Høgskolen i Telemark Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics.

Similar documents
Wireless DAQ using ZigBee

NI mydaq HANS-PETTER HALVORSEN, Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics

Virtual Instruments with LabVIEW

Data Acquisition HANS-PETTER HALVORSEN,

Datalogging in LabVIEW

NI Vision System HANS- PETTER HALVORSEN,

DAQ in MATLAB HANS-PETTER HALVORSEN,

Wireless DAQ System. In this project you are going to create a Wireless DAQ System, see Figure 1-1. Figure 1-1: Wireless DAQ system

Solutions. Discretization HANS-PETTER HALVORSEN,

NI USB-TC01 Thermocouple Measurement Device

Faculty of Technology, Department of Electrical Engineering, Information Technology and Cybernetics. SCADA System

Control and Simulation in. LabVIEW

Laboratory System. 1 Introduction

Weather System. In this project you are going to create a Weather System, see Figure 1-1. Figure 1-1: Weather system

BR411AP n Wireless Access Point and Bridge

State Estimation with Observers

Quick Setup Guide. for Standalone Omada Access Points. EAP110 / EAP115 / EAP225 / EAP245 / EAP320 / EAP330 / EAP115-Wall

PePWave Mesh Connector User Manual

Click on Close button to close Network Connection Details. You are back to the Local Area Connection Status window.

Access Your 34972A Wirelessly with a TRENDnet Travel Router

QUICK START GUIDE. WK-2x Access Point. WK-2, WK-2-B, WK-2-C / ac Dual Band Access Version 1.1

WAP3205 v2. User s Guide. Quick Start Guide. Wireless N300 Access Point. Default Login Details. Version 1.00 Edition 2, 12/2012

WRE6606. User s Guide. Quick Start Guide. Dual-Band Wireless AC1300 Access Point. Default Login Details. Version 1.00 (ABDU.0) Edition 1, 10/2016

Radiolabs Bridge in a Box Setup

WF-2402 Quick Installation Guide

Wireless USB Port Multi-Functional Printer Server. Model # AMPS240W. User s Manual. Ver. 1A

Exercise 5: Basic LabVIEW Programming

Add a Wireless Network to an Existing Wired Network using a Wireless Access Point (WAP)

Quick Start Guide for Standalone EAP

Quick Installation Guide

User Manual of 5.8G Outdoor CPE

Hardware overview. Package contents V-M200, documentation, three antennas, and power supply.

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

Networking the printer

How to setup WL-WN575A2/WL-WN575A3 Repeater Mode through Ethernet Cable

WRE6505 v2. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1, 10/2016

Quick Start Guide. NP290W Turbo Wireless HomePlug

WiFi-Repeater User Manual. Quick Installation Guide(Q.I.G.) REV.1.2

A Division of Cisco Systems, Inc. GHz 2, g. Wireless-G. User Guide. Access Point WIRELESS WAP54G (EU/LA/UK) Model No.

Quick Installation Guide DAP N300 Wi-Fi Range Extender

AIR HANDLING UNIT CONNCECTION VIA TL-WR802N (AHU, TL-WR802N, smartphone) QUICK LAUNCH GUIDE P0117_AZ_0001

Premiertek AP Mbps Wireless-N Broadband Router Quick Installation Guide

Quick Installation Guide TEW-640MB 1.01

Quick Installation Guide TEW-687GA 1.01

WAP6405. User s Guide. Quick Start Guide. 5GHz AC1750 Gigabit Wireless Bridge. Default Login Details. Version 1.00 Edition 1, 06/2016

802.11g Wireless Access Point

Windows Vista Installation Guide

Quick Installation Guide DIR-300NRU. Wireless Router with Built-in 4-port Switch

Rapidlogger Systems. EnGenius ENS202EXT Access Point

Quick Installation Guide of Acer WLAN 11b Broadband Router

Table of Contents. Page ii

54Mbps Pocket Wireless Access Point (WL-330g)

Please note, instructions in this guide are based on a PC running Windows 7. Please adapt the actions to suit your operating system.

Neighborhood HiSpeed Quick Start Guide

Lab - Configure a NIC to Use DHCP in Windows

802.11ac Wireless Access Point Model WAC104

Application Example (Standalone EAP)

Quick Installation Guide DSL-2640U/NRU. ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Quick Installation Guide DSL-2650U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

HP Deskjet 6800 series

123 Manual, LP-1522 Broadband Wireless AP/Router, Point to point/ Point to Multipoint plus Access point installation mode.

Quick Installation Guide DSL-2650U. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

2) INSERT THE SETUP CD

VDSL Router 4 Port Wi-Fi Dual Band (NT3BB-4PVWN-147) Quick Installation Guide

A Division of Cisco Systems, Inc. GHz 2, g. Wireless-G. User Guide. PCI Adapter WIRELESS. with SpeedBooster WMP54GS (EU/UK/LA) Model No.

NETWORK USER S GUIDE. Multi-Protocol On-board Ethernet Multi-function Print Server and Wireless Ethernet Multi-function Print Server

LabVIEW Tutorials. T.1 Temperature Measurement and Cold Junction Compensation (CJC) LUMS School of Science and Engineering

Configuring the network clients

User Manual of NC-AC44APP/NC-AC21AP

Customer Installation Guide NBG-4615 v2 ZyXEL Wireless Router

Congratulations on purchasing Hawking s HWPS12UG 1-Port Parallel + 2 USB Ports Wireless G Print Server. The Hawking HWPS12UG is a powerful and

Lab - Connect to a Router for the First Time

Network Camera Firmware Upgrade Quick Guide

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

It is a Plug & Play Solution It is a bundle, containing an HP5100S and an NHP5010

User Guide. 450Mbps/300Mbps Wireless N Access Point TL-WA901ND/TL-WA801ND REV

Data Acquisition in LabVIEW

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

Wireless-G VPN Router with RangeBooster. Quick Install Guide

DI GHz Wireless Router

Installing driver over the network

NETGEAR Trek N300 Travel Router and Range Extender

Dongle-sized Wireless Print Server. Quick Installation Guide V1.0

Quick Installation Guide

AirServer Connect User Guide

Zavio P5111/ P5116/ P5210 Quick Installation Guide

H560N. Quick Start Guide

Shaw Business Hitron Modem (CGNM-2250) Configuration User Guide

Wireless PC Network Settings

Package Contents. Preface. Front Panel. Rear Panel

Network Name displays the name of the wireless network your machine is connected to (this says network name when not connected to a network).

DWL-900AP+ D-Link AirPlus Wireless Access Point

Quick Installation Guide TV-IP602WN 1.01

Installing the Driver, Client Utility, and Client Adapter

DWL-2100AP. Check Your Package Contents. This product can be set up using., Internet Explorer 6 or Netscape Navigator

MatchPort E Embedded Device Server Demonstration Kit Quick Start Guide

Overview. Introduction. Contents. Linksys Wireless-N Range Extender. Front

Zavio F3100 / F3105 Quick Installation Guide

DSL-G624T. Wireless ADSL Router. If any of the above items is missing, please contact your reseller. This product can be set up using any

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.

Transcription:

Høgskolen i Telemark Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics Wi- Fi DAQ Hardware Setup Cuong Nguyen, Hans- Petter Halvorsen, 2013.08.07 Faculty of Technology, Postboks 203, Kjølnes ring 56, N-3901 Porsgrunn, Norway. Tel: +47 35 57 50 00 Fax: +47 35 57 54 01

Table of Contents 1 Introduction... 3 1.1 Necessary Equipment... 4 2 Technical Implementation... 5 2.1 Step1: Physical Connection... 5 2.2 Step 2: NI WAP- 3711 Configuration... 6 2.3 Step 3: NI WLS- 9163 Configuration... 9 2.4 Step 4: Computer Configuration... 13 2.5 Step 5: Temperature Presentation... 16 3 Summary... 19 2

1 Introduction This tutorial will go through how to transfer data acquired from a sensor to the computer wirelessly by using a Wi- Fi DAQ system. The data transmission relies on National Instruments technology, where NI WAP- 3711 will broadcast wireless internet from TUCs LAN. This documentation is created based on experiment by using the following equipment: Hardware Ø Temperature sensor PT- 100 Ø Transducer board Ø Wi- Fi equipment - NI WAP- 3711 (802.11g/b WAP/Bridge/Client) - NI WLS- 9163 (802.11g/b C Series Carrier) - NI 9234 (DAQ) Software Ø Windows OS Ø LabVIEW Ø NI- DAQmx (MAX) The data transferring procedure through Wi- Fi (Infrastructure) technology involves mainly five different steps; Step 1: Step 2: Step 3: Step 4: Step 5: Physical devices, setup and connection. Devices: NI- WLS- 9163, NI9234 (DAQ) and connection board shall be physically connected to each other. NI WAP- 3711 configuration. Set up and configure NI WAP- 3711 to manage the wireless data communication between the computer and NI WLS- 9163 device. NI WLS- 9163 configuration. Set up and configure NI WLS- 9163 to transmit temperature values to NI WAP- 3711. Configure your computer to get access to NI WAP- 3711. Present the temperature value on the computer. Create a LabVIEW application to continuously retrieve and present the value on your computer. The acquired values are originally in Voltage format which needs to be converted into corresponding temperature. 3

4 Introduction 1.1 Necessary Equipment Software NI WAP- 3711 Hardware NI WLS- 9163 Temperature sensor: PT- 100 NI WLS- 9234 Transducer board

2 Technical Implementation This section will explain the data acquiring process in details, which covers all the involving five steps stated above. By following the instructions, as the result temperature values obtained by the temperature sensor (PT- 100) will be presented on the computer screen wirelessly. Wi- Fi (infrastructure) is the technology behind the wireless data transferring procedure. Here we use NI WAP- 3711 to broad cast wireless network, which is based on TUCs LAN. The wireless network (Eduroam) offered by TUC is heavily encrypted and has a lot of restrictions, by creating our own WAP data transmitted will be more flexible and give us more possibilities. 2.1 Step1: Physical Connection PT- 100 is a temperature sensor based on resistance (Ω) which various in corresponding to the changing in temperature. This element cannot be connected directly to the NI 9234 (DAQ) module because it requires input as Voltage. Due to this reason the two elements can only have communications with each other through the transducer board. Additionally, both of the devices NI 9234 (DAQ) and NI WLS- 9163 are needed to be attached to each other as one single physical component. Mount NI 9234 (DAQ) and NI WLS- 9163 together as one physical unit. Ø Just simply slide the two modules together, make sure both of the modules are firmly connected with each other as shown in the figure 2-1. Figure 2-1: NI 9234 and NI WLS- 9163 attachment PT- 100 sensor and AC to DC switching power supply are already connected to the transducer board. No further actions needed here. To read the temperature value from PT- 100, the NI 9234 (DAQ) needs to be connected to the transducer board. Study figure 2-2 for details. Ø Same colors are connected to each other. 5

6 Technical Implementation Ø Attached the coupling wire to any of the pins on the NI 9234 (DAQ). AI0 pin used in this experiment. Figure 2-2: NI 9234 and transducer board connection. Once the connection is established. Ø Simply plug the power supply to the wall outlet. The Transducer board will operate by 24 Voltage DC. 2.2 Step 2: NI WAP- 3711 Configuration The NI WAP- 3711 device can be fully configures by using any web browsers. In able for doing any changes on this device, users have to have password access. Once the users manage to log in, then they have fully access to the device without any restrictions. The users are able to set new SSID name, new IP address, change security settings, change passwords and ect. In this particular case all we have to do is just simply establish connection between NI WAP- 3711 and TUCs LAN with an Ethernet cable in between. By default NI WAP- 3711 is correctly configured for this purpose. Ø Power up NI WAP- 3711 and push the reset button for at least five seconds. To make sure the device is configured as default. Ø NI WAP should broadcast internet. Continue from step 3. Logging on to NI WAP- 3711 Note!! This step is not necessary in this case, if so continue from step 3. However, if you have to configure the device just continue to follow instructions.

7 Technical Implementation Ø Connect your computer to NI WAP- 3711 by using Ethernet cable (straight- through or cross- over cable) Ø In able for different devices to have successful communications to each other, the requirement is that they all have to be in the same subclass (Subnet mask). Therefore we have to change the IP address on your computer so it is in the same subclass as NI WAP- 3711. Start menu Control Panel View network status and tasks. Figure 2-3: Local Area Connection Ø Local Area Connection Properties Internet Protocol Version 4(TCP/IPv4) Properties Ø Select: Use the following IP address in the pop up window and type in the numbers exactly as illustrated in the figure 2-4 OK. Note! the IP address: 102.168.127.X (where X can be any integer from 1 252 and 254) Figure 2-4: Assign address to Local Area Connection.

8 Technical Implementation Ø Open a web browser (Mozilla Firefox or Internet Explorer) from the address bar type: http://192.168.127.253 Enter. Ø Fill in User Name and Password. User Name: Admin Password: root Figure 2-5: Logging into NI WAP- 3711. Now you should be logged on to NI WAP- 3711 and have full access to the device. Configure NI WAP- 3711 Ø General Operational Mode Select AP/Bridge Save Ø TCP/IP Addressing Method of obtaining an IP address: Set Manually IP address: 192.168.127.253 Subnet mask: 255.255.255.0 Default gateway: 192.168.127.1 Host name: adv ap Make sure the numbers are identical as shown in figure 2-6 Save & Restart. Figure 2-6: TCP/IP Addressing setting.

9 Technical Implementation Ø TCP/IP DHCP Server Functionality: Enabled Default gateway: 192.168.127.1 Subnet mask: 255.255.255.0 Primay DNS server: 192.168.127.1 Make sure your setting is identical to the figure 2-7. Figure 2-7: DHCP Server setting. Ø IEEE 802.11 Communication Change the SSID name from NI to WAP (SSID can be given by any name) Network name (SSID): WAP Channel number: 3 (any integer 1-13 ) Note!! Channels 1, 4 and 11 are very actively used. To avoid interference or other unexpected problems try to avoid these channels. Ø Save & Restart NI WAP- 3711 is now fully configured. 2.3 Step 3: NI WLS- 9163 Configuration NI WLS- 9163 is used to transmit the temperature data to NI WAP- 3711 and can be configured by using Measurement & Automation (MAX). MAX is a software which allows users to fully access and configure settings of NI WLS- 9163. Download and install Measurement & Automation (MAX). Ø Open the link below and follow instructions given in the website to download and install NI- DAQmx 9.6 (MAX). Note!! Choose latest version if available. http://joule.ni.com/nidu/cds/view/p/id/3423/lang/no Set Local Area Connection on your computer to obtain an IP address automatically Ø Start menu Control Panel View network status and tasks.

10 Technical Implementation Figure 2-8: Local Area Connection. Ø Local Area Connection Properties Internet Protocol Version 4(TCP/IPv4) Properties Ø Select Obtain an IP address automatically in the pop up window OK. Ø Connect Ethernet cable from NI WLS- 9163 to your computer. (Physical connection between your computer and NI WLS- 9163 is established) Use MAX to detect NI WLS- 9163 device and do the configuration Ø Start Measurement and Automation (MAX) application by double click on the NI MAX icon on the desktop. Ø Click the arrow (Devices and Interfaces) to view a list of all the DAQ devices. See figure 2-9. Ø Right click on Network Devices click on Find Network NI- DAQmx devices. This will detect any current devices connected to your computer. Figure 2-9: Detecting NI WLS- 9163 by using MAX.

11 Technical Implementation Ø Tick WLS- 14215DD (or any NI- DAQmx device that is found) Add Selected Devices. Detect and configure NI WLS- 9163 Figure 2-10: Add devices to MAX. Ø Click NI WLS- 9234 WLS- 14215DD and create identical as shown on figure 2-11. Ø Obtain IP Address Through: Static IP Address: 128.39.35.240 Subnet Mask: 255.255.254.0 Gateway: 128.39.34.1 DNS Server: 128.39.198.39 (or leave empty box). Ø Note!! Country should be specified as United State. From experience attempts to set to Norway causes unsuccessful connection. Ø SSID: NI (By default NI WAP- 3711 broad cast the SSID name as NI) Ø Authentication Type: Open (By default NI WAP- 3711 is not encrypted by password, if it does: just type in the security type and password) Figure 2-11: NI WLS- 9163 configuration.

12 Technical Implementation Ø Click: Save Settings... Refresh Note!! Press Refresh button several times until you obtain Wired and Wireless is shown Up. Note!! If Wire and Wireless both are not shown as Up, just untick Radio On Save Settings Tick on the Radio On button Save Settings Refresh. Ø Remove the Ethernet cable from NI WLS- 9163 Click: Refresh Note!! Wired down and Wireless Up (wireless communication between NI WLS- 9163 and NI WAP is successfully established) Figure 2-12: NI WLS- 9163 wireless connection. Click: Self- Test (To validate a successful connection). Figure 2-13: Successful communication confirmation. Test to retrieve value wirelessly from NI WLS- 9163 Ø Click: Test Panels Coupling: DC Acquisition Mode: Continuous

13 Technical Implementation Figure 2-14: Result shown in Test Panel. All the obtaining values are presenting only in Voltage DC (1-5V). You are now successfully retrieving data from NI WLS- 9163 and NI WAP- 3711 to your computer completely wireless. 2.4 Step 4: Computer Configuration At this moment your NI WAP- 3711 should be able broadcast internet. Now we shall connect the computer to get access to NI WAP- 3711. If the connection between your computer and this wireless network is successfully, it should have internet access. Use a web browser to validate a successful connection. As mentioned from previous, wireless network (Eduroam) provided by TUCs is heavily encrypted and causes easily complications. As I discovered that The LAN server at TUC will only allow a certain specific group of IP- addresses, in another word LAN server controls which IP- addresses shall have permission to the provided service. Logically as it is, every computer in the IT- labs in TUC carries a valid IP- number. We need to find out two valid IP- addresses that are accepted by the LAN server of TUC. Once we know the allowable IP- numbers then we will assign our computer with one of the IP- addresses, while the other IP- address will be given to NI WLS- 9163 device. It is obvious that every device has to have a

14 Technical Implementation valid IP- address that is accepted by the LAN server in able to utilize the resources broadcasting by the Wireless Access Point. Note! The following IP- addresses are reserved (available) for the laboratory context. IP- address: 128.39.35.239 128.39.35.240 128.39.35.241 128.39.35.226 Subnet mask: 255.255.254.0 Gateway: 128.39.34.1 DNS: 128.39.198.39 Assign your computer with one of the IP- addresses above Ø From your computer Click: Start menu Control Panel View network status and tasks. Figure 2-15: Wireless Network Connection. Ø Wireless Network Connection Properties Internet Protocol Version 4(TCP/IPv4) Properties. Ø Select Use the following IP address in the pop up window Ø Type in the IP- addresses (parameters) above OK, an example is shown in figure 2-16. IP address: 128.39.35.239 Subnet mask: 255.255.254.0 Defalut gateway: 128.39.34.1 Preferred DNS server: 128.39.198.39

15 Technical Implementation Figure 2-16: Assign address to the laptop. Establish Wireless Network connection from your computer to WAP (in this case NI, which is the SSID name broadcasted by NI WAP- 3711). Follow figure 2-17 to manage the connection. Figure 2-17: Wireless network - Laptop connection.

16 Technical Implementation Now your computer should be connected to NI WAP- 3711. To validate the successful connection, use a web browser and surf to some home pages. Now your computer has access to internet from your own Wireless Access Point in TUC area, and not dependent on Eduroam. 2.5 Step 5: Temperature Presentation We will create a LabVIEW application to display the obtaining values in Voltage and then convert these values into corresponding temperatures. Ø Start LabVIEW and create a New VI. Name this VI (application) and save. Ø In the block diagram: right click to find DAQ Assistant. Follow instructions from figure 2-18. Figure 2-18: "DAQ Assistant" location.

17 Technical Implementation Configure the DAQ Assistant to obtain the Voltage values. Ø Click: Acquire Signals Analog Input Voltage ai0 (depending on which of the pin of NI 9234 were used) Finnish. Ø From pop up Window: Click Device Change to DC OK Ø Make sure your Block Diagram looks like the one illustrated in figure 2-19. The value is presenting in the Front Panel. Figure 2-19: LabVIEW application to retrieve data from DAQ. Advance: The front panel shown in the previous figure present the value captured from the temperature sensor PT- 100 in Voltage. The value needs to be converted into temperature [ ]. Try to improve the LabVIEW application that shows both in Voltage and degree Celsius as illustrated in figure 2-20. Tips: Use silver style as layout. Convert from Voltage to Temperature. Temperature [ ] = Voltage * a b (define parameters a & b) 1 [V] = 0 [ ] 5 [V] = 50 [ ]

18 Technical Implementation Figure 2-20: Raw and scaled data displayed on LabVIEW front panel. The block diagram of the improved front panel is shown in figure 2-21, where both of the parameters 12,5 are used to convert from Voltage to degree Celcius. Note!! These parameters can only be used for this specific case, where 1-5 Volt are converted to 0-50. For converting to a scale of 0-100, just simply replace both of the parameters 12,5 with 25. Figure 2-21: Voltage - Temperature scaled procedure in LabVIEW block diagram. If you have reached this far then you have manage to present the environmental temperature by LabVIEW application. The raw value was captured by PT- 100 sensor and transmitted completely wireless in form of Voltage DC, through Wi- Fi (infrastructure) technology.

3 Summary This chapter will summarize what have been done to get a successful wireless data transferring by utilizing Wi- Fi (infrastructure) technology, which is implemented on Windows 7 professional OS. The data transmission relies on National Instruments technology, where NI WAP- 3711 will broadcast internet from TUCs LAN. Five different steps are required to present the raw data into temperature degree ( ). Step 1: Setup and connect all the physical devices together. Step 2: Configure NI WAP- 3711 In this particular case all we have to do is just simply establish connection between NI WAP- 3711 and TUCs LAN with an Ethernet cable in between. By default NI WAP- 3711 is correctly configured for this purpose. Ø Power up NI WAP- 3711 and push the reset button for at least five seconds. To make sure the device is configured as default. Ø NI WAP should broadcast internet. Step 3: Configure NI WLS- 9163 NI WLS- 9163 is used to transmit the temperature value to NI WAP- 3711 and can be configured by using Measurement & Automation (MAX). MAX is a software which allows users to fully access and configure settings of NI WLS- 9163. Download and install Measurement & Automation (MAX). http://joule.ni.com/nidu/cds/view/p/id/3423/lang/no Set Local Area Connection on your computer to obtain an IP address automatically. Connect Ethernet cable from NI WLS- 9163 to your computer. (Physical connection between your computer and NI WLS- 9163 is established) Use MAX to detect NI WLS- 9163 device and do the configuration. Ø Obtain IP Address Through: Static IP Address: 128.39.35.240 Subnet Mask: 255.255.254.0 Gateway: 128.39.34.1 Ø DNS Server: 128.39.198.39 (or no input require). Ø Note!! Country should be specified as United State. From experience attempts to set to Norway causes unsuccessful connection. Ø SSID: NI (By default NI WAP- 3711 broad cast the SSID name as NI) 19

20 Summary Ø Authentication Type: Open (By default NI WAP- 3711 is not encrypted by password, if it does: just type in the security type and password) Ø Click: Save Settings... Refresh Note!! Press Refresh button several times until you obtain Wired and Wireless is shown Up. Note!! If Wire and Wireless both are not shown as Up, just untick Radio On Save Settings Tick on the Radio On button Save Settings Refresh. Ø Remove the Ethernet cable from NI WLS- 9163 Click: Refresh Note!! Wired down and Wireless Up (wireless communication between NI WLS- 9163 and NI WAP is successfully established) Click: Self- Test (To validate a successful connection). All the obtaining values are presenting only in Voltage DC (1-5V). You are now successfully retrieving data wirelessly from NI WLS- 9163 and NI WAP- 3711 to your computer completely wireless, in addition your NI WLS- 9163 is broadcasting internet from TUC LAN. Step 4: Configure computer At this moment your NI WAP- 3711 should be able to broadcast internet. Now we shall connect the computer to get access to NI WAP- 3711. If the connection between your computer and this wireless network is successfully, it should have internet access. Use a web browser to validate a successful connection. The LAN server at TUC will only allow a certain specific group of IP- addresses, in another word LAN server controls which IP- addresses shall have permission to the provided service. Logically as it is, every computer in the computer labs in TUC carries a valid IP- number. Find out two valid IP- addresses that are accepted by the LAN server of TUC. Once we know the allowable IP- numbers then we will assign our computer with one of the IP- addresses, while the other IP- address will be given to NI WLS- 9163 device. It is obvious that every device has to have a valid IP- address that is accepted by the LAN server in able to utilize the resources broadcasting by the Wireless Access Point. The following IP- addresses are reserved (available) for the laboratory context. IP- address: 128.39.35.239 128.39.35.240 128.39.35.241 128.39.35.226

21 Summary Subnet mask: 255.255.254.0 Default gateway: 128.39.34.1 Preferred DNS server: 128.39.198.39 Assign your computer with one of the IP- addresses stated above. NOTE!! Since you already assigned 128.39.35.240 to NI WLS- 9163, so you have to choose among the remaining addresses. Establish Wireless Network Connection from your computer to WAP (in this case NI, which is the SSID name broadcasted by NI WAP- 3711). Now your computer should be connected to NI WAP- 3711. To validate the successful connection, use a web browser and surf to some home pages. Now have access to internet from your own Wireless Access Point in TUC area, and not dependent on Eduroam. Step 5: Temperature presentation on screen We created a LabVIEW application to display the obtaining values in Voltage and then convert these values into corresponding temperatures. ü Start LabVIEW and create a New VI. Name this VI (application) and save. ü In the block diagram: right click to find DAQ Assistant. ü Configure the DAQ Assistant to obtain the Voltage values. ü In the block diagram convert from Voltage to Temperature. ü Focus on the layout in the front panel. Congratulations!! As the final result you have managed to transmit data completely wirelessly by Wi- Fi (infrastructure) technology and by using National Instruments equipments.

Telemark University College Faculty of Technology Kjølnes Ring 56 N- 3918 Porsgrunn, Norway www.hit.no Hans- Petter Halvorsen, M.Sc. Telemark University College Department of Electrical Engineering, Information Technology and Cybernetics E- mail: hans.p.halvorsen@hit.no Blog: http://home.hit.no/~hansha/ Room: B- 237a