HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL

Similar documents
Hardware User s Manual. Digital Video Motion Detector DVMD1-X

INSTALLATION INSTRUCTIONS

TAPR GPS Kit USER S GUIDE

CDN220 HIGH DENSITY I/O ADAPTER USER GUIDE

High Resolution Indoor Dome Camera

16 way 19 1½U enclosure with rear cable management tray NPGZM-16-NJ. ½U high front mounting cable management tray

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

ADDENDUM FOR 20, 27, & 28 OPTIONS

Connecting a Cisco Output Module

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Specifications MLC 226 Series

AMU1-CHD+MK2 AUDIO MONITORING UNIT

IC-I AND IC-I F GENERAL DESCRIPTION SPECIFICATIONS. Output Impedance: Phones: 60 ohms (Unit is designed for use with ohm phones.

Moxa TCC-100 Series Hardware Installation Guide

D/E Remote Relay Panel User Guide

Digital Keypad Introduction

NSGV Series "90DM3" Carbon Dioxide Detector

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

INT-HD52 Quick Install Guide

Four opto-isolated signal channels: SD, RD, RTS, and CTS. Electrical compatibility with RS-485. A 5V DC/DC converter for power isolation

INSTALLATION INSTRUCTIONS

ACCUFORCE PRO QUICK START GUIDE

DATA CONNECT ENTERPRISE

INSTRUCTION MANUAL. Dual-System Signal Interface

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

Blue Point Engineering

Connecting a Cisco Input Module

VITA 67 Series. Ideal For Blind Mate Applications. Electrical, Mechanical & Environmental Specifications

Blue Point Engineering

Serial Data DIN Fiber Link System

RS3000 SERIES BILL ACCEPTORS

ISOLATED RS-232 TO RS-422/485 CONVERTER

L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

HyperLink Brand Weatherproof PTZ Camera Lightning and Surge Protector Model: AL-VDP Series

Videum Duo & Quattro Xpress

V-9939C MICROPHONE ADAPTER

Cardfiles (MicroLok II Applications)

SoundwebTM. Installation Guide

E101 - Strain Gauge Transducer Display Module. Contents

Active UTP Transceiver Hub with Integral Isolated Camera Power

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

SRI-02 Speech Recognition Interface

AEROBICS AND VOCAL HEADSET MICROPHONE PM4 PHANTOM POWER ADAPTOR OWNERS MANUAL QE AEROBICS MIC QV VOCAL MIC. PM4 Phantom power adaptor

Specifications WallVault Systems

Installing the DX LCD Display

Omega 4K / UHD Three-Input Switcher for HDMI and USB-C with HDBaseT and HDMI Outputs

TMR1F USER GUIDE AND EVALUATION KIT MANUAL

Specifications WallVault IP Systems

Sierra Radio Systems. HamStack. Project Board Reference Manual V1.0

Installation and Programming Manual. This Manual describes the IBSS InterBus-S Slave, its uses and set up.

WR-5e Remote Control

Temperature Measurement

4 Channel Video Receive Unit with up to 8 Bi-directional Data and Audio Channels plus Ethernet

Specifications PVS 200, PVS 300, PVS 400 Systems

C10- PARALLEL PORT INTERFACE CARD Rev. 8

B&W RearView Camera Installation & Operation

DinBox M36 Hardware Description Guide

OptiStep Hardware Manual

Installation Guide AT-HDVS-SC-RX

SMART SHOT CONTROLLER FLUID USERS GUIDE

Connecting a Cisco Reader Module

Domain 3000 Back Panel

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Transceiver Hub with Integral Camera Power

CLT-302R & CLT-302L CAMERA LINK TRANSLATOR. User s Manual. Document # , Rev 0.2, 7/15/2011

RS-232 Driver Module

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

ES-562/564U COMBINATION CLOCK/TIMER

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

CLM-602 CAMERA LINK MULTIPLEXER. User s Manual. Document # , Rev 0.1, 2/17/2014 (preliminary)

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

EP-ELVCTL Elevator Control (NION-16C48M)

TECHNICAL DATASHEET #TDAX Analog Signal Output CAN Controller (SAE J1939)

UHP-T-LED User Manual

uservo box instruction manual

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Installation Guide Serial Interface T942SI

SYSTEM 4xi PROJECTOR COMMUNICATIONS KIT ATTENTION! PLEASE READ THIS DOCUMENT FOR IMPORTANT INSTALLATION INSTRUCTIONS

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

DVI-0808 Matrix Switcher

Quadrature Encoder User's Manual. Specification and Installation Guide. NetLinc, TLAser400 & PTRBe. Oct 2015

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Copy Machine Reader. Installation and Setup Guide

2M Outdoor Motorized Bullet Camera

FEATURES DESCRIPTION MODEL 110B. Power Supply

BU400,BU400B,UB400B, UB400B, & BI400

PLCADD1616 User Guide 3/29/10. Overview

SoundwebTM. Installation Guide

CFO100 Series. User Manual CRT141 & CRR141. CFO141 User Manual, , rev001

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

PRELIMINARY. Preliminary Technical Datasheet #TDAX Discrete I/O P/N: AX inputs, 8 relay outputs, SAE J1939 with Electronic Assistant

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

DFI 7000 DIGITAL FORCE INDICATOR USER S GUIDE 1.0 INTRODUCTION 2.0 DESCRIPTION. 2.1 Configuration. 2.2 Specifications

Network audio encoder / decoder with I/O for professional and broadcast applications

Vorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual

Yale Card Housing Installation

Transcription:

DVS772HD HD DIGITAL VIDEO A/B SWITCH INSTALLATION MANUAL IB6445-01

DESCRIPTION The DVS772HD high definition DIGITAL VIDEO SWITCH is a high isolation high frequency relay used to switch digital signals with data rates up to 1.485 Giga-Bit. The switch has two inputs and one output in an A/B configuration. The switching function is controlled by an external switch contact, RS232, or TTL type signal. It also has the ability to sense signal loss on the A channel and automatically switch to the B channel. This feature is used when automatic transfer to an alternate channel is desired. The unit comes equipped with a front panel selector switch. The operator can select the data switch to Channel A, Channel B, or Remote operation. When the front panel switch is in the Remote operation position, the unit is controlled by an external input signal or by signal loss on the A Channel if selected. There is a "C" form relay output to report the position of the A/B switch for remote telemetry. The unit has BNC female connectors for the data inputs and output and a removable screw terminal connector for the power and control signals. The switch is housed in a sturdy aluminum die cast box which is completely RF shielded. The box can be mounted in the front or rear of your rack with the standard side-mounting bracket. The unit can be used to engage a hot standby digital source or to put up a test pattern when main data fails. This system will help you maintain your video data integrity and reduce trouble calls. It can also be used where unattended video switching must occur. FEATURES Features of the DVS772HD include a front panel three position command switch which is used to manually force either the primary (A) data channel, secondary (B) data channel, or (REM) remote external and automatic data switching. The unit has front panel LEDs that indicate the status of the data switch. A Green LED indicates the switch is in the (A) channel position, another Green LED indicates when the switch is in the (B) channel position. There is also a Red LED indicator to monitor the data on the (A) channel. If the data signal ceases on the (A) channel the Red LED will go on indicating a failure of the primary (A) channel. Standard BNC female connectors are used for the data inputs and the common output, and a plug-in style removable screw terminal connector is used for the power and status output relay contacts. This removable screw terminal plug can be pre-wired to reduce your installation time. This switcher is housed in a sturdy aluminum die cast box which is completely RF shielded. The box can be mounted in the front or rear of your rack with the standard mounting bracket. An optional 19" mounting bracket is available. The ordering part number is PMS700-5A. It holds 5 units and has a common wall mount power supply to power all 5 units. When using the PMS700-5A you must use right angle BNC adaptors to make the abrupt turn to the rear of the unit for cables to route without kinking. DVS772HD.ISB PAGE 1 OF 4

SET-UP AND INSTALLATION Remove the equipment from the packing materials. The following materials should be supplied with each order. DVS772HD (Blue Box). Power Cube +24 VDC. 6 Position screw terminal Connector (attached). Rack Mount Angle Bracket (attached) or PMS7005A. Locate a convenient place in your rack and mount the unit using the handy Rack Mount Angle Bracket. Next attach the Primary data signal to the input BNC connector labeled (A INPUT). Then attach the Secondary data signal to the BNC connector labeled (B INPUT). The BNC connector labeled (OUTPUT) is the output of the data switch. The data that is selected either manually or automatically will appear at this connector. The OUTPUT DATA MUST HAVE A 75 OHM TERMINATION AT THE END OF THE CABLE. Data signals without proper termination will cause reflected energy and increased bit error rate. Be sure to terminate the output of this data switch by connecting it to downstream equipment or terminate the connector with a 75 Ohm terminator. The 6 position snap in screw terminal connector is wired from left to right, 1 to 6. The following is a table of the connection inputs and outputs used on this connector. The data switch and telemetry output is accomplished by an active electronic relay. 1. "CONTROL" Attach contact switch, RS232 +, or TTL +. 2. "GND" Attach contact switch, RS232 -, or TTL -. 3. "RELAY" Telemetry C form relay output 1. 4. "RELAY" Telemetry C form relay output 2. 5. 24 VDC power input + or -, either polarity. 6. 24 VDC power input - or +, opposite polarity. CONNECTOR BLOCK DIAGRAM 1 2 3 4 5 6 DVS772HD.ISB PAGE 2 OF 4

OPERATION With data present on the Primary channel (A) the red DATA LOSS LED will be off on the front of the unit. This indicates that data is present at the Primary (A) input. On the front panel there is a Three Position LOCKING SWITCH, to move this switch it is necessary to PULL OUT THE HANDLE OF THE SWITCH before trying to change its position. DO NOT FORCE THE SWITCH. There are three command modes for the switch. The first is marked (A), this will cause the DVS772HD to manually force the data switch to the A input source. The second is marked (B), this position will cause a manual switch to the B input. The third position is (REM) which stands for "REMOTE CONTROL". This position will allow a control signal on the 6 position screw terminal to operate the switch. This signal can be a remote switch contact, RS232, or TTL signal from other equipment. Inside the unit there are jumper setting that allow the user to program the operating characteristics of the device. Jumper jacks are used to select the mode of operation. To select a feature simply connect the jumper jack so that it connects the two gold pins on the feature you want to select. J2 selects the operating characteristic of the input signal connected to terminals 1 and 2 of the 6 position screw terminal. If J2 is selected on "NOR" the unit will switch to input B when a contact is closed or a + voltage is applied to terminal 1 of the 6 position screw terminal. If J2 is selected to the "INV" position then the input control is inverted and the unit will switch to the B channel input when a switch is open or a - appears at the terminal 1 of the 6 position screw terminal. If J2 is selected to the "TOG" position then the input control will toggle between A and B each time there is a change in the state of terminal 1 of the 6 position screw terminal. Example: if a switch was connected to control the relay, each time you closed the switch the relay would switch from one input to the other and back again when the switch was closed again. The J3 jumper pins select the "AUTO" automatic data loss switching function. When a jumper is placed onto both pins of the J3 selector the unit will automatically switch from the A channel to the B channel if data is no longer at the A input connector. It will return automatically if the data re-appears on the A connector. The J1 jumper pins select the C form telemetry relay output. When the jumper is selected in the "NO" position the output contacts will be open when the data is switched to the A channel. If you select the "NC" position then the output contacts will be closed when the data is switched to the A channel. This selector lets you set the output relay telemetry contacts to interface with any other equipment. MAINTENANCE There are no field adjustments or calibration required with the DVS772. DVS772HD.ISB PAGE 3 of 4

DATA Standard Level Input Impedance Maximum Data Rate Automatic Switch Level Cross-Talk A/B Front Panel Control Front Panel Indicators SPECIFICATION All Data up to 1.485 Giga-bit Rate 1 V pp Nominal 75 Ohm 1.485 Giga-bit Rate -15 db Below Standard Signal Level <40 db Three Position (A, B, and Remote) Three LED (A, B, A signal loss) MECHANICAL Power requirement Current requirement Connectors (Data) Connectors (Power and Control) Enclosure Mounting 24 VDC Power Cube (included) 110 ma BNC (Female) Plug-in Screw Terminal (6 position) 3.5 x 4.5 x 1.5 Die Cast Aluminum Side Rack Mounting Bracket DVS772HD.ISB PAGE 4 OF 4