse into a temporal waveform using a dispersive element (e.g., a dispersive fiber or chirped fiber Bragg grating) with large group-velocity dispersion (GVD). The resultant chirped pulse train behaves as a passive frequency-swept source, enabling OCT at the axial scan rate equivalent to the pulse repetition rate of the laser [6,7,12 15]. Unfortunately, while photonic time-stretch is effective for ultrafast OCT, its application has, until now, been limited to the fiber-optic communication band (~1550 nm) [6,7,12 15] due to the lack of dispersive elements in the non-telecommunication band, restricting its practical utility. In this paper, we present high-throughput OCT based on photonic time-stretch in the 800 nm spectral range that offers an axial scan rate of more than 90 MHz three orders of magnitude higher than conventional OCT in this spectral range. This is made possible by employing a single-mode fiber with a smaller effective mode area (4 µm mode field diameter) than conventional fibers in the wavelength operation range (typically 5 6 µm mode field diameter). The fiber, hence, provides increased contribution of waveguide dispersion to the total chromatic dispersion of the fiber, enabling photonic time-stretch. As opposed to the 1550 nm spectral range where water absorption is strong, the 800 nm band is useful for OCT s broad range of applications since its axial resolution improves with shorter wavelengths for a fixed optical bandwidth. As a proof-of-principle demonstration, we show a record high axial scan rate of 90.9 MHz. Furthermore, to show the potential utility of our method, we perform real-time monitoring of laser ablation dynamics. Our method is expected to be useful for industrial applications where the speed of conventional OCT falls short, such as material characterization, microfluidics, and manufacturing and process control. (C) 2012 OSA 27 August 2012 / Vol. 20, No. 18 / OPTICS EXPRESS 19613

2. High-throughput OCT 2.1 Schematic The optical layout for our high-throughput OCT, which we refer to as time-stretch OCT, is schematically shown in Fig. 1. The optical source is a mode-locked Ti:Sapphire femtosecond pulse laser that generates a broadband pulse train at a pulse repetition rate of 90.9 MHz. The light is filtered by a band-pass filter, resulting in a center wavelength and bandwidth of 815 nm and 14 nm, respectively, and then enters the photonic time stretcher that consists of a prism-based pre-chirper and dispersive fiber. The pre-chirper is necessary to avoid unwanted supercontinuum generation in the dispersive fiber. The spectrum of each broadband pulse is converted into a temporal waveform by the large GVD of the dispersive fiber ( 615 ps/nm), and then each frequency component of the spectrum illuminates the sample successively in time. The back-reflected pulses from different layers of the sample are interferometrically combined with a reference pulse at the beamsplitter, resulting in an interference fringe in the time domain where the axial information of the sample is encoded. The returned pulse is directed via the optical circulator toward the high-speed amplified photodetector with 12 GHz bandwidth and is digitized by the real-time digitizer with 16 GHz bandwidth and 50 GS/s sampling rate. Inverse Fourier transformation is performed digitally on each measured pulse to obtain the axial profile of the sample. For tomographic image acquisition, an acousto-optic deflector (AOD) is used for high-speed lateral scanning over the sample with 132 resolvable points at 50 khz. Fig. 1. Schematic of time-stretch OCT. The optical source is a mode-locked Ti:Sapphire femtosecond pulse laser that generates a broadband pulse train at a repetition rate of 90.9 MHz. The photonic time stretcher that consists of a prism-based pre-chirper and dispersive fiber maps the spectrum of each pulse into a temporal waveform which is incident onto the sample. Here each frequency component of the spectrum illuminates the sample successively in time. The back-reflected pulses from different layers of the sample are interferometrically combined with a reference pulse at the beamsplitter, resulting in an interference fringe in the time domain where the axial information of the sample is encoded. The returned pulse is directed via the optical circulator toward the high-speed photodetector and is digitized by the real-time digitizer. Inverse Fourier transformation is performed digitally on the measured temporal waveform to obtain the axial profile of the sample. Consequently, axial scanning is performed at the pulse repetition rate of 90.9 MHz. For tomographic image acquisition, an acousto-optic deflector is used for lateral scanning over the sample at 50 khz. (C) 2012 OSA 27 August 2012 / Vol. 20, No. 18 / OPTICS EXPRESS 19614

Fig. 2. Basic performance of time-stretch OCT. (a) Train of temporally dispersed pulses displayed on a high-speed oscilloscope. The interval between consecutive axial scans (pulses) is 11 ns, which corresponds to an axial scan rate of 90.9 MHz. The inset shows one-to-one mapping between the temporal waveform of one of the pulses measured by a real-time oscilloscope and the optical spectrum of the waveform measured by a conventional optical spectrum analyzer, validating photonic time-stretch in the 800 nm spectral range. (b) Singleshot point-spread functions at different imaging depths. The inset shows that the measured axial resolution is 28 µm and is in good agreement with the theoretical estimate of 21 µm. 2.2 Basic performance and theoretical analysis The basic performance of the time-stretch OCT is shown in Fig. 2. The temporally dispersed pulse train displayed on a high-speed oscilloscope is shown in Fig. 2(a), the inset of which indicates one-to-one mapping between the temporal waveform and the spectrum of the waveform measured by a conventional optical spectrum analyzer. The single-shot pointspread functions at different imaging depths are shown in Fig. 2(b), the inset of which indicates the method s reasonable imaging capability with an axial resolution of 28 µm. A theoretical analysis of the time-stretch OCT system was performed to evaluate its performance shown in Fig. 2. First, the axial range is estimated to be 1.3 mm, which we 2 obtained from the relation z= λ / 4δλ [6 8], where 0 λ = 0 815 nm is the center wavelength and δλ is the spectral resolution of the photonic time stretcher. Here δλ is given by δλ = δ t / D [6 8], where λt is the temporal resolution of the detection system and D is the total GVD of the dispersive fiber given by D = 615 ps/nm. The dispersive fiber we used has a linear GVD coefficient of 123 ps/nm/km over 20 nm centered about 815 nm, an absorption loss of 3.2 db/km, and a length of 5 km. Second, the theoretical limit on the axial resolution is found to be 21 µm from the relation, z ( 2 ln 2 / )( ) 2 / 0 δ = π λ λ [6 8], where λ = 14 nm is the optical bandwidth, and is in good agreement with the measured axial resolution (28 µm). For designing a time-stretch OCT system, it is important to take the relations between these basic parameters (i.e., axial range, axial resolution, axial scan rate, GVD, and optical bandwidth) into account. Since consecutive temporally-stretched pulses cannot be overlapped with each other, given the pulse repetition rate ( R ), there is an upper limit on the optical bandwidth such that t= D λ < 1/ R, where t is the width of the temporally-stretched pulse. This relation translates into a lower limit on the axial resolution such that 2 ( 2ln 2 / )( DR 0 ) δ z> π λ. From the parameter values used in this experiment, the lower limit is found to be 17 µm. Alternatively, combining the equations, a trade-off relation between the axial range and resolution can also be obtained, such that z / δ z< π / ( 8ln 2)( R δ t). The sensitivity of time-stretch OCT in this proof-of-principle demonstration was measured to be 42 db (using a variable attenuator in the sample arm of the interferometer) and limited by the electronic noise of the photodetector and the quantization noise of the (C) 2012 OSA 27 August 2012 / Vol. 20, No. 18 / OPTICS EXPRESS 19615

digitizer which are typically large in high-speed detection. Here, the system sensitivity is theoretically estimated to be 45 db from the optical power in each interferometer arm (0.5 mw), the digitizer s quantization noise in the window of 500 mvpp (12.8 nv/hz 1/2 ), and the photodetector s quantum efficiency (0.6), noise-equivalent power (27 pw/hz ½ ), and bandwidth (12 GHz). Note that the dominant noise source is the quantization noise of the digitizer which is very large due to the high-speed nature of the electronic circuitry. Details about the signal and noise of photonic time-stretch systems can be found in Ref [15]. The sensitivity can be improved significantly by employing optical pre-amplification before photodetection, a Mach-Zehnder interferometer in a balanced detection scheme [2 5], or a high-resolution digitizer with low quantization noise. Our analysis shows that the sensitivity of time-stretch OCT can be improved to 80 db or higher. For instance, an optical amplification of 20 db followed by a 12-bit digitizer may be used to achieve this goal. Fig. 3. Real-time observation of laser ablation dynamics with time-stretch OCT. (a) Schematic of the laser ablation experiment. The ablation was performed with a single 5 ns mid-infrared laser pulse focused at an angle onto the silicon sample. The 800 nm pulse train of time-stretch OCT was incident normal onto the surface through the objective lens for real-time monitoring of dynamic changes in the sample s surface axial position during the laser ablation. (b) Dynamics of the axial profile of the ablated surface at a single transverse point. The entire axial profile sequence corresponding to the dynamics (laser-induced mass ejection) caused by the single ablation pulse was captured at an axial scan period of 11 ns in real time. The figure indicates that the sample exploded at t = 200 ns after the ablation pulse arrived at the target at t = 0 ns. The finite time delay between the ablation pulse and the sudden depth change is due to the phase-explosion effect. The standard deviation of the fluctuations in the depth of the reference layer and the ablated layer before the explosion was measured to be 54 nm, which is small relative to the laser induced changes in the axial profile of the sample. (c) Sequence of successive tomographic images with a lateral scan period of 20 µs (corresponding to the lateral scan rate of 50 khz). The ultrafast tomographic image acquisition was made possible by our ultrafast axial scanning. (d) Axial positions at different lateral points around the ablation region indicated in Fig. 3(c). (e) Scanning electron microscope image of the ablated sample, indicating the production of the crater by the laser ablation. 3. Utility of high-throughput OCT To show the ultrafast axial profiling capability of time-stretch OCT, we performed real-time observation of laser ablation dynamics. Laser ablation - removal of material with short powerful laser pulses - is a ubiquitous technology used in laser surgery, material synthesis, (C) 2012 OSA 27 August 2012 / Vol. 20, No. 18 / OPTICS EXPRESS 19616

and laser cutting and micromachining and is an ideal testbed for time-stretch OCT. As shown in Fig. 3(a), the ablation was performed with a single mid-infrared laser pulse (with a fluence of 20 J/cm 2 and pulse width of 5 ns at a wavelength of 2.8 µm) focused at an angle onto a silicon sample. The 800 nm pulse train of the time-stretch OCT was incident normal onto the surface through an objective lens (NA = 0.4) for real-time monitoring of dynamic changes in axial profile during the laser ablation. The lateral resolution is 2 µm (in the lateral scan direction) and 1 µm (in the direction perpendicular to the lateral scan direction) while the lateral range is 260 µm. The real-time axial profile of the ablated layer at a single lateral point (i.e., without lateral scanning) is shown in Fig. 3(b). The entire axial profile sequence corresponding to the laser ablation dynamics (laser-induced mass ejection) was captured with an axial scan period of 11 ns in real time. The figure indicates that the silicon surface exploded at t = 200 ns after the ablation pulse arrived at the target at t = 0 ns. The finite time delay between the arrival of the ablation pulse and the sudden depth change is due to the phase-explosion effect [16,17]. The standard deviation of the fluctuations in the axial position of the ablated surface before the explosion was measured to be 54 nm, which is small relative to the ablation-induced changes. For tomographic image acquisition, we performed the same experiment with lateral scanning. As shown in Fig. 3(c), we obtained a sequence of successive tomographic images with a lateral scan period of 20 µs (corresponding to the lateral scan rate of 50 khz). The ultrafast tomographic image acquisition was made possible by our ultrafast axial scanning. Figure 3(d) shows the dynamics of the sample surface at different lateral points indicated in Fig. 3(c). Since the major part of the explosion occurred within 1 µs after the arrival of the ablation pulse, the lateral scan period of 20 µs did not allow us to see it dynamically although the post-explosion dynamics of the sample is evident on the time scale of 100 µs. A scanning electron microscope image of the ablated sample is shown in Fig. 3(e), indicating the crater produced by the ablation process. 4. Summary In summary, we have demonstrated a method for high-throughput OCT that offers ultrahigh axial scan rate in the 800 nm spectral range. This system is based on the use of photonic timestretch with a single-mode fiber with a smaller effective mode area than conventional fibers in the wavelength operation range for increased contribution of waveguide dispersion to the total chromatic dispersion of the fiber. As a proof-of-principle demonstration, we have shown a record high axial scan rate of 90.9 MHz, and applied the OCT system to real-time observation of laser ablation dynamics. Since the sensitivity of time-stretch OCT is much lower than that of conventional OCT (which operates at low axial rates) due to the large bandwidth of the detection system, we expect that it is useful for non-biological applications (e.g., industrial applications) where high axial scan rates are required at the expense of reduced sensitivity, such as material characterization, microfluidics, and manufacturing and process control. Acknowledgments This work was partially supported by the Microsystems Technology Office (MTO) in the U.S. Defense Advanced Research Projects Agency (DARPA). We are grateful to K. Y. Hon and K. K. Tsia for valuable discussions and assistance with the experimental setup. K. Goda holds a Career Award at the Scientific Interface from the Burroughs Wellcome Fund. (C) 2012 OSA 27 August 2012 / Vol. 20, No. 18 / OPTICS EXPRESS 19617