Clarity Controls Clarity Controls Agilent 5890 Agilent 5890

Similar documents
Agilent 68xx Agilent 68xx

ERC REFRACTOMAX 520. Clarity Control Module. Code/Rev.: M190/70C Date: 8/23/2018

Clarity Hardware. Duratec DDT 3200 USB. Code/Rev.: M064/24C 27 September 2006

HT3X00A. Clarity Control Module. Code/Rev.: M153/50E Date: 11/13/2018. Fax: Petrzilkova 2583/ Prague 5

MULTICOM. Clarity Hardware. Code/Rev.: M110/80A Date: 8/15/2018. Fax: Petrzilkova 2583/ Prague 5

Contents 1 Opt-USB 2 Requirements 3 Installation 4 Troubleshooting 5 Tables and specifications

HITACHI LACHROM ELITE

COLIBRICK A/D CONVERTER

U-PAD2 A/D CONVERTER

INT7 A/D CONVERTER. Clarity Hardware. Code/Rev.: M058/80A Date: 6/6/2018

U-PAD A/D CONVERTER. Clarity Hardware. Code/Rev.: M059/80A Date: 6/6/2018

LC UNI - SSI PUMPS. Clarity Control Module. Code/Rev.: M038/40D Date:

SHIMADZU LC-10/20 SYSTEM

AGILENT 1100/1200. Clarity Control Module. Code/Rev.: M060/70D Date: 10/5/2017

USB ph MONITOR. DataApex Clarity Control. Doc. #: DI Rev. A Praha, March 2013

Fluke Metrology Software

SICO-300 COLUMN OVEN

Clarity. Clarity Demo. Code/Rev.: M003/60A Date: Fax: Petrzilkova 2583/ Prague 5

Chemical Analysis Group Gas Chromatograph Common Cabling \ Pin-outs Document A15707

DESCRIPTION. DataApex Clarity 32bit multi instrument chromatography station for Windows

D8000 SERIES QUICK START GUIDE

Firmware Reprogramming Guide

Procedure to set up an HPIB 82350B card on an M57. M58 or C20x PC. Table 1: Parts required. Part Number Description Qty

PDA EXTENSION. Clarity Extension. Code/Rev.: M054/80A Date: 6/8/2018. Fax: Petrzilkova 2583/ Prague 5

Modem Configuration Procedure

Version 2.4

SERVICE INSTRUCTION. Updating the firmware and software on the RCS-2

Data Acquisition Software and Hardware. Demonstration Guide. For: NetDAQ Logger, Hydra Logger, and Trend Link for Fluke V3.1

Windows XP Software Installation Instructions GCC Elite Series Printers

Data Acquisition. Software and Hardware. Demonstration Guide. For: NetDAQ Logger for Windows Hydra Logger for Windows Trend Link for Fluke

OPERATING MANUAL AND TECHNICAL REFERENCE

MAGUIRE G2-ES Configuration Instructions for Ethernet to Serial Converter Model: Moxa NPort 5110 Serial Device Server

SWC1090 configuration software for G.M. International Isolators series D1000 and E1000. Installation and use manual

ProjectorNetTM Adapter Quick Start Guide

BASCOM51. Quick Start Guide

User s Guide QL-720NW

3.1 I-7560 Pin Assignment and Specifications: Introduction

Serial DHX Driver Help Serial DF1 Protocol Driver for Allen-Bradley Networks

ALDL Bluetooth Adapter

GEM80 & ewon Setup Quick Guide

PCI Express 4-Port Industrial Serial I/O Cards

2001 by NEC America. All Rights Reserved. Printed in U.S.A.

Q-Stress 4.6 Software Installation & Upgrade

CLARITY DEMO. Clarity Demo Software. Code/Rev.: M003/70E Date:

STAR Comm Modem Kit for the Micro/PX-2000: Setup Instructions

Getting started with your DGH module:

DIRECT INTERNET 3. Install Guide for the Mac OS Operating System

TOSVERT VF-AS1/PS1. Trace Tool PCT001Z-E. Instruction Manual

Data Acquisition with 3400/3600 GC Control

Data Acquisition Software and Hardware Demonstration Guide

SERIAL COMMUNICATION for Delta VFD drives

CommLink IV Technical Guide

Instrument Network (INET) or Local Area Network (LAN) Communications Interface Board Installation Guide

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

$ERXW<RXU9,%5$Œ&DUG. Introduction

Serial Connection of HC900 Hybrid Controller to 900CS Control Station

ALERT CONFIGURATION GUIDE SIA DRIVER

G2-ES Configuration Instructions

GC-10 Wireless Control Box. User Guide

USB485. USB to RS485 Converter Card. User Manual for connecting with Windows Vista Version 1.01

Clarity vs CSW32 Clarity vs CSW32

MU Beta. Real-Time In-Circuit Emulator for the Microchip PIC microcontrollers. User's Manual

MW100 CAN Bus Module Configuration Tool (MX118-CAN-M30/S1) User s Manual

RKAT Audit Trail Module RK-LINK TM Software For the Radio Key 600 Series

TRP-C08X. USB To 4 RS232/422/485 Converter. User s Manual

M8240BA Shimadzu LC Control Driver 1.51 for OpenLAB CDS

Older Compaq UPS Family - Identifying Serial Communication Cables

Using SIMDIS Expert 9 (Separation Systems) with Clarity

Programming in the MAXQ environment

Installation Guide. Website: Advanced Card Systems Ltd. Website:

MultiPort USB User Manual

MCA8000D OPTION PA INFORMATION AND INSTRUCTIONS FOR USE I. Option PA Information

AutoDome Modular Camera System

XC866 Getting Started on EasyKit & Toolkits

ACCESS CONTROL SOFTWARE V3.1 REFERENCE MANUAL

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

Upchurch Scientific Nano Flow Sensor User s Guide

Hardware Manual. PCMCIA 1 Port RS EDITION APRIL 1999

User Manual. Printed: 11/6/2013 Filename: NATUM1 - National Instruments I/O Device for V+ User Manual, V1.1 Copyright 2003, SimPhonics Incorporated

IntesisBox Modbus Server Siemens Synova FC330A

ADC REVISION HISTORY INTRODUCTION INSTRUCTIONS CABLE REQUIREMENTS

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

Longshine Technologie Europe GmbH

- MANUAL FOR PC CONNECTION -

Remote Manager Manual

Waters Empower Software A1100 System Configuration Instructions for Ethernet Control

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

SIGFOX-CCT (Configuration and Communication Tool) User Manual

UPDATING THE SYSTEM MANAGER SD Updating the System Manager with Prism 2

Fox Thermal Instruments, Inc.

TRANSCEIVER DATA PROGRAMMER TDP-136 INSTALLATION & OPERATING INSTRUCTIONS. Document No. 00RE277 Rev. C FEB Technisonic Industries Limited

8051 Intermidiate Development Board. Product Manual. Contents. 1) Overview 2) Features 3) Using the board 4) Troubleshooting and getting help

User Manual. LPC-StickView V1.1. for LPC-Stick. Contents

Thermal Transient Test

USB485 USB to RS485 Converter Card

Use a hardwired Ethernet to RS232 Converter [Moxa N Port Express ]

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Software Installation Guide

Wireless M-Bus Suite for Panasonic Evaluation Boards. Quick Start Guide

TOSVERT VF-AS1/PS1. Trace Tool PCT001Z-E Instruction Manual

Transcription:

Clarity Controls Clarity Controls Agilent 5890 Agilent 5890 GC ENG Code/Rev.: M033/25D 07 January 2008 Phone: +420-251 013 400 DataApex Ltd. 2008 Fax: +420-251 013 401 Podohradská 1 clarity@dataapex.com 155 00 Prague 5 www.dataapex.com The Czech Republic

Clarity, DataApex and are trademarks of DataApex Ltd. Microsoft and Windows TM are trademarks of Microsoft Corporation DataApex reserves the right to make changes to manuals without prior notice. Updated manuals can be downloaded from www.dataapex.com.

Table of Contents 1 Agilent 5890 GC Control Module...4 2 Requirements...5 3 Installation Procedure...6 3.1 GC Chromatograph setup...6 3.2 Installing the GC module in the PC:...7 3.3 Clarity configuration...8 3.3.1 Configure the GC Agilent 5890 control module:...8 3.4 Method Setup...10 3.5 Connections...12 3.6 Description of connectors:...13 4 Troubleshooting...13 4.1 Commdrv.log utility...13 3

Agilent 5890 GC Control Module 1 Agilent 5890 GC Control Module The Agilent 5890 GC driver can control Agilent (formerly HP) 5890A and 5890 Series II chromatograps. The control module does not support EPC, FPD and Analog Input Board (19261-60010). Fig. 1. Agilent (HP) 5890 with an autosampler Control Board compatibility: Control Board Status Description 19257-60015 HPIB/RS232 19257-60010 HPIB/RS232 19242-60010 INET 19242-60015 INET 19242-60030 RS232 Newer type; working; both analog outputs supported. Can be supplied by DataApex as a part of the IHP58 kit. Tested in DataApex. Older type; working; only one analog output is supported commonly used with integrators, cannot be used commonly used with integrators, buffered communication, cannot be used RS232 board only, uses different communication protocol, cannot be used 4

2 Requirements Caution! Requirements Clarity Installation CD ROM with GC Control module (p/n A23). Free serial port in the PC (fast - 16550 UART). Modern computers usually have only 1 (if any) serial (COM) port installed. To use more devices requiring the port, the MultiCOM adapter (p/n MC01) is available. Serial cross DB9F-DB25M cable (p/n SK03). Cables are not part of Clarity Control Module. It is strongly recommended to order required cables together with the Control Module. HPIB/RS232 Interface card set for HP 5890 (p/n IHP58). Check the Control Board compatibility table above. The Interface card set includes the HP-IB/RS232 Ribbon Cable (p/n KB58-1, Agilent order No. 19257-60500), Back Panel (p/n KB58-2, Agilent order No. 19257-60020) and the Interface card (p/n KB58-3, Agilent order No. 19257-60015). When using the HPIB card from Agilent, the Ribbon Cable and Back pannel have to be ordered separately. 5

3 Installation Procedure Installation Procedure 3.1 GC Chromatograph setup Installing the interface card in the GC unit Not necessary if the board is already installed Unscrew and remove the right-hand panel of the chromatograph Remove the original INET card Set up the interface card - all DIPs to the right (to the side of the card) Insert the interface card On newer interface cards provided by DataApex company is the INET loop connector disabled and the connection is provided by wires attached to the back side of the card. If you want to use the loop cable for any reason, cut off the wires on the back side of the card (see Fig. 2 on page 6). Install the serial connector at the back of the GC (Models of the first series 5890A do not have a hole for this connector then it is possible to put the Cannon 25 connectors on the bottom of the GC) Fig. 2. Installation of the INET card 6

Caution! Installation Procedure Switch the GC over to the Global Mode - press successively:. 3 - ENTER ON - CLEAR. Digital data acquisition works only in GLOBAL mode. Test the INET loop function. 7 - ENTER and after the test CLEAR. GC would not send Ready signal in local mode. Analog acquisition alternative When using A/D converter the GC has to be in Local Mode - press successively:. 3 - ENTER - OFF - CLEAR. 3.2 Installing the GC module in the PC: Select and if necessary install a fast serial port in the PC. Caution! In the following procedure the setup of HP 5890 with digital acquisition (without A/D converters) will be described. Install Clarity station; in the HW Setup dialog check the Other option during installation. Connect the GC to the PC by serial cable; turn the power GC on. 7

Installation Procedure 3.3 Clarity configuration 3.3.1 Configure the GC Agilent 5890 control module: Invoke the System Configuration dialog acessible from the Clarity window using the System Configuration command. Press the Add button (see Fig. 5) to invoke the Available Control Modules dialog. Fig. 3. Available Control Modules Select the Agilent 5890 GC Driver and press the Add button. The HP5890 GC Config dialog will appear. Fig. 4. HP5890 Config In the HP5890 GC Config dialog set COM port, Baud Rate: 19200 Other baud rates can be set according to the DIP switches in the GC unit. 8

Installation Procedure Select the Version. Check the Digital Acquisition checkbox and fill in the names of your detectors. Use the Autodetect button to read in instrument configuration and check the communication. Press the OK button. The Agilent 5890 GC Driver item will appear in the Setup Control Modules list in the left part of System Configuration dialog. Switch to the desired Instrument X tab in the right part of the System Configuration dialog. The Instrument Type must be set to GC. Fig. 5. System Configuration Drag and drop the HP 5890 GC Driver from the Setup Control Modules in the left to the instrument on the right or use the --> button. Set only one detector if you do not wish to acquire both signals simultaneously. 9

Installation Procedure 3.4 Method Setup New tab GC Control appears in the Method Setup dialog, enabling the setting of GC control method. Use the From GC button to download current method parameters from Agilent 5890 (and save it under suitable name). You can use this procedure to copy the parameters of your methods already stored in the GC memory to Clarity. Use the To GC button to upload the Clarity method GC parameters to Agilent 5890. Use the GC Status button to see the current GC configuration (inlets, detectors etc. in DEMO mode it enables selecting them) Use the upper tabs in the Method Setup - GC Control dialog to set or modify the GC control parameters. Fig. 6. Method Setup Oven/Zones 10

Installation Procedure On the Signals tab, you can assign the Detector (or other signal) to the output Signals. In the Method Setup - Acquisition dialog, check the External Start/Stop checkbox and select the voltage range to be acquired. Signals exceeding this value will be cut. The acquisition frequency Rate is fixed to 10 Hz for Agilent 5890 with digital data acquisition 11

3.5 Connections Installation Procedure When the HP5890 is controlled by the serial line (RS232), both INET connectors must be connected, which can be done by wiring on the back side of the card or INET loop cable. Communication between AS and PC (COM port) procceds over standard serial printer cable see Fig. 6 (modem cable cannot be used). If serial communication cannot be established and all parameters of communication are correctly set (speed, parity, etc.), then we recommend to remeasure the cable according to the following scheme (especially pin connection 2 and 3). Fig. 7. Serial cross cable DB9F DB25M Cables are not part of Clarity Control Module. It is strongly recommended to order required cables (p/n SK) together with the Control Module. 12

Troubleshooting 3.6 Description of connectors: 4 Troubleshooting Signal 1 (2) 12-pin HP connector with output of both analog amplifiers (connected to detector). It is possible to plug in both orientations with same function. Not necessary when using the digital acquisition. Remote 12-pin HP connector dedicated to send start signal to Clarity It is necessary to plug it in proper position according to mark on cable connector Not necessary when using digital acquisition INET INET loop cable. In case of newer INET cards provided by DataApex company, no loop cable is needed. The cable connection is replaced by wiring on the back side of the card. RS232 25-pin female Cannon connector for direct control and digital acquisition Configuration for two independent detectors Independent (isothermal) dataacquisition on two independent detectors can be used only with analog data acquisition (using A/D convertor). It cannot be used with digital data acquisition. 4.1 Commdrv.log utility It is possible to record the communication between Clarity and the device. To activate the recording and specify a file for storing the communication set the COMx key(s) with following parameters in the COMMDRV.INI file located in the Clarity installation folder: 13

Troubleshooting [COM1] Echo=On textmode=on filename=commdrv1.log reset=off The file can be edited by any text editor (Notepad). Separate entries can be specified for each Com port. Echo Off (default) - no communication will be recorded. Filename The file where the communication should be stored. If the path is not specified the file will be stored in the same folder like the COMMDRV.INI file. Not received or unrecognized replies will be recorded as Timeout on Com line The created log file can be viewed in any text editor. The record is very helpful for trobleshooting the communication between Clarity and the device. Reset On - will erase the log each time the station is restarted (otherwise the log can increase substantially after some time) 14