Laboratory refrigerators / freezers +4 / -20. X-Cold Series

Similar documents
Ultralow temperature freezers -86 C. Platilab & Irilab Series

Enhanced insulation thickness. Environment friendly polyurethane foam, water based foaming.

Datasheet.

Isotemp. -86 C Freezers

Model KB 400 Cooling incubators with compressor technology

Model KB 240 Cooling incubators with compressor technology

Catalogue Australia

MEDICAL Catalogue New Zealand 2015

Model KT 53 Cooling incubators with thermoelectric cooling

SO-LOW LAB FREEZERS TO -85 C

NEW! Thermo Scientific TLE Series Ultra-Low Freezers

Refrigerated incubators with forced convection

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KB 400 Cooling incubators with compressor technology

Thermo Scientific TSX Series Ultra-Low Freezers

Model KBW 720 Growth chambers with light

NEW! Thermo Scientific Forma Series Ultra-Low Freezers

SMART is the right way to do something in the Lab as well.

Model KB 400 Cooling incubators with compressor technology

Model KT 53 Cooling incubators with thermoelectric cooling

Model VD 23 Vacuum drying chambers for non-flammable solvents

BIOMEDICAL FREEZERS AND REFRIGERATORS

Heratherm Compact Microbiological Incubators

edition version 1.2 Green ICE KW Antibacteria

Model VDL 115 Vacuum drying chambers for flammable solvents

TMJ-9712 Programmable Temperature & Humidity Chamber

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

VIBRATION TEST CHAMBERS. Temperature- and Climatic Vibration test chambers. Vibration. test chambers

Thermal Shock Chambers. acstestchambers.com

Table of Contents. Chapter 1 Introduction Chapter 2 Quick Install... 7

edition version 1.2 Green ICE KW Antibacteria

Specification Sheet: HT SERIES

Customer Responsibilities

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

J7243ST 3.5GHz User Manual V1.0

Temperature Test Chambers WT3 WTS3

Ultra Low Temperature High Performance Line

GigaStor Upgradeable 2U. User Guide

MUST900 Modular UPS. Datacenter & servers. Internet centers. Local Area Networks (LAN) Telecommunication devices. Emergency application

Series IPP in four sizes: highly accurate and environmentally friendly, exceptional savings in space and energy

Vibration test chambers. TIRAvibro. Temperature- and Climatic. Vibration test chambers TIRAvibro Vibration test chambers

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

Minicen Microcen 24 Biocen 22 Biocen 22 R. About centrifugation

Environmental simulation chambers MK MKF MKT MKFT

Cooled incubators (ST), laboratory refrigerators

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Standard Operating Procedure for the Kaye Validator AVS System

Thermo Scientific Precision Incubators A wide range of incubators to fit your laboratory needs

USER GUIDE. Differential Thermometer Datalogger. Model HD200

1/6 STAINLESS STEEL SBC DIG. 316 SENSE AUDIO ENT.PAN. 3ONE6 DOOR ENTRY SYSTEMS OVERVIEW 3451AS

Snap locks and door locks

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Altitude. test chambers. acstestchambers.com. powered by

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Wolf Laboratories Limited

Customer Responsibilities

Models HP Tablet Charging Module HP Charging Module LAN Kit

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

New climatic and thermostatic chambers. powered by. acstestchambers.com

XTREME POWER CONVERSION THE VALUE LEADER IN POWER PROTECTION

SmartPro 3U Rack/Tower Extended-Run UPS Line-interactive, sine wave UPS

ZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions

HCS Newsletter No. 43, Dated Thursday, 04 December, 2003 HCS DataLine Cabinets and Enclosures

XR-CHC and XRB-CHC Refrigeration controllers with Bluetooth connectivity

Web-enabled DAQ System

Temperature Test Chambers Temp Event

Uninterruptible Power Supplies

Verderflex. Vantage Description. Your benefits. Technical specifications. Materials

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Electrical cabinets for server and LAN. 42 Lafer

Label Printer QL-810W/820NWB. Quick Setup Guide (English)

Blue e+ chillers with the principle

Now with the new CryoCube F740 series. Store More. The Eppendorf ULT Freezer Racking System

New climatic and thermostatic chambers. powered by. acstestchambers.com

Aspire V Quick Guide

AJ Series. Intelligent-Lab NTEP Centigram Balance. Made in Japan

OM-DLTT DATA LOGGER INSTRUCTIONS

18 LITER VOLUME STERILISATION MATERIALS TESTING MEDIA PREPARATION

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

STEM RS9000 Reaction Station

VTC. 200/300 Series. VTC elock controller. VTC elock Instructions. Network VTC elock has three components:

TravelNet Data/Voice Cellular Router Installation Guide ATTENTION INSTALLER

RMS WIRELESS MINI LOGGER

Consolidated Sterilizer Systems

Models 300, 310, 320, 330 PROTECTIVE AND SUPERVISION STORAGE CABINET FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

other sizes available on request

.hafele.com.sg www 1

Web: MED-CON PTY LTD SOLUTIONS FOR BIO-SECURITY. Phone: Fax:

X925. Maintenance Guide

KE2 WiFi Service Tool (pn 20906) Quick Start Guide

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

testo 175 Data loggers Instruction manual

Temperature/Humidity Agree vibration chambers

ipad Charge & Sync Cart Model MCC2 ipad Cart 430-MCC2-User Manual-010 Is a Registered Trademark of Apple Inc. ipad

GPS Vehicle and personal location tracker

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

DFSB423JMAG-RSERIES : REFRIGERATOR SHELVING [1/23]

OZLINX Solutions Australia Pty Ltd 21 Ayton Street, Sunshine North, Melbourne VIC3020 Australia Ph: Fax:

ZP 120 N. UPS 1,2,3,6,10,20 kva. online LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS

Transcription:

Laboratory refrigerators / freezers +4 / -20 Series

ANGELANTONI LIFE SCIENCE propose a wide range of professional refrigerators and freezers. This brochure includes products with capacity from 700 to 1500 liters and temperatures of +4 and -20 C, also available with two independent climatic compartments: one as refrigerator and one as freezer. The products are for laboratories use, pharmaceutical industries, hospitals, research centres or for any other kind of storage when high quality refrigerators / freezers are required. cabinets have an insulation with high density injected CFC-free PU foam of minimum 70 mm thickness. DOORS can be plain or with triple glass, always key lockable or with an optional ID card opening feature (Bioguard ). controller is state of the art with full color color display, touch keys and with full digital data recording / transferable via USB or Wi-Fi / Ethernet / 3G connections with CLOUD space too.

Laboratory refrigerators / freezers +4 / -20 Series Upright refrigerators / freezers, designed for storage of any general non-flammable laboratory materials Interiors are all made of stainless steel Designed to fulfil the Standards for storage of biological and pharmaceutical materials Constant monitoring, recording and LOG of performances Data transfer with Ethernet, Wi-Fi and UMTS/3G on Cloud server or local computer (see optional accessories) Free local data transfer via USB pen drive with proprietary encrypted software (decrypting SWR included) Auto recharging backup battery to power the electronics for up to 36h in case of a power outage lackable by key, push button or by personal card opening system (see option BIOGUARD ) Adjustable grid shelves as standard or optional sliding drawers Electronics with digital 2.5 colors display with touch keys, temperature graph view and full access to LOGGED data The models with one compartment have a single controller while those with two compartments (one at +4 C and one at -20 C) have two independent controllers & two independent cooling systems series with all possible configurations 3

Laboratory refrigerators / freezers +4 / -20 Series Technical features has a minimum insulation of 70 mm made of HD Injected PU Foam. Standard porthole with cap (diam. 23 mm) is included with all models. Heavy frame with: Exterior in plasticized zinc and coated steel, Interior of AISI 304 stainless steel with rounded corners Adjustable shelves as standard or optional S.S. sliding drawers High resistance spherical rollers for easy movement and adjustable feet Doors: Plain or with triple glass with rubber gaskets Easy one hand opening with key lock As option with ID card (see option BIOGUARD ) Automatic or manual internal light Cooling systems: All models are with internal ventilation Versions with single compartment have one compressor and one electronic Versions with two compartments (+4 and -20 C), have two compressors and two independent electronics, CFC free gases (R134a or R404A) Low noise level < 45dB Data transfer: All models have a standard USB port for free data transfer to computer USB data transfer is with encrypted file who can be read with a specific ALS software only (supplied) CLOUD server communication is available as option (see ahead) X-COLD software is also available for local use on client computers (see ahead) 700/1 TN-GL (+4 C), shown with mix of shelves and one drawer. 700/2 TN-2TS (+4/-20 C). All versions with double temperature have two independent cooling systems and two electronic controllers. 4

Technical specifications Single temperature Code Model Operating range Doors num / kind STD (shelves STD) Optional drawers Volume (single compart.) Interior dimensions WxDxH mm Exterior dimensions WxDxH mm Package dimensions WxDxH mm Net weight *with pack. Electrical 13909 13915 13916 13914 700/1 TN 700/1 TN-GL 1500/2 TN 1500/2 TN-GL +2 to +8 C +2 to +8 C +2 to +8 C +2 to +8 C 1, glass 2, plain 2, glass 3 3 6 6 up to 8 up to 8 up to 16 up to 16 700 700 1500 1500 590x675x1500 590x675x1500 1330x675x1500 1330x675x1500 740x815x1998 740x815x1998 1480x815x1998 1480x815x1998 770x900x2140 770x900x2140 1500x900x2140 1500x900x2140 140 *170 Kg 160 *190 Kg 220 *250 Kg 230 *260 Kg 50Hz 4 FLA 50Hz 4 FLA 50Hz 5 FLA 50Hz 5 FLA 13917 13918 700/1 BT 1500/2 BT -10 to -23 C -10 to -23 C 2, plain 3 6 up to 8 up to 16 700 1500 590x675x1500 1330x675x1500 740x815x1998 1480x815x1998 770x900x2140 1500x900x2140 140 *170 Kg 230 *250 Kg 50Hz 5.5 FLA 50Hz 6.0 FLA NOTE: All models are available upon request for 230 or 120 VAC, 60Hz 1500/2 TN: single temperature, +4 C refrigerator, two triple glass doors,1500 liters capacity. Double temperature Interior Exterior Package Code Operating Doors Model Shelves Optional Volume dimensions Net weight dimensions dimensions Electrical range num / kind drawers WxDxH mm *with pack. (double compart.) (per compartement) WxDxH mm WxDxH mm 13919 700/2 TN-2TS +2 to +10 C -10 to -23 C 2 2 up to 3 up to 3 350 + 350 590x675x720 590x675x720 740x815x1998 770x900x2140 140 *170 Kg 50Hz 7.2 FLA 13920 1500/2 TN-2TS +2 to +10 C -10 to -23 C 4 4 up to 6 up to 6 700 + 700 1330x675x1500 1330x675x1500 1480x815x1998 1500x900x2140 240 *260 Kg 50Hz 8.0 FLA NOTE: All models are available upon request for 230 or 120 VAC, 60Hz 1500/2 TN-2TS: double temperature, two compartments of 700 liters each (+4 C and -20 C), two plain doors, two independent cooling systems and controllers. 5

Basic optional accessories for all models Code Description Optional accessories for CLOUD data transfer and handling (internet connection) Code Description 11354 11350 12279 12280 12851 12852 12854 12855 12860 11676 12132 12680 12984 17036 17028 7-days disc recorder for dual climate versions 7-days disc recorder for single climate versions Kit for chart recorder for single climate versions (100 discs,2 pens) Kit for chart recorder for dual climate versions (100 discs,2 pens) Additional porthole 50 mm with cap One grid shelf for mix with drawers (see Note 1) Additional std grid shelf (max 10 per 700 L and 20 per 1500L) SS perforated shelf (max 10 per 700L and 20 per 1500L) SS telescopic drawer (for single T max 8 for 700 L and 16 for 1500L while for double T, 6 for 700 L and 12 for 1500 L) (see Note 1 and 2) External PT 100 probe, class A External certified PT 100 probe, class A with 3 points of temperature calibration BIOGUARD, card opening system for one door models (700L) BIOGUARD, card opening system for two doors models (1500L) Wooden cage package for 700 liters versions Wooden cage package for 1500 versions 13923 13922 13921 13924 * One of this option mutually exclude the others NOTES about the communications options: 1. Any CLOUD connection kind it is chargeable: pls ask ALS for the fee. 2. With anyone of such CLOUD options, you will get also the possibility of an automatic email sending in case of alarm. 3. By entering your private CLOUD area, you can see the entire history of your X- Cold devices (see details on Section Electronic controller). Optional accessories for LOCAL data transfer and handling (personal computer use, no internet) Code 13921 13925 * UMTS/3G module for CLOUD connection * Wi-Fi module for CLOUD connection or local computer (for CLOUD requires a router Wi-Fi with internet access) * Ethernet module for CLOUD connection or local computer (for CLOUD requires an internet access) CLOUD license for software (internet use, necessary) Description Ethernet module for CLOUD connection or local computer (for CLOUD requires an internet access) software for Windows computer (local use only) NOTES 1. By ordering one or more drawers with code 12860, it s also supplied a different set of internal supports. Such different supports cannot hold the standard grid shelves that hence must be replaced by purchasing separately some new grid shelves with code 12852, as many as needed. 2. While ordering the drawers, please specify if they are for a 700 or 1500 L version: that s necessary to include the proper internal rail (supplied free of charge with drawers). BIOGUARD system uses RFID card keyless opening. Each unit equipped with Bioguard is supplied complete with three opening cards but, additional cards are optional purchases. The BIOGUARD option increases the safety of your valuable stored products. In case of card damaging or electronic failure, there is an emergency key to open the door manually. 6

Equipment / controller Control panel of series. Bioguard reader (option) Chart recorder (option) Door key lock Display and controller Power switch and USB port The controller has three independent microprocessors: one for the cooling system, one for the alarms section and one for the data communication. The access to the parameters is password protected with three levels of privilege: users, service and administrator. The color display is 2.5 backlit with separate variable colors touch keys. The display may show a simplified view or a full graphic view, showing the set point, the alarm limits and the temperature graph too. The central LED around the programming arrows, change color upon the status of the system: GREEN > BLUE BLINKING > BLUE > RED > YELLOW > compressor OFF and internal temperature OK compressor ON start-up phase compressor ON and internal temperature OK alarm or failure status (with programmable delay) pre-alarm warning (instant, without delay) Main features of the controller Cooling system section Temperature setting and control Cooling system ON/OFF ECOMODE set to reduce the electrical consumption Automatic and programmable defrost Manual defrost Driving of internal ventilation Door s sensor Anti-condense frame heater guiding Heaters for the defrost system guiding Internal LED s light ON/OFF or automatic Alarms section Hi-Low temperature, visual and acoustic Delayed door ajar alarm Power outage or out of range Compressor failure Battery too low External free contacts for remote alarms Internal fan failure Possibility to configure an automatic email sending for alarm conditions (request one of the available Internet Cloud connections, see optional) 7

Equipment / controller Communication and data logging section: Automatic data recording up to ten years time with 30 seconds intervals of: Date and hour Temperatures of all installed probes Temperature set point value Line voltage Power consumption in VA Battery level Alarms levels or warning conditions if any Failure kind Warning messages Delta T between set temperature and real internal temperature Full statistics data of the compressor condition: working percentage, mean working time ON and OFF, total working hours, battery level. Examples of display view Temperature graph. Internet or standalone communication (options): UMTS/3G module to CLOUD server (requires SIM card, not included) Wi-Fi module to CLOUD server (requires a free Wi-Fi router for internet connection) Ethernet module for CLOUD server or to proprietary software on local computer (for CLOUD requires an internet connection) Standard USB port for data downloading to computer NOTE: the use of the CLOUD space is not free. Please ask ALS for the conditions of sales of this service. The access to the CLOUD area occurs through personal ID and password by using any internet browser via either computer, smartphone or tablet. View of programming area. Warning and Alarm messages (examples) Voltage low Temperature probes unbalanced Necessary to clean condenser LABORATORY Excessive door opening time High temperature alarm Log of an alarm condition General condition of alarm 8

Equipment / software Main features of software There are two kinds of optional software: The software to install on your computer for LOCAL data downloading / handling (Code 13925). The software for CLOUD use through internet connection (Code 13924). The LOCAL version should be installed on client computer, the communication is via Ethernet only (Ethernet cables and LAN should be provided by the customer). The CLOUD version does not require any software installation, being an online application available on internet. In both cases, what s the customer see is very similar: same user interface, same kind of data storage and handling, same functions. The LOCAL version of should be used whenever no internet connection is available while for all other cases, the CLOUD version whould be recommended. What can offer the software? LOCAL or CLOUD acquisition and storage of all data parameters (LOG file) Ethernet, Wi-Fi or UMTS/3G communication with programmable TCP/IP address Creation of a complete database on hard disk or on CLOUD server Safe Log storage and display of all events such as settings, alarms, failures, door opening Display of all temperatures graphs, line voltage, % of use of the compressors and much more Access through personal ID and password To connect any device to the computer with LOCAL, you should provide for an Ethernet hub/switch and at least two Ethernet cables (not supplied by ALS). For more units to connect, add Ethernet cables as many units you have and arrange for any proper Ethernet switch/hub. UNIT n... UNIT 3 UNIT 2 UNIT 1 (Ethernet Switch) X-COLD SWR (PC) (Ethernet cables) Schematic connection of units to computer with LOCAL X-COLD SOFTWARE 9

Biomedical refrigerators and freezers (+4 /-86 C), chambers for stability tests and LN2 robotic storage system for vials (-180 C) Refrigeration systems for industrial processes Steam sterilizers, washers and biohazard waste treatment Biosafety laminar flow cabinets Copyright 2015 Angelantoni Life Science S.r.l. / Rev. 01 - Illustration, description and technical data may be changed without notice.