RCMB20/RCMB Series

Similar documents
T M. IRDH375 Series. Digital Ground Fault Monitor / Ground Detector For Ungrounded (Floating) AC/DC Systems. Technical Bulletin NAE / 09.

ISOMETER isoev425 with coupling device AGH420

LINETRAXX RCMS150. Residual current monitor type B with integrated measuring current transformers for earthed AC/DC systems (TN and TT systems)

ISOMETER isopv with coupling device AGH-PV

VMD420-DM Voltage and frequency monitor

ISOMETER isoev425/isoev425hc with coupling device AGH420

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

preliminary ISOMETER isoev425 with coupling device AGH420 Preliminary datasheet

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Classification Enclosure rating Input voltage Type of

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

PHOENIX CONTACT Features

ISOMETER iso685-d-b. Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) Preliminary data sheet

- 1 - General ordering data Order No

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

COMTRAXX COM460IP. BMS-Ethernet-Gateway

BMS-Ethernet-Gateway COM460IP

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

VariTrans A The specialist for ±10 V and ±20 ma. With calibrated range selection and broad-range power supply.

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

JUMO mtron T Measuring, Control, and Automation System

COMTRAXX COM465DP. Condition Monitor with integrated gateway for the connection of Bender devices to PROFIBUS DP and Ethernet TCP/IP networks

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Time Counters mini "h", DC Version

Safety controller unit B1 /

DATA SHEET Selectable AC transducer, TAS-331DG

ASI QUINT /2.4 EFD

COMTRAXX COM465IP. Condition Monitor with integrated gateway for the connection of Bender devices to Ethernet TCP/IP networks

Electronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet

Thermistor motor protection relays CM-MSS.12 and CM-MSS.13

Switching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

RM84 miniature relays

Connector System for Fluorescent Lighting Fixtures. Connectors for In-Line Mounting of Fluorescent Lighting Fixtures. Fully Polarized Connectors

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

APS4 Inductive Proximity Sensors

TU531, TU532 Terminal Unit

VariTrans P The Problem The variety of tasks results in a large number of different devices.

Technical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit

Electronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Solid State Remote Power Controller E /627

TF501, TF521 Terminal Bases

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

NEW. Datasheet. WMF 2.5 Terminal Series

MODULES FOR SAFETY AND MONITORING

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

RCM420-DM. Residual current monitor for AC current monitoring in TN and TT systems with an analogue interface Software version: D240 v1.2x.

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

RCMA420-DM Residual current monitor

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B

Overvoltage Protection Devices

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

2U Congestion Alert Rack Insert for UK

Selectronic accessories to support the SelectSun 3 phase grid-tie inverter range

Electronic timer CT-ERS.21

- 1 - Product catalogue PCB connection systems PCB terminals Clamping yoke connection LM 5.00 / 5.08 LM 5.00/135

Item No.: /

QUINT-PS/ 1AC/24DC/ 5

AO523 Analog Input Module

em4 Accessories Digital expansions

Datasheet - SRB 402EM-24V

VTD SERIES p. 108 DC Input, 15 to 600 V. VTD-BD SERIES p. 110 DC Input, 15 to 600 V

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

Positive-guided relay outputs: 4 safety contacts (N/O), instantaneous

Signal Doublers. VariTrans A 20300

Blue ID Power injection module PI60

Thermal-Magnetic Circuit Breaker 2216-S

MINI MCR-2-U-I4(-PT) 3-way signal conditioner. Data sheet. 1 Description

ENERGY /// TE'S CROMPTON INSTRUMENTS TE'S CROMPTON INSTRUMENTS CURRENT TRANSFORMERS

02/11/2015

Products no longer available

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

AI561 Analog Input Module

Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts

8WH5 Combination Plug-In Terminals

Safety control unit B1 / B1. for 2 to 16 machine safety sensors. Use. Types. + PLd according to EN ISO

Installation Instructions

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

E-STOP relays, safety gate monitors

General-Purpose Photoelectric Sensor

Electronic timer CT-ERD.12

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

MIC-2 MKII, Multi-instrument DATA SHEET

Power supply CP-C 24/5.0

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

Electronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet

Transcription:

4 T M /-500 Series Integratable Ground Fault Monitoring Modules For Integration Into Frequency Converters and Combiner Boxes Technical Bulletin NAE1042510 / 10.2012

BENDER Inc. 700 Fox Chase, Coatesville PA 19320 Ph: 800-356-4266 / 610-383-9200 Fax: 610-383-7100-500 / -500 Series Integratable Ground Fault Monitoring Modules Description -500 and -500 series ground fault monitoring modules are designed for fault current monitoring in AC/DC systems. All monitoring electronics are built into the measuring current transformer. The small form-factor devices are designed for integration into equipment and panels on the line side, such as frequency converters, inverters, and combiner boxes. Push-wire terminal connectors and insulated wire ensure simple installation and integration. -500 models feature a 0.78" (20 mm) opening, and -500 models feature a 1.38" (35 mm) opening. Both models have a 4-20 ma output, proportional to the RMS value of the measured ground fault current (up to 500 ma). -500-01 / -500-01 Features Integratable device for AC/DC fault current monitoring RMS value measurement (AC + DC) 0-500 Hz frequency range Measuring electronics integrated into current transformer 0.78" (20 mm) and 1.38" (35 mm) openings for system conductors 500 ma measuring range 24 VDC supply voltage 4-20 ma analog output CT connection monitoring utilizing cyclical test current Multicolor LED for device status Approvals Applications Integration into frequency converters / inverters / VFDs Integration into combiner boxes in PV systems Function Once the supply voltage is applied, the multicolor LED will display green during normal operation (flashing red indicates a device fault) and will carry out an internal self-test. The device measures both AC and DC currents. The RMS value is calculated by summing the DC components included in the ground fault current and AC components below 500 Hz. A 4-20 ma analog output proportional to this RMS value is provided at the module output. This value is updated at the latest every 20 ms. Every two seconds, the device cyclically tests the connections to the current transformer, as well as the proper functioning of the AC and DC measurement. In addition, the supply voltage is monitored continuously. If a fault occurs, the LED will flash red and the analog output will go to 20 ma. Ordering Information Type Supply voltage U S Inside diameter Ordering No. -500-01 DC 20.4 28.8 V* ø 0.78" (20 mm) B 9404 2101-500-01 DC 20.4 28.8 V* ø 1.38" (35 mm) B 9808 2102 * Voltage range absolute values Scope of Delivery The connecting kit included with each device includes the following components: Standard Accessory Dimension/Length Qty. -500-01: Single conductor with integrally moulded ferrule (black, white, red, blue) 45 cm 4 PVC insulating tube 45 cm 1-500-01: Single conductor with integrally moulded ferrule (black, white, red, blue) 80 cm 4 PVC insulating tube 80 cm 1-500-01, -500-01: Push-wire plug, 4-pole, coded 2 Assembly bracket for current transformer 1 Ferrule (mm2 x mm) 0.5 x 6 4 wire strap (mm x mm) 100 x 2,5 2 Lens head screw M6 x 12 2 Spring washer M6 2

Sample wiring diagram - frequency converter Connect the ground fault monitoring module according to the wiring diagram. The output current in proportion to the residual current I A must be made available to the frequency converter. L1 L2 L3 GND a e d c T 100 ma + + U S = DC 24 V I A = 4 20 ma M 3~ Sample overview - combiner box integration Below is an overview diagram for integrating / modules into individual combiner boxes in PV systems. Combiner Box 1 / 35 Inverter Master Combiner Box Combiner Box 2 MCB / 35 Combiner Box 3 / 35

Technical data Insulation coordination acc. to IEC 60664-1 / IEC 60664-3 Rated insulation voltage AC 800 V Rated impulse voltage/pollution degree 12 kv / 2 Overvoltage category CAT III Protective separation (reinforced insulation) between primary conductor and the measurement electronics Voltage tests according to IEC 61010-1 6.88 kv Supply voltage Supply voltage U S DC 24 V Operating range of U S 20.4 28.8 V Ripple U S 1 % Power consumption 2.5 VA Measuring circuit Measuring current transformers /, inside diameter 20 mm / 35 mm Rated insulation voltage (measuring current transformer) 800 V Operating characteristics according to IEC 62020 and IEC/TR 60755 AC/DC sensitive, Type B Rated frequency 0 500 Hz Measuring range I Δn AC/DC AC/DC 0 500 ma Nominal current at 3 N AC ( / ) 32 A / 80 A Relative uncertainty for DC ± 4 % * Relative uncertainty for 10 30 Hz +3 % -15 % * Relative uncertainty for 30 400 Hz ± 3 % * Relative uncertainty for 400.500 Hz ± 10% * Resolution measuring circuit 2 ma Test winding yes Time response Response delay t on 0 s Delay on release t off (if outside the measurement range) 1 s Operating time t ae at IΔ 180 ms Response time t an = t ae + t on Recovery time tb 1 s Displays LED constantly illuminated in green = operation indicator flashes red = fault (output current > 20 ma) Outputs Current output, proportional to the residual current DC 4 20 ma Current output, resolution I Δn = 31.25 x (analogue output current 4 ma) Load 300 Ω Environment / EMC EMC IEC 60947-2 Operating temperature -25 70 ºC Climatic class acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice) Transport (IEC 60721-3-2) 2K3 (except condensation and formation of ice) Long-term storage (IEC 60721-3-1) 1K4 (except condensation and formation of ice) Classification of mechanical conditions acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3M4 Transport (IEC 60721-3-2) 2M3 Storage (IEC 60721-3-1) 1M3 Chemical stresses acc. to IEC 60721 Stationary use (IEC 60721-3-3) 3C4 Connection Primary conductor: (assuming no additional insulation) 4 x AWG 10 (6 mm2) / 3 x AWG 8 (10 mm2) / 2 x AWG 6 (16 mm2 4 x AWG 2 (35 mm2) / 3 x AWG 1 (50 mm2) / 2 x AWG 2/0 (70 mm2 Connector XK1: Connection type Connection properties: rigid Flexible without ferrules Flexible with ferrules Stripping length Opening force pluggable push-wire terminals 2 x four-pole 0.2 2.5 mm2 (AWG 24 14) 0.2 2.5 mm2 (AWG 24 14) 0.2 1.5 mm2 (AWG 24 16) 10 mm 50 N General data Operating mode continuous operation Position any position Degree of protection, internal components (DIN EN 60529) IP40 Degree of protection, terminals (DIN EN 60529) IP20 Enclosure material polycarbonate Flammability class UL94 V-0 Screw mounting M5 with mounting brackets DIN rail mounting acc. to IEC 60715 Software version D378V1.0 (-500-01) D379 V1.0 (-500-01) Weight 200 g () 250 g () * of upper range value

Connection Position of the terminals, connecting and disconnecting of the conductors Plug-in terminal wiring Socket coding Pluggable push-wire terminal Terminal Coulor / a black GND (U S) b a b c d c white DC 4 20 ma d blue GND (DC 4 20 ma) e red +24 V (U S) e 1 2 3 4 f g h f XK1 g h Dimensions: Main enclosure Dimensions in inches (mm) Dimensions: Screw mounting (2 brackets, diagonal) Dimensions in inches (mm) Dimensions: Main enclosure Type A B C D E F G H 1.18 (30) 2.22 (56.3) 1.97 (50) 3 (76.4) 1.91 (48.5) ø 0.79 (ø 20) 1.17 (29.8) 0.65 (16.4) Dimensions: Screw mounting Type A B C D 1.85 (47) 1.14 (29) 2.48 (63) 0.8 (20.35) 1.18 (30) 3.12 (79.2) 2.44 (62) 3.92 (99.5) 2.17 (55) ø 1.38 (ø 35) 1.64 (41.7) 0.79 (20) 1.85 (47) 1.91 (48.5) 2.48 (63) 0.51 (12.85)

North American Headquarters Coatesville, PA Toll-Free: 800-356-4266 Main: 610-383-9200 Fax: 610-383-7100 E-mail: info@bender.org T M bender.org bender.org/mobile Canada Mississauga, ON Toll-Free: 800-243-2438 Main: 905-602-9990 Fax: 905-602-9960 E-mail: info@bender-ca.com Document NAE1042510 / 10.2012 / Bender Inc.