EFFECTIVE DOSE RATIOS FOR TOMOGRAPHIC AND STYLIZED MODELS FROM EXTERNAL EXPOSURE TO PHOTONS

Similar documents
Tomographic Anthropomorphic Models. Part IV: Organ Doses for Adults due to Idealized External Photon Exposures

Comparison of internal and external dose conversion factors using ICRP adult male and MEET Man voxel model phantoms.

State of the art of voxel phantom development

Av. Professor Lineu Prestes São Paulo, SP ABSTRACT

Anthropomorphic Phantoms

ICRP Symposium on Radiological Protection Dosimetry

Absorbed fractions in a voxel-based phantom calculated with the MCNP-4B code

Towards patient specific dosimetry in nuclear medicine associating Monte Carlo and 3D voxel based approaches

Computational Phantoms of the ICRP Reference Male and Reference Female

FASH and MASH: Female and Male Adult human phantoms based on polygon mesh surfaces Part II: Dosimetric calculations

OBJECT ORIENTED DESIGN OF ANTHROPOMORPHIC PHANTOMS AND GEANT4-BASED IMPLEMENTATIONS ABSTRACT

IMPLEMENTATION OF SALIVARY GLANDS IN THE BODYBUILDER ANTHROPOMORPHIC PHANTOMS

GSF MALE AND FEMALE ADULT VOXEL MODELS REPRESENTING ICRP REFERENCE MAN THE PRESENT STATUS

MEASUREMENTS OF AIR KERMA AS FUNCTION OF POTENTIAL IN X-RAY TUBES FOR ESTIMATES STANDARD QUANTITIES USED FOR DOSIMETRIC EVALUATION

MODELLING RADIATION TRANSPORT IN VOXEL GEOMETRIES WITH THE MONTE CARLO CODE MCNPX

Construction of Voxel-type Phantom Based on Computed Tomographic Data of RANDO Phantom for the Monte Carlo Simulations

Absorbed Fractions for Multi-Region Models of the Kidneys in ICRP/ICRU Voxel Phantoms

Development and Use of Computational Anthropomorphic Phantoms for Medical Dosimetry Nina Petoussi-Henss

Voxel phantoms and Monte Carlo methods applied to internal and external dose calculations.

Katja the 24 th week of virtual pregnancy for dosimetric calculations

GSF Male and Female Adult Voxel Models Representing ICRP Reference Man

Three Dimensional Dosimetry Analyses In Radionuclide Therapy Using IDL And MCNP-based Software Tools

ELECTRON DOSE KERNELS TO ACCOUNT FOR SECONDARY PARTICLE TRANSPORT IN DETERMINISTIC SIMULATIONS

Michael Speiser, Ph.D.

ANALYSIS OF CT AND PET/SPECT IMAGES FOR DOSIMETRY CALCULATION

Medical Physics Research Center, Mashhad University of Medical Sciences, Mashhad, Iran.

Outline. Monte Carlo Radiation Transport Modeling Overview (MCNP5/6) Monte Carlo technique: Example. Monte Carlo technique: Introduction

Monte Carlo methods in proton beam radiation therapy. Harald Paganetti

Electron Dose Kernels (EDK) for Secondary Particle Transport in Deterministic Simulations

DRAFT TO BE SUBMITTED TO HEALTH PHYSICS JOURNAL

4. Conclusions. 5. References

Attenuation Coefficients for Layered Ceiling and Floor Shields in PET/CT Clinics

Mesh Human Phantoms with MCNP

Deformation of mesh-type ICRP reference computational phantoms in different statures and postures for individualized dose calculations

Proton dose calculation algorithms and configuration data

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

Image-based Monte Carlo calculations for dosimetry

THE SIMULATION OF THE 4 MV VARIAN LINAC WITH EXPERIMENTAL VALIDATION

Shielding factors for traditional safety glasses

Monte Carlo Simulations for In Vivo Internal Dosimetry (including phantom development)

Limitations in the PHOTON Monte Carlo gamma transport code

Modeling the ORTEC EX-100 Detector using MCNP

SHIELDING DEPTH DETERMINATION OF COBALT PHOTON SHOWER THROUGH LEAD, ALUMINUM AND AIR USING MONTE CARLO SIMULATION

Suitability Study of MCNP Monte Carlo Program for Use in Medical Physics

Development and anatomical details of Japanese adult male/female voxel models

Evaluation of RayXpert for shielding design of medical facilities

Assesing multileaf collimator effect on the build-up region using Monte Carlo method

Application of MCNP Code in Shielding Design for Radioactive Sources

DUAL energy X-ray radiography [1] can be used to separate

Computer-assisted segmentation of CT images by statistical region merging for the production of voxel models of anatomy for CT dosimetry

Dosimetry Simulations with the UF-B Series Phantoms using the PENTRAN-MP Code System

UNCOMPROMISING QUALITY

TWENTY YEARS OF VISUAL MONTE CARLO

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Monte Carlo Simulation for Neptun 10 PC Medical Linear Accelerator and Calculations of Electron Beam Parameters

Hidenobu Tachibana The Cancer Institute Hospital of JFCR, Radiology Dept. The Cancer Institute of JFCR, Physics Dept.

DUAL-ENERGY CT IN PROTON THERAPY

CT vs. VolumeScope: image quality and dose comparison

Graphical User Interface for Simplified Neutron Transport Calculations

Improvement in the calibration techniques of approved dosimetry services in Spanish nuclear power plants of whole body counters with NaI detectors.

Geant4-DICOM Interface-based Monte Carlo Simulation to Assess Dose Distributions inside the Human Body during X-Ray Irradiation

Mathematical methods and simulations tools useful in medical radiation physics

METHODOLOGY FOR CONVERTING CT MEDICAL IMAGES TO MCNP INPUT USING THE SCAN2MCNP SYSTEM

OPTIMIZATION OF MONTE CARLO TRANSPORT SIMULATIONS IN STOCHASTIC MEDIA

Basics of treatment planning II

Development of a mouse computational model for MCNPx based on Digimouse images and dosimetric assays

Author's Accepted Manuscript

SESAME: A NEW TOOL FOR THE NUMERICAL DOSIMETRIC RECONSTRUCTION OF A RADIOLOGICAL ACCIDENT CAUSED BY AN

Production of neutrons in laminated barriers of radiotherapy rooms: comparison between the analytical methodology and Monte Carlo simulations

Automation of an X-ray calibration system using LabVIEW

Library of Mesh and NURBS female phantoms for pulmonary in vivo counting studies

I. INTRODUCTION. Figure 1. Radiation room model at Dongnai General Hospital

Monte Carlo modelling and applications to imaging

Basics of treatment planning II

Wissenschaftliche Highlights der GSF 2007

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Comparison of absorbed dose distribution 10 MV photon beam on water phantom using Monte Carlo method and Analytical Anisotropic Algorithm

Joint CI-JAI advanced accelerator lecture series Imaging and detectors for medical physics Lecture 1: Medical imaging

gpmc: GPU-Based Monte Carlo Dose Calculation for Proton Radiotherapy Xun Jia 8/7/2013

Internal radionuclide dosimetry of model and patient based voxelised phantoms using the GATE toolkit

A SYSTEM OF DOSIMETRIC CALCULATIONS

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Radiology. Marta Anguiano Millán. Departamento de Física Atómica, Molecular y Nuclear Facultad de Ciencias. Universidad de Granada

Automated ADVANTG Variance Reduction in a Proton Driven System. Kenneth A. Van Riper1 and Robert L. Metzger2

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

The Monte Carlo simulation of a Package formed by the combination of three scintillators: Brillance380, Brillance350, and Prelude420.

Ch. 4 Physical Principles of CT

Computational Anthropomorphic Models of the Human Anatomy: The Path to Realistic Monte Carlo Modeling in Radiological Sciences

An image-based skeletal canine model for pre-clinical evaluations of osteosarcoma molecular radiotherapy

Implementation of the EGSnrc / BEAMnrc Monte Carlo code - Application to medical accelerator SATURNE43

Significance of time-dependent geometries for Monte Carlo simulations in radiation therapy. Harald Paganetti

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: A Monte Carlo study

A Monte Carlo shielding model for PET/CT clinics

Dose Point Kernel calculation and modelling with nuclear medicine dosimetry purposes

PROVIDE A UNIFORM DOSE IN THE SMALL ANIMAL.

MODELING MONTE CARLO OF MULTILEAF COLLIMATORS USING THE CODE GEANT4

Radiation Dose Optimization For Critical Organs. Yasaman Khodadadegan

Voxels and Medical Applications. FLUKA Beginners course

The MSKCC Approach to IMRT. Outline

A CT-based Monte Carlo Dose Calculations for Proton Therapy Using a New Interface Program

Transcription:

The Monte Carlo Method: Versatility Unbounded In A Dynamic Computing World Chattanooga, Tennessee, April 17 21, 2005, on CD-ROM, American Nuclear Society, LaGrange Park, IL (2005) EFFECTIVE DOSE RATIOS FOR TOMOGRAPHIC AND STYLIZED MODELS FROM EXTERNAL EXPOSURE TO PHOTONS R. Kramer and H. J. Khoury Departamento de Energia Nuclear Universidade Federal de Pernambuco Av. Prof. Luiz Freire, 1000, Cidade Universitária, CEP 50740-540, Recife, PE, Brazil rkramer@uol.com.br; hjkhoury@globo.com J. W. Vieira Centro Federal de Educação Tecnológica de Pernambuco, CEFET-PE Av. Prof. Luiz Freire, 500, Cidade Universitária, CEP 50740-540, Recife, PE, Brazil jwvieira@br.inter.net H. Yoriyaz Instituto de Pesquisas Energéticas e Nucleares, IPEN-CNEN/SP Av. Prof. Lineu Prestes, 2242, Cidade Universitária, CEP 05508-000, São Paulo, SP, Brazil hyoriyaz@ipen.br F. R. A. Lima Centro Regional de Ciências Nucleares Comissão Nacional de Energia Nuclear R. Cônego Barata 999, CEP 52110-120, Recife, PE, Brazil falima@cnen.gov.br ABSTRACT The development of new, sophisticated Monte Carlo codes, and of tomographic or voxelbased human phantoms motivated the International Commission on Radiological Protection (ICRP) to call for a revision of traditional exposure models, which have been used in the past to calculate organ and tissue as well as effective dose coefficients for stylized MIRD5-type phantoms, and have been released in Publication No. 74 for external exposures to photons. This paper reports about calculations made with the recently developed tomographic MAX (Male Adult voxel) and FAX (Female Adult voxel) phantoms, as well as with the gender-specific MIRD5-type phantoms ADAM and EVA, coupled to the EGS4 and to the MCNP4C Monte Carlo code, for external whole-body irradiation with photons for anterior-posterior, posterior-anterior, and rotational incidence for energies between 10 kev and 10 MeV. Effective doses for the tomographic and for the stylized exposure models will be compared separately as function of the replacement of the Monte Carlo code, of human tissue compositions, and of the stylized by the tomographic anatomy. The results indicate that for external exposures to photons the introduction of voxelbased exposure models is expected to cause a reduction of the effective dose by about 10% for the energies and geometries considered in this study. Key Words: voxel phantoms, Monte Carlo, radiation protection, effective dose

R. Kramer et al. 1 INTRODUCTION Conversion coefficients (CCs) between effective dose and physical quantities characterizing the radiation field have been published by the International Commission on Radiological Protection (ICRP) for external exposures in order to facilitate the interpretation of data measured in routine radiation protection in terms of the primary protection quantity. This primary protection quantity, the effective dose, is the sum of the weighted equivalent doses in all tissues and organs of the body. It is given by the expression E = w T H T, T where H T is the equivalent dose in tissue or organ T and w T is the weighting factor for tissue T [1]. According to Table 1, the ICRP recommends tissue weighting factors for 13 selected tissues and organs, plus one single tissue weighting factor for a so-called remainder, which is composed of another 10 organs and tissues. The quantity H T represents the equivalent dose averaged over the volume of tissue T, which reflects the assumption of a linear dose-risk relationship. Table 1: Tissue weighting factors from ICRP60 [1] Tissue/Organ w T Testes, Ovaries 0.20 RBM, Colon, Lungs, Stomach 0.12 Bladder, Breast, Liver, Oesopagus, Thyroid 0.05 Skin, Bone surface 0.01 Remainder 0.05 Remainder: adrenals, brain, trachea, small intestine, muscle, pancreas, kidneys, spleen, thymus, uterus Mainly the MIRD5-type ADAM and EVA phantoms [2] have been used for the calculations of the CCs for external exposures to photons recommended by the ICRP in its Publication No. 74 [3]. Therefore this investigation presents ratios between CCs calculated on the one hand with the mathematical ADAM and EVA phantoms, and on the other hand with the voxel-based MAX and FAX phantoms in order to show the dosimetric consequences when the stylized exposure models will be replaced by tomographic models. 2.1 The MAX and the FAX phantoms 2 MATERIALS AND METHODS The MAX and FAX phantoms have been developed based on CT images from patients [4,5]. After segmentation the volumes of the radiosensitive organs and tissues have been adjusted in order to match the reference masses defined by ICRP89 [6]. The phantoms have heterogeneously structured skeletons with voxel-specific skeletal tissue compositions based on masses, percentage distributions, and cellullarity factors from ICRP70 [7]. Dosimetrical American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 2/12

Effective dose for tomographic and stylized models from external exposure to photons separation instead of geometrical segmentation allows for the calculation of skin equivalent dose in the 1.5mm surface layer of the MAX phantom, and in the 1.2mm surface layer of the FAX phantom, in spite of 3.6mm voxel thickness. Detailed descriptions of both voxel phantoms are given in Kramer et al [4,5]. Figures 1 and 2 show frontal and lateral views of the MAX and the FAX phantoms, respectively. Figure 1: The MAX phantom Figure 2: The FAX phantom 2.2 The ADAM and EVA phantoms The gender-specific adult MIRD5-type phantoms ADAM and EVA have been taken from Kramer et al [2]. Their organ and tissue masses correspond to the anatomical specifications given by the ICRP in its first Reference Man Report, Publication No. 23 [8]. Figure 3 shows frontal views of the ADAM and the EVA phantoms. Figure 3: The ADAM and EVA phantoms American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 3/12

R. Kramer et al. 2.3 The EGS4 and MCNP4 Monte Carlo codes The EGS4 Monte Carlo code [9] simulates coupled electron-photon transport through arbitrary media. The default version of EGS4 applies an analogue Monte Carlo method, which was used for the calculations of this investigation. Rayleigh scattering has been taken into account, and secondary electrons have been transported, except for the MIRD5-type phantoms when comparisons with data already published by the ICRP were made. The MCNP-4C [10] code is a general purpose Monte Carlo code which simulates neutron, photon and electron transport. Any arbitrary three-dimensional geometry configuration can be defined using first and second-degree surfaces and fourth-degree elliptical tori. The Repeated Structure option permits to model segmented geometries with great flexibility. For photons MCNP-4C takes into account incoherent and coherent scattering, fluorescent emission and pair production. 2.4 Exposure models For any given exposure condition the effective dose CC is primarily a function of the phantom anatomy, of the tissue composition, and of the Monte Carlo code. In order to study the dosimetric effects of these three components separately, the following exposure models have been studied: a) The EGS4 and the MCNP4C Monte Carlo code connected to the ADAM and EVA phantoms with the original tissue composition [2]. b) The EGS4 Monte Carlo code connected to the ADAM and EVA phantoms with ICRU44- based tissue compositions [11]. c) The EGS4 and the MCNP4C Monte Carlo code connected to the MAX and FAX phantoms with ICRU44-based tissue compositions [11], and ICRP70-based skeletal tissue distribution [7]. 3 RESULTS ICRP Publication 74 [3] presents CCs between equivalent dose to radiosensitive body organs and tissues, as well as effective dose, and air kerma free-in-air calculated with the GSF Monte Carlo code [12] connected to the ADAM and EVA phantoms for external exposures to photons as function of the radiation energy, and for different directions of incidence. In this study the same CCs have been calculated with the EGS4 and the MCNP4C Monte Carlo codes with broad parallel beams covering the whole body for anterior-posterior (AP), and for posterior-anterior (PA) incidence, as well as for a broad parallel beam rotating 360 around the phantom s vertical axis (ROT) for the ADAM-EVA and for the MAX-FAX phantoms. Secondary electrons have been persued only for the MAX-FAX/EGS4 exposure model, i.e. generally equivalent doses have been calculated as kerma averaged over the volumes of the organs and tissues of interest. The effective dose was determined as recommended by the ICRP [3]. The remainder equivalent dose was calculated as the arithmetic average of the individual remainder organ contributions. If the coefficient of variance (CV) of an organ or tissue mentioned in Table 1 was greater than 30%, then its equivalent dose was disregarded. American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 4/12

Effective dose for tomographic and stylized models from external exposure to photons 3.1 Replacement of the Monte Carlo code For the ADEV (ADAM and EVA) phantoms Figure 4 presents ratios between effective doses calculated with the EGS4 and the GSF Monte Carlo code, and calculated with the MCNP4 and the GSF code, respectively, as a function of the photon energy for AP- and PA-incidence. The CVs of the effective doses were 2-3% for the ICRP74 data, smaller than 1% for the EGS4, as well as for the MCNP4 code for photon energies above 30 kev. Figure 4 shows that in this range of energies the average difference between the ICRP74-CCs and the EGS4-CCs is ca. 1% for both directions of incidence, and about 5.3% and 3.8% between the ICRP74-CCs and the MCNP4-CCs for AP- and PA-incidence, respectively. For incident energies between 10 and 30 kev the average difference increases to about 10% for the EGS4/ICRP74 ratios, and to about 20-38% for the MCNP4/GSF ratios, which is caused by fluctuations of equivalent dose due to low numbers of interactions, especially in small organs, like the testes, the ovaries, and by rounding error effects (see also the next section). Ratio of effective doses 1.4 1.2 1 0.8 0.6 EXTERNAL EXPOSURE TO PHOTONS ADEV-EGS4 / ADEV-ICRP74 ADEV-MCNP4C / ADEV-ICRP74 0.4 30 kev 0.01 0.1 1 10 Photon Energy (MeV) AP-EGS4 PA-EGS4 AP-MCNP4C PA-MCNP4C Figure 4: Replacement of the Monte Carlo code 3.2 The replacement of the tissue compositions Tissue compositions used for the ICRP74 CCs are shown in the ADEV columns 2 5 of Table 2, except for some small fractions for heavier elements. In the ADAM and EVA phantoms the soft-tissue composition was not only used for organs, like the liver, the stomach, the pancreas, etc., but also for the unspecified regions surrounding the organs, the lungs, and the skeleton, which in real humans are mostly filled with adipose and muscle. The new tissue compositions shown in the ADEV44 columns 6 11 of Table 2 are based on data provided by ICRU44 [11], and additionally the skeletal mixture was designed to contain 11.3% of calcium as recommended by ICRP70 [7]. As the ADAM and EVA phantoms have no separately segmented regions for adipose and muscle, homogeneous mixtures ADIMUSM and ADIMUSF of the two American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 5/12

R. Kramer et al. tissues were defined based on their mass ratios in the MAX and FAX phantom, respectively. The ICRP23-based RBM masses, RBM mass fractions, and the calculational RBM model of the ADEV phantoms have not been changed a this stage. Ratios between the ADEV44 and the ADEV effective doses are presented in Figure 5, which show an increase of the effective dose caused by the replacement of the tissue compositions of up to 9% for all directions of incidence, and for energies above 30 kev. Below 30 kev the data are sometimes not very accurate, because especially small organs with great tissue weighting factors, like the testes and the ovaries, have large CVs, and also rounding error effects effects can impair the accuracy of the effective doses. According to Figure 5 for PA-incidence and a photon energy of 15 kev, for example, the ratio between the ADEV44 and the ADEV effective dose shows a value of 1.17 calculated by the algorithm attached to the Monte Carlo code. As the absolute values of Table 3. Tissue compositions for the ADEV and the ADEV44 phantoms ELEMENT SOFT SKIN LUNGS SKEL SOFT SKIN LUNGS SKEL ADIMUSM ADIMUSF ADEV ADEV ADEV ADEV ADEV44 ADEV44 ADEV44 ADEV44 ADAM44 EVA44 [%] [%] [%] [%] [%] [%] [%] [%] [%] [%] H 10 10.2 10 7 10.5 10 10.3 7.2 10.6 10.8 C 23 26.9 10 23 12.5 20.4 10.5 31.3 30.8 37.1 N 2.3 4.3 2.8 3.9 2.6 4.2 3.1 3.2 2.4 2.1 O 63 58 76 49 73.5 64.5 74.9 41.1 55.4 49.4 Na 0.13 0.01 0.2 0.32 0.2 0.2 0.2 0.1 0.1 0.1 Mg 0.015 0.005 0.007 0.11 0.1 P 0.24 0.3 0.08 6.9 0.2 0.1 0.2 5.3 0.128 0.1 S 0.22 0.15 0.23 0.17 0.18 0.2 0.3 0.25 0.227 0.2 Cl 0.14 0.25 0.27 0.14 0.22 0.3 0.3 0.1 0.1 0.1 K 0.21 0.1 0.2 0.15 0.21 0.1 0.2 0.05 0.245 0.2 Ca 0.14 0.007 9.9 0.01 11.3 Fe 0.006 0.002 0.04 0.008 0.01 ρ [gcm -3 ] 0.98 1.105 0.296 1.486 1.05 1.09 0.26 1.469 1.012 1.00 SOFT = SOFT TISSUE, SKEL = SKELETON, ADIMUSM (F) = 36.2% (50.7%) ADIPOSE + 63.8% (49.3%) MUSCLE the effective doses are small for this energy, typically ca. 0.015 Sv/Gy, rounding error effects can lead to false ratios, because a re-calculation by hand without rounding the organ and tissue equivalent doses to 3 digits gave a ratio of 1.098, and consequently the PA-ratio of the effective doses would rather follow the curve PAcorr shown in Figure 5. Therefore with regard to data interpretation for external exposures to photons one has to bare in mind that for incident particle energies below 30 kev the CCs can show significant variations because of statistical fluctuations of equivalent dose to small organs, and because of rounding errors effects even for equivalent doses with small CVs. American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 6/12

Effective dose for tomographic and stylized models from external exposure to photons Ratio of effective doses 1.2 EXTERNAL EXPOSURE TO PHOTONS 1.15 EGS4 1.1 1.05 1 0.95 ADEV44 / ADEV 0.9 30 kev 0.01 0.1 1 10 Photon Energy (MeV) AP PA ROT PAcorr Figure 5: Replacement of the tissue compositions 3.3 Replacement of the anatomy The replacement of the stylized MIRD5 bodies by real human bodies was done in two steps: First homogenized versions of the MAX and the FAX phantoms, called MAXHOM and FAXHOM, have been designed, each of which contains a homogeneous skeleton, and homogeneous mixtures of adipose and muscle, with tissue compositions shown in columns 6 11 of Table 2, and still with the ICRP23-based RBM model. In terms of the elemental compositions of tissues, of their distribution throughout the body, and of the RBM model the ADAM44 and the MAXHOM, and the EVA44 and the FAXHOM phantoms are equivalent, and consequently all differences of equivalent doses between the the two pair of phantoms are expected to be caused by their different geometrical anatomies only, i.e. differences with regard to the volume, the form, and the location of organs and tissues. Figure 6 presents ratios between effective doses for the two tissue-equivalent pair of phantoms for AP-, PA-, and ROT-incidence,and as a function of the incident photon energy between 10 kev and 10 MeV, with ICRU44-based tissue compositions and ICRP23-based RBM models applied to all of them. ADEV44 represents the ADAM44 and the EVA44 phantoms, while MHOM-FHOM stands for the MAXHOM and the FAXHOM phantoms. The curves show that the introduction of real human anatomies leads to a decrease of the effective dose of more than 30% for photon energies above 30 kev. The data for energies between 10 and 30 kev should be considered with caution, taking into account the considerations presented at the end of the previous section about CVs and rounding error effects. American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 7/12

R. Kramer et al. Ratio of effective doses 1.2 1.1 1 0.9 0.8 0.7 EXTERNAL EXPOSURE TO PHOTONS EGS4 MHOM-FHOM / ADEV44 0.6 30 kev 0.01 0.1 1 10 Photon Energy (MeV) AP PA ROT Figure 6: Replacement of the anatomy The effective dose is the sum of weighted equivalent doses to 23 organs and tissues, whose size, form, and location relative to each other determine a complex distribution of their equivalent doses as a function of the radiation energy and direction of incidence. In order to understand the effective dose decreases shown in Figure 6 as consequence of the transition from the stylized MIRD5 to the real voxel anatomy, one should observe some general anatomical differences between the two types of phantoms from a comparison of Figures 1 and 2 with Figure 3: The trunks of the ADEV44 phantoms are elliptical cylinders with integrated arms and constant thicknesses of 20cm (18.8cm)* sagittal, and 40cm (37.6cm) lateral, while the MAXHOM-FAXHOM phantoms body thicknesses vary between 20-24cm (19.5-22cm) sagittal, 50-52cm (43-45cm) lateral in the regions of the upper arms, and 30-33cm (29-31cm) in the abdominal regions, where the lower arms and hands are separated from the trunk. (* numbers in brackets for EVA44 and FAXHOM, respectively) Compared to the mathematical skeleton of the ADEV44 phantoms, MAXHOM and FAXHOM have naturally structured skeletons with sterni, quite differently shaped pelvises, and the natural structure of their ribcages seems to provide more shielding to internal organs. Often the skeletons and internal organs of the MAXHOM and FAXHOM phantoms are surrounded by thicker layers of adipose and muscle compared to the ADEV44 phantoms. Last but not least one has to analyze the anatomical reasons for the change of the effective dose organ by organ. This, however, is beyond the scope of this paper, but this kind of information can be found elsewhere [13]. The second step of the transition from the MIRD5-type ADAM and EVA to the voxel-based MAX and FAX anatomies represents the introduction American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 8/12

Effective dose for tomographic and stylized models from external exposure to photons of ICRP70-based masses, mass fractions, and cellullarity factors for the RBM, of the revised correction factors for photo-electrons, of heterogeneously distributed skeletal tissues among the bone voxels, of separately segmented regions of adipose and muscle, and of the transport of secondary electrons. Figure 7 shows ratios between the effective doses for the MAX-FAX and the MAXHOM- FAXHOM phantoms for incident photon energies ranging from 10 kev to 10 MeV for AP-, PA-, and ROT-incidence, respectively. For energies above 30 kev the differences between the two effective doses are in the range of +2% to 4% depending on the energy considered. Although the ICRP70-based RBM distribution can cause greater effective doses for AP- and ROTincidence, the values of the ratios for these directions of incidence for energies below 30 kev have to be considered with caution for reasons already explained earlier. For the MAX-FAX phantoms secondary electrons have been followed down to a cut-off energy of 200 kev. Their effect becomes observable especially for superficial organs, like the testes, the skin, the thyroid, etc. for incident photon energies above 3 MeV, but not for the effective dose. Ratio of effective doses 1.08 1.06 1.04 1.02 1 0.98 0.96 0.94 EXTERNAL EXPOSURE TO PHOTONS EGS4 MAX-FAX / MHOM-FHOM 0.92 30 kev 0.01 0.1 1 10 Photon Energy (MeV) AP PA ROT Figure 7: Introduction of heterogeneously distributed skeletal tissues, adipose and muscle American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 9/12

R. Kramer et al. Ratio of effective doses 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 EXTERNAL EXPOSURE TO PHOTONS MAX-FAX-EGS4 / ADEV-ICRP74 0.4 30 kev 0.01 0.1 1 10 Photon Energy (MeV) AP PA ROT Figure 8: Replacement of the ADAM-EVA by the MAX-FAX exposure model The consequences of all replacements together are shown in Figure 8 for external photon radiation as a function of the incident energy between 10 kev and 10 MeV for AP-, PA-, and ROT-incidence. For the EGS4-calculated data due to the differences between the ADEV/GSF and MAX-FAX/EGS4 exposure models discussed in the previous sections, the effective dose Ratio of effective doses 1.6 1.4 1.2 1 0.8 0.6 EXTERNAL EXPOSURE TO PHOTONS MAX-FAX-MCNP4C / ADEV-ICRP74 0.4 30 kev 0.01 0.1 1 10 Photon Energy (MeV) AP PA Figure 9: Replacement of the ADAM-EVA by the MAX-FAX exposure model American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 10/12

Effective dose for tomographic and stylized models from external exposure to photons decreased, which above 30 kev incident photon energy did not exceed 10% for AP-, and ROTincidence, and 25% for PA-incidence. Below 30 kev a decrease of the effective dose by ca. 43% seems possible according to Figure 8, however the discussion on statistical fluctuations and rounding errors effects in the previous sections has shown that the data in this range of energies should be used with caution. On the other hand it has to remembered that below 30 kev the values of the effective dose are usually small compared, lets say to the reading of an air kerma instrument. Moreover, in practical situations of radiation protection rotational or semi-rotational incidence is more likely than AP-, or PA-incidence, and energy distributions of radiation fields are mostly in a range above 30 kev, which leads to the final conclusion that in pracical situations for external exposures to photons the reduction of the effective dose due to the introduction of voxel-based models is ca. 10%. Figure 9 shows MAX-FAX/ADEV effective dose ratios calculated with the MCNP4C Monte Carlo code for AP- and PA-incidence. For photon energies above 30 kev the data confirm the results of the EGS4 calculations presented in Figure 8. 4 CONCLUSIONS The purpose of this paper was to investigate for external irradiation with photons the dosimetric consequences for the effective dose, when the MIRD5-type exposure models ADAM- EVA are replaced by voxel-based exposure models MAX-FAX. The analysis was done separately for the replacement of the Monte Carlo code, of the tissue composition, and of the anatomy. The data have been presented as ratios between effective doses as a function of the photon energy, and of the direction of incidence. For incident photon energies between 30 kev and 10 MeV the results have shown that replacing the ICRP74 Monte Carlo code by the EGS4 Monte Carlo code caused differences of ca.1% for the effective dose which is significantly smaller than the range of the combined CVs, and replacing the ICRP74 Monte Carlo code by the MCNP4 Monte Carlo code led to a decrease of the effective dose of about 5% on the avergage for AP- and PA-incidence. Introduction of ICRU44-based tissue compositions caused an increase of the effective dose by up to 9%, while introducing real human anatomy led to a decrease by up to 30% of the effective dose. Finally the combined effect from all replacements suggests that the effective dose for the voxel-based model MAX-FAX would decrease by ca. 10% for incident energies between 30 kev and 10 MeV, and for most directions of incidence compared to the ADAM-EVA effective dose. 5 ACKNOWLEDGEMENT The authors would like to thank the Conselho Nacional de Desenvolvimento Científico e Tecnológico - CNPq and the Fundação de Amparo à Ciência do Estado de Pernambuco - FACEPE for the financial support. 6 REFERENCES 1. ICRP 60, 1990 Recommendations of the International Commission on Radiological Protection, ICRP Publication 60, International Commission On Radiological Protection, Pergamon Press, Oxford, (1991). American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 11/12

R. Kramer et al. 2. KRAMER R, ZANKL M, WILLIAMS G and DREXLER G, The Calculation of Dose from External Photon Exposures Using Reference Human Phantoms and Monte Carlo Methods. Part I: The Male (Adam) and Female (Eva) Adult Mathematical Phantoms. GSF- Report S-885. Institut für Strahlenschutz, GSF-Forschungszentrum für Umwelt und Gesundheit, Neuherberg-Muenchen, (1982). 3. ICRP 74, Conversion Coefficients for use in Radiological Protection against External Radiation, ICRP Publication 74. International Commission on Radiological Protection, Pergamon Press, Oxford, (1996). 4. KRAMER R, VIEIRA J W, KHOURY H J, LIMA F R A and FUELLE D, All About MAX: a Male Adult voxel Phantom for Monte Carlo Calculations in Radiation Protection Dosimetry, Phys. Med. Biol., 48, no. 10, 1239-1262, (2003). 5. KRAMER R., VIEIRA J. W., KHOURY H. J., LIMA F. R. A., LOUREIRO E. C. M., LIMA V. J. M. and HOFF G., All about FAX: a Female Adult voxel Phantom for Monte Carlo Calculation in Radiation Protection Dosimetry, Phys. Med. Biol. 49, 5203-5216, (2004). 6. ICRP 89, Basic Anatomical and Physiological Data for Use in Radiological Protection: Reference Values. ICRP Publication 89, International Commission on Radiological Protection, Pergamon Press, Oxford, (2003). 7. ICRP 70, Basic Anatomical and Physiological Data for Use in Radiological Protection: The Skeleton. ICRP Publication 70. International Commission on Radiological Protection, Pergamon Press, Oxford, (1995). 8. ICRP 23, Report of the Task Group on Reference Man, ICRP publication 23, International Commission on Radiological Protection, Pergamon Press, Oxford, (1975). 9. NELSON W R, HIRAYAMA H and ROGERS D W O, The EGS4 Code System. SLAC- 265 Stanford Linear Accelerator Center, Stanford University, Stanford, California, (1985). 10. BRIESMEISTER J F et al, MCNP: A General Monte Carlo N-Particle Transport Code, Version 4C. Edited by J F BRIESMEISTER, Report No. LA-13709-M, Los Alamos Scientific Laboratory, Los Alamos, NM, (2000). 11. ICRU 44, Tissue Substitutes in Radiation Dosimetry and Measurement. ICRU Report 44. International Commission On Radiation Units And Measurements, Bethesda, MD, (1989). 12. ZANKL M, DREXLER G, PETOUSSI-HENSS N and SAITO K, The Calculation of Dose from External Photon Exposures Using Reference Human Phantoms and Monte Carlo Methods. Part VII: Organ Doses Due to Parallel and Environmental Exposure Geometries. GSF-Report 8/97. Institut für Strahlenschutz, GSF-Forschungszentrum für Umwelt und Gesundheit, München-Neuherberg, (1997). 13. KRAMER R, VIEIRA J W, KHOURY H J and LIMA F R A, MAX meets ADAM: a Dosimetric Comparison Between a Voxel-Based and a Mathematical Model for External Exposures to Photons, Phys. Med. Biol., 49, 887-910, (2004). American Nuclear Society Topical Meeting in Monte Carlo, Chattanooga, TN, 2005 12/12