ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

Similar documents
User s Manual Pulse Encoder Interface Module OTAC-01

115/230 VAC Digital Input Module OHDI-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

Dimensional drawings. Dimensional drawings

Options for ABB drives, converters and inverters. User s manual FEA-03 F-series extension adapter

ABB Drives. User s Manual I/O Module Adapter AIMA-01

Options for ABB drives. User s manual FSE-31 pulse encoder interface module

Start-up Guide. AF 100 Adapter Kit NAFA-01

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

ABB Drives. User s Manual RS-485 Adapter Board FRSA-00

ABB industrial drives. EMC filter and ground-to-phase varistor disconnecting instructions ACS880 frames R1 to R11

Technical Manual SMART TRAC PG Card

User s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

Orientation F7 Drive Software Technical Manual

Absolute Encoders Multiturn

ABB industrial drives. Supplement ACS880 distributed I/O bus

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q950) for ACS880-07/17/37 drives

SERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS

8902/E1 Sin/Cos Speed Feedback Option

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

MODIFYING THE ACS355 UL TYPE 4X FOR MXXX OPTIONS

8902/E1 Sin/Cos Speed Feedback Option

- Alii -,..., ~~~~~~~~'-~" ..., ,..- ))) --t ..., )(1. User s manual FEPL-02 Ethernet POWERLINK adapter module. IIIIIJ!ll"

RoHS. Shock / vibration resistant. Short circuit proof. Flexible. . XXXX e. . XXXX e

TB6600 Stepper Motor Driver

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives

8902/RE Resolver Speed Feedback Option

UNIVERSAL MOTION INTERFACE (UMI) ACCESSORY

Screw. Nut Guide. Features

SINCOS. Linear Stepper Motor Power Stage. Manual 2066-A006 GB

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

User s Manual. Extremely Low Noise 3-phase Microstepping Driver. For 3L583M. Version All Rights Reserved

User Manual of 3M583

ENC-IQ58S-H-PROG-ZCW-4-06-A-L1

Resolver to Digital Expansion Board

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

PTC/PT100 board 2.0 Option

Rotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track

ENC-CKP58-H-PROG-ZCW-4-06-A-L1

CCPF-3500-XX OPERATION MANUAL. Lumina P/N

The pages in this document have been extracted from a larger document and as such any page numbers are relevant only to the original document.

SCD96 DMX Output Interface. Installation guide

RoHS. High shaft load capacity. Shock / vibration resistant

HB5M. Hollow Bore Optical Encoder Page 1 of 5. Description. Mechanical Drawing. Features

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

Faults on the system Proximity switch connection technology:

V E1B Snap-in I/O Module

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

HB5M. Hollow Bore Optical Encoder Page 1 of 6. Description. Related Products & Accessories. Features

V E62B Snap-in I/O Module

Instruction Sheet Board Style Low Water Cutoff

TSXCCY1128 electronic cam module cams - 1 axis - 7 W

SDG1400 User s Guide

270 MHz Control Modules

over time. Improper wiring practices could result in drive malfunction due to loose terminal connections. Control Circuit Terminal Block Functions Dri

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

ACS Stepper Controller. Econo Stepper Controller

SM-I/O Lite and SM-I/O Timer Solutions module for DIGIDRIVE SK and UNIDRIVE SP User guide

MTII4200 Level Transmitter Installation, Operation & Maintenance Instructions

Welcome to the safety functions configuration training module for ACS880 Cabinet-built industrial drives.

MDK. Accelnet Module DevKit. Provides Mounting & Connections for Accelnet CANopen Servoamplifiers FEATURES

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

GS202 Encoder Switch

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Options for ABB drives. User s manual FPTC-01 thermistor protection module (option +L536) for ACS880 drives

Digital encoder interface module 5/12/24 V DANGER

Integrated Stepper Drive & Motor

Model 3750 Multifunction I/O Card

V E2B Snap-in I/O Module

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

AG300 Family CTL01-3A-03, AMP01-2A-02

Options for ABB drives, converters and inverters. User s manual FECA-01 EtherCAT adapter module

EM705 2-phase Digital Stepper Drive

EM806 2-phase Digital Stepper Drive

ABB wind turbine converters. Supplement ACS slide-out frame (+P919)

EA500. Installation Instructions Transponder

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

USER S MANUAL VER.1. C10D- PARALLEL PORT INTERFACE CARD BOARD Rev. 1

MDX ENCODER MDX RESOLVER

MECHANICAL ELECTRICAL CONNECTIONS. * Index (Z) optional. See Ordering Information

Motion Controller. MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control

Installation & Operation Guide

Connection and Operation (Built-In Controller Package)

Short User s Manual ACS310. Table of contents. Safety. Mechanical installation. Electrical installation. Start-up and control with I/O

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

Datasheet-MA860 Stepper Motor Driver

VLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)

PTC/PT100 board 2.0 Option

Installation Guide Controller Series E130/E230/E430

V E5B Snap-in I/O Module

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Transcription:

ABB Drives User s Manual Pulse Encoder Interface Module MTAC-01

Pulse Encoder Interface Module MTAC-01 User s Manual 3AFE68591091 REV B EN EFFECTIVE: 04.04.2006 2006 ABB Oy. All Rights Reserved.

5 Safety Overview This chapter states the general safety instructions that must be followed when installing and operating the MTAC-01 Pulse Encoder Interface module. The material in this chapter must be studied before attempting any work on, or with, the unit. In addition to the safety instructions given below, read the complete safety instructions of the specific drive you are working on. General safety instructions WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians. The drive and adjoining equipment must be properly grounded. Do not attempt any work on a powered drive. After switching off the input power, always allow the intermediate circuit capacitors 5 minutes to discharge before working on the drive, the motor or the motor cable. It is good practice to check (with a voltage indicating instrument) that the drive is in fact discharged before beginning work. The motor cable terminals of the drive are at a dangerously high voltage when input power is applied, regardless of motor operation. There can be dangerous voltages inside the drive from external control circuits even when the drive input power is shut off. Exercise appropriate care when working on the unit. Neglecting these instructions can cause physical injury or death. Safety

6 Safety

7 Table of contents Safety....................................................... 5 Overview.................................................... 5 General safety instructions....................................... 5 Table of contents.............................................. 7 Installation................................................... 9 Preparing for installation........................................ 9 Installing the module.......................................... 10 Start-up.................................................... 20 Configuration................................................ 20 01 OPERATING DATA......................................... 20 50 ENCODER............................................... 21 19 TIMER & COUNTER........................................ 22 Diagnostics................................................. 23 Faults/Alarms................................................ 23 Technical data............................................... 24 Table of contents

8 Table of contents

9 Installation Preparing for installation MTAC-01 module The MTAC-01 Pulse Encoder Interface module is an interface for connecting a digital pulse encoder to an ACS350 drive. A pulse encoder should be used if accurate speed or position (angle) feedback from the motor shaft is required. Module layout SCR V in V out GND A B Z Compatibility The MTAC-01 module is compatible with all ACS350 drives. To confirm compatibility with a particular pulse encoder, compare the pulse encoder requirements to Specifications on page 25. Installation

10 Installing the module Delivery check The MTAC-01 module package contains: MTAC-01 module grounding stand-off panel port adapter this manual. Mounting WARNING! Follow the safety instructions given in this manual and in the ACS350 User s Manual [3AFE68462401 (English)]. To mount the MTAC-01 module: 1. If not already off, disconnect the input power from the drive. After disconnecting the input power, wait for 5 five minutes before you start working on the drive. 2. Remove the possible control panel or panel cover from the drive. 3. Remove the grounding screw in the top left corner of the drive s control panel slot and install the grounding stand-off in its place. 4. Ensure that the panel port adapter is attached to either the panel port of the drive or the mate part of the MTAC-01 module. 5. Gently and firmly install the MTAC-01 module to the drive s panel slot directly from the front. Note: Signal and power connections to the drive are automatically made through a 6-pin connector. 6. Ground the module by inserting the screw removed from the drive in the top left corner of the MTAC-01 module. Tighten the screw. Installation

11 Note: Correct insertion and tightening of the screw is essential for fulfilling the EMC requirements and proper operation of the module. 7. Install the possible control panel or panel cover on the MTAC-01 module. 3 4 6 5 Installation

12 Wiring General The pulse encoder should be connected to the MTAC-01 module with cables as specified below. 4 (2+1) twisted pair cable with Cable construction individual and overall shields Conductor cross-sectional area 0.5 to 1.5 mm 2 20 to 16 AWG Maximum cable length 100 m 330 ft Terminal designations Use the following table for reference when wiring terminals. Identification MTAC Encoder Description SCR SCR/ Used for grounding of the encoder cable shields. SCR Shield Connected internally to the drive ground. V in V cc /PWR Connected to the external power supply. V out V cc /PWR Connected to the encoder. GND 0 V / GND One connected to the ground of the external power GND supply and the other to the ground of the encoder. A 1 A A+ Max. signal frequency: 200 khz Signal levels: A 1 A A- Logic 1 Logic 0 24 V 12.1 V 8.3 V 15 V 7.5 V 5.3 V B 2 B B+ 5V 2.5V 1.9V B 2 B B- Decision levels are automatically defined based on the daisy chained power supply voltage level. Input channels are isolated from the logic and ground. Z 3 Z Z+ Z 3 Z Z- When the drive runs in the Forward direction, channel A should lead channel B by 90 (electrical). Channel Z: One pulse per revolution (used in positioning applications only). Installation

Wiring Encoder power The MTAC-01 module does not supply power for the encoder. An external power supply (as diagrammed below) is recommended. The drive s 24 VDC supply from terminals X1A:9 (+24V) and X1A:10 (GND) can be used if the total draw on the supply does not exceed 200 ma. Use the following table to determine if the drive s supply can be used. Loads using the drive s 24 VDC supply ma Number of digital inputs used x 15 ma each = (DI1 DI5) MTAC-01 = 35 Encoder current requirement = Total requirements for any other user connection(s) to drive s 24 VDC = Total (must be less than 200 ma) = 13 1. Connect as follows: Encoder 0V V cc MTAC-01 module SCR SCR V in External power supply V out GND GND V cc 0V Wiring Encoder 1. Determine the encoder wiring configuration: Refer to Phasing on page 14 to determine if the encoder has normal pulse order encoder channel A/1 pulse leads channel B/2 pulse. Refer to Encoder output types on page 15 to determine the encoder s output type. For push-pull types, refer to the manufacturer s recommendation for connection either single-ended or differential can be used. Installation

14 2. Refer to Wiring diagrams on page 16, select the appropriate diagram, and wire the encoder. Note: Normally, ground the cable shield only at the drive end. However, if the encoder is isolated from the motor and from the ground, connect the cable shields to both the MTAC module and the encoder housing. Note: Do not route the encoder cables parallel to power (e.g. motor) cables. 3. Verify correct encoder phasing. See options below. Phasing When the encoder is connected correctly, running the drive in the Forward (positive speed reference) direction should produce a positive encoder speed feedback. Option A: Oscilloscope test. On incremental encoders, the two output channels, usually marked A and B or 1 and 2, are 90 (electrical) apart from each other. When rotated clockwise, most encoders but not all have channel A/1 leading channel B/2 as illustrated below. Determine the leading channel by referring to the encoder documentation or by measuring with an oscilloscope. A or 1 A or 1 B or 2 B or 2 Z or 0 Z or 0 90 Diagrams show normal phasing: Pulse A/1 leads (i.e. rises earlier than) pulse B/2. Connect the zero reference output channel (usually marked 0, N or Z) only if parameter 5010 ZPLS ENABLE = 1 (ENABLE). The encoder output channel that leads when the drive runs Forward should be connected to MTAC terminal A. The output channel that trails should be connected to MTAC terminal B. Installation

Option B: Functional test. For this test: Temporarily, switch the drive to scalar mode [parameter 9904 MOTOR CTRL MODE = 3 (SCALAR:FREQ)], if not already there. Run the drive in the forward direction. Verify that parameter 0147 MECH REVS is increasing in the positive direction. If not, switch the A/A (or 1/1) connections. Encoder output types The following diagrams identify the typical encoder output types. Push-pull Open collector (sinking) Open emitter (sourcing) 15 V CC V CC V CC OUT R L OUT R L OUT V CC = Encoder input power supply voltage R L = Load resistor at encoder output channel Installation

16 Wiring diagrams Push-pull type encoder output Diagram assumes normal pulse order in Forward A/1 rotation: Pulse A/1 leads as diagrammed on the B/2 right. For encoders with pulse 2 leading, change the diagram for these connections: Encoder A/1 and B/2 should be wired to MTAC terminals B and A, respectively. Encoder A/1 and B/2 (if present) should be wired to MTAC terminals B and A, respectively. Differential connection MTAC-01 module SCR SCR SCR Encoder 0V V CC 1 1 2 2 0 0 V in V out GND GND A A B B Z Z Encoder power supply 1) 1) Connect the cable shield at the encoder housing, if, and only if, the encoder is isolated from the motor, and from the ground. Installation

17 Single-ended connection MTAC-01 module SCR SCR Encoder SCR 0V V CC 1 2 0 V in V out GND GND A A B B Z Z Encoder power supply 1) 1) Connect the cable shield at the encoder housing, if, and only if, the encoder is isolated from the motor, and from the ground. Installation

18 Open collector (sinking) encoder output Diagram assumes normal pulse order in Forward A/1 rotation: Pulse A/1 leads as diagrammed on the B/2 right. For encoders with pulse B/2 leading, change the diagram for these connections: Encoder A/1 and B/2 should be wired to MTAC terminals B and A, respectively. MTAC-01 module SCR SCR Encoder SCR 0V V CC 1 2 0 2) R L V in V out GND GND A A B B Z Z Encoder power supply 1) 1) Connect the cable shield at the encoder housing, if, and only if, the encoder is isolated from the motor, and from the ground. 2) Three identical resistors whose size depends on the encoder power supply V in =V out : V in = 30 V: R L = 2.7 3.0 kohm, 0.5 W V in = 24 V: R L = 1.8 2.2 kohm, 0.5 W V in = 15 V: R L = 1.0 1.5 kohm, 0.5 W V in = 5 V: R L = 390 470 ohm, 0.125 W Installation

19 Open emitter (sourcing) encoder output Diagram assumes normal pulse order in Forward A/1 rotation: Pulse A/1 leads as diagrammed on the B/2 right. For encoders with pulse B/2 leading, change the diagram for these connections: Encoder A/1 and B/2 should be wired to MTAC terminals B and A, respectively. MTAC-01 module SCR SCR Encoder SCR 0V V CC 1 2 0 2) R L V in V out GND GND A A B B Z Z Encoder power supply 1) 1) Connect the cable shield at the encoder housing, if, and only if, the encoder is isolated from the motor, and from the ground. 2) Three identical resistors whose size depends on the encoder power supply V in =V out : V in = 30 V: R L = 2.7 3.0 kohm, 0.5 W V in = 24 V: R L = 1.8 2.2 kohm, 0.5 W V in = 15 V: R L = 1.0 1.5 kohm, 0.5 W V in = 5 V: R L = 390 470 ohm, 0.125 W Apply power 1. Turn on the input power to the drive. 2. Continue with the next chapter, Start-up. Installation

20 Start-up Configuration To configure the operation of the MTAC-01 module: 1. Power up the drive. 2. Use the control panel on the drive or the DriveWindow Light PC tool and set group 50 ENCODER parameters described on page 21. Encoder operating data The following actual signals, based on measurements or calculations, provide feedback from the encoder. You cannot set these values directly, but you can use group 50 ENCODER parameters to control the mechanical angle and revolution data. No. Name/Value Description FbEq 1) 01 OPERATING DATA 0146 MECH ANGLE Calculated mechanical angle 1 = 1 0147 MECH REVS Mechanical revolutions, i.e. the motor shaft 1 = 1 revolutions calculated by the encoder 0148 Z PLS DETECTED Encoder zero pulse detector. 0 = not detected, 1 = detected 1 = 1 1) Fieldbus equivalent, scaling between the value and the integer used in serial communication. Start-up

21 Encoder parameters This group defines the set-up for encoder use: Sets the number of encoder pulses per shaft revolution. Enables the encoder operation. Defines how the mechanical angle and revolution data is reset. Index Name/ Description Selection 50 ENCODER 5001 PULSE NR States the number of encoder pulses per one revolution. Default FbEq 1) 1024 32 16384 ppr Pulse number in pulses per round (ppr) 1 = 1 5002 ENCODER Enables the encoder. DISABLE ENABLE DISABLE Disables the encoder. 0 ENABLE Enables the encoder. 1 5003 ENCODER FAULT Defines the operation of the drive if a failure is FAULT detected in communication between the pulse encoder and the pulse encoder interface module, or between the module and the drive. FAULT The drive trips on fault ENCODER ERROR. 1 ALARM The drive generates alarm ENCODER ERROR. 2 5010 Z PLS ENABLE Enables the encoder zero (Z) pulse. Zero pulse is used for position reset. DISABLE DISABLE Disables the zero pulse. 0 ENABLE Enables the zero pulse. 1 5011 POSITION Enables the position reset. DISABLE RESET DISABLE Disables the position reset. 0 ENABLE Enables the position reset. 1 1) Fieldbus equivalent, scaling between the value and the integer used in serial communication. Start-up

22 Counter Index Name/ Selection 19 TIMER & COUNTER 1906 COUNTER INPUT PLS IN(DI 5) The encoder pulses can be used as the signal source for the counter. For more information on the counter function, refer to chapter Program features in ACS350 User s Manual [3AFE68462401 (English)]. ENC W/O DIR Description Default FbEq 1) Selects the input signal source for the counter. PLS IN(DI 5) Digital input DI5 pulses. When a pulse is detected, the counter value increases by 1. Encoder pulse edges. When a rising or a falling edge is detected, the counter value increases by 1. ENC WITH DIR Encoder pulse edges. The direction of rotation is taken into account. When a rising or falling edge is detected and the direction of rotation is forward, the counter value increases by 1. When the direction of rotation is reverse, the counter value decreases by 1. 1) Fieldbus equivalent, scaling between the value and the integer used in serial communication. 1 2 3 Start-up

23 Diagnostics Faults/Alarms If the ACS350 detects that the encoder signal is lost, the drive operation and the diagnostic message are both controlled by parameter 5003 ENCODER FAULT: 5003 = 1 (FAULT) The drive generates a fault (23 ENCODER ERR), and the motor coasts to a stop. 5003 = 2 (ALARM) The drive generates an alarm (2024 ENCODER ERROR) and operates as if parameter 5002 ENCODER ENABLE = 0 (DISABLE), that is, speed feedback is derived from the internal motor model. In case of a fault or alarm signal, check for and correct the following: CODE FAULT/ALARM 1) CAUSE WHAT TO DO 0023 ENCODER ERR Communication fault Check pulse encoder and its (7301) between pulse encoder wiring, pulse encoder 0306 bit 6 and pulse encoder interface module and its interface module or wiring and parameter group 2024 ENCODER ERROR between module and 50 ENCODER settings. (7310) drive. 0309 bit 7 1) Name, code for fieldbus communication (in parentheses) and bit in fault/alarm word. Note: The validity of the encoder signal is also checked during the ID run. See parameter 9910 MOTOR ID RUN. If the drive detects an encoder problem during the ID run, the drive generates an alarm. Parameter 5003 ENCODER FAULT controls the drive s fault/alarm response to encoder errors only after the ID run is completed. Diagnostics

24 Technical data Dimensions Module dimensions are shown in the figure below. 70 [2.77] 63 [2.48] 46 [1.81] 118 [4.63] Degree of protection The degree of protection of MTAC-01 is IP20 / UL open. 3AFE68580064-A Technical data

25 Ambient conditions Temperature -10 +40 C (14 +104 F). No frost allowed. Connectors Connectors on the module: one 12-pin screw-type, non-detachable terminal block that accepts wire connectors up to 1.5 mm 2 (16 AWG) for encoder interface two RJ-45 connectors for panel pass-through 6-pin connector for drive interface grounding screw/stand-off for connection of the SCR terminals of the drive and the MTAC-01 module. Specifications Module specifications The MTAC-01 module: supports three channels: CH A, CH B, CH Z includes pass-through terminals to connect an external power supply (required) to the pulse encoder has all of its materials UL-approved. Channel specifications Channel specifications: differential or single-ended maximum input frequency: 200 khz input voltage range (measured at the MTAC module): see Terminal designations on page 12 nominal input impedance (at 24 VDC): 20 kohm isolated from the logic and ground. Technical data

26 Technical data

ABB Limited Daresbury Park Daresbury Warrington Cheshire WA4 4BT UNITED KINGDOM Telephone +44 1925 741111 Fax +44 1925 74121 3AFE68591091 REV B / EN EFFECTIVE: 04.04.2006 ABB Oy AC Drives P.O. Box 184 FI-00381 HELSINKI FINLAND Telephone +358 10 22 11 Fax +358 10 22 22681 Internet http://www.abb.com ABB Inc. Automation Technologies Drives & Motors 16250 West Glendale Drive New Berlin, WI 53151 USA Telephone 262 785-3200 800-HELP-365 Fax 262 780-5135 ABB Beijing Drive Systems Co. Ltd. No. 1, Block D, A-10 Jiuxianqiao Beilu Chaoyang District Beijing, P.R. China, 100015 Telephone +86 10 5821 7788 Fax +86 10 5821 7618 Internet http://www.abb.com