Managed Rack PDU MPH2 More efficient Simpler Better

Similar documents
Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Rack PDU Marketing Playbook

Liebert MPH TM Managed Rack-PDU Systems monitoring and control

RACK POWER DISTRIBUTION FOR CRITICAL IT EQUIPMENT. Rack PDU Solutions

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00290, AUGUST 3, Release Notes Section Outline

Emerson Network Power Rack PDU Solutions Rack Power Distribution For Critical IT Equipment. AC Power For Business-Critical Continuity

Cable Management Roof Cabling

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00109, SEPTEMBER 8, Release Notes Section Outline

Polar PDUs POWER MANAGEMENT

SmartMod Intelligent, Integrated Infrastructure for the Data Center

ipdu Pocket Guide INTERNATIONAL

Liebert HPC. Freecooling Scroll Chillers for the Efficient Cooling of Data Centers

Liebert NXC from 10 to 200 kva

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13

Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord

VERTIV. RPC2 Communications Module Release Notes FIRMWARE VERSION _00245, FEBRUARY 19, Release Notes Section Outline

CS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)

Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY

Intelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Innovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s

Liebert PDX. The Cooling Solution for Small and Medium Data Centers. Digital Scroll. Part Load. Competent Partner Efficiency

ipdu Pocket Guide NORTH AMERICA

CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.

Emerson Network Power Technology and Solutions for a World in Action

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

How do I... If you manage a datacenter, we have a solution for you. Sentry : Cabinet Power Distribution Unit Product Family : Metered CDU.

5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA

Liebert exm UPS kva/kw Efficient, Flexible Power Optimized for Midsize Applications FLEXIBLE. ECONOMICAL. INTELLIGENT

Frequently Asked Questions

Liebert. APM from 30 to 300 kw. The Compact Row Based UPS With FlexPower Technology

CS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)

Basic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

CS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)

ipdu Pocket Guide INTERNATIONAL

25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA

Tripp Lite PDUs POWER DISTRIBUTION UNITS. Reliable rack power distribution for high-density IT environments. Introduction 2-3.

The -3Ph extension on a product indicates a 3 Phase power product.

PDU. InfraPower POWER AUSTI AUSTIN AUSTIN AUSTIN 3 PHASE WSI WI WS W MD BASIC. Enclosure Power Management Solutions

Emerson Network Power RPC2 Communications Module Release Notes Version _98733 Firmware July 1, 2016

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU

PE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement

G GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number

Liebert 80-eXL from 160 to 500 kw. Enhanced Design and Improved Efficiency

Models. Specifications

Switched, Outlet Level Monitoring

Chloride CROSS Rack 16 A, 32 A and 63 A

Solutions for Business-Critical Continuity. Emerson Network Power Technology and Solutions for a World in Action

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Liebert PDX from 15 to 120 kw

PDU Inspired by Your Data Center. W IEC PDU Series

Modular PDU Smart metering for your IT

How do I... If you manage a datacenter, we have a solution for you.

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Liebert MicroPOD 230V

Liebert AFC from 500 to 1450 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

ECO PDU Power Distribution Unit

PN5212/PN5320/PN7212/PN7320

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 400V

DS Series Solutions Integrated Solutions for Secure, Centralized Data Center Management

PE8216/PE8324. Energy Intelligence Solutions

Power Distribution Units for Data Centers

Precision Cooling for Business-Critical Continuity. Liebert HPC-S. Designed for the Efficient Cooling of Small Data Centers

Intelligent W Series : 3 - Phase 208V 20A / 30A. Inspired by Your Data Center

QuickSpecs. HP Intelligent Power Distribution Unit (ipdu) Overview

Liebert. EXS from 10 to 20 kw. Optimized and integrated three-phase UPS solution with high efficiency power protection

Higher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.

PDU - Overview / Non-Intelligent PDU s

Emerson Network Power MPH2 Rack PDU

Product brochure. Eaton epdu G3. Simplify installation. Enhance operation. Maximize control.

APMTM UPS 18kW - 90kW The Flexpower Technology for mission critical applications

Engineering and Manufacturing Excellence in Data Centre Infrastructure

ECO PDU PE7108/PE7208

Product Brochure. Eaton epdu G3 Managed

Power Distribution Unit

Product Brochure. Eaton epdu G3 Managed

ECO PDU. Features. PE5220sA

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Knürr CoolAdd The universal retrofit solution against overheating in server racks. Rack & Enclosure Systems

Inspired by Your Data Center. Intelligent W Series : 3 - Phase 208V

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

Liebert NXC from 10 to 60kVA

QuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview

ECO PDU PE5108/PE5208

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Emerson Network Power Rack PDUs. Rack PDUs. Liebert MPXTM Liebert MPHTM Knürr DI-STRIP Inline Metering (IMS)

THE NEW WORLD OF IT INFRASTRUCTURE SOLUTIONS. Enabling an IT Infrastructure as Dynamic as Your Business

Rack Power Distribution. Rack power distribution offerings for entry-level networking equipment and high-density server and blade environments

THE OFFICIAL TRADE JOURNAL OF BICSI

Power Distribution. For technical support call Online catalog available at leviton.com 461

ARE YOUR RACK PDUS KEEPING YOU FROM OPTIMIZING POWER MANAGEMENT?

Inspired by Your Data Center. 1-Phase Intelligent PDU US NEMA Outlet 110V

Features and Benefits: Power IQ DCIM Monitoring Solutions

Power IQ for econnect

Transcription:

Managed Rack PDU MPH2 More efficient Simpler Better

MPH2 Managed Rack PDU The newly developed Managed Rack PDU MPH2 TM is a power supply system with monitoring and control functions. Standout features of the MPH2 TM are simple integration into rack and management architectures along with the highest levels of availability and energy efficiency. The housing comprises a compact aluminum profile, allowing easy, space-saving installation in Knürr racks or in other housing systems. Depending on the model, the MPH2 TM can be installed vertically or horizontally (19"). Display Special features: Extensive measurement and switching functions with high measurement accuracy of up to ± 1 % up to output port level. Slim profile Circuit Breaker Easy integration into Trellis TM or other available DCIM systems. The compact design with an ultraflat circuit breaker minimizes the amount of space needed in the rack. Simple mounting without tools for different rack systems. Can also come installed in Knürr racks on delivery. Highest possible security and availability with an operating temperature of up to +60 C. Highest level of energy efficiency with power losses of less than 5 W, even in switchable models. The input cable can be securely connected. Patented cable entry system, flexible cable routing in all directions. Patented flexible power cord entry 2

Input Power 16 to 32A (EU) Single phase and three phase Output Configurations IEC-C13 and IEC-C19 Combinations possible Modularity Communication card External Display External Sensors Monitoring Input level Branch level Output level Temperature and Humidity Door contacts and Input contacts Remote Socket Control Output level Managed Rack PDU MPH2 TM is used for easy monitoring and controlling of the power supply in server racks.

MPH2 Monitoring and Control of the Systems Benefits Highest availability levels Modular communications card; can be replaced during ongoing operation. This simplifies maintenance and increases the level of availability. Bi-stable relays in switchable designs; the server is always supplied power, even in the event of faults. Software-controlled overload protection affected outputs are switched off before the advance fuse is activated. Additional measurement of the neutral conductor and of the crest factor; possible faults that cause switch-off are already detected in advance. Sector-leading management properties Securely integrated local display and an optional external display offering flexibility in local management. An onboard web interface and CLI/SSH interface, both equally suitable for Windows and Linux administration. A variety of authentication options and encrypted protocols ensure integration into Enterprise Security architectures. SNMPv3 and IPv6 support so that topical requirements, particularly from the public sector, can be satisfied. State-of-the-art technology in many areas Operating temperatures of up to 60 C allow secure operation in the warm aisle. A measurement accuracy of +- 1 % ensures reliable measurement results. Power losses of less than 5 W, even in switchable models, reduce electricity costs and minimize the thermal load. Simple integration into ENP solutions Can be delivered already installed in Knürr racks to save time and costs during installation in the data center. Serial integration into Avocent UMG, ACS and MPU guarantees redundant management access to the MPH2 TM. Integration into ENP software solutions; the MPH2 TM is therefore part of a full DCIM solution with monitoring and control functions. 4

MPH2 Integration into Knürr DCM Rack Patented rack fastening without tools Locking of the server connecting cables Modular Communications Card RPC-2k Web, CLI, sensor, USB, display array interfaces Display Measurement per phase, group and output, switching per output Ultraflat circuit breakers Patented flexible cable entry 5

MPH2 Rack PDU Power Management and Monitoring Interfaces Avocent ACS 6000 Advanced Console Server Sensors (up to 10) RPC2-BDM Local Display Avocent MergePoint Unity RPC2 Communications Card Avocent Universal Management Gateway Liebert Nform 3 rd party apps (SNMP) Avocent DS View 4 Avocent Rack Power Manager Up to 4 rack PDUs in Power Array Trellis Emerson Network Power Rack PDUs support all major industry-standard management, authentication and encryption standards and protocols, and they fully integrate into Emerson Network Power s industry-leading KVM, serial console and infrastructure management systems. Plus, they integrate rack level power and environmental monitoring information from the PDUs with higher level data center management software provided by Emerson or third parties. Infrastructure Management Avocent Rack Power Manager software Centralized configuration, event logging and management of all Rack PDU s Centralized permissioning and remote authentication leveraging Active Directory, LDAP, Radios, Kerberos etc. Grouping capabilities for power control or for power consumption reports Canned and custom power consumption reports with scheduling option Secure Web/SNMP Interfaces User configured alarm thresholds High alarm warning:: low alarm Receptable state and sequencing configuration Electrical metering Rack PDU Array Device consolidation use a single IP for up to four rack PDUs, with MPX and MPH2 PDUs on the same private network PDU Explorer Intuitive hierarchical interface View PDU status by strip or receptacle Device Explorer Browsing by user defined device name Liebert SiteScan Web Centralized monitoring software Provides real-time monitoring and control Liebert Nform IT Based Centralized Monitoring Software Trending of power Receptacle group control Monitoring anywhere you need it From the individual receptacle of each discrete device to the complete rack PDU, monitoring is available to meet user needs. Displays are designed for easy user location to fit changing site needs. Display and sensors are designed for easy mounting on the rack. A single display can manage up to four MPX or MPH2 systems and associated monitoring accessories. Optional Hardware RPC2-BDM Local Display Module Electrical and environmental parameters One RPC2-BDM supports up to 4 PDUs on array PDU explorer Device Explorer Liebert SN Family Of Rack Sensors Modular and integrated systems Temerature, humidity and contact probes Auto-config no set-up required 6

MPH2 Equipment models in Europe Data sheet MPH2 EMEA MPH2 B MPH2 C MPH2 M MPH2 R Function Form Factor Unit Metered Unit Metered Outlet Switched 0U,1U Outlet Metered Unit Metered Outlet Switched Mounting Preinstalled Toolless brackets Universal Mounting bracket Ability to ship PDU preinstalled in Emerson Racks Input Power Options Input Wiring Options Max. Capacity Outlet options Maximum Outlets 230V 1-ph 16A/32A 230/400V 3-ph 16A/32A 3m pluggable power cord / hardwired 22,2kW IEC320 C13, C19, Locking capability on all outlets Strip Metered: 42 Outlet Metered and / or Switched: 24 Metering Levels Input, Phase, Branch Input, Phase, Branch Input, Phase, Branch Outlet Input, Phase, Branch Outlet Parameters Measured Volts, Current, kw, kva, Power Factor, Crest Factor, Frequency Metering Accuracy +/-1 % Switching Capability N/A On, Off, Recycle, Lock, Unlock, Outlet Grouping Capability N/A On, Off, Recycle, Lock, Unlock, Outlet Grouping Capability Modularity Local Management Remote Management SNMP version support Authentication Encryption Communication Card RPC2k Local Display, Optional Remote Display Onboard Web Interface; CLI; SNMP; SSH; Telnet Integration with Avocent ACS, UMG&MPU; Integration with DSView; Rack Power Manager, NformTM&TrellisTM v1,v2 and v3 Local; Remote: Active Directory, LDAP, TACACS, Radius, Kerberos MD5, AES, DES Operating Temp. Range 0 C to 60 C Storage Temp. Range -25 C to 85 C Relative Humidity 5 % to 95 % Overcurrent Protection Idle Power Consumption 0U units Width x Depth 0U units Length Product Compliance Agenncy Approvals Software Electronic Overcurrent Protection 100 % Rated 20A Branch Overcurrent Protection - Hydraulic Magnetic Circuit Breakers 3W-5W 56 mm x 50 mm 916,5 mm / 1004mm / 1736,5 mm / 1826,5 mm CE, RoHS, REACH, WEEE, EMC, LVD BV-BG, CB 7

As at: November 2013 / Version 1.0 About Emerson Network Power Emerson Network Power, a business of Emerson (NYSE:EMR), delivers software, hardware and services that maximize availability, capacity and efficiency for data centers, healthcare providers and industrial facilities. A trusted industry leader in smart infrastructure technologies, Emerson Network Power provides innovative data-center infrastructure management solutions that bridge the gap between IT and facility management and deliver efficiency and uncompromised availability regardless of capacity demands. Our solutions are supported around the world by local Emerson Network Power service technicians. Learn more about Emerson Network Power products and services at: www.emersonnetworkpower.eu Emerson Network Power Global Headquarters 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229, USA T +1 614 8880246 Emerson Network Power EMEA Mariakirchener Straße 38 94424 Arnstorf, Germany T +49 8723 27 0 F +49 8723 27 154 info@knuerr.com Emerson Network Power United Kingdom George Curl Way Southampton SO18 2RY, UK T +44 (0)23 8061 0311 F +44(0)23 8061 0852 UK.Enquiries@Emerson.com While every precaution has been taken to ensure the accuracy and completeness of this brochure, Emerson Network Power and/or its affiliates makes no representations or warranty about its accuracy, reliability, completeness, or timeliness and disclaims any and all liability for damages resulting from the use of this information or for any errors or omissions. 2013 Emerson Network Power. All rights reserved. Specifications subject to change without notice. MKA4LOUKMPH2 Emerson, Business-Critical Continuity and Emerson Network Power are trademarks of Emerson Electric Co. or one of its affiliated companies. 2013 Emerson Electric Co. 1101.150.111 MPH2 Subject to technical changes, errors and omissions.