General Specifications

Similar documents
General Specifications

General Specifications

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

General Specifications

General Specifications

General Specifications

FLEX Ex Spring Clamp Terminal Base

Type i2p-100 Electro-Pneumatic Transducer

Fisher i2p-100 Electro-Pneumatic Transducer

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

SCADAPack Modbus multivariable transmitter

Level-Lance Model 5400A

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Explosion Proof I/P Transducer

Series 3730 Electropneumatic Positioner Type

Series 3730 Type Electropneumatic Positioner

ABB MEASUREMENT & ANALYTICS DATA SHEET. JDF200 Field Indicator

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

SIY. Features. PC-Programmable Signal Isolator/Converter

Continuous level measurement Radar transmitters

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Level limit switch Series RF 3000 Selection list. Overview 2

technical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas

Sensor boxes SRBE Key features and product range overview

PD301 - PD306 Head Mount SMART TEMPERATURE TRANSMITTERS

FloBoss 107 IEC Interface

Dräger Polytron 8200 Stationary gas detector (CatEx)

CURRENT TO PROFIBUS PA CONVERTER

T EN TROVIS Electropneumatic Positioner

UFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design

SCADAPack Modbus multivariable transmitter

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Series 3731 Type Electropneumatic Ex d Positioner with FOUNDATION TM fieldbus communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Fisher i2p-100 Electro-Pneumatic Transducer

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

General Specifications

NELES ND7000 DIGITAL VALVE CONTROLLER

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Supplementary Components WirelessHART products

Series 3731 Type Electropneumatic Ex d Positioner with HART communication

4110 HART Level Encoder

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Temperature process values at a glance

Series 3730 Type Electropneumatic Positioner

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

FloBoss 103 Flow Manager

ROC800-Series IEC Interface

SFY Functional Safety Frequency-to-DC Transmitter with Display

YTA Series Temperature Transmitters

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR3/4 MLG Transmitter with Analog Output.

ABB ME ASURE ME NT & AN AL YT ICS D AT A SHE ET. WirelessHART components Gateway and accessories

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

Rosemount 248 Wireless Temperature Transmitter

Series 3731 TROVIS SAFE Electropneumatic Ex d Positioner

Explosion-Proof Gauge Pressure Transmitter

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

Flow Measurement SITRANS F M

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Installation & Operation Manual

Flow Measurement SITRANS F M

BLISS ANAND. BA-Series Magnetostrictive Level Transmitter

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Technical Data. General specifications. Rated operating distance s n 3 mm

DVC2000 Series FIELDVUE Digital Valve Controllers

Terminal Boxes Series 8118

Level Measurement Continuous level measurement - Ultrasonic transmitters

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

NELES INTELLIGENT VALVE CONTROLLER, SERIES NDX

3420 Fieldbus Interface Module (FIM) Contents

TRANSMISSOR DE PRESSÃO PIEZO RESISTIVO INTELIGENTE MICRO PROGRAMÁVEL SÉRIE PAS

DeltaV Bulk Power Supplies

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology

Series 3793 TROVIS SAFE 3793 Electropneumatic Positioner with HART communication

Analyze IT Analytical Instruments Two-Wire ph, ORP, plon Transmitters

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

DeltaV Bulk Power Supplies

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

CHRONOS IDP INTEllIGENT DIGITAl POSITIONER FOR CONTROl VAlVES

Series 3730 Electropneumatic Positioner Type and Type with HART communication

Smart Wireless THUM Adapter

Smart Wireless THUM Adapter

PROFIBUS-PA Positioner Type 3785

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Cable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof

Transcription:

General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process measurement values. Standard models are general purpose. STANDARD SPECIFICATIONS FUNCTIONAL SPECIFICATIONS Input: 4-20mA DC 2-wire Voltage Drop: 3.5V at 20mA LCD Display Numerical: Six 7-segment digits Alpha-numerical: Six 14-segment characters Bar graph: 20-segment Bar graph. Symbols: P, SP, T, F, %,, x10, x100, x1000 Configuration: User configurable for desired engineering units. Method: User configurable from front panel Zero & Span: Zero and span can be set between ±999999. Turn-on Time: 12 second (includes power on self-test and memory integrity check) Update Time: 1 second Isolation: Input/Output/Ground isolated to 500V DC PERFORMANCE SPECIFICATIONS Accuracy: ± 0.05% of full scale +1 digit Operating Current: 3.6mA to 28mA Ambient Temperature: -40 to +80 C (-40 to 176 F) Ambient Humidity: 0 to 100%RH at 23 C (73 F) Ambient Temperature Effect: 0.1 C per 10 C Over range: 200mA without damage Maximum error: +0.02%, -0.03% (of full scale) Conformity (Linearity): 0.03% Hysteresis error: 0.03% Repeatability: 0.03% Vibration: 3G @ 10-150Hz Shock: 50G Explosion Protection: FM, CSA, ATEX, and IEC PHYSICAL SPECIFICATIONS Enclosure Material Housing: Low copper cast aluminum alloy with Polyurethane resin baked finish - Deep sea moss green (equivalent of Munsell 0.6GY3.1/2.0) or SUS316 cast stainless steel (ASTM CF-8M) Name plate: Black anodized aluminum or 316 SST Tag: 304 SST Wired tag: 304 SST Degrees of Protection: NEMA 4X, IP67 Mounting: Nominal 2 (50mm) pipe mount or surface. (horizontal or vertical) Weight: 1.25kg (2.70 lbs)* *: Without mounting bracket Add 0.8 kg (0.35 lbs) for mounting bracket Electrical Connection: ½ NPT female or M20 female FEATURES User interface A front panel push button switch combined with four touch switches allows easy configuration of the indicator (calibration, span, zero and engineering units). Root extraction For applications where the process variable is non-linear and based on the square root, 3/2 root or 5/2 root, the MLX can be configured to display the root function of the input. Field Configurable Via the front panel user interface, the process variable parameters can be modified as desired in the field. LCD Display features The LCD display includes a bar graph for an analog indication of the process variable magnitude. The 6 digit display and 6 character display (combined with several symbols) give an instant view of all process variable parameters. A menu system allows customizing parameters such as decimal point position, engineering units, status of symbols and state of bar graph. Self-diagnostics Built-in diagnostics operate at power-up and during operation for ease of maintenance and troubleshooting. Yokogawa Corporation of America 2 Dart Road, Newnan, GA 30265 770-254-0400 GS 60A02S01-01E-A Copyright January 2014 4 th Edition

MODEL AND SUFFIX CODES Model Suffix Codes Description MLX... Loop Indicator Input signal -A... 4 to 20mA DC Mounting 1... 2... 2 inch Horizontal Pipe 2 inch Vertical Pipe (or wall mount) Housing 1... 2... Cast aluminum alloy SUS316 cast stainless steel and ASTM CF-8M Communication -1. Standard Electrical Connection Optional Codes -2. 0.. 2.. 3.. 4.. HART Communications (To be announced later) ANSI ½ - 14NPT female, two electrical connections without blind plugs ANSI ½ - 14NPT female, two electrical connections and a 316 SST blind plug ISO M20 x 1.5 female, two electrical connections without blind plugs ISO M20 x 1.5 female, two electrical connections and a 316 SST blind plug / Optional specification OPTIONAL SPECIFICATIONS (For Explosion Protected Type) FM Explosion-proof/FM Dust-Ignition-Proof Approval Conforms to: FM3600, FM3615, UL 1203 Explosionproof/Dust-Ignition-Proof for Class I, II, III, Division 1 & 2, Groups A G, FF1 Class I, Zone 1, Group IIC T4 Ambient Temperature: 40 to 80 C ( 22 to 176 F) Temperature class: T4 FM Intrinsically Safe//FM Explosion-proof/ FM Dust-Ignition-Proof /FM Non-incendive Approval Conforms to: FM3600, FM3610, FMRC 3611, FM 3615, FM 3616, UL 913, UL 1203, UL 60079-0, UL 60079-11 Factory Mutual (FM) Intrinsically Safe for Class I, II, III, Division 1 & 2, Groups A - G, Zone 20, Class I, Zone 0, AEx ia IIC, T4 Ga 40 C < Ta < 80 C ( 22 to 176 F) Explosion-proof/Dust-Ignition-Proof for Class I, II, III, Division 1 & 2, Groups A - G, Class I, Zone 1, Group IIC T4 Amb. Temp.: 40 to 80 C ( 40 to 176 F) FU1 Non-incendive for Class I, II, III, Division 2, Groups A - D, F, G, Class I, Zone 2, Group IIC T4 Enclosure: "NEMA 4X", Temp. Class: T4, Amb. Temp.: 40 to 80 C ( 40 to 176 F) Intrinsically Safe Apparatus Parameters [Groups A - G] Vmax=24 V, Imax=150 ma, Pmax=0.65 W, Ci=0 nf, Li=0 H CENELEC ATEX Canadian Standards Association (CSA) Canadian Standards Association (CSA) ATEX Intrinsically Safe/ATEX Flameproof/ATEX Non-incendive Approval Applicable Standard: EN 60079-0, EN 60079-1, EN 60079-11, EN 60079-26, EN 60079-31 II 1G Ex ia IIC T4 Ga Entity parameters : Ui=24 V, Ii=150 ma, Pi=0.65 W, Ci=0 nf, Li=0 H II 2G Ex d IIC T4 Gb II 2D Ex tb IIC T135 Da II 3G Ex na IIC T4 Gc Degree of protection : IP66 and IP67 Temperature class: T4, Ambient Temperature: 40 to 80 C ( 40 to 176 F) CSA Intrinsically Safe/CSA Explosionproof/ CSA Dust-Ignition-Proof /CSA Non-incendive Approval Certified to: CSA C22.2 No. 25, CSA C22.2 No. 30, CSA C22.2 No. 157, CSA C22.2 No. 213, CSA C22.2 No. 60079-0, CAN/CSA E60079-11 Explosionproof/Dust-Ignition-Proof for: Class I, II, III; Groups A - G; Divisions 1 & 2. Class I, Zone 1, Group IIC T4. Intrinsically Safe for: Class I, Division 1, II, III; Groups A - G; Divisions 1 & 2. Zone 20, Class I, Zone 0 AEx ia IIC T4 Entity parameters: Ui=24 V, Ii=150 ma, Pi=0.65 W, Ci=0 nf, Li=0 H Non-Incendive for: Class I, II, III; Groups A - D, F, G; Divisions 2. Class I, Zone 2, Group IIC T4. Enclosure rating: "Type 4X." Temperature Class: T4 Ambient Temperature: 40 C to 80 C KU21 CU1

OPTIONAL SPECIFICATIONS (For Explosion Protected Type) IECEx Scheme IEC Intrinsically Safe/IEC Flameproof/IEC Non-Incendive Approval Applicable Standard: IEC 60079-0:2011, IEC 60079-1:2008, IEC 60079-11:2011, IEC 60079-26:2009, IEC 60079-31:2008 Explosionproof/Dust-Ignition-Proof for: Ex d IIC T4 Gb Ex tb IIC T135 Db Intrinsically Safe for: SU2 Ex ia IIC T4 Ga Entity parameters: Ui=24 V, Ii=150 ma, Pi=0.65 W, Ci=0 nf, Li=0 H Non-Incendive for: Ex na IIC T4 Gc Ambient Temperature: 40 C to 80 C Enclosure: IP66 and IP67 Combination of Approvals Combination of FU1, CU1 and KU21 Approvals V1U INMETRO (Brazil) Certificate INMETRO Intrinsically Safe/INMETRO Flameproof Approval (Pending) BU1 GOST (Russian) Certificate Russian GOST certifícate (Pending) QR1 OPTIONAL SPECIFICATIONS Paint Epoxy resin paint Polyurethane-Epoxy combination paint (Anti-corrosion coating) Note 1 X1 X2 Note 1 Calibration Calibration range and scale ENG Stainless steel tag plate Stainless steel tag screw attached to housing Stainless steel tag wired to housing Note 1: Option only available with /FF1 Option. SST SSW ORDERING INFORMATION Specify the following when ordering: 1. Model and suffix codes. 2. Option codes. 3. Tag number 4. Calibration range desired (optional) OPTIONS The MLX is fully field configurable from the front panel. To order a pre-configured unit, specify the /ENG option followed by the desired setpoints (zero, full scale, and engineering units). Example Ordering Information: MLX-A11-10/FF1/ENG/SST (Field Mounted Loop Indicator, 4 to 20mA DC, 2 Horizontal Pipe mount, aluminum housing, standard communication, ANSI ½ NPT electrical connection without blind plugs, FM Explosion-proof approval) 0-200 InH2O Scale in Engineering Units. Please specify Scale and Engineering units when ordering /ENG. FT-201 Specify Tag Number when ordering /SST and/or /SSW.

DIMENSIONS MOUNTING

WIRING The loop powered indicator series is powered by the current output loop and does not require external power. All devices must be wired in series with the current loop. Twisted pair shielded cable is recommended. The following is a typical wiring example of the MLX Loop Indicator connected to an EJA Pressure Transmitter (Note: The EJA Transmitter below can be replaced with any 4-20mA 2 wire device.