TSX SERIES High power laboratory DC Power Supplies

Similar documents
AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

MX SERIES 315W to 420W Multi output dc power supplies. Measurably better value

AIM & THURLBY THANDAR INSTRUMENTS

AIM & THURLBY THANDAR INSTRUMENTS

T H U R L B Y T H A N D A R I N S T R U M E N T S

T H U R L B Y T H A N D A R I N S T R U M E N T S

T H U R L B Y T H A N D A R I N S T R U M E N T S

THURLBY THANDAR INSTRUMENTS. PL & PL-P Series. Laboratory Power Supplies. Standard and Programmable models, 35 watts to 240 watts

Sorensen XEL & New XEL-P Series

QL Series THURLBY THANDAR INSTRUMENTS. Precision laboratory dc linear power supplies

AIM & THURLBY THANDAR INSTRUMENTS

T H U R L B Y T H A N D A R I N S T R U M E N T S

Sorensen XT Series W A. 60 Watt Linear Performance DC Power Supply V. Low noise and ripple. Excellent line/load regulation

Programmable Dual-Range DC Power Supplies 9170 & 9180 series

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Programmable Dual-Range DC Power Supplies 9170B & 9180B Series

Agilent E3640A E3649A Programmable DC Power Supplies. Data Sheet

Keysight U8030 Series Triple-Output DC Power Supplies

Sorensen XT Series W A. 60 Watt Linear Performance DC Power Supply V

Programmable DC Power Supplies XLN Series

Agilent E3640A E3649A Programmable DC Power Supplies

Sorensen DLM 600 Series W V 2 75 A. Half Rack Programmable DC Power Supply

Series Watt DC Power Supplies

QL Series II. Precision Power Supplies INSTRUCTION MANUAL

Applications Electronic Design/Development Battery Charging Launch Control Rackmount ATE Systems. DLM 600 Near Linear 600W DC Power Supply

Produkt-Datenblatt. Technische Daten, Spezifikationen. MEsstechnik fängt mit ME an. Kontakt

R&S HMC804x Power Supply 100 W and 1, 2 or 3 Channels

REGULATED DC POWER SUPPLIES.

Multi-Range Programmable DC Power Supplies 9115 Series

There are 6 models of the PLR-series. Model number, output voltage, output current and output power are as follows:

E36300 Series Triple Output Bench Power Supply DATA SHEET

Agilent U8000 Series Single Output DC Power Supplies. Data Sheet

Power Supply Selector Guide

LAB-DSP HIGH DENSITY DC POWER SOURCE

Programmable Switching D.C. Power Supply (Multi-Range D.C. Power Supply)

Features. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Output Connectors. Overvoltage Protection. Over Temperature Protection

3A SERIES MODULAR AC & DC LOADS

Agilent E363xA Series Programmable DC Power Supplies

NEW! ZERO-UP. Control Flexibility for Worldwide Applications 200W/400W/800W. Built-in RS232 & RS485 Interface with GPIB optional.

Features. Conducted Emission. Radiated Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors.

DP700 Series. Programmable Linear DC Power Supply. Batter Fly s.r.l. - Tel

Features. Conducted. Emission. Line Regulation. Load Regulation. Safety. Cooling. Input Connectors. Overvoltage Protection. Phase Loss.

Keysight Technologies E3640A E3649A Programmable DC Power Supplies. Data Sheet

Multiple Output Linear DC Power Supply

Keysight Technologies 6550A Series Single-Output, 500 W DC Power Supplies

There are 6 models of the PLR-series. Model number, output voltage, output current and output power are as follows:

AP SERIES SYSTEMS POWER SUPPLIES. Autoranging power supplies for bench or systems use FEATURES

PS U Series W to 3000 W. Programmable DC Power Supplies THE POWER TEST EXPERTS.

DPS SERIES DC POWER SUPPLIES

Programmable DC power supplies

Programmable Digital Controlled DC Power Supplies

REGULATED DC POWER SUPPLIES

Variable Regulated DC Power Supplies PAD-LA Series

GEN W SERIES. LXI Compliant LAN. Laboratory Power Supplies: 750 ~ 1500W. Features. Programming Options: How to order:

Keysight Technologies E36100 Series Programmable DC Power Supplies. Data Sheet

Programmable Power Supply ( Supplies )

Sorensen SG Series kw V A. Programmable Precision High Power DC Power Supply

Programmable Power Supplies 188 W 384 W HMP Series

Keysight Power Products Selection Guide June 2014 A guide to power product solutions to match your test and measurement needs

360W and 720W Programmable DC Power Supplies

Features. LXI Compliant LAN. Power W GEN V 0 55A 3300W GEN V 0 42A 3300W GEN V 0 33A 3300W GEN V 0 22A 3300W

Features. LXI Compliant LAN. Power GEN V 0 65A 5200W GEN V 0 50A 5000W GEN V 0 34A 5100W GEN V 0 25A 5000W

How to Convert from a Sorensen DLM to an Agilent N5700

Keysight Technologies E36100B Series Programmable DC Power Supplies. Data Sheet

New PL & PL-P Series. Precision Linear DC Power Supplies

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

RIGOL Data Sheet. DP1308A Programmable Linear DC Power Supply. May 2009 RIGOL Technologies, Inc. Product Overview. Easy to Use Design.

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY

Multiple Application Platform MAP-200

Precision Measurement, Low Noise, Programmable DC Power Supplies

Single-output and dual-output power supplies. TOE 8840 up to 160 W TOE 8850 up to 320 W. In-phase regulation

PROGRAMMABLE DC POWER Supply MODEL 62000P SERIES MODEL 62000P SERIES. Programmable DC Power Supply PFC

Programmable Switching DC Power Supply

Advanced Test Equipment Rentals ATEC (2832)

QPX600D & DP. PowerFlex+ Dual DC Power Supplies

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Features. LXI Compliant LAN. Power GEN V 0 40A 2400W GEN V 0 30A 2400W GEN V 0 24A 2400W GEN V 0 16A 2400W

Control Flexibility for Worldwide Applications

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

capability for accurate voltage and cur- readings of the UUT s input parameters. 8 bit TTLs, DC-ON, fault output signal and

Keysight Technologies Power Products. Selection Guide

Sorensen SG Series - Water Cooled kw V A. Programmable Precision High Power DC Power Supply

Series. Programmable DC Power Supplies 200W/400W/600W/800W in 2U Built-in USB, RS-232 & RS-485 Interface

An ISO 9001 Company. KLP POWER SUPPLY

Series 2260B Programmable DC Power Supplies

QPX1200S & QPX1200SP. PowerFlex DC Power Supplies INSTRUCTION MANUAL

Keysight Technologies E36300 Series Triple Output Bench Power Supply. Data Sheet

Multiple Application Platform MAP-200

Variable Regulated DC Power Supplies PAD-LA Series

Laboratory Switch Mode Power Supply Series. Instruction Manual

Agilent L4433A Dual/Quad 4x8 Reed Matrix

EPS Stromversorgung PSE U. Operating Guide. DC High Efficiency Power Supply

A. C.V/C.C PRIORITY MODE

KONSTANTER SPL Series Programmable Electronic Load

Elektro-Automatik PS U. Operating Guide. DC High Efficiency Power Supply

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

Transcription:

TSX SERIES High power laboratory DC Power Supplies 350/360 watts, standard and bus programmable Low noise, excellent transient response CV & CI operation with automatic crossover Comprehensive protection including variable OVP trip High setting resolution, remote sense terminals USB, RS232, GPIB and LAN (LXI) interfaces aimtti.com aimtti.us

POWER WITH PRECISION & SIMPLICITY High accuracy digital meters, current meter damping High power levels in a compact & lightweight casing SELV compliant Universal mains input ~ 110-240V 35V-10A & 18V-20A models Low noise, excellent transient response High setting resolution, remote sense terminals CV & CI operation with automatic crossover Fan-free operation Bench or rack mounting,front & rear terminals Comprehensive protection including variable OVP trip THE TSX The TSX model incorporates conventional analog controls for precision with simplicity. Coarse and fine voltage controls offer fast setting with high setting resolution at all levels while a semi-logarithmic current control provides resolution commensurate with the current level. Fan-free operation means that these PSUs add no noise to the bench environment. These PSUs are ideally suited to general purpose applications in many technology areas. HIGH ACCURACY METERING All TSX models incorporate high resolution digital meters for both voltage and current. V and I levels can be set to high accuracy prior to connection to the load and the limit settings can be checked at any time. A damping switch for the current meter enables the average value of rapidly changing currents to be read. LINEAR POST REGULATION FOR UNRIVALLED PERFORMANCE The heart of all TSX PSUs is an innovative regulator design which combines switch mode pre-regulation with linear postregulation. The pre-regulator uses specially developed techniques to dramatically reduce the capacitance between input and output thus eliminating the high levels of common-mode noise normally associated with switch mode PSUs. The linear post-regulator combines very low levels of output noise with excellent load regulation and transient response. The result is performance comparable with a pure linear design. CONSTANT VOLTAGE OR CONSTANT CURRENT OPERATION All TSX PSUs can operate in both constant voltage and constant current modes with automatic crossover and automatic mode indication. FULL OVERVOLTAGE PROTECTION All versions incorporate a fully variable OVP trip to protect against regulator failure. The output is fully protected and other protection functions include regulator overtemperature, and sense miswiring. COMPACT AND LIGHTWEIGHT The hybrid regulator design provides a PSU which is both smaller and lighter than competitive products. The high thermal efficiency also means that the PSUs are silent in operation since fan cooling is unnecessary *. BENCH OR RACK MOUNTING The attractively styled casing takes up very little bench space. The case is half rack width (3U height), an optional rack-mount kit is available. Output terminals are fitted at both front and rear. * Note that in rack environments with limited ventilation fan cooling may become necessary

POWER WITH PROGRAMMABLE VERSATILITY SELV compliant USB, RS232,GPIB* and LAN (LXI) interfaces Keyboard setting of all parameters Low noise, excellent transient response High setting resolution, remote sense terminals CV & CI operation with automatic crossover Fully programmable with bus readback of volts and amps Comprehensive protection including variable OVP trip Fan-free operation Universal mains input ~ 110-240V 35V-10A & 18V-20A models Bench or rack mounting, front & rear terminals Watts display, non-volatile storage of 25 settings Delta (step) control of volts and amps High accuracy digital meters, current meter damping High power levels in a compact & lightweight casing *Optional THE TSX-P The TSX-P contains all of the features of the TSX alongside a wealth of ease of use orientated keyboard functions with full remote programmability. A THIRD DISPLAY FOR CLARITY AND SAFETY To provide additional data and to avoid the possibility of ambiguity or error an auxiliary display is incorporated. All keyboard entries appear on this display for inspection before they are actioned. This failsafe system avoids such possibilities as setting 25 Volts instead of 2.5 Volts. The auxiliary display is also used to set and display a variety of useful information. KEYBOARD OR QUASI-ANALOG CONTROL Voltage and current levels can be entered directly from the keypad to a resolution of 10mV or 10mA giving unparalleled speed and precision. Alternatively a rotary control can be used to set voltage or current in a manner simulating a conventional analog WATTS DISPLAY FOR ADDED CONVENIENCE When not being used for other purposes the auxiliary display shows the output power in Watts (Volts x Amps). DELTA-MODE CONTROL Voltages and currents can be stepped up and down by a fixed increment set from the keyboard. This facility is invaluable for repetitive testing where, for example, the effect of 1% changes in voltage need to be observed. The delta increment is clearly shown on the auxiliary display. NON-VOLATILE STORAGE OF MULTIPLE SETTINGS 25 non-volatile memories are provided for storing frequently used settings. Each store holds a voltage, current and OVP setting. This facility is particularly useful in repetitive testing situations within production, development or inspection areas.

POWER WITH PROGRAMMABLE VERSATILITY COMPREHENSIVE BUS INTERFACES [TSX-P] To meet a wider variety of growing needs, the TSX-P provides a comprehensive array of digital bus interfaces. GPIB (optional), USB, RS-232, and LAN (Ethernet) with LXI support are all included. The GPIB interface is compliant with IEEE-488.1 and IEEE-488.2. GPIB remains a widely used interface for system applications. An RS-232/RS-423 interface is provided for use with legacy systems. This type of serial interface remains in common usage and is perfectly satisfactory for lower speed applications. USB provides a simple and convenient means of connection to a PC and is particularly appropriate for small system use. A USB driver is provided which supports Windows 2000 and above including Win 8 and 10. The LAN interface uses a standard 10/100 base-t Ethernet hardware connection with ICMP and TCP/IP Protocol for connection to a Local Area Network or direct connection to a single PC. This interface supports LXI and is highly appropriate for system use because of its scalable nature and low cost interconnection. The LAN interface is LXI compliant. LXI (LAN extensions for Instrumentation) is the next-generation, LAN-based modular architecture standard for automated test systems managed by the LXI Consortium, and is expected to become the successor to GPIB in many systems. For more information on LXI go to: www.aimtti.com/go/lxi BUS FUNCTIONS Bus controlled functions include set voltage, set current, set OVP, set output on/off, read voltage, read current. LABVIEW & IVI DRIVER An IVI driver for Windows is included. This provides support for common highlevel applications such as LabView*, LabWindows*, and Keysight VEE*. * LabView and LabWindows are trademarks of National Instruments Keysight VEE is a trademark of Keysight Technologies. Windows is a trademark of Microsoft.

TSX and TSX-P Technical Specifications OUTPUT SPECIFICATIONS Operating modes: Voltage range: Current range: Overvoltage protection: Load regulation: Line regulation: Ripple & noise: (20MHz bandwidth) HF common mode noise: Transient response: Temperature coefficient: Overvoltage protection delay: Protection functions: Status indication: Output terminals: Output protection: METER SPECIFICATIONS Meter types: Meter resolutions: Meter accuracies: GENERAL Input voltage range: Power requirement: Electrical safety: EMC: Temperature: Cooling: Size: Weight: Rack mount Options: FRONT PANEL CONTROLS - TSX Voltage setting: Current setting: Overvoltage setting: Output On/Off: Constant voltage or constant current with automatic crossover. 0V to 35V (TSX3510/TSX3510P) 0V to 18V (TSX1820/TSX1820P) 0A to 10A (TSX3510/TSX3510P) 0A to 20A (TSX1820/TSX1820P) 1V to 40V (35V/10A); 1V to 25V (18V/20A). For any load change, measured at the O/P terminals, using remote sense: - Constant voltage: <0.01% ± 5mV - Constant current: < 0.01% ±0.5mA Change in output for a 10% line change: - Constant voltage: <0.01% ± 5mV - Constant current: < 0.01% ± 250uA Typically <1mV rms; <3mVrms max in CV mode Typically <3mA rms; <5mArms max in CI mode Typically <3mV rms, <15mV pk. 100μs to within 50mV of setting for a 5% to 95% load change. Typically <100ppm/ C. <200μs. Overvoltage trip. Regulator over temperature. Sense miswiring. LED indicators for Output ON, constant voltage mode, constant current mode, current meter damping, remote operation, and LAN status; trip & error messages on display. Front panel: Universal 4mm safety binding posts on 19mm (0 75 ) spacing Rear panel: Terminal block screw terminals. Forward protection by Over-Voltage-Protection (OVP) trip. Output will withstand an applied forward voltage of up to 50V (35V/10V), 35V (18V/20A) Reverse protection by diode clamp for reverse currents up to 3A. Dual 4 digit meters with 12 5mm (0.5 )LEDs. Reading rate 4Hz 10mV,10mA. Voltage 0.2% of reading ± 1 digit, Current 0.5% of reading ± 1 digit. 110V 240V AC ± 10%, 50/60Hz. Installation Category II. 600VA max. Complies with EN61010-1. Complies with EN61326-1. Operating: +5 C to +40 C, 20% to 80%RH. Storage: -40 C to +70 C. Fan-less convection cooling. 200 x 140 x 385mm (WxHxD); Half rack width x 3U height. 4.5kg (TSX versions) 5.0kg (TSX-P versions) 3U Rack Mount for half rack width instruments, (RM300A) Via single rotary controls for coarse and fine Via single turn semi-logarithmic rotary Via screwdriver adjustable preset potentiometer. Latching push-push switch operating electronic power Thurlby Thandar Instruments Ltd. operates a policy of continuous development and reserves the right to alter specifications without prior notice. * Labwindows is a trade-mark of National Instruments Corporation. FRONT PANEL CONTROLS - TSX-P Voltage setting: Current setting: Overvoltage setting: Output On/Off: Delta Mode: Store/Recall: Address Setting: Damping ON/OFF: Direct keyboard entry or quasi-analog rotary Direct keyboard entry or quasi-analog rotary Direct keyboard entry. Push button control with indicator lamp operating electronic power Increase or decrease voltage or current in userselectable steps. Store and recall voltage, current and OVP levels from non-volatile memory (25 memories). Set GPIB address Sets current meter damping ON or OFF NOTE: all voltage and current levels set via the keyboard are displayed on a separate 0.3 4 digit display. This entry preview system ensures that the user can observe the value entered before it is effected thus avoiding possible error. The display is also used for setting additional functions and for displaying watts. DIGITAL INTERFACES - TSX-P Operational Functions: RS232: GPIB (Optional): USB Interface: LAN Interface: Setting resolution: Setting accuracy: Readback resolution: Readback accuracy: Operating software: RESPONSE TIMES: Remote Command Processing Time: Power Supply: Set voltage, set current, set OVP; set output on/off; read output voltage; read output current; read output power. 9600 baud, 9 pin D-connector (female). Conforming with IEEE488.1 & IEEE488.2. Standard USB 2.0 hardware connection. Implemented as a Virtual COM Port. LAN Ethernet 100/10base-T hardware connection. 1.4 LXI Core 2011 Voltage - 10mV. Current - 10mA. Voltage - ±(0.1% + 10mV) Current - ±(0.2% + 20mA) Voltage - 10mV. Current - 10mA. Voltage - ±(0.2% + 1 digit) Current - ±(0.5% +1 digit) Software for operating the PSUs under GPIB or RS232 control is available including a Labwindows* driver. Typically <50ms between receiving the command terminator for a step voltage change at the instrument and the output voltage beginning to change. An internal time constant, T, (typically 22ms) governs the settling time of a step voltage increase. NOTE: Settling time to within 1% of the step change = 4.6T, to 0.1% = 6.9T, to 0.01% = 9.2T; for example, after a 10V step the output will be within 1 digit (10mV = 0.1%) of its new value in typically 150ms. For load current of 1 Amp or more, settling times for downward steps will be very similar; however, response times will be longer at low loads. Models Voltage/Current Power TSX1820 TSX1820P 18 volts/20 amps 360 watts TSX3510 TSX3510P 35volts/10 amps 350 watts Designed and built in Europe by: THURLBY THANDAR INSTRUMENTS LTD. Glebe Road, Huntingdon, Cambridgeshire, PE29 7DR, United Kingdom Tel: +44 1480 412451 Fax: +44 1480 450409 Email: info@aimtti.com Web: www.aimtti.com Brochure Part No. 82100-0044 Issue 1