Symmetry M2100 Controller

Similar documents
T h e re is an upgrade route to larger configurations. O v e rv i e w

SYMMETRY MULTINODE M2150 INTELLIGENT CONTROLLER

multinode M2150 INTELLIGENT CONTROLLERS

Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

PRO3200 Professional Modular Access Control Hardware

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

PRO2200 Professional Modular Access Control Hardware

Quick Start Installation Guide

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

TAC I/NETTM 1284, 1280, Security Control Unit

Access Easy Control System. Reference Guide

SECURA KEY CARD ACCESS CONFIGURATION GUIDE Multi-Reader Systems with NOVA.16 (SK-MRCP) 16-Door Panel

Keyscan CA150 PoE Single Door Controller

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL

UC-2000 Installation Manual Unicorn Computers Technology Limited

SYMMETRY. Bilder-Preisliste gültig ab

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

Architectural and Engineering Specification. Brivo ACS 5000 Control Panels and ACS Service

NetGen Hardware Installation Guide. for NetGen Ethernet Door Controllers

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

Control Panel Solutions

AC-825IP Networked Controller Hardware Installation and User Guide

VICON ACCESS CONTROL CONTROLLERS

CardaxFT Reader I/O Interface

MR51e Reader Interface

PRT-RDS2 Standard 2 Reader Expander

TDSi MICROgarde type door controllers offer a fully featured door controller with up to 25,000 card memory.

CN8000. Features. KVM on the NET

EP-ELVCTL Elevator Control (NION-16C48M)

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

CA111x-series Arming Station

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

ACS-8-System. Access Control. Performance features at a glance

Installation Instructions

T E C H N I C A L F E A T U R E S

Simple & Easy Installation

IQ Series Architect/Engineer Guide Specification P/N Revision 5.0

SYSTEM GALAXY HARDWARE. 635-Series

Suprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use

EP1501 Intelligent Controller

MRC350 Card Capture Reader

Pegasus Equipments Export Limited. Local Contact:

Bewator Granta Controller Installation Handbook

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Corporate Commitment to Excellence

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

SmartLock Controller INSTALLATION MANUAL

MaCaPS International Ltd

6222 Two Door Module Technical Operations Manual

MTGW. Installation Guide. CAN-RS-485 BUS Gateway

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

Access Easy Controller V 1.0

INTERFACES TRADITIONAL PC ADAPTER CARD. DATA SHEET page 1/6. Description

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

Product Datasheet NK8237 Modbus Gateway for Sinteso/Cerberus PRO, and STT20 fire detection systems

ACS-8-System. Access Control. Performance features at a glance

NGC-40-BRIDGE. Control and Monitoring Modules for use with the nvent Raychem NGC-40 System Installation Instructions

Two Door Controller GEN-045

istar Ultra Access Controller For up to 32 Readers 1 Features Supports up to 32 Readers Network Ready 1 / 5

TECHNOLOGY SOLUTIONS BRIEF

IEEE 488/USB BUS INTERFACES

MR52 READER INTERFACE

Cardax FT Series 3 Command Centre

System Galaxy Hardware Manual

Suprex RS-485 SPX-7500 Wired Reader-Extender

AXP-400. Enterprise. Access Solution

4 balanced inputs 1 relay output

SNAP, CLICK, DONE. Getting Started Guide

AC-225. Advanced Scalable Networked Access Controller. Hardware Installation and User Guide

OSM Features: Field Configurable Reader,I/O to OSDP OSDP to Panel

This is Cansec s 25th anniversary. Many of

SmartLock Pro INSTALLATION MANUAL

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

IPassan Installation guide

Access Control Technology Ltd. reserve the right to change the contents of this manual and the system it applies to without prior notice.

VIDI System Controller

Andover ContinuumTM Infinet II

Fibre Modem - Single-mode

Momentum 171 CCC Processor with Ethernet Communication Port

CYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314

FACIAL RECOGNITION TERMINAL SYSTEM

PXL-250 Tiger Controller

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Access Easy Controller 2.1

WinDSX Microsoft Access and SQL Server Editions

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

CA-A480-A Elevator Controller. Reference & Installation Manual

MR50 READER INTERFACE

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

OM-Link. User guide. Version: 2.1. Copyright 2005, 2006 ORBIT MERRET, s r.o.

Electrical Demand Specification (Reference SOP: )

Biometrics. Biometrics

Compass RTU Guide. Version 3.x

NEW PULSE COMMANDS Interface Card. Host Chassis. TTL/CMOS Input Signals or Contact Closures. High Current TTL Output Lines.

BACnet. b3810 Series Local Controllers

PRT-PX16 16 PGM Output Expander

PRT-RDE2 Ethernet 2 Reader Expander

Transcription:

System Overview The Symmetry M2100 is a key feature of an access control system. It provides distributed intelligence, resilience in the event of netwk failure, and fast response to access requests. The Symmetry M2100 is a modular range of intelligent controllers that provide very flexible configurations f up to: 16 readers 96 Monit Points 32 Auxiliary Outputs 200,000 Cardholders The Symmetry M2100 suppts communication over a netwk, hard-wired connections via a PC pt and remote dial-up modems. Each Symmetry M2100 Database Unit (DBU) fully suppts connection of up to 16 readers and dos. The controllers can be netwked using secure, bi-directional, Pseudo-Random supervised communications to fm a chain of controllers. Each chain of Symmetry M2100 controllers communicates with a PC running the feature rich Symmetry Professional Symmetry Enterprise access control software. The access control software is used to set up the rules of access control, monit alarms, produce repts and administer one me facilities. There can be one me chains, with up to 32 controllers per chain. A hand geometry biometric version of the Symmetry M2100 is also available. This allows unparalleled hardware integration with a hand geometry biometric reader. Each Symmetry M2100 controller is capable of sting and authenticating up to 150,000 templates locally. As with the other Symmetry M2100 controllers, the HGU version is fully intelligent and makes authentication and access decisions locally without needing to refer to a host computer. The Symmetry M2100 controller can www.amag.com eliminate the need f template management systems that require additional training, data entry, wiring, installation and service. Communication Schemes Schemes may be configured as follows: LAN netwk connection using a netwk interface module option card. A hard-wired single chain via an RS 232 to 20mA converter Fault tolerant bi-directional communications by connecting the last controller on a chain to a second pt of the moniting PC Dial-up via modems, providing low cost management f remote sites requiring centralized administration The netwk card also incpates a built in RS-232 module to suppt fallback dial-up of alarms should the netwk be unavailable. Encryption is also available. Reader Technologies & Card Fmats The Symmetry M2100 controller suppts a full range of reading technologies including smart card, biometrics, proximity, magnetic stripe and Wiegand (via Wiegand Interface Modules). A number of default card fmats are programmed as standard and there is the capability f custom fmats to be defined. This is particularly imptant when integrating existing cards with a new system. AMAG Technology, Inc. 20701 Manhattan Place Trance, CA 90501 Phone: (800) 889-9138 Fax: (310) 834-0685 Website: www.amag.com

www.amag.com 4 Do Controller Unit (4DCU/4DCRP) - controls communications f up to four readers and all associated do hardware. The 4 Do Controller board(s) also incpates Flash Memy f downloadable firmware. 4 Do Controller option modules include: Input/Output Module Allows alarms moniting inputs and programmable output switching to be integrated. Each module provides eight monit points and four auxiliary relay outputs. Two I/O modules can be fitted to each board. A fully configured Symmetry M2100 fitted with two 4 Do Controllers can therefe suppt 32 inputs and 16 outputs. 2 Do Controller Unit (2-DCR) provides a means of extending a Symmetry M2100 to a maximum of 16 readers.they interface directly with readers and provide all do control inputs and outputs. The 2 Do Controller communicates with its decision making database unit via a twisted pair RS-485 link. The configuration can be cabled in either star multidrop, dependent upon installation requirements. In the event of a communications failure between a Database Unit and its Do Controller it can be further configured to verify on Customer Code only, the dos can be put into a permanent locked unlocked state. Sufficient spare power is available f up to 400mA per lock. The 2 Do Controller can be fitted with the following plug-in option boards: A WIM 2 board f connection of up to two Wiegand readers. An Input/Output board f eight monit points and four auxiliary relay outputs. RS-485 Reader Interface Module f connection of up to two hand geometry biometric readers in addition to two current loop Wiegand readers. Sufficient spare power is available f the lock of up to 400mA. RS-485 Reader Interface Module Enables connection of up to four hand geometry biometric readers in addition to current loop Wiegand readers Wiegand Interface Module (WIM4) - Enables connection of up to four OEM readers via a Wiegand Electrical Interface Alarms Controller (ACU/ACR) provides 24 monit points and four auxiliary relay outputs. Monit points can be programmed f 2/3/4/6-state supervision, dependent upon requirements.

Symmetry M2100 Connection Capability A maximum of eight DBU addresses can be connected per Symmetry M2100 DBU. The maximum number of readers per Symmetry M2100 cannot exceed 16. TYPE MAX. NO. OF CONTROLLERS PER DBU CONNECTION TYPE FIRMWARE USED DBU ADDRESSES USED PER CONTROLLER ENCL. SIZE SUPPORTED DEVICES SUPPORTED DEVICES VIA OPTION BOARD INPUT POWER DBU N/A 20ma/RS-232/ TCP/IP Standard & N/A 1, 2, & 3 4DCU/4DCRP/ 2DCR/ACU/ACR RS-232 and TCP/IP NIC Modules 18 VAC* 1 4DCU 2 Via Ribbon Cable Standard & 4DCRP 4 External via RS-485 Standard & 2 1 only 4 Readers 16 Inputs 8 Outputs 2 3 only 4 Readers 16 Inputs 8 Outputs Via DBU 18 VAC 18 VAC 2DCR 8 External via RS-485 Standard & 1 2 & 3 2 Readers 2RSI HGU 8 Inputs 4 Outputs 24 VDC 18 VAC ACU 2 Via Ribbon Cable Flash 2 1 24 Inputs 4 Outputs N/A VIA DBU ACR 4 External via RS-485 Flash 2 2 & 3 24 Inputs 4 Outputs N/A 18 VAC* 1 * 1 NOTE: 18VAC input f DBU, 2DCR and ACR requires integrated enclosure power supply. Phone: (800) 889-9138 Fax: (310) 834-0685 Website: www.amag.com

Symmetry M2100 Configurations A comprehensive range of enclosures is available which provide flexible configuration options. All enclosures are supplied with a removable hinged lockable lid, tamper switch and power indicat as standard. When required, enclosures can contain an integrated power supply which may be used to provide the 12VDC supply f the controller and its associated readers. The enclosure power supply board uses an 18VAC external supply. A battery recharge facility is included, with space within the enclosure to accommodate a 12V 7AH maintenance free rechargeable battery. Configuration sizes: CAB-1 (small) can contain any one of the following boards: Database Unit (DBU), 2 Do Controller Remote (2-DCR) Alarms Controller Remote (ACR) CAB-3 (medium) can contain a selection of the following boards: Database Unit (DBU), DBU and 2 Do Controller (2-DCR) Unit, Two 2 Do Controller Remote (2 x 2-DCR), 2 Do Controller with on board power supply (2-DCRP), 4 Do Controller with on board power supply (4-DCRP) an Alarms Controller Remote (ACR) CAB-4 (large) can contain a selection of the following boards: Database Unit (DBU) plus any two Units selected from the four Do Controller Unit (4DCU) Alarms Controller Unit(ACU) Symmetry M2100 Main Items The Symmetry M2100 Database Unit (DBU) contains the system databases and perfms the transaction processing and controls system communications. The DBU is available in four models, suppting 16 readers and 20,000, 50,000, 100,000 and 200,000 cardholders to suit requirements. An eight reader high capacity model suppting 250,000 cardholders is also available. The DBU board incpates Flash Memy suppting downloadable firmware and allowing firmware enhancements via a PC, simplifying upgrades and minimizing installation time. The following options can be plugged into the DBU board when required: RS-232 Module This module converts the upstream communications pt from the secure Pseudo-Random communications to the RS-232 interface, enabling a computer pt to directly connect to the first NODE of a chain. The RS-232 module also allows direct connection to a dial-up modem f remote site applications. Netwk Interface Module This module is used f TCP/IP netwk link communications to its controlling PC. The module is fitted to the first Symmetry M2100 DBU in a chain of controllers. The Netwk Interface Module also incpates an integral RS-232 board to suppt the option of fallback dial-up communications, in the event of netwk failure, via an external modem. The fallback to dial-up alarms repting is automatic when a netwk failure is detected. AMAG Technology, Inc. 20701 Manhattan Place Trance, CA 90501

www.amag.com Typical Configurations

Specifications Reader Types Suppted The Symmetry M2100 controller can be used with any of the following readers: Series 600/700/800 Readers RS-485 RSI Hand Geometry Reader (via RS-485 interface boards) Readers with a Wiegand Interface (via Wiegand Interface Modules) Enclosure Size (Symmetry M2100 Controller - Includes Enclosure (mm) SIZE 1 SIZE 2 SIZE 3 (CAB-4) (CAB-1) (CAB-3) Width: 19.7 (500) 15.1 (385) 16.5 (420) Height: 22 (560) 18.7 (475) 21.7 (550) Depth: 4.1 (105) 3.4 (85) 3.7 (95) Power Requirements CAB-1 (small) - External transfmer 18VAC secondary output rated at 75VA. Sufficient power is available per lock up to 400mA. CAB-3 (medium) - Optional external transfmer 18VAC secondary output rated at 75VA. Sufficient power is available per lock up to 400mA. CAB-4 (large) - External transfmer 18VAC secondary output rated at 75VA. Locking devices and peripheral equipment require a suitable independent external power supply. Operating Environment +32 F to +122 F (0 C to +50 C) 15% to 90% humidity, non-condensing Transmission Speed (Host Communications) Switch-selectable (9600/19200/38400 baud) Communication Distances DBU to PC/Modem (RS-232) = 50ft (15m) DBU Controller board to DBU Controller board (Current Loop) = 3000ft (1000m) DBU Controller board to Do/Alarm Controller board (RS-485) = 3000ft (1000m) total line length Do Controller board to Current Loop Reader = 3000ft (1000m) Do Controller board to Wiegand Reader (via WIM) = 325ft (100m) Stage Capacities Choice of 20,000, 50,000, 100,000 200,000 cardholder memy configurations. An eight reader high capacity model suppting 250,000 cardholders is also available. Controller Inputs/Outputs Reader supply outputs: 12V@200mA max/5v@100ma max Reader Pts: 20mA current loop Do monit inputs: 2/3/4 state supervision Exit Request inputs2/3/4 state supervision Do Release relay outputs: (rated at 30VDC, 3A max) Bypass / shunt relay outputs: (rated at 30VDC, 3A max) ACU/ACR Inputs: 2/3/4/6 state supervision Option Boards Suppted DBU 4DCU/RP 2DCR RS-232 Module 1 N/A N/A Netwk Interface Mod. 1 N/A N/A I/O Modules (8in/4out) N/A 2 1 RS-485 I/F - 4 Reader N/A 1 N/A RS-485 I/F - 2 Reader N/A N/A 1 WIM-4 N/A 1 N/A WIM-2 N/A N/A 1 WIM-1 N/A N/A N/A AMAG Technology Inc. is a subsidiary of Group 4 Technology Ltd. COPYRIGHT AMAG TECHNOLOGY INC. 2006 Infmation contained in this literature is representative only and does not fm part of a contract. Our policy is one of continuous product improvement and details may vary without notification. We are committed to providing defect-free products and services to our customers in partnership with equally committed suppliers and authized dealers. AMAG Technology, Inc. 20701 Manhattan Place Trance, CA 90501 ISO 9001:2000 Certified 9700-1015-06/06 Phone: (800) 889-9138 Fax: (310) 834-0685 Website: www.amag.com