HERZ Actuator 7708, 7990

Similar documents
Actuator ABNM A5 LOG/LIN for AB-QM, 0-10 V Proportional

ABB i-bus KNX Thermoelectric Valve Drive, 230 V TSA/K 230.2, 2CDG R0011

Supplementary operating instructions for your air curtain system Controller TMC 500

Room Temperature Controller

Room Temperature Controller

Electrical actuators

Room Temperature Controllers

Products no longer available

Electromotoric actuators

Proximity sensors SME-8, for T-slot Technical data Magnetic reed

Electromotoric actuators

Immersion Temperature Sensors

Electrical Actuators

Heating Circuit Controller

Electrical Actuators

Semi flush-mounted room temperature controllers with LCD

Semi flush-mounted room temperature controllers with LCD

Electromotoric actuators

Control system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

Heating Circuit Controller

OEM Product Program. Valve Drives and Room-by-Room Temperature Control. English.

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

Products no longer available

Room Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor

Overview of types. Technical data

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

RVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting

Surface-mounting Thermostats AM Series with 1 or 2 single-pole snap-action switches IP40 protection

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

PSR DC/ESP4/2X1/1X2

Contact protection relay

Electromotoric actuators

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

Operating Instructions. For. Level Control Module. Model SSR 1000

Datasheet - SRB 402EM-24V

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

AIAS. Technical description

Electromotive actuators for combi valves

Hyamaster r SPS. Intelligent single and multiple pump control system with continuous speed control by frequency inverter, with PLC SIMATIC r S7

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

PLC-RSC- 24DC/21 Order No.:

More than safety. Joystick Switches

LED Driver Linear / area fixed output

LED Driver Linear / area fixed output

MINI-PS AC/10-15DC/8

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

3RG7 Opto-BERO Photoelectric Proximity Switches

OEM. Room unit QAA822 with2- wire interface. Building Technologies CLIMATIX TM. For use with Climatix controllers

Electrical Actuators

Electromotoric actuator

PLC-OPT-230UC/ 24DC/2

Product data sheet accessories control and regulation Accessories AIRWIN

PSR UC/ESAM4/3X1/1X2/B

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ALPHA SIMBOX Small Distribution Boards

PLC-RSC- 24UC/21. Extract from the online catalog. Order No.:

LED Driver Linear / area fixed output

Room controller STRA-17

Compact Universal Controllers

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

Electronic timer CT-AHD.22

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Electronic timer CT-ERD.12

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

VAL-CP-1S-175. Extract from the online catalog. Order No.:

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

ETD-BL-1T-OFF-CC- 10S

Non-communicating room controllers

Online data sheet TBS-1BSGT3506FM TBS TEMPERATURE SENSORS

4-step Chiller and Heat Pump Controller

CI-tronic Reversing contactor Type RCI

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

JUMO Quantum PID100/PID200/PID300

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

PHOENIX CONTACT Features

MCX08M2 Programmable controller

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

LED Driver Linear / area fixed output

Product and functional description

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

SSR - Supplies - Relays

Installation / Control Technique

7-day room temperature controller

Safety switches for hinged doors

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

Operating and mounting instructions

Power supply module, bus connection module

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

Power Electronics. Semiconductor relay / - contactor

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

MINI MCR-SL-UI-REL(-SP)

Transcription:

HERZ Actuator 7708, 7990 Data sheet for 7708, 7990 Issue 1116 Dimensions Dimensions Installation height Dimensions Installation height Dimensions Installation height Page 1

Models HERZ Actuator 2-point, M28 x 1.5, 230 V, 50 Hz normally open, closing force 100 N, operating voltage 230 V ~, threaded connection M28 x 1.5, red adapter 1 7708 90 is included, max. stroke 5 mm HERZ Actuator 2-point with end switch, M28 x 1.5, 230 V, 50 Hz normally closed, closing force 100 N, operating voltage 230 V ~, threaded connection M28 x 1.5, red adapter 1 7708 90 is included, max. stroke 5 mm HERZ Actuator 2-point, M28 x 1.5, 24 V, 50 Hz normally closed, closing force 100 N, operating voltage 24 V ~, threaded connection M28 x 1.5, red adapter 1 7708 90 is included, max. stroke 5 mm HERZ Actuator 2-point, M28 x 1.5, 230 V, 50 Hz normally closed, closing force 100 N, operating voltage 230 V ~, threaded connection M28 x 1.5, red adapter 1 7708 90 is included, max. stroke 5 mm HERZ Actuator modulating 0..10 V, M28 x 1.5, 24 V, 50 Hz normally closed, closing force 100 N, operating voltage 24 V ~, threaded connection M28 x 1.5, blue adapter 1 7708 85 is included, max. stroke 5 mm HERZ Actuator modulating 0..10 V, M28 x 1.5, 24 V, 50 Hz normally closed, closing force 125 N, operating voltage 24 V ~, threaded connection M28 x 1.5, blue adapter 1 7708 85 is included, with valve path recognition, max. stroke 6,5 mm Application The HERZ-Actuator 230 V with end switch is a thermoelectric valve drive for opening and closing valves and small valves used in the scope of HVAC technology. The integrated micro switch with floating contact allows direct operation of a pump or fan control unit. The HERZ Actuator 230 V with end switch is controlled by a 230 V room thermostat with twopoint output or pulse-width modulation. Application,, The HERZ-Actuator 230 V / 24 V is a thermoelectric valve drive for opening and closing valves on heating circuit distributors of concealed floor heating and cooling systems. The main field of application is the energy-efficient individual room temperature control in the range of building management systems and home automation. The HERZ-Actuator 230 V / 24 V is controlled by a 230 V / 24 V room thermostat with two point output or pulse-width modulation. Application, The HERZ-Actuator 2-point, Proportional 5/6,5 mm is a thermoelectric actuator for the control of heating and cooling systems in direct proportion to the applied control voltage. The control of the actuators is performed by a 0-10 V DC signal via a central DDC system or by a room thermostat. The principal area of application is the building management system range. Furthermore, the variant with valve path recognition automatically registers the valve path for an optimum use of the active control voltage range. This guarantees an even more precise control of all valves. Operation The actuating drive is switched on via an electrical contact, e.g. from a room thermostat, and starts opening or closing the thermostatic valve. The actuating movement is accomplished by an electrically-heated expansion element. When the heating current is switched off, the valve closes or opens respectively. The HERZ actuating drive is maintenance-free and offers silent operation. First-Open -Function HERZ-actuators are delivered in a normally open state. By means of this feature it is possible to have the heating or cooling system operating even before an electrical wiring stage is completed. On first use an operating voltage must be applied for longer than six minutes to the actuator, then it will be unlocked and ready-for-use. Once the First-Open -function has been activated a bigger force is required to mount the actuator. Emergency function With factory setting normally closed the valve can be opened by removing the drive in case of a power failure. Page 2

Installation,,, The wide selection of valve adapters guarantees a perfect match of the HERZ-Actuator to almost any valve insert or manifold available on the market. Simply snap-on the HERZ-Actuator to the manually pre-installed valve adapter. First the valve adapter is screwed on the valve manually. The HERZ-Acutator is placed vertically on the valve adapter. The HERZ-Actuator snaps onto the valve adapter with a click when pressed down vertically by hand. Installation, The valve adapter assortment guarantees a perfect match of the actuator to almost all valve inserts and heating circuit distributors available on the market. The HERZ ActuatorProportional is simply plugged on to the valve adapter previously installed manually. Screw the adapter manually onto the valve. Connect the line to the actuator. Position the HERZ Actuator manually in vertical position to the valve adapter. Latch the HERZ Actuator to the valve adapter by manually applied vertical pressure; this can be done noiselessly and without any problems. Installation position The HERZ-Actuator must be installed preferably in vertical or horizontal installation position. For upside down installation special circumstances (e. g. drainwater) can reduce the lifetime of the actuator. Vertical Horizontal Upside down Page 3

Technical data, Operating voltage 230 V AC, +10%... 10%, 50/60 Hz Max. start up current < 550 ma during 100 ms max. Operating power 1 W 1) Stroke (actuator travel) 5.0 mm Actuating force 100 N ±5% Fluid temperature 0 to +100 C 2) Storage temperature -25 C to +60 C Ambient temperature 0 to +60 C Type of protection IP 54 3) / II CE conformity according to EN 60730 Housing material/housing colour Polyamide / light grey (RAL 7035) Connecting cable/colour 2 x 0.75 mm 2 PVC / light grey (RAL 7035) Cable length 1 m Weight with connecting cable (1 meter) 100 g Surge protection according to EN 60730-1 min. 2.5 kv 1) measured with precision reference instrument LMG95-2) in dependence of the adapter even higher - 3) in all installation positions Technical data Operating voltage 24 V AC/DC, +20%...-10% Max. start up current < 300 ma during 2 min. max. Operating power 1 W 1) Stroke (actuator travel) 5.0 mm Actuating force 100 N ±5% Fluid temperature 0 to +100 C 2) Storage temperature 25 C to +60 C Ambient temperature 0 to +60 C Type of protection IP 54 3) / III CE conformity according to EN 60730 Housing material/housing colour Polyamide / light grey (RAL 7035) Connecting cable/colour 2 x 0.75 mm 2 PVC / light grey (RAL 7035) Cable length 1 m Weight with connecting cable (1 meter) 100 g Surge protection according to EN 60730-1 min. 2.5 kv 1) measured with precision reference instrument LMG95-2) in dependence of the adapter even higher - 3) in all installation positions Technical data Operating voltage 230 V AC, -10%...+10%, 50/60 Hz Max. start up current < 550 ma during max. 100 ms Operating power 1 W 1) Stroke (actuator travel) 5.0 mm Actuating force 100 N ±5% Switching current for micro switch 230 V AC: 5 A resistive load, 1 A inductive load Switching point of micro switch NC approx. 2 mm Fluid temperature 0 - +100 C 2) Storage temperature -25 C to +60 C Ambient temperature 0 to +60 C Degree / class of protection IP 54 3) / II CE conformity according to EN 60730 Casing material / colour Polyamide / light grey (RAL 7035) Connection line / colour 4 x 0.75 mm² PVC / light gray (RAL 7035) Cable length 1 m Weight with connecting cable (1 m) approx. 150 g Surge protection according to EN 60730-1 min. 2.5 kv 1) measured with precision reference instrument LMG95-2) in dependence of the adapter even higher - 3) in all installation positions Page 4

Technical data, Voltage 24 V AC, -20 %... +20 % Control voltage range 0 V 10 V DC Max. start up current < 300 ma for max. 2 Min. Operating power 1. W 1) () / 1,2 W 1) () Resistance of control voltage input 100 kω Stroke 5 mm () / 6.5 mm () Actuating force 100 N ±5% () / 125 N ±5% () Fluid temperature 0 to +100 C 2) Storage temperature -25 C to +65 C Ambient temperature 0 to +60 C Degree / class of protection IP 54 3) / III CE conformity according to EN 60730 Casing material / colour Polyamid / white Connection line / colour 3 x 0.22 mm² PVC / white 1) measured with precision reference instrument LMG95-2) in dependence of the adapter even higher - 3) in all installation positions Room thermostat Standard room thermostats equipped with a thermal feedback loop can be used for piloting the HERZ actuating drive. If required, several drives can be connected in parallel taking the maximum admissible electrical load of the switch contact into account. Design and planning notes When selecting the switch contacts and mains fuses, the start up current of the heating element must be taken into account. The voltage loss in the electric lines must not exceed 10 %, ensuring that the indicated runtime is guaranteed. Max. cable length for an actuating drive with given cable cross-sections (information with voltage drop approx. 5 %; at 230 V voltage drop is 10 V, at 24 V voltage drop is 1 V). When using several actuating drives, the indicated cable length must be divided by the number of actuating drives connected. Cable cross-section (mm 2 ) 230 V, max. length (m) 24 V, max. length (m) 2 x 0.75 1500 168 2 x 1.0 2000 224 2 x 1.5 3000 340 2 x 2.5 5000 560 Resistance values Please refer to the HERZ standard diagrams contained in the relevant standard sheets with regard to resistance values when operating HERZ valves with HERZ actuating drives. The curves "Valve fully open" or "max." apply. Accessory 1 7796 04 HERZ Transformer 230/24 V The overload-proof HERZ safety transformer 230/24 V is designed for the connection of HERZ room thermostats and HERZ actuating drives and suitable for operation of 8 HERZ actuating drives max. Version as per VDE 0551 Protection class II Protection class IP 20 ISO Cl. T40/E Input voltage 230 V Fuse in input circuit 50-60 Hz, 315 ma Output voltage 24 V Power 50 VA Quick installation on device rail ref. DIN 42227/3 Dimensions 106 x 90 x 74 mm (B x H x T) Page 5

1 7791 23 HERZ Electronic room temperature controller for 2-point or pulse control with timer For individual control with programmable times and temperatures. Timer with weekly and annual programs, automatic switchover from summer to winter time. Setpoint range 8 38 C Switching differential as 2-point controller 0.4 8 K Measurement accuracy 0.3 K at 20 C Operating voltage 230 V 1 7790 15 HERZ Electronic room temperature controller for 2-point control 1 switchover contact Setpoint range 10 30 C Switching differential +/-0.2 K fixed Operating voltage 230 V 1 7790 25 HERZ Electronic room temperature controller for 2-point control 1 switchover contact Setpoint range 10 30 C Switching differential +/-0.2 K fixed Operating voltage 24 V 1 7940 62 HERZ-RTC-2 Room Temperature Computer With 3 weekly programmes, 4 temperature steps, vacation programme for heating and cooling, switching difference adjusting. Set value range 5 40 C, operating voltage 24 V, output voltage 0 10 V. Electromechanical Room Temperature Controller 1 change-over contact, set value range 5-30 C. Adjustment of set value by means of mechanical limitation of set value range Adapter for Motor Valve Drives Analog 3 F799 11 Heating, temperature set-back, frost protection, 230 V~ 3 F799 12 Heating, temperature set-back, frost protection, 24 V~ 3 F799 13 Heating/ cooling, temperature set-back, frost protection and valve protection function, cooling lock, 230 V~ 3 F799 14 Heating/ cooling, temperature set-back, frost protection and valve protection function, cooling lock, 24 V~ Digital 3 F799 15 Heating, temperature set-back, frost protection, 230 V~ 3 F799 16 Heating, temperature set-back, frost protection, 24 V~ 3 F799 17 Heating/ cooling, temperature set-back, frost protection and valve protection function, cooling lock, 230 V~ 3 F799 18 Heating/ cooling, temperature set-back, frost protection and valve protection function, cooling lock, 24 V~ 1 7708 90 Colour red, adapter M28 x 1,5 for the use with HERZ- heating circuit distributor and HERZ valves (incl. 4002, 4006 and 7217-GV) in combination with 2-point-actuators. 1 7708 85 Colour blue, adapter M28 x 1,5 for HERZ 4002, 4006 and 7217 GV in combination continuous actuators 1 7990 3x and 1 7990 4x Colour light gray, adapter for the use with: Oventrop thermostatic valves and distributors made 1 7708 86 of stainless steel, Oventrop Cocon, Cocon4, Viega distributors made of stainless steel, T&A, TBV-CM, TBV-CMP 1 7708 80 Adapter M 28 x 1,5 for HERZ-actuating drive, colour grey for the use with 7217-98-V, 7217-99-V 1 7708 98 Adapter M 30 x 1,5 for the use with HERZ Ventilen with M 30 x 1,5 connection thread and regulating valves 7760, 7762 and 7763 Page 6

Adapter-Valve-Diagram TS-90-DE LUXE TS-98-V DE LUXE DE LUXE TS-3000 DE LUXE VUA Valve types TS-98-V TS-90-V TS-99-FV TS-90-KV TS-90 TS-90-E TS-E 2-Point-Regulation Adapters and actuators blue red continuous Regulation * * * * * * * * * * * * Adapter 1 7708 90 has to be ordered separately ** Adapter 1 7708 80 has to be ordered separately *** Adapter 1 7708 98 has to be ordered separately Adapter-Valve-Diagram 2-Point-Regulation TS-90 DIN TS-90-V DIN TS-98-V DIN TS-99-FV DIN Valve types TS-98-VH TS-90-H TS-98-VH TS-3000 TS-3000 *** *** *** *** TS-90 Calis-TS Adapters and actuators blue red continuous Regulation * * * * *** *** *** * *** * * * Adapter 1 7708 90 has to be ordered separately ** Adapter 1 7708 80 has to be ordered separately *** Adapter 1 7708 98 has to be ordered separately Page 7

Adapter-Valve-Diagram 2-Point-Regulation Calis- TS-E VTA-40 VTA-50 VUA- AHA Valve types VUA-40 VUA-50 4002 4006 7217 V 7217 GV 7217-98-V *** *** ** Adapters and actuators blue red continuous Regulation * * *** * * *** * ** * Adapter 1 7708 90 has to be ordered separately ** Adapter 1 7708 80 has to be ordered separately *** Adapter 1 7708 98 has to be ordered separately Adapter-Valve-Diagram 7217-99-FV 7723 Zonenventil Valve types 7760 RD 7761 RD 7760 7762 7763 2-Point-Regulation ** *** *** *** Adapters and actuators blue red continuous Regulation ** * * * *** *** *** * Adapter 1 7708 90 has to be ordered separately ** Adapter 1 7708 80 has to be ordered separately *** Adapter 1 7708 98 has to be ordered separately Page 8

Electric connections We recommend usage of the following lines for installing a 230 V system: Light plastic-sheathed cable NYM 1.5 mm² or flat webbed building wire NYIF 1.5 mm² Electric connections We recommend usage of the following lines for installing a 24 V system: Light plastic-sheathed cable NYM 1.5 mm² or flat webbed building wire NYIF 1.5 mm² Electric connections We recommend usage of the following lines for installing a 230 V system: Light plastic-sheathed cable NYM 1.5 mm² or flat webbed building wire NYIF 1.5 mm² Electric connections, Calculation of maximum cable length (copper cable) for 24 V rated voltage L = C x A / n L Cable length in m; K Constant (269 m/mm²); A Conductor crosssection in mm²; n Number of Alpha-Actuators We recommend the following cables for installing a 24 V system: Telephone line J-Y(ST)Y 0.8 mm2 Light plastic-sheathed cable: NYM 1.5 mm² Flat webbed building wire: NYIF 1.5 mm² Transformer: A safety isolating transformer according to EN 61558-2-6 must always be used. Transformer dimensioning results from the making capacity of the HERZ-Actuators. Rule-of-thumb formula: Ptransformer = 7.2 W x n n = Number of OEM Actuators Note: All diagrams are for illustrating purposes only and do not claim to be complete. All information contained in this brochure corresponds to the state of knowledge at the time of going to print and is intended for informational purposes only. We therefore reserve the right to make any changes subject to advancing technology. The images are symbolic representations only and can therefore visually deviate from the actual appearance of products. Any deviations in color are due to typography. Subject to country-specific product variants. We reserve the right to change specifications and functions without notice. Please contact your nearest HERZ subsidiary if you have any questions. Page 9