POSITION MONITOR USERS MANUAL POM-M2 / POM-M3. Content

Similar documents
dametric RMS EX1 VAL / SKC REFINER MONITOR SYSTEM EX EXPANDABLE RACK USERS MANUAL RMS-EX1 EN.docx July 31, 2014 / BL 1(16)

Displays Transducers. Displays and transducers

PHOENIX CONTACT Features

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

PC2004 PRESSURE CONTROLLER

PSC600-series DC/DC W

SX90 Process Controller

02/11/2015

UNIVERSAL CURRENT CONVERTER

Process displays For current and voltage

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Power Amplifiers for PVH-EDC Pumps

1 open / 1 close, 240 V ac / 2 A. < 70 ma < 65 ma ac 20 Hz 13 Hz dc 72 Hz 25 Hz

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

PSC-AC. PSC AC-series W 1 to 3 Outputs. AC-DC Power supply. Input Voltage ranges. Single output ratings. 2-3 outputs ratings

E-STOP relays, safety gate monitors

AirTest Model CN9000 Series Sensor Controller

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

RK-A CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

Installation / Control Technique

SSR - Supplies - Relays

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Repeater Relay Output, Termination Board Models D6032S, D6032D

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

Data sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

PGR-3200 MANUAL INSULATION MONITOR

RCMB20/RCMB Series

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Process Indicator Controller (Digital) (Product code 3.1 to 3.15)

3500/53 Electronic Overspeed Detection System

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Vital. Safety controller. Approvals: Control of: Features: Entire safety system based on the dynamic safety circuit.

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

CONTROL MICROSYSTEMS and 5402 Digital I/O Module. Hardware Manual

PGR-6100 MANUAL GROUND-FAULT & INSULATION MONITOR

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Electronic monitoring relays PMDsrange

SKF Machine Condition Transmitters (MCT) Series

Analog Output Module Installation Instructions

Typical Input current at 1.15A 0.65A 60 Watt 24VDC / 2.5A. 1.84A 1.0A 120 Watt 24VDC / 5.0A

Magnetically Actuated Safety Interlock Switches

Safety Monitoring Relays

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

IK4A (with ONDA technology)

CANBUS Connector Rx and Tx LED to indicate that communication is active Closed circuit terminal (Term) LAN serial port connector

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

RK-4 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH THREADED HEAD

Classification Enclosure rating Input voltage Type of

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

the Interactive Catalog

Manual Control Unit GFC 32

PLC-RSC- 24DC/21 Order No.:

AC/DC and DC/DC Converters

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Magnetically Actuated Safety Interlock Switches

Intrinsically Safe Barriers

LAUREL ELECTRONICS, INC.

Zelio Control-modular measurement and control relays 1

CONTROL MICROSYSTEMS and 5407 Relay Output Module. Hardware Manual

Tempco Instruction Manual

Cardkey S300 Enclosures

Safe monitoring relays

Z-LINE Z201 Z-L LINE. AC Current. to DC ma/v isolator/converter CONVERTERS AND INTERFACES. Electric parameters conv verters

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Operating Instructions. For. Level Control Module. Model SSR 1000

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Analog Modules AS-i, IP67, M12

Faults on the system Proximity switch connection technology:

Dold BH5928 Series 2-Channel Emergency Stop and Safety Gates with Delay

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Datasheet - SLB 200-C04-1R

DINALOG A 144 x 36 A1400 Light-Strip Indicator

NMEA Expander. Operation And. Installation Manual

Safety technique. Emergency-stop monitor BH 5922, BL 5922 safemaster

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Accessories Analogue Signal Conditioning

EM2020 Selectable AC transducer A (UK)

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

2001VT Temp & CO 2. - air quality sensor/controller NOTE!!! Manual for Installation. General. SenseAir AB

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Peak/Valley Hold Unit (PVHU) User Manual V3.00

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Solid State Remote Power Controller E /627

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

Transcription:

POM-M2 POM-M3 POSITION MONITOR USERS MANUAL Content 1 TECHNICAL SPECIFICATION... 2 2 DESCRIPTION... 2 3 HANDLING... 3 3.1 Calibration... 3 3.2 Limit setting... 3 4 CONNECTION... 4 4.1 K1 Power supply... 4 4.2 K2 Alarm outputs... 4 4.3 K3 Transducer, signal output, ground... 4 4.4 K3 Reversed indication... 5 5 TROUBLE SHOOTING... 5 6 MANUFACTURER... 5 POM-M2-M3 EN.docx March 1, 2011 / BL 1(5)

1 TECHNICAL SPECIFICATION Article number: Dametric Metso POM-M2 POM-M2 VAL0223544 POM-M2 POM-M3 VAL0308988 Power supply: POM-M2 115 or 230 VAC, +5%/-10%, 48-62 Hz POM-M3 24 VDC, ±10% Power consumption: Max. 20 VA Power fuse: PTC resistors in serial with live and neutral Temperature limit: 0 to +70 C Enclosure: Polycarbonate box, aluminum front, width =150, height =75, depth = 110 Sealing: IP20 Mounting: DIN-rail or two 4-mm screws Weight: 0.9 kg Transducer: POT-50 (VAL0103227 / SKC9069808) Cable: Front display: Signal output: Alarm limit 1,2: Alarm output 1,2: Connection: CE-approval K-POT25 (VAL0122963 / SKC9069815) Led ramp, scaled 0-50 mm, 2.50 mm/s per led, indicating the measured position or the alarm limit levels Led, yellow indicating active alarm limit output s Led, green, indicating power on Galvanically isolated analogue current signal, 4-20 ma, low pass filtered to 1Hz, max 800Ω load Adjustable, 0 to 50 mm, single turn potentiometers 1-pole toggling relay contact, max. 230 VAC, 1A, 100VA Detachable screw connectors EN50081-2:1993, EN50082-2:1995, 89/336/EEC. 2 DESCRIPTION The POM-M2/M3 monitors are used together with a position transducer to measure and indicate the axial position of the rotor or the stator in a pulp refiner. The position transducer, POT-50 is mounted on the refiner and fed with a sinusoidal signal from the POM-M2. The secondary transformer windings of the transducer respond with two signals where the amplitude ratio is proportional to the position of the sensor. The monitor then converts the signals to a standard industrial current signal of 4-20mA. The signal current output is galvanically isolated from the ground and from the measuring circuits. The monitor also includes a bar graph display which consists of a 20 segment LED's and normally indicates the vibration signal level. A transducer check circuit which detects open-loop and short-circuit input. Any fault deactivates the limit outputs and generates a 0 % signal amplitude both on the display and the current output. Two limit circuits, which compares the signal to two limit values. The limit values are adjustable between 0 and 50 mm. Each limit-output is active when the signal is lower than the adjusted limit value, and is indicated by the front panel LED s. A not active output initiates a hysteresis on the falling slope of the signal. The output drives a toggling relay contact. Each limit circuit has a pushbutton and if any of these are pressed, the corresponding alarm limit level is displayed on the bar graph display. The POM-M2 includes an AC/DC power unit, which converts and isolates the 115/230 VAC power supply to the internal +12V and -12V DC-voltages. The POM-M3 is powered from a 24VDC source and includes a DC/DC converter for the internal supplies. The unit works together with the POT-50 position transducer and the cable K-POT25. POM-M2-M3 EN.docx March 1, 2011 / BL 2(5)

3 HANDLING The 20 bar graph display indicates the position or the alarm limit levels. 3.1 Calibration General The POT-50 transducer has to be calibrated together with the POM- M2/POM-M3 monitor unit. The transducer must be removed from the holder on the refiner stand to be able to use the full mechanical stroke length. First the tip is pushed in to fully inner position for the zero calibration and then the tip is released so it returns to the fully outer position for the span calibration. Connect a DVM between the K3/11 (+) and the K3/12 (-) connector. Zero calibration Push the tip to fully inner position and hold it there. Adjust the Zero potentiometer until the DVM reading is 0.00 ± 0.001Vdc. Span calibration Release the tip so it returns to the fully outer position. Adjust the Span potentiometer until the DVM reading is 5.00 ± 0.001Vdc. 3.2 Limit setting General. Push the switch to view the limit level on the bar graph display and adjust the corresponding potentiometer to a chosen limit level. For better accuracy, measure the voltage between K3/11 and K3/12 which will indicate the limit level when the pushbutton is activated. 0.00V = 0.00mm, 5.00 V = 50.00 mm. The yellow led-diode is lit when the signal level is lower than the limit level. If both limits are used, this limit level is normally adjusted to a higher level than limit 1. Limit 1 Push the Limit 1 pushbutton and hold it there. Adjust the Limit 1 potentiometer until a chosen value on the DVM. Limit 2 Push the Limit 2 pushbutton and hold it there. Adjust the Limit 2 potentiometer until a chosen value on the DVM. Power supply This green led is lit when the unit is powered. Limit 1 Limit 2 Dametric Zero Span Transducer Calibration 0 5 10 15 20 25 30 35 40 45 50 Position (mm) POM-M2 On POM-M2-M3 EN.docx March 1, 2011 / BL 3(5)

- - POM-M2 / POM-M3 4 CONNECTION The cables are connected to the detachable screw connectors at the bottom of the unit. 4.1 K1 Power supply POM-M2: 115 VAC Mains Voltage Live K1/1 Neutral K1/6 Jumper K1/2 to K1/3, K1/4 to K1/5 230 VAC Mains Voltage Live K1/1 Neutral K1/6 Jumper K1/3 to K1/4 POM-M3: 24VDC Mains Voltage Plus K1/1 Minus K1/4 Jumper none 115VAC 230VAC Mains supply input Limit 1 Relay output Limit 2 Relay output 24VDC Limit 1 Limit 2 Mains supply input Relay Relay output output white brown green yellow grey rose + Voltage out Transducer Signal cable output 4-20mA POM-M2 VAL0223544 white brown green yellow grey rose + Voltage out Transducer Signal cable output 4-20mA POM-M3 VAL0308988 ground ground 4.2 K2 Alarm outputs Function normally normally closed open common Limit 1 K2/1 K2/2 K2/3 Limit 2 K2/4 K2/5 K2/6 Explanation. The above describes the state of a not active output. When the output is active (the led is on and the vibration level is lower than the limit level) the normally open contact is closed to the common contact. 4.3 K3 Transducer, signal output, ground Transducer signals K-POT25: K3/1 Transducer white K3/2 Transducer brown K3/3 Transducer green K3/4 Transducer yellow K3/5 Transducer gray K3/6 Transducer rose K3/7 Transducer outer cable (isolate the inner ) Signal output K3/8 + 4-20 ma current output K3/9-4-20 ma current output K3/10 Cable K3/11 Voltage output, 0-5V for calibration and limit setting Ground K3/12 Connect this pin direct to the protective ground close to the unit. Use a copper wire with an area of 2.5 mm 2 POM-M2-M3 EN.docx March 1, 2011 / BL 4(5)

4.4 K3 Reversed indication For refiner system with reversed indication of the transducer (50.00 mm when pushed fully in), use the following connection of the white and brown cable to the connector. Transducer signals K-POT25: K3/1 Transducer brown K3/2 Transducer white 5 TROUBLE SHOOTING Symptom Possible failure Action The ON led is not lit No power attached Check the main supply voltage at K1. Check the main supply jumper at K1. If the supply and jumpers are correct, the unit is defective. Note. The unit is protected against over voltage by PTC-resistors. If these are activated, the mains power supply must be shut off for at least 2 minutes. The LED ramp is constantly indicating 0 mm Transducer fault or cable fault Is the cable connected to the transducer? Check the transducer and the cable. 6 MANUFACTURER Dametric AB Jägerhorns Väg 19 SE-141 75 Kungens Kurva Sweden dametric Telephone +46-8 556 477 00 Telefax +46-8 556 477 29 E-mail info@dametric.se Internet www.dametric.se POM-M2-M3 EN.docx March 1, 2011 / BL 5(5)