Installation, Operation & Maintenance Instructions

Similar documents
Installation, Operation & Maintenance Instructions / Technical Document

Installation, Operation & Maintenance Instructions

MAXIMA+ Series Rotary Level Indicator

MAXIMA + Series ROTARY LEVEL CONTROL

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

PCM-7140 Pulsed Current Source Operation Manual

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Model Number Structure

PIM-Mini Pulsed Current Source Operation Manual

User's Guide. Phase Sequence and Motor Rotation Tester Model

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Model High Precision Quad Output DC Power Supply

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

USER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

MTP INSTRUCTION MANUAL

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

MAXIMA + Series ROTARY LEVEL CONTROL

S82S (3/7.5-W Models)

User Guide. Control Box. RoscoLED TM.

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Model Number Structure

Capacitive Proximity Sensor E2K-C

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

ORB TM 4-20 ma Input Box Installation & Operation Manual

PRO REMOTE 25 LV CAPACITANCE PROBE

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

CMOS Laser Sensor with Built-in Amplifier ZX0

USER MANUAL MODEL 536S Token Ring (STP) Surge Protector. SALES OFFICE (301) TECHNICAL SUPPORT (301)

E2K-X4ME1 2M E2K-X4ME2 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

AD-7830 Servo Amplifier

Model A7BS

Thread length (overall length)

PRO I Series CAPACITANCE PROBE

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

User s Guide. 600A AC Clamp Meter. Model 38387

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

PRO II X Series CAPACITANCE PROBE

Your Global Flow Control Partner. Series 50 Valve Status Monitor Operation and Maintenance Manual

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

TSD-DA28 2x8 Balanced Line Distribution Amplifier

Solid State Relays with Failure Detection Function

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

User's Guide. MiniTec TM Series Model MN25 MultiMeter

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

E4C-UDA CSM_E4C-UDA_DS_E_12_2

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PRO REMOTE 25 CAPACITANCE PROBE OPERATING INSTRUCTIONS READ THOROUGHLY BEFORE INSTALLING EQUIPMENT Jamieson Equipmen toll free 800

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

E2K-C25MY1 E2K-C25MY2

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

PRO-DVI-CAT. DVI over Single CAT5 Extender. User Manual. Made in Taiwan

User Manual rev: Made in Taiwan

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

SP x4 DVI over Single CAT5 Distribution Amplifier. User Manual. Made in Taiwan

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Model: RK-1

FNet Repeater Installation & Operator s Instruction Manual

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

User Manual CV-87K. PS/2 extender over cat.x. rev: Made in Taiwan

FA-2448 SIX POSITION Filter Wheel

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

Operating Instructions

TRC-190 User s Manual

Adjustable Capacitive Prox E2K-C

PMDX-170 Slotted Optical Sensor

Kramer Electronics, Ltd. USER MANUAL. Model: VM-50AN. 1:5 Audio Distributor

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Remote Refrigeration Control

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Owner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasIED.com

Kramer Electronics, Ltd. USER MANUAL. Model: VP-200XLN. XGA Line Amplifier / DA

USER MANUAL. MODEL 552 Series. High Speed Telco Surge Protectors. SALES OFFICE (301) TECHNICAL SUPPORT (301)

i-series Videoconference Fixture

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Model Number Structure

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2EC. High-sensitivity DC 2-Wire Sensors and Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

Global Water Instrumentation, Inc.

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

CV-24D. Stereo to SPDIF Converter with Adjustable Audio Delay. User Manual. Made in Taiwan

Capacitive Proximity Sensors

Thread length (overall length) material

Conductive Level Controller

DVI over Single CAT5 Series CV-17. DVI over Single CAT5 Extender. User Manual. Made in Taiwan

KBMG MULTI-SPEED BOARD

Transcription:

Installation, Operation & Maintenance Instructions Model CPH and CPU Capacitive Proximity Switches Thank you for purchasing the Model CPH or CPU Capacitive Proximity Switch from BlueLevel Technologies. We sincerely appreciate your business and strive to make your experience with us and our products uniquely positive. This document contains information necessary to ensure a safe and successful installation. PLEASE READ ALL INSTRUCTIONS CAREFULLY BEFORE PROCEEDING and comply with the section on page 3 of this document pertaining to SAFETY to ensure proper operation of the equipment and personnel safety. Before discarding shipping container, please inspect it thoroughly and verify that all parts are accounted for. If you have any questions please do not hesitate to contact us on our website at www.blueleveltechnologies.com, by email at bluelevel@blueleveltechnologies.com or by phone at 330-523-5215 by fax at 330-523-5212. 1

Contents Safety Terms & Symbols 3 Mechanical Installation 4 Capacitive Proximity Switch Function 5 Electrical Connections 6 Calibration 8 Maintenance 8 Technical Data 9 Dimensions 12 Our Commitment 12 Standard Warranty 13 2

Safety Terms & Symbols WARNING: Warning statements identify conditions or practices that could result in injury or loss of life. Risk of electrical shock exists. CAUTION: Caution statements identify conditions or practices that could result in damage to this product or other property. Safety Summary General Safety CAUTION: It is important that all instructions within this manual be followed to ensure proper operation of the equipment and safety of operating personnel. The product should be installed, commissioned and maintained by qualified and authorized personnel only. Install according to installation instructions and comply with all National and Local codes. Use electrical wire that is sized and rated for the maximum voltage and current of the application. Electrical Shock Caution Certain Model CPH and CPU Capacitive Proximity Switches may be powered with HIGH VOLTAGE. All Model CPH and CPU units are completely encapsulated. No serviceable parts are inside. 3

Mechanical Installation Material Flow: Mount the Model CPH/CPU Capacitive Proximity Switch so that it will not be within the path of incoming flow of material. The face of the switch must be at the point where incoming material will reach and cover it during normal material flow, and when receding, the material will flow away from the switch s face in an even manner. Vibration: Mount the switch at a location where limited vibration exists. General: All Model CPH/CPU Capacitive Proximity Switches have an industry standard 30mm threaded housing, M30 X 1.5 threaded process connection. The switch can be easily mounted through a 31mm hole in the tank or bin wall and secured in place with the two (2) lock nuts provided. See Dimensions section. Alternatively, and for liquid level applications specifically, all units can be mounted using any of the Sensor Mounting Accessories as shown in the Technical Information Document, Form 438. Consult the factory with any questions regarding Sensor Mounting Accessories. Unshielded Switch: Unshielded Capacitive Proximity Switches have a spherical electrical field. These units are designed to touch the product, bulk goods or liquids (e.g. granulate, sugar, flour, corn, sand, or oil and water) with their active surface. Surrounding objects can affect the proper operation of unshielded switches. It is necessary to maintain a minimum standard distance of >1.5D (diameter of switch) from other objects or 2D between two switches. Shielded Switch: Shielded switches have a straight-line electrical field. These units are typically used when the circumference of the front of the switch will be embedded in a bin wall or to scan solid targets (e.g. components, PCB s, cartons, bottles, paper piles, etc. at a distance, or liquids through a separating wall up to a maximum of 4mm thick (such as a plastic tank or when using the switch with a Sight Glass mounting accessory for detecting liquid level in a sight tube). 4

Capacitive Proximity Switch Function The BlueLevel Technologies Model CPH/CPU Capacitive Proximity Switch is a compact sensor that is used for detecting the presence and absence of material within proximity or contact of the sensor. It is a low cost, low profile sensor offering high value as a level control instrument. It is used to detect liquids, powders and granular materials at predetermined levels within tanks, hoppers, bins, silos and other types of vessels, and operates efficiently in a wide array of industries. These sensors can be used for high (full detection), low (empty detection) and intermediate (demand detection) level monitoring, as well as sight-tube level detection and the detection of non-metallic targets on moving conveyor belts and also in conveyor belt positioning and material stacking. These sensors operate based on a proven principle. Capacitive Proximity Switch sensors are designed to operate by generating an electrostatic field and detecting changes in this field caused by the presence of a target material approaching or contacting the sensor face. Capacitive Proximity Switches consist of an RCoscillator with a special multi-part sensing electrode. When the target material is removed from within the field created by the sensor, the oscillator becomes inactive and the amplitude decreases. As a target approaches the sensor field, it increases the capacitance of the sensor system. When the capacitance reaches a specified threshold, the oscillator is activated, which triggers the output circuit to change between on and off. The capacitance of the sensor system is determined by the dielectric constant of the target material, its proximity or distance from the sensor face and the size or mass of the target. The larger the size, the higher the dielectric constant and the closer it is to the sensor, the more it increases capacitance. Level sensing and control applications will place the material in contact with the Capacitive Proximity Switch sensor face. Adjusting or calibrating the sensor to respond when it is in contact with or close to the target material is accomplished simply using the built-in potentiometer. Adjusting this potentiometer adjusts the oscillator amplifier voltage and hence the sensitivity of the sensor, increasing it or decreasing it. 5

Electrical Connections CAUTION: DO NOT operate an incandescent light bulb as a load. The current inrush can cause a current overload and damage the Model CPH/CPU capacitive proximity switch. CAUTION: DO NOT operate a capacitive proximity switch directly from a power supply voltage without a load. This is a short circuit and can cause damage to the Model CPH/CPU capacitive proximity switch. CAUTION: Properly grounding your bin, conduit system and piping to eliminate static discharge. Static discharge directly to the capacitive proximity switch may cause damage. CAUTION: DO NOT install proximity sensor cable or wiring in the same conduit as motor power wiring as this can cause damage to the Model CPH/CPU capacitive proximity switch. 6

Electrical Connections - Cont d. 7

Calibration Follow the below steps for calibrating the Model CPH/CPU Capacitive Proximity Switches: 1. To adjust the sensitivity on a Capacitive Proximity Sensor, mount the sensor in the working position. 2. Allow the target material to reach the position where detection should take place. 3. If the material has not been detected, rotate the sensitivity potentiometer clockwise, with the screwdriver provided, until detection first occurs (LED will illuminate). 4. Continue to rotate the potentiometer for another ¼ turn. 5. Remove the target material and ensure that the sensor turns OFF (LED will turn off). 6. If the sensor turns OFF, leave the sensitivity at that position. 7. If the sensor remains ON, decrease the sensitivity (counterclockwise rotation) until the sensor turns OFF. 8. For best results, position the sensitivity potentiometer half way between these two points. Sensitivity Potentiometer Locations: AC and AC/DC Switches: On back of switch. DC Switches: On back of switch; to access potentiometer, remove screw above/between the Red & Green LED s on back of switch. Maintenance All Model CPH/CPU Capacitive Proximity Switches are fully encapsulated solid-state devices and are therefore maintenance free. 8

Technical Data Model CPH 2-Wire AC Switches Sensing Distance: Unshielded 30mm Shielded 20mm Operating Voltage: 20-250VAC No Load Current: < 2.5mA Maximum Load Current: 300mA Leakage Current: < 2.5mA Surge Current: 5A Minimum Load Current: 5mA Voltage Drop: < 9VAC @ 300mA Switching Frequency: 25Hz Response Time: 10ms Switching Hysteresis: <15% (Sensing Range) Repeat Accuracy: < 5% (Sensing Range) Housing Protection Category: IP 67 Operating Temperature: -13 F to +158 F (-25 C to +70 C) Temperature Drift: < 10% (Sensing Range) Short Circuit Protection: No EMC: RFI 3V/m EFT 1KV ESD 4KV (contact) Shock/Vibration: IEC 60947-5-2, Part 7.4.1, 7.4.2 Active Face Material: PBT (Polybutylene Terephthalate) Housing Material: PBT Certifications: CE Mark ccsa us Ordinary Locations 9

Technical Data - Cont d. Model CPH 4-Wire DC Switches Sensing Distance: Unshielded 2-30mm Shielded CONSULT FACTORY Operating Voltage: 10-30VDC Ripple: < 10% No Load Current: < 10mA Maximum Load Current: 300mA Leakage Current: 0.01mA Voltage Drop: < 2VDC Switching Frequency: 100Hz Response Time: 1.5ms Switching Hysteresis: <15% (Sensing Range) Repeat Accuracy: < 5% (Sensing Range) Housing Protection Category: IP 67 Operating Temperature: -13 F to +158 F (-25 C to +70 C) Temperature Drift: < 10% (Sensing Range) Short Circuit Protection: Yes Overload Trip Point: 220mA Time Delay Before Availability: <25ms EMC: RFI 3V/m EFT 1KV ESD 4KV (contact) Shock/Vibration: IEC 60947-5-2, Part 7.4.1, 7.4.2 Active Face Material: PBT (Polybutylene Terephthalate) Housing Material: PBT Certifications: CE Mark ccsa us Ordinary Location 10

Technical Data - Cont d. Model CPU 2-Wire AC/DC Switches Sensing Distance: Unshielded 20mm Shielded 15mm Operating Voltage: 20-250VAC/VDC No Load Current: < 2.5mA Maximum Load Current: 200mA Leakage Current: < 2.5mA Surge Current: 2.2A for 20ms Minimum Load Current: 5mA Voltage Drop: 10VAC / 8VDC Switching Frequency: 25Hz (AC) / 40Hz (DC) Response Time: 10ms Switching Hysteresis: <15% (Sensing Range) Repeat Accuracy: < 1% (Sensing Range) Housing Protection Category: IP 67 Operating Temperature: -13 F to +158 F (-25 C to +70 C) Temperature Drift: < 15% (Sensing Range) EMC: RFI 3V/m EFT 1KV ESD 4KV (contact) Shock/Vibration: IEC 60947-5-2, Part 7.4.1, 7.4.2 Active Face Material: PBT (Polybutylene Terephthalate) Housing Material: PBT Certifications: CE Mark ccsa us Ordinary Locations 11

Dimensions (unshielded prewired 30mm 2-Wire AC and AC/DC version shown) Our Commitment Stands Golden Parachute: Each BlueLevel Technologies Model CPH/CPU Capacitive Proximity Switch product is backed by our Golden Parachute support program. If you are the initial purchaser and purchased the product directly from BlueLevel Technologies, this provides you with added assurance. The Golden Parachute support program gives the initial purchaser 90 days to evaluate the product. Within this time frame if you are not satisfied for any reason, call us and request a Golden RMA, providing your order details and serial number on the unit, and then return the unit and request a replacement or a credit to your account for the cost of the equipment as shown on your invoice from BlueLevel Technologies. In addition, all BlueLevel Technologies products are covered by our industry-leading lifetime limited warranty. Consult our Warranty statement for details. 12

Standard Warranty Summary: Each BlueLevel Technologies Model CPH/CPU Capacitive Proximity Switch product is backed by our five-year limited warranty. Should you experience a problem with one of our products deemed by our factory to be a product failure covered by our warranty, we will repair the unit at our factory or provide you with a replacement unit or sub-assembly at our discretion. A return authorization number must be obtained from a BlueLevel Technologies customer service technician BEFORE returning any unit. Refer to the below details for more information. Details: We warrant BlueLevel Technologies products to be free from defects in workmanship and materials when operated under normal conditions and in accordance with nameplate characteristic limits for a period of five (5) years from the date of shipment. Products must be installed and maintained in accordance with BlueLevel Technologies installation, operation and maintenance instructions. Users are responsible for the suitability of the products to their application. There is no warranty against damage resulting from misapplication, improper specifications, or other operating conditions beyond our control. Claims against carriers for damage in transit must be filed by the buyer. THIS WARRANTY SHALL BE IN LIEU OF ANY OTHER WARRANTY, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. BlueLevel Technologies will repair or replace, at its option, any product which has been found to be defective and is within the warranty period, provided that the product is shipped, with previous factory authorization, freight prepaid, to the factory in Peru, Illinois, U.S.A., or to the nearest service station. BlueLevel Technologies is not responsible for removal, installation, or any other incidental expenses incurred in shipping the products to or from BlueLevel Technologies. BlueLevel Technologies liability under this warranty shall be solely limited to repair or replacement of the products within the warranty period, and BlueLevel Technologies shall not be liable, under any circumstances, for consequential or incidental damages, including, but not limited to, personal injury or labor costs. Under no circumstances will BlueLevel Technologies be responsible for any expense in connection with any repairs made by anyone other than the factory or an authorized service station, unless such repairs have been specifically authorized in writing. 13

14

15

3778 Timberlake Dr. Richfield, OH 44286 330-523-5215 Fax: 330-523-5212 www.blueleveltechnologies.com bluelevel@blueleveltechnologies.com Copyright 2013 BlueLevel Technologies Form 728 Printed in USA June 2016 16