Basic In-Line Metered Metered Input. Metered Outlet Switched Managed. Power distribution for IT equipment. epdu. G3 Platform. New

Similar documents
Product Brochure. Eaton epdu G3 Managed

Product Brochure. Eaton epdu G3 Managed

Intelligent Power Distribution

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

Intelligent Power Distribution

Infrastructure with intelligence

Intelligent infrastructure monitoring for software-defined data centers. Intelligent Power Manager Infrastructure Simplified IT-centric monitoring

Manage power your way

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

Intelligent Power Distribution

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Polar PDUs POWER MANAGEMENT

Eaton 3ph UPS technologies Modularity and resiliency. Eaton s modular UPS for maximum resiliency

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

Engineering and Manufacturing Excellence in Data Centre Infrastructure

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

ipdu Pocket Guide INTERNATIONAL

Power Monitoring in the Data Centre

PDU - Overview / Non-Intelligent PDU s

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

PDU Inspired by Your Data Center. W IEC PDU Series

AFDD+- arc fault detection device application guide

Eaton Open Data Centre Solutions. Kari Koli

ipdu Pocket Guide NORTH AMERICA

Frequently Asked Questions

PDU Solutions. PDU Solutions

ECO PDU Power Distribution Unit

Managed Rack PDU MPH2 More efficient Simpler Better

Cylindrical fuse links gg/gl and am

The -3Ph extension on a product indicates a 3 Phase power product.

Switched, Outlet Level Monitoring

ECO PDU. Features. PE5220sA

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 400V

ROOM GUARD VT335. Environmental Infrastructure monitoring

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

PE8216/PE8324. Energy Intelligence Solutions

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

Geist EMEA. Geist USA. Geist APAC

Solutions Guide for Cisco UCS B and C Series Servers

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

Models. Specifications

ROOM GUARD VT335. Environmental Infrastructure monitoring

Excel Power Distribution

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

G5 PDU Installation Guide

Monitoring system LN-VT325. Environmental Infrastructure monitoring

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

ICT Infrastructure Solutions. Real power for virtualisation

VT608 / Switched PDU with 8 outlets

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

15 Ways Belden Helps Reduce Human Error to Improve Uptime

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

VT805 / Monitoring system

8-Outlet eco PDU PE6208AV

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

VT825 / Environmental Monitoring unit. Environmental Infrastructure monitoring

Features and Benefits: Power IQ DCIM Monitoring Solutions

The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips

Comprehensive Data Center Energy Management Solutions

5 GREAT REASONS to Use Colored Rack PDUs

Power IQ for econnect

B&R Enclosures. INTELLIGENT PDUs

Energy Management Solutions

Power Distribution Units for Data Centers

Product Brochure Eaton 93PR UPS kw

Power Distribution Units for Data Centers

Complete power quality solutions for server rooms and data centres. Pre-packaged data centre solutions

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

ECO PDU PE7108/PE7208

Eaton BladeUPS 12 60kW

Inspired by Your Data Center. 1-Phase Intelligent PDU US NEMA Outlet 110V

16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

ECO PDU PE5108/PE5208

ipdu Pocket Guide INTERNATIONAL

PN5212/PN5320/PN7212/PN7320

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Power Control and Distribution

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

Over IP Group. Data Centre Infrastructure Management (DCIM)

Intelligent Power Software Manage your power easily

Power Quality Solutions. Powering your FlexPod environment

Switched XPDU. 15A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Power Distribution Unit

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Help your Cisco customers defend against downtime and reduce costs

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

Enabling Business Critical Continuity for Unified Communications. Andy Liu Product Manager, Asia Pacific

Rack PDU Marketing Playbook

Transcription:

Power distribution for IT equipment Basic In-Line Metered Metered Input Metered Outlet Managed epdu G3 Platform range extension 2017/2018

Outlet grip functionality on standard IEC cable Universal Mounting Eaton s patent-pending IEC outlet grip secures plugs in place with a lever-actuated grip that s integrated into each outlet. Once the levers click into the grip position, the plugs are secured from accidental disconnect due to bumps or vibrations without the need for special power cords. Models include both rear and side button mounting system and Eaton's patented variable mounting system. Outlet switching Remotely control devices by powering on or off individual outlets. Save time and operating costs by rebooting machines from your control center without costly site visits. Sequential start up O is unlocked, + is grip engaged Make sure your servers start sequentialy to avoid in rush current and start your database before the application. Advanced LCD pixel display with hot-swap capability Eaton s new hot-swap enmc (epdu Network Management and Control) module can be replaced without the need to power down your rack. Increase uptime while enhancing serviceability and saving on unnecessary service calls. The menu-driven pixel display allows for easy setup and troubleshooting. Green LED signifies power on and red is power off to outlet Features and benefits Module being removed without removing power to the epdu One percent billing grade accuracy + - 1% Low-profile form factor: Provide zero interference into the rail space Device reboot and measurement across A and B feed When connecting multiple source input servers to an A and B feed power source, the daisy-chain capability allows you to group power supplies across the epdu. As a result, all the power supplies are controlled with a single action, which saves time rebooting servers with two to six power supplies. The power consumption is available for each device. epdu G3 provides one percent revenue-grade power monitoring for higher accuracy in department billing or colocation data centers. Effectively measure power usage to all outlets or individual outlets. Basic All technologies High 60 C operating temperature: Fully functional in high operating temperature environments, resulting in reduced cooling costs Integrated IEC outlet grips: Integrated lever-actuated grip that easily secures plugs to prevent accidental disconnect Color-coded outlet sections: Color-coded outlet sections match corresponding color-coded circuit breakers to simplify load balancing Flexible mounting options: Button mounting on rear & side + variable mounting system Typical server with multiple power inputs powered by two epdus Daisy chain eight units from one IP address Eaton s new patented daisy-chain capability allows up to eight epdus to share the same network connection and IP address. Unlike competitive rack PDUs that require a dedicated IP address for best performance, Eaton technology provides a 87% percent reduction in network infrastructure costs. Standard All technologies except Basic One percent billing grade accuracy: Revenue-grade power monitoring for higher accuracy to help optimize power utilization Remote site management: Save time from onsite visits Hot-swap meter: Remove meter without power disruption to increase uptime while enhancing serviceability Phase and section metering: Meter color-coded sections to control power utilization Advanced LCD pixel display: Allow for easy IP setup and troubleshooting Daisy chain (share network connection/ip address): Share the same network connection and IP address for up to eight rack PDUs, which will reduce network infrastructure costs Cybersecurity: The firmware is updated on regulary basis to keep the epdu cybersecurity to highest standard. Color-coded outlet sections Color-coded outlet sections match a corresponding circuit breaker to easily identify which one feeds corresponding outlets and prevent unbalanced loading that would unnecessarily trip a breaker. 1 x 8 A and B power PDU sharing a network connection via daisy chain Advanced Managed and Metered Outlet Managed and Measure power consumption at outlet level: Acquire precise data and gain detailed energy analysis to make informed decisions and assist with effectivelydeploying equipment Measure Level 3 PUE: Measuring power at the outlet level allows users to measure Level 3 Power Usage Effectiveness (PUE), which provides the possibility of transforming billing into revenue or utility discounts Outlet switching: Remotely control devices by powering on, off or rebooting individual outlets and set sequential start up across A&B feed Group reboot for A and B feed: Group multiple power supplies across the rack PDU to control all with a single action, saving time when rebooting servers with two or more power supplies Turn off unused outlets: Control unauthorized use

Make more effective management decisions with intelligent power, space and environmental condition monitoring. IPM Infrastructure helps to bridge the gap between facility and IT management by providing you just enough information, when you need it and where you need it. Ensure business uptime and monitor epdus and It equipment with Intelligent Power Manager Full integration into VMware and Citrix with Intelligent Power Manager Trigger VM migration or VMware Site Recovery Manager (SRM) User configurable alerts on the epdu G3 work with Eaton s Intelligent Power Manager (IPM) software to trigger actions Trigger automatic migration of virtual servers in the event of a power failure via UPS, epdu alarm or threshold, temperature/ humidity or dry contact event Full integration in VMware interface Environmental monitoring including temperature and humidity with more functionality to follow. Simple IT asset management including business prioritization capabilities. Power chain monitoring including power kw, energy consumption (kwh), phase and circuit balancing. Trending analysis via an intuitive web interface with auditable logs and email alerts. www.eaton.eu/ipminfrastructure Detailed web-based interface on epdu G3 epdu integration into vrealize Operations Manager (coming in 2018) Intelligent Power Manager offers supervision and control through a single interface epdu and UPS Management En masse Configuration of epdu En masse Update of epdu Eaton collaborates with the leaders in converged and hyper-converged infrastructures and provide lab-validated power management solutions to ensure high uptime of IT systems and data integrity in case of power and environmental issues. VSPEX LABS VALIDATED 4 5

epdu G3 Key features & technical specification epdu G3 Accessories Range extension 2017 Also available in 1U 2U Basic features Standard features Advanced features 1 Phase 3 Phase Basic In-Line Metered Metered Input Metered Outlet Managed Built-in IEC outlet egrip retention, retains all standard IEC plugs NA Colour-coded outlet and branch circuits for simple load balancing NA 60 C Operating temperature Flexible mounting options: Button mounting on rear & side + variable mounting system Hot-Swap Control module with Advanced LCD + Optional Temp/Humidity sensor ±1% IEC Class 1 Billing Grade Accuracy for V, W, A and kwh & Cisco EnergyWise compliant Phase Metering, Circuit Breaker Current Metering and Input Metering Daisy-Chain up to 8 epdus, reduce network infratsructure costs En masse configuration and advanced action on virtual environement via Eaton Intelligent Power Manager IT Power chain monitoring & Real time Intelligence on your Data Center, via Eaton Intelligent Power Manager Infrastructure HTTPS, SSL, Telnet, FTP, SNMP, SMTP, DHCP, LDAP, RADIUS, DHCP 66/67 for Mass Configuration Circuit Breaker Status Monitoring Outlet and IT Equipment Metering across A and B feed Level 3 PUE measurements Turn off unused outlets to control commissioning Outlet and IT Equipment Switching/reboot /sequencing across A and B feed Input Type / Rating (A) Outlet type: Qty Breakers Nominal Power Basic p/n C14 10A C20 16A IEC60309 16A In-Line Metered & Dual p/n Metered Input p/n 8xC13 2.3kW EBAB02 443x19 x53 1U EMIH02 1Ux19''x203 12xC13 2.3kW EBAB19 443x19 x53 Metered Outlet p/n p/n 16xC13 2.3kW EBAB03 704x52x53 EMIB03 1070x52x53 EMOB03 1154x52x53 ESWB03 1154x52x53 EMAB03 1154x52x53 8xFR: 1xC19 3.7kW 1U EFLX8F* 1Ux19 x80 8xGE: 1xC19 3.7kW 1U EFLX8D* 1Ux19 x80 6xUK: 1xC19 2 single pole 3.7kW EFLX6B* 52x19 x120 12xC13: 1xC19 2 single pole 3.7kW 1U EFLX12I* 1Ux19 x80 16xC13 3.7kW EBAB21 704x52x53 8xC13 3.7kW 1U EMIH28 1Ux19''x203 1U EMOH28 1Ux19 x203 1U ESWH28 1Ux19 x203 1U EMAH28 1Ux19 x203 18xC13: 2xC19 3.7kW EMIB09 1070x52x53 20xC13: 4xC19 3.7kW EBAB22 1070x52x53 EMIB22 1070x52x53 EMOB22 1604x52x53 ESWB22 1604x52x53 EMAB22 1604x52x53 7xC13 : 1xC19 3.7kW ESWB23 704x52x65 18xC13 : 2xC19 3.7kW EMIB10 1070x52x53 20xC13 : 4xC19 3.7kW EBAB04 1070x52x53 EMIB04 1070x52x53 EMOB04 1604x52x53 ESWB04 1604x52x53 EMAB04 1604x52x53 IEC60309 3.7kW EILB13 443x52x53 2 x IEC60309 16A 2xIEC60309 3.7kW EILB24 443x65x52 IEC60309 32A 12xC13 : 4xC19 2 single pole 7,4kW EMIB06 1070x52x53 Managed p/n 2U EMIH06 2Ux19 x127 2U EMAH06 2Ux19 x225 16xC13 2 single pole 7,4kW 2U EMOH84 2Ux19 x225 2U ESWH84 2Ux19 x225 20xC13 : 4xC19 2 single pole 7.4kW EBAB05 1070x52x53 EMIB05 1154x52x53 EMOB05 1604x52x53 ESWB05 1604x52x53 EMAB05 1604x52x53 28xC13 : 4xC19 2 single pole 7.4kW EMOB71 1829x52x53 EMAB71 1829x52x53 36xC13 : 6xC19 2 single pole 7.4kW EBAB08 1604x52x53 EMIB08 1604x52x53 IEC60309 7.4kW EILB14 443x52x53 2 x IEC60309 32A 2xIEC60309 7.4kW EILB25 443x65x52 IEC60309 16A IEC60309 32A 21xC13 : 3xC19 11kW EBAB20 1070x52x53 EMIB20 1070x52x53 EMOB20 1604x52x53 ESWB20 1604x52x53 EMAB20 1604x52x53 36xC13 : 6xC19 11kW EBAB00 1604x52x53 EMIB00 1829x52x53 6xC19 6 single pole 22kW EBAB11 704x52x53 EMIB11 1070x52x53 1U EBAH11 1Ux19 x203 3xC13 : 6xC19 6 single pole 22kW EBAB01 704x52x53 6xC13 : 12xC19 6 single pole 22kW EMIB07 1604x52x53 18xC13 : 6xC19 6 single pole 22kW EMOB33 1829x52x65 EMAB33 1829x52x65 12xC13 : 12xC19 6 single pole 22kW EMIB12 1604x52x53 EMAB12 1829x52x65 24xC13 : 6xC19 6 single pole 22kW EBAB32 1154x52x53 EMIB32 1604x52x53 30xC13 : 12xC19 6 single pole 22kW EMIB34 1829x52x65 IEC60309 22kW EILB15 443x52x53 2 x IEC60309 33A 2xIEC60309 22kW EILB26 443x65x52 * Basic G3 features not applicable for the FlexPDU range Need Something Special? We make your custom epdus, please contact your local reseller. All standard epdus come with 3m cable Standard models above are stocked in Europe. Accessories Part Number Benefits Sensor EMP001 Get live measurement on temperature, humidity, set threshold and be notified in real time Adaptor Fast Ethernet Gigabit epdu to UPS cables Water leak detector* Door contact sensor* Intelligent Power Manager GBCONV CBLOUT32 CBL2OUT32 WLD012 DCS001 IPM Basic, Silver, Gold Quick and easy way to upgrade your 10/100 Mb network interface G3 epdu to Gigabit speed Connect an epdu 32A input to the hardwire output UPS Detect floods and water leaks Monitor your rack access Monitor and managed multiple epdus Trigger actions from epdus & sensor events *Door contact sensor and water leak detector can be connected through EMP001 dry contacts GBCONV WLD012* EMP001 CBL2OUT32 DCS001* CBLOUT32 All epdu G3 come with a 2 years warranty as standard. Warranty extension up to 3 years (Warranty+) and 5 years (Warranty 5) available Rack PDU Selector rackpduselector.eaton.com/gb From, input plugs to form factors and measurement features, Eaton s Rack PDU selector tool can help you find the right solution for your specific IT needs. Eaton epdu Basic G3 has a compliant environmental declaration 6 7

Need Something Special? Dedicated engineering teams in 3 centres of excellence are available to create your perfect epdu Specific configurations or complete engineering projects Including national socket types, UK, French, Din/Schuko including combinations of up to 3 types of outlet on an epdu Colored epdus now available for the entire range, to easily identify your power source Rack PDU selector www.eaton.eu/epdug3 Eaton EMEA Headquarters Route de la Longeraie 7 1110 Morges, Switzerland Eaton.eu Changes to the products, to the information contained in this document, and to prices are reserved; so are errors and omissions. Only order confirmations and technical documentation by Eaton is binding. Photos and pictures also do not warrant a specific layout or functionality. Their use in whatever form is subject to prior approval by Eaton. The same applies to Trademarks (especially Eaton, Moeller, and Cutler-Hammer). The Terms and Conditions of Eaton apply, as referenced on Eaton Internet pages and Eaton order confirmations. 2017 Eaton All Rights Reserved Printed in Europe Publication No. BR155016EN November 2017 Eaton is a registered trademark. All other trademarks are property of their respective owners. Follow us on social media to get the latest product and support information.