D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES

Similar documents
D1000M SERIES FOR MODBUS SENSOR TO COMPUTER INTERFACE MODULES

NetBiter I/O Extender User Manual

Isolated, Field Configurable Analog Input 6B11 / 6B11HV FEATURES APPLICATIONS PRODUCT OVERVIEW

MICRO SERIES PROCESS DISPLAYS LARGE DIGIT MODELS

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Intech Micro 2300-RO4 analogue input station MODBUS RTU slave application supplementary manual.

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

ADAM-6200 Series. Feature. Transition and Vision on Remote DAQ Device 19-13

RS-485 I/O Modules: ADAM-4000

LAUREL ELECTRONICS, INC.

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

ProfiPro Distributed PROFIBUS I/O Modules User Manual

D1000 and D2000 SERIES SENSOR TO COMPUTER INTERFACE MODULES

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels

LAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

Isolated Process Current Input with Loop Power 7B35

Trident and Trident X2 Digital Process and Temperature Panel Meter

LAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.

Isolated Process Current Input 7B32 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Isolated, Voltage or Current Input 7B30 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

Isolated Voltage Input 7B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

ACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions

DIN-191 and DIN-192 SERIES CONVERTER BOXES USERS MANUAL

LAUREL ELECTRONICS, INC.

Temperature/Process Controllers Manual

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

MODBUS RTU I/O Expansion Modules - Models C267, C277, and C287. Installation and Operations Manual Section 50

PBSCONTROL. AMS-R4000 Modular RTU. Remote Terminal Unit

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

Isolated Voltage Input 3B30 / 3B31 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

SX90 Process Controller

MOD-MUX MODBUS TCP I/O PRODUCTS

The IQ240 panel mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Isolated, Voltage or Current Input 7B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Pen Drive USB Datalogger!

8 Channel Analog Input Module Datasheet. Address / Baud rate / range configurable by the user

iologic E1200 Series Remote Ethernet I/O with 2-port Ethernet Switch Introduction Industrial I/O

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

900EN Series. Acromag RUN ST DIO STATUS ACT LINK DFT RST ETHERNET TB1

Carbon Monoxide Sensor - ModBus

iologik R1200 Series User s Manual

DI-917MB/DI-918MB. Heavy-duty 1A solid-state relays provide dependable on/off control of industrial devices. Analog Output Module. Four Analog Outputs

MOD-IO9 Modbus Input / Output Modules, Wall Mounted

DUAL-LINE TEMPERATURE METER

DSP240-LPI Inverter Controller Card. Technical Brief

iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O

Isolated, Process Current Output 7B39 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Multi-Point Gas Detection and Control System

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Getting Started with your D3000M Series Module

DI-924MB. Thermocouple/Millivolt Input Module

Part Numbers. SNAP-AIARMS-i SNAP-AIARMS-i-FM* SNAP-AIVRMS-i SNAP-AIVRMS-i-FM* SNAP-AIMA-i. SNAP-AIMA-iSRC SNAP-AIMA-iSRC-FM* SNAP-AIMA2-i.

LAUREL. Laureate Rate Meter & Totalizer with Functions A+B, A-B, AxB, A/B, A/B-1 ELECTRONICS, INC. Features. Description

Product Description. Contents. Fusion Series. New Information December 2003

Technical specification

ADAM Data Acquisition Modules User's Manual

Product Specification for SAB-S-MODBUS

8B SLX300 Data Acquisition System

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

Wall-/Pipe Mounted Universal Process Indicator

iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

Features and Benefits. Certifications

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Millenium II +: general characteristics

Simplified information where and how you want it.

iologik E1200 Series User s Manual

Measurement Systems Datascan Installation and User Guide

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

smart meters... 6 panel meters... 7 field displays... 8 display types loop powered displays TRANSMITTERS & CONVERTERS...

WHERE THE FUTURE MEETS THE PRESENT. Datascan. solo Network Based Data Acquisition System

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

6220 Ethernet-Based Voltage Measurement Module

Tempco Instruction Manual

USB-1602HS-2AO Specifications

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

6220 Ethernet-Based Voltage Measurement Module

LGR-5325 Specifications

EGW1-IA3-MB User s Manual

Signal Conditioning Modules and Terminal Boards

C160 Wall-/Pipe Mounted Universal Process Indicator

DIGITAL INDICATING CONTROLLER

VersaMax Micro and Nano Technical Product Presentation

LGR-5327 Specifications

ECS ecompass Series. ECS ecompass Series. Strap down Electronic Compass. General Description. Features. Making Sense out of Motion

TWDLCAE40DRF compact PLC base Twido V AC supply - 24 I 24 V DC - 16 O

D8000 SERIES QUICK START GUIDE

Transcription:

11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet Protocol. Up to 25 conversions per second. 500Vrms analog input or analog output isolation. 16-bit analog input measurement resolution. Continuous self-calibration; no adjustments required. Programmable analog input digital filters. Requires +10V to +30Vdc unregulated supply. Removable screw terminal plug connectors supplied. Peer-To-Peer communication APPLICATIONS Process monitoring and control Remote data logging to any host computer Peer-To-Peer Communication Product testing GENERAL DESCRIPTION The D7000 series modules are a family of complete data acquisition modules for use in process control systems. The analog input models can measure process signals such as: voltage, thermocouples, 4-20mA loops, and discrete contact closures. The analog output models can generate voltage or current signals for controlling annunciators or valves. The digital input and output models can sense the state of remote digital signals or control solid state relays Complete data acquisition systems can be created with ease with the D7000 modules and a host supervisory computer or programmable logic controller. The modules provide direct connection to a wide variety of sensors and annunciators. They perform all signal conditioning and linearization and contain no pots or DIP switches. All user-selectable settings, such as ranges, communications settings are stored in nonvolatile EEPROM, which maintains these values even after power is removed.

D7000 SPECIFICATIONS (typical at +25 C and nominal power supply unless otherwise noted) General Programmable digital filters in analog input modules. Max CMV, input to output at 115Vrms, 60hz: 500V rms. All setups stored in EEPROM. Software disable unused analog input channels. Communications via Modbus TCP/IP protocol. RJ-45 Ethernet 10/100MB. Power Requirements Unregulated +10V to +30Vdc. Protected against power supply reversals. Environmental Temperature Range: Operating -25 C to +70 C. Storage: -25 C to +85 C. Relative Humidity: 0 to 95% non-condensing. Warranty 12 months on workmanship and material. Package, Dimensions and Connectors Case: ABS thermoplastic, UL-94-5VA rated. Dimensions: 6 x4 x1.5, mounting holes 6.5 on center. Connectors: Screw terminal barrier plug (supplied). Replace plug with LMI Components 04238 Series. MODULE SPECIFICATIONS D7100 Voltage Inputs Seven differential voltage inputs. Ranges: 25mV, 50mV, 100mV, 1V, 5V, 10V. Accuracy: 0.05% of FS max. Span Tempco: 50ppm/ C max. Input burnout protection to 250 Vac. Input impedance: 20M min. D7200 Current Inputs Seven differential current inputs. Range: 20mA. Accuracy: 0.05% of FS max. Span Tempco: 50ppm/ C max. Voltage drop: 2.0V max. Input Impedance: <100 Ohms (70 typical). D7300 Thermocouple Inputs Seven differential thermocouple inputs. Thermocouple types: J, K, T, E, R, S, B, and C. Ranges: J = -200 760 C R = 0 1750 C K = -150 1250 C S = 0 1750 C T = -200 400 C B = 0 1820 C E = -100 1000 C C = 0 2315 C All D7000 specifications are subject to change without notice. D7300 Thermocouple Inputs (cont'd) Thermocouple Accuracy (error from all sources) from 0-40 C ambient: J, K, T, E = 1.5 C max. R, S, B, C = 3.5 C max (300 C to +F.S.). Input impedance: 20M min. Automatic cold junction compensation. Lead resistance effect: <40 V per 350. Open thermocouple and over range indication. Input burnout protection to 250Vac. D7400 Voltage, Thermocouple, Current Inputs Seven Differential voltage, thermocouple, current inputs. Specifications equal to D7100, D7200 and D7300 series. D7500 Analog Outputs Two analog outputs. Programmable voltage or current ranges. Voltage Ranges: 0-10Vdc, 10Vdc. Current Ranges: 0-20mA, 4-20mA. 250 conversions per second. Accuracy: 0.1% 12-bit DAC resolution. Span Tempco: 25ppm/ C max. Settling Time to 0.1% FS: 1mS. Current Output Compliance: +/-12Vdc. Voltage Output Drive: 5mA max. 8-bit ADC Analog output signal readback. Isolation 500Vac, output common to system ground. Current output burnout protected to 250Vac. Power requirements: 2.1W. D7710 Digital Inputs 15 Digital Inputs. Internal 10K pull-up resistors on each bit. Accept direct switch closure. Logic 0 = <1Vdc, Logic 1 = >3.5Vdc. Input burnout to 30Vdc without damage. Isolation 500Vac, input common to system ground. Power requirements: Serial = 0.75W. D7720 Digital Outputs 15 Open-collector outputs to 30Vdc, 100mA max. Vsat: +0.3Vdc max. at 100mA. Short circuit protection to 500mA. Digital Output update rate, 4.5Hz. Isolation 500Vac, output common to system ground. Power requirements: 1.0W. D7730 Digital Inputs/Outputs 7 Inputs, 8 outputs to 30Vdc, 100mA max. Outputs, Vsat: +0.3Vdc max. at 100mA. Short circuit protection to 500mA. Digital Output update rate, 4.5Hz. Isolation 500Vac, output common to system ground Power requirements: 1.0W.

GENERAL DESCRIPTION (Continued) The D7000 series modules communicate with a host computer using the Modbus TCP/IP ethernet protocol. The Modbus TCP/IP ethernet protocol is widely recognized throughout the data acquisition industry and supported by almost all commercially available process control programs and supervisory host computers and PLC s. The key to the DGH product concept is that the modules are easy to connect and use. You do not need engineering experience in complicated data acquisition hardware. With the DGH modules, anyone familiar with a personal computer can construct a data acquisition system. This modular approach to data acquisition is very flexible, easy to use and cost effective. The modules can be mixed and matched to fit your application. They can be placed remote from the host and from each other. ANALOG INPUT MODULES The D7100 through D7400 series analog input modules contain seven input channels and makeup a complete data acquisition system. Each unit contains analog signal conditioning circuits optimized for a specific input type. The amplified sensor signals are converted to digital data with a microprocessor-controlled integrating A/D converter. Offset and gain errors in the analog circuitry are continuously monitored and corrected using microprocessor techniques. The analog input modules output the resultant digital data as unsigned integer percentage of full-scale values that are compatible with the Modbus RTU protocol. The modules continuously convert data at the rate of up to 25 conversions per second and store the latest result in a buffer. Host processors may request data by sending a Modbus query to the module. The D7000 series modules will instantly respond by communicating the memory buffer data back to the host processor. ANALOG OUTPUT MODULES The D7500 analog output modules contain two 12-bit digital to analog converters (DAC) for generating either voltage or current output signals. The output signal type for each DAC is user selectable and each DAC is independently controlled via a host computer using the Modbus RTU protocol. Two voltage and two current ranges are available. The D7500 analog output modules also contain programmable features such as output slew rate, a communications watchdog timer, programmable startup signal value, and an 8-bit analog to digital converter for analog read back the output signal. The communications watchdog timer can be used to move the analog output signal to a known safe condition in the event of a communications failure. DIGITAL INPUT MODULES The D7710 digital input modules contain fifteen individual signal inputs for monitoring logic levels, contact closures, or other ON/OFF signals in a data acquisition system. Each discrete input terminal contains a pull-up biasing resistor allowing for direct connection to a set of contacts. The input terminals can accept signals between 30Vdc without damage. DIGITAL OUTPUT MODULES The D7720 digital output modules contain fifteen individual open-collector transistor outputs for controlling annunciators, lamps, or other devices that require an ON/OFF signal. The digital output modules also contain programmable features such as a communications watchdog timer and programmable startup signal values for each bit. The communications watchdog timer can be used to move the digital output signals to a known safe condition in the event of a communications failure. DIGITAL INPUT/OUTPUT MODULES The D7730 combination digital input/output module contains eight digital inputs and seven open-collector digital outputs. The digital outputs can be used to control annunciators, lamps, or other devices that require an ON/OFF signal. The digital inputs can be used for sensing contact closures The module also contains a programmable communications watchdog timer and user-programmable startup signal values for each digital output. The communications watchdog timer can be used to move the digital output signals to a known safe condition in the event of a communications failure. COMMUNICATIONS The D7000 series modules are designed to easily interface with Ethernet networks. The network interface supports both 10Mbs and 100Mbs connections. All communications to and from the module are performed using the Modbus TCP/IP protocol via an RJ-45 Ethernet interface. PROCESS CONTROL SOFTWARE Modbus TCP/IP protocol is one of the most widely supported serial protocols in the data acquisition market. Modbus TCP/IP software drivers are available for almost every data acquisition software program available today. Thus providing instant connectivity between the D7000 modules and most data acquisition software programs. SETUP The D7000 series are initiated at the factory using the Modbus TCP/IP protocol. Features such as the Modbus device address, baud rate, and analog signal ranges can be easily configured using the DGH setup software. Each D7000 module must be properly configured before installation into a Modbus system.

UTILITY SOFTWARE Complimentary Utility Software is included with each purchase order. The software is compatible with Windows operating systems and distributed on CDROM. The Utility Software simplifies configuration of all user selectable options such as device address, baud rate and filtering constants. The latest version of our software is always available on our web site at. MODBUS COMMAND SET The D7000 series modules use the Modbus TCP/IP protocol for communications. The Modbus TCP/IP binary protocol uses a master-slave technique, in which only the master device can initiate transactions. The slave devices respond by supplying the requested data to the master or by performing the requested action in the query. The master can address any slave device. The returned messages are considered response messages. The supported master function codes are: Modbus TCP/IP Functions and Descriptions 01 Read Coil Status 02 Read Register Status 03 Read Holding Registers 04 Read Input Register (Analog Inputs) 05 Force Single Coil 06 Preset Single Register 0F Force Multiple Coils 10 Preset Multiple Registers STANDALONE FEATURES The D7000 series modules offer several standalone features for communicating data values to different locations and online cloud services. PEER-TO-PEER (P2P) MODE The D7000 series modules support analog input to analog output or digital input to digital output over an IP network without the need to send data to a host computer. P2P transmissions are actively triggered by time interval. Using existing Ethernet lines signals can be transmitted to a remote site without the need for controllers or software programming. One module can pair with another module or multiple modules to one module or one module to multiple modules. CLOUD COMPUTING The D7000 series cloud computing feature uploads information to the cloud using ThingSpeak which is an opensource IOT platform and application programming interface (API) to store and retrieve data using the HTTP protocol. EMAIL NOTIFICATION The D7000 series analog input modules provide email notification of limits via the free email service GMAIL. Limits may be set by the user on each of seven input channels. The user can specify greater, less than, or equal to the desired limit value.

ORDERING GUIDE MECHANICAL DIMENSIONS Voltage Inputs D7100 7Ch Voltage, Thermocouple/Ethernet Current Inputs D7200 7Ch +/-20mA Input/ Ethernet Thermocouple Inputs D7300 7Ch Thermocouple/ Ethernet Voltage, Thermocouple, Current Inputs D7400 7Ch Voltage, Thermocouple, Current/Ethernet Voltage and Current Analog Outputs D7500 2Ch Voltage, Current Analog Output/Ethernet Digital Inputs/Outputs D7710 15-Bit Digital Input/Ethernet D7720 15-Bit Digital Output/Ethernet D7730 7-Digital Inputs, 8-Digital Outputs/Ethernet The D7000 series modules can be easily adapted to a DIN rail using the DGH MK-1 mounting kit shown in view above. CONTACT INFORMATION STANDARDS AND MARKINGS DGH Corporation P.O. Box 5638 Manchester, NH 03108 Ph: (603) 622-0452 Fax: (603) 622-0487 Eml: information@dghcorp.com Web: http:///