Server Technology Inc.

Similar documents
Server Technology, Inc.

Server Technology Inc.

Models. Specifications

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Sentry Metered, Smart, and Switched High Density 30 Receptacle 208VAC, 3-Phase 30A Products

How do I... If you manage a datacenter, we have a solution for you.

Fail-Safe Power Redundancy

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

HP Power Calculator Utility: a tool for estimating power requirements for HP ProLiant rack-mounted systems

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

Deploying High Power to IT Equipment Racks

The -3Ph extension on a product indicates a 3 Phase power product.

Deploying High Power to IT Equipment Racks

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

Density in the Data Center

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

Server Technology White Paper

Server Technology, Inc.

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

Energy efficiency within data centers Is your IT organization capitalizing on the latest technology options and best practices?

Data Center Power: Managing for Energy Efficiency and Cost Savings

Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center

C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features

SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers

Bus Way vs. Cable: a CapEx comparison

THE OFFICIAL TRADE JOURNAL OF BICSI

Maximise Data Center Value

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Power Distribution. For technical support call Online catalog available at leviton.com 461

E-Series Site Preparation Guide

Cisco CRS 16-Slot Chassis Power Systems

How do I... Sentry Power Manager Rack-Level Data Center Power Monitoring & Management. If you manage a datacenter, we have a solution for you.

Server Technology Technical Data Sheet

Power distribution solutions for the ProLiant DL580 G2 server

Power Distribution Units for Data Centers

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Three Phase Systems-International PC302-I/MTD

IBM eserver System x and BladeCenter IBM DPI PDU+ Power Distribution Units. 10/9/ IBM Corporation

PRODUCT BROCHURE. Deploying effective power protection in data centers

Data Center Power Savings

Features and Benefits: Power IQ DCIM Monitoring Solutions

Power Distribution Units for Data Centers

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

APC APPLICATION NOTE #74

RCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number

The Basics of Selecting Rack-Mount Power Distribution Units (PDUs) and Power Strips

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

MAJOR VA Power Inverter

The purpose of this document is to specify the power requirements for Core Health and Fitness LLC equipment.

The ipdu Handbook. A Guide to Intelligent Rack Power Distribution

Frequently Asked Questions

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

G5 PDU Installation Guide

HP Proliant DL360 G6 Carrier-Grade Server Read Before Install

920 Remote Control (RC) Switches

Billion SG3015. Compact ZigBee Power Meter Series. Fully complied with IEEE

Applying branch circuit breakers and supplementary protectors in North America

PDU Branch Current Monitoring Board Installation and Configuration

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

Axxium Pro - iseries (AS/400) Integration

Test Asset Optimization Services Power Line Utilization Module (PLUM) DATA SHEET

Green IT and Green DC

Highly Efficient Power Protection for High Density Computing Applications

Part Numbers SNAP-IT-EMU1

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

QuickSpecs. HPE Standard Power Supplies. Overview. HPE Standard Power Supplies

Introducing Server Technology s PRO1 Rack Power Distribution Unit

QuickSpecs. HPE Common Slot Power Supplies. Overview

Instruction Manual Basic Rack PDU VP7541 and VP9571A

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Applying branch circuit breakers and supplementary protectors in North America

PRODUCT & SYSTEM OFFERINGS

Instruction Manual. Rack PDU XP Series. geistglobal.com

QuickSpecs. HPE Basic Power Distribution Units (PDU) Overview

SLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters

Polar PDUs POWER MANAGEMENT

Remote Management of Data Center White Space: What to Manage and How? Ashish Moondra Sr. Product Manager Chatsworth Products

SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America

SmartOnline SVX Series 120kVA Modular, Scalable 3-Phase, On-line Double-Conversion 400/230V 50/60Hz UPS System

Technical Specifications

iconverter 2-Module Power Chassis

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

HP Modular Cooling System: water cooling technology for high-density server installations

Single Phase Systems-North American PC125/PC420 Series

HP BladeSystem c-class enclosures

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

FP-PS-4. Features. Installation

SPECIFICATION. SFX Form Factor. SST-ST45SF 450W Switching Power Supply Active PFC Circuit Full Range Input. SFX Form Factor

QuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

ASCO 920 Remote Control (RC) Switches

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Server Specifications

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

Transcription:

Server Technology Inc. Power Efficiency Gains by Deploying 415 VAC Power Distribution in North American Data Centers White Paper STI-100-008 2011-Sept-22 Headquarters Server Technology, Inc. 1040 Sandhill Drive Reno, NV 89521 United States of America +001 (775) 284 2000 Tel +001 (775) 284 2065 Fax sales@servertech.com www.servertech.com www.servertechblog.com EMEA Server Technology Intl. Sienna Court The Broadway Maidenhead Berkshire SL6 1NJ United Kingdom +44 (0) 1628 509053 Tel +44 (0) 1628 509100 Fax salesint@servertech.com APAC Server Technology, Inc. 37 th Floor, Singapore Land Tower 50 Raffles Place Singapore, 048623 +65 (0) 6829 7008 Tel +65 (0) 6234 4574 Fax salesint@servertech.com

Overview Within enterprise data centers, power used for operating the facility, lighting, running IT loads and cooling it is the largest operational expense within the facility. Numerous papers and articles have been published by The Green Grid, The Uptime Institute, PG&E, Lawrence Berkeley Laboratories and others discussing ways to measure, monitor and increase efficiencies. This paper discusses various approaches to reducing power consumption and to increase end-to-end efficiency in the data center by bringing 415 VAC to the cabinet level. With power densities continuing to rise, more efficient solutions continue to be explored especially as power cost increases and power availability decreases. The power path from the building entrance to the IT loads contains several power converters and transformers with each conversion; there is a loss of power. Reducing the number of transformers and operating at a higher voltage improves efficiency and reduces electrical costs. This paper discusses an alternative approach to power distribution, presently being implemented in North American data centers that increase efficiencies and savings by reducing upfront capital costs, power consumption and floor space. 2 Power Efficiency Gains by Deploying 415 VAC Power Distribution www.servertech.com

Baseline: Current North American ase Power Distribution To understand this new approach to power distribution within the cabinet, it helps to understand the current standard distribution systems. In North America, 277/480 VAC, ase power is delivered to most large commercial buildings and IT facilities. The voltages are measured from line-to-neutral (277 VAC) and line-to-line (480 VAC), as shown below in Figure 1. Automatic switching power supplies inside IT equipment typically operate within a range from 100 VAC to 240 VAC single-phase so the utility power delivered to the facility must be stepped down from 277 VAC through isolation transformers before it may be used, as outlined in Figure 3. This is achieved by routing the power through a Power Distribution Unit (PDU) transformer where it is stepped down from 480 VAC ase to ase. Figure 2. 480 VAC ase power at the building entrance Figure 1. ase after the PDU transformer. 120 VAC line-to-neutral Cabinet PDU Cabinet PDU Utility Power Grid A 480 VAC 3-Phase 120VAC or 1-Phase 120VAC or 1-Phase Utility Power Grid B 480 VAC 3-Phase UPS UPS 480 VAC 3-Phase 480 VAC 3-Phase Low Voltage Transformer Low Voltage Transformer 3-Phase 3-Phase Power Distribution Unit 120/ 1- or ase Power Distribution Unit 120/ 1- or ase Figure 3. 480 VAC ase to power path www.servertech.com Power Efficiency Gains by Deploying 415 VAC Power Distribution 3

From the primary PDU, power is typically distributed in three ways by remote power panels (RPP) or cabinet-level power distribution units (CDU): 1. 120 VAC single-phase (measured line-to-neutral) 2. single-phase (measured line-to-line) 3. ase (in a Delta or Wye configuration). Most IT devices have automatic switching power supplies that will accept both low-line voltages 100-120 VAC and high-line voltages 200-240 VAC. Running devices at the higher voltages will increase efficiencies approximately 2 to 3.5 percent, so the first step for data center managers is to ensure all devices that are capable of operating at are doing so by reviewing the nameplate ratings to determine the operating voltage range. In distribution systems, is achieved by powering IT devices with a line-toline configuration versus line-to-neutral for 120 VAC, Figure 2. The advantage of this system is the capability of delivering 120 VAC for legacy devices; however, as mentioned before, most devices have universal power supplies capable of operating at higher voltages. Within the IT device's internal power supply, power goes through one more transformation and conversion where 120 VAC or is rectified to DC and stepped down to 12 VDC or other voltages using DC-DC conversion circuitry, Figure 4. 120 VAC or 1-Phase 120 VAC or 1-Phase Device Internal Power Supply Unit 12 VDC 5 VDC 3.3 VDC 120/ 1- or ase Cabinet Power Distribution Unit Figure 4. CDU power distribution within the rack With demands for higher densities and compute power, the ase distribution system is being replaced with a 415 VAC ase systems commonly used throughout the world. 4 Power Efficiency Gains by Deploying 415 VAC Power Distribution www.servertech.com

415 VAC ase Power Distribution Power and cost savings in the data center can be achieved by reducing the number of power transformations and operating at higher voltages. This can be done by converting the UPS output from 277/480 VAC to 240/415 VAC through an autotransformer and eliminating the PDU transformer. Alternatively, the PDU transformer may be replaced with a PDU autotransformer. In a 415 VAC distribution system, the line-to-neutral voltage is 240 VAC. It is important to note that this is a significant difference from the typical US Baseline System where the line-to-neutral voltage is 120 VAC after the PDU transformer. This approach doubles the voltage being delivered to the devices while increasing efficiencies and reducing installation costs by eliminating components and using smaller diameter cables for distribution. The 415 VAC power distribution system that is used in much of the world outside of North America is now beginning to gain a foothold within the U.S. and Canada. According to various UPS manufacturers, eliminating the PDU transformer will result in a 2% efficiency gain. 415 VAC 3-Phase 3-Phase Figure 5. Difference between 415 VAC and power distribution systems Baseline: 3-Phase 480 V UPS 480 V PDU Transformer 208 V PDU 208 V 1- or 120V 1-ph CDU 208 V 1- or 120V 1-ph 415 VAC 3-Phase 480 V UPS w/ Autotransformer 415 V ase PDU 415 V ase 240 V 1-phase CDU 240 V 1-ph 480 V UPS 480 V PDU w/ Autotransformer 415 V ase 240 V 1-phase CDU 240 V 1-ph Figure 6. Comparison between the baseline power path and the 415 VAC power path with the elimination of the PDU transformer www.servertech.com Power Efficiency Gains by Deploying 415 VAC Power Distribution 5

Additionally, operating rack-level equipment at 240 VAC vs. will provide an additional 1% to 1.5% efficiency gain as shown in Table 1 for the HP ProLiant DL380. Table 1. HP ProLiant DL380 Generation 5 (G5) Power Supply Specification Operational Input Voltage Range (Vrms) 90 to 264 Frequency Range (Nominal) (Hz) 47 to 63 (50/60) Nominal Input Voltage (Vrms) 100 120 208 220 230 240 Max Rated Output Wattage Rating 800 850 1000 1000 1000 1000 Nominal Input Current (A rms) 10.0 8.8 5.85 5.5 5.2 4.97 Max Rated Input Wattage Rating (Watts) 980 1035 1193 1186 1172 1169 Max. Rated VA (Volt-Amp) 1000 1056 1217 1210 1196 1193 Efficiency (%) 81.5 82 84 84 85 85.5 Power Factor 0.98 0.98 0.98 0.98 0.98 0.98 Leakage Current (ma) 0.44 0.52 0.91 0.96 1.00 1.04 Max. Inrush Current (A peak) 30 30 30 30 30 30 Max. Inrush Current duration (ms) 3 3 3 3 3 3 To gain a better understanding of the benefits of a 415 VAC system, consider what is necessary to deliver redundant power to a high density rack of blade servers. Using the power configuration calculator from a major blade system manufacturer, the power requirement for four fully populated blade systems is 15.1 kw. Table 2 below shows four different approaches to delivering this amount of power to the rack along with the number of power drops needed to provide redundancy. Table 2. Power Capacity Comparison kw (Continuous Power Drops Total Drops for Voltage 1- or 3-Phase Current kw Rating) Required Redundancy 415 3 30 21.6 17.3 1 2 208 1 30 6.2 5.0 4 8 208 3 30 10.8 8.6 2 4 208 3 60 21.6 17.3 1 2 415 VAC System 30 A x 3 x 240 V x 0.80 de-rating = 17.3 kw 1-Phase, 30 A System 30A x 208 V x 0.80 de-rating = 5.0 kw 3-Phase, 30 A System 30 A x 1.732 x 208 V x 0.80 de-rating = 8.6 kw 3-Phase, 60 A System 60 A x 1.732 x 208 V x 0.80 de-rating = 17.3 kw 6 Power Efficiency Gains by Deploying 415 VAC Power Distribution www.servertech.com

Efficiency gains by implementing a 415 VAC design are typically 4 to 5%, see Figure 7. Upfront cost savings are also realized from eliminating the PDU transformer, using smaller gauge power cords and less expensive plugs, taking up fewer poles at the breaker panel and requiring fewer power drops to the cabinets. Additional savings come from reductions in cooling costs with the elimination of the PDU transformers and at the cabinet-level by having fewer CDUs and cable drops which can also impede airflow. Additionally, though a 208 V, 60 A system provides the same power as a 415 V, 30 A system, lower current flow allows use of smaller conductors thus lowering the initial costs and reduces line losses due to cable resistance. 2% efficiency gain by eliminating transformer 2-3% efficiency gain by running equipment at 240 VAC over 120 VAC Figure 7. Efficiency gains by eliminating the transformer and running equipment at 240 V rather than 120 V Table 3 demonstrates the annual cost savings by implementing a more efficient power distribution system based on a $0.10 per kw-hr rate. Since energy rates vary from region to region, higher cost areas will realize greater savings. In general, power distribution equipment is more efficient and runs cooler while operating in the middle of their designed range; therefore additional cost savings can be achieved by understanding the capacity requirements for meeting immediate needs with the ability to expand to accommodate future growth. Table 3. Annual energy savings from efficiency gains IT Load (kw) 1% 2% 3% 4% 5% 250 $2,190 $4,380 $6,570 $8,760 $10,950 500 $4,380 $8,760 $13,140 $17,520 $21,900 750 $6,570 $13,140 $19,710 $26,280 $32,850 1,000 $8,760 $17,520 $26,280 $35,040 $43,800 1,500 $13,140 $26,280 $39,420 $52,560 $65,700 2,000 $17,520 $35,040 $52,560 $70,080 $87,600 Calculations based on $0.10/kW-hr www.servertech.com Power Efficiency Gains by Deploying 415 VAC Power Distribution 7

Distributing 415 VAC at the Cabinet Level At the cabinet level, power to the IT loads is distributed through a Cabinet Power Distribution Unit (CDU). The CDUs designed for ase systems are not compatible with 415 VAC systems because they are wired line-to-line. In order to deliver 240 VAC single-phase, the outlets must be wired line-to-neutral. Server Technology offers designs that meet these requirements such as the Sentry Switched CDU below that offers a combination of IEC 60320 C13 and C19 outlets. Figure 8. Server Technology Cabinet Power Distribution Unit (CDU) shows an example of a CDU configured for 415 VAC service. This particular CDU has three outlet sections, each split into two branches protected by 20 A fuses allowing it to deliver 17.2 kw, the full capacity of the circuit. With this design, if the current in Branch 1 exceeds 20 A, it will blow the fuse and remove power to the branch leaving the rest of the CDU running normally. Branch 1-2 CDU Fuses for Branch 1 and 2 Branch 3-4 Branch 1 Branch 2 Branch 5-6 Figure 8. Server Technology Cabinet Power Distribution Unit (CDU) Power Monitoring Using Server Technology POPS (Per Outlet Power Sensing) In order to manage power usage, the capability to measure and monitor it must be present. Since the CDU is the most intelligent device closest to the IT load, it is an ideal point to monitor power consumption. Intelligent, Smart or Switched CDUs are equipped with local LEDs displays that provide useful information at the cabinet when powering up and load testing; however, they provide little useful information over the course of a day, week or month. Since power draw varies, CDUs designed with the ability to be networked and to allow power information to be queried, polled and trended at both a circuit and down to the device level will provide Data Center and Facilities managers a better understanding of actual equipment power usage and identify underutilized equipment. Information can also be rolled up so power usage can be viewed by device, at an application level, or at a cabinet row or floor level. Additionally, the accumulated data may be used to calculate the PUE (Power Usage Effectiveness) and other metrics established by The Green Grid and other organizations to gauge and analyze power consumption and efficiency. 8 Power Efficiency Gains by Deploying 415 VAC Power Distribution www.servertech.com

Environmental Monitoring Maintaining the proper temperature and humidity range within the cabinet has become even more critical as densities within the cabinet and higher server utilization due to virtualization increases. Server Technology CDU's have the capability to monitor and send alerts from up to four combination temperature and humidity probe inputs. Additionally, when used with Server Technology's Sentry Power Manager, temperature, humidity and power may be logged and trended. 120 V IT Devices IT equipment may be supplied with a 120 VAC NEMA power cord that will not be compatible with the CDU in a 415/240 VAC distribution system. Fortunately, most IT equipment manufacturers use power supplies that accept 100 V to 240 V and have standardized on IEC connectors for their products such as the Dell 2161 DS KVM Switch, which is designed with an IEC 60320 C14 inlet. This allows the power cord to be changed out to an IEC type cord. For those devices that do not have universal power supplies that will accept 240 VAC, rackmounted transformers are available from a number of vendors. 100-240V~,1.0A,50/60Hz 1 3 5 7 2 4 6 8 9 11 13 15 12 14 16 10 LAN T 2A, 250 VAC CAUTION: For continued protection against risk of fire, replace only with same type and rating of fuse. IEC C14 inlet Figure 9. IT Equipment with IEC C14 inlet C13 Outlet 125/250 V, 15 A C14 Plug 125/250 V, 15 A C19 Outlet 125/250 V, 20 A C20 plug 125/250 V, 20 A Figure 10. IEC 60320 outlets and plugs to connect IT equipment to the CDU www.servertech.com Power Efficiency Gains by Deploying 415 VAC Power Distribution 9

Summary With small data centers operating in the range of tens of kw and large data centers running in tens of MW, incremental increases in efficiencies translate into large savings. There are several other proposed power distribution architectures being discussed such as rack-level and facilities-level DC power distribution and 277 VAC distribution. The Data Center Pulse group, an organization of data center owners, operators and users, recently held their inaugural conference in February 2009. They compiled a list of their top ten goals, one of which is to eliminate all transformers and deliver 277/480 VAC at the rack level. These discussions are beyond the scope of this paper; however, reducing the number of transformations and conversions will increase end-to-end efficiency. Server Technology understands these requirements and will continue to innovate and develop products to meet these needs. 10 Power Efficiency Gains by Deploying 415 VAC Power Distribution www.servertech.com

Server Technology, the Server Technology Globe, CDU and Switched CDU are registered trademarks of Server Technology, Inc. All other trademarks and registered trademarks belong to their respective owners. www.servertech.com Power Efficiency Gains by Deploying 415 VAC Power Distribution 11