Agenda 01 Product portfolio 02 Planning (1) power consumption rule (2) distance rule 03 Commissioning (1) device detail (2) commission overview a. addressing b. programming access 04 Typical sample (1) planning (2) commissioning August 23, 2017 Slide 2
01 Product portfolio
Product portfolio Indoor station Building outdoor station Villa outdoor station Mini Card reader outdoor station Guard unit Power supply IP Gateway Lift control module Relay module Management software August 23, 2017 Slide 4
02 Planning
Planning Tips 1. One power supply can support 8 ISs or 6 OSs (maximum). 2. If there are more than 1 IS in one apartment, it should need a IP Gateway. 3. If customer needs virtual indoor station function, it should need a IP Gateway. 4. If customer wants to avoid public access to their private devices(ip camera, KNX devices, etc), it should need a IP Gateway. 5. The following devices can be powered by PoE* switch or local power supply: 7 indoor station, Building outdoor station, Villa outdoor station, Mini Outdoor station. 6. The following devices can only be powered by local power supply: IP gateway, card reader, lift control, relay module, guard unit. August 23, 2017 Slide 6 Remark: PoE follows 802.3af regulation.
Planning Power consumption rule Device Powered by PoE switch Power by local PS Consumption YSM01 capacity Indoor station X X 300 ma @ 27 VDC Building outdoor station X X 400mA @ 27 VDC Villa outdoor station X X 250mA @ 27 VDC Mini outdoor station X X 400mA @ 27 VDC Card reader - X 100mA @ 27 VDC Guard unit - X 300mA @ 27 VDC Rated: 2500mA @ 27 VDC IP Gateway - X 100mA @ 27 VDC Lift control module - X 60mA @ 27 VDC Relay module - X 300mA @ 27 VDC August 23, 2017 Slide 7
Planning Distance rule LAN cable (Cat5E, Cat6, Cat7, ) Fiber-optic 100 m > 1 Km Between any two devices, support maximum 100 meters August 23, 2017 Slide 8
03 Commissioning
Commissioning Device details Indoor station 1 2 3 4 5 1. LCD display 2. Talk 3. Unlock 4. Mute 5. Message 6. Call guard 7. Set 8. Power indicator 9. Alarm indicator 10. Mute indicator 24.4 mm 1. LAN port 2. Power supply +27 VDC input +12 VDC output) 4. Door bell 5. Power status detection 6. 8 alarm zones Article. no: H82351-W White H82351-B Black H82351-G Golden August 23, 2017 Slide 10
Commissioning Device details Outdoor station 1. Camera module with light senor & illumination light 2. Acoustic module with MIC & SPK 3. 128*64 Display module 4. Push button or 4*4 keypad module 5. Interface for exit button and door status 6. Interface for local power and 2 locks connection 7. LAN port 8. Wiegand output Article no.: H81371K-S ID reader H81372K-S IC reader H81371P1-S 1 button H81372P1-S 1 button with IC / NFC H81371P2-S 2 button H81372P2-S 2 button with IC / NFC August 23, 2017 Slide 11
Commissioning Device details Mini outdoor station 1. Ring indicator 2. Communication indicator 3. Unlock indicator 4. Acoustic module with MIC & SPK 5. Push button module 6. Connector for door status, exit button and 1 st lock 7. Connector for 2 nd lock and local power supply 8. LAN port 9. Selection for tone indication and default lock Article no.: H81312P1-A 1 button with ID reader, SM H81312P2-A 2 buttons with ID reader, SM H81362P1-A 1 button with ID reader, FM H81362P2-A 2 buttons with ID reader, FM H81361P1-A 1 button August 23, 2017 Slide 12
Commissioning Device details Card reader 1. Infrared receiver 2. Indicator (Green) On for unlock Flash for setting 3. Power indicator On for normal Off for abnormal 1. Lock, Door status, Exit 2. Local power supply 3. ABB-Welcome 8 bus 4. ABB-Welcome IP bus 5. Software upgrade 6. Wiegand output 1. Device address 2. Type selection On for building Off for public 3. Wiegand On for 26 bit Off for 34 bit Article no.: YSM14-CR+ August 23, 2017 Slide 13
Commissioning Device details Guard unit 1. Power indicator 2. Microphone 3. Speaker 4. SD card slot A. Title bar B. Dial keypad C. Status bar D. Video display area 1. LAN port 2. Power supply Article No.: HSM36-GU August 23, 2017 Slide 14
Commissioning Device details Power supply 1. Battery low voltage indicator: on when the battery is low 2. Power failure indicator: on when the AC input has lost 3. Work indicator: on when the DE output is normal 4. DC output interface and status output 5. AC input interface 6. Commissioning button * 7. Fuse: Primary (F1): T3.15AL / 250V Secondary(F2): T6.3AL / 250V Article no.: YSM01-PS August 23, 2017 Slide 15
Commissioning Device details IP Gateway 1. Status indicator: When the device is powered on and the connection of indoor stations is detected, LED indicator blinks. After entering the factory reset mode, the indicator lights 3 seconds and then goes off. 1. LAN port: connect to home router 2. Uplink port: connect to ABB-Welcome IP bus 3. +27 V, GND: Power supply 4. Reset button: When the device is powered on, hold this button more than 3 s to enter the factory reset mode. Article no.: H8301 August 23, 2017 Slide 16
Commissioning Device details Lift control module 1. LED indicator Green flash for ABB- Welcome IP Red flash for ABB- Welcome 8 1. ABB-Welcome IP bus 2. ABB-Welcome 8 bus 3. RS485 BUS To 3 rd party controller To relay module Article no.: YSM23-LC August 23, 2017 Slide 17
Commissioning Commission overview-addressing Building address Floor address Apartment address Identifier Gate station / / / 1 ~ 32 Building outdoor station 000 ~ 999-7 ~ 63 / 1 ~ 64 Villa / Mini outdoor station (1) 000 ~ 999 01 ~ 63 01 ~ 32 1 ~ 4 Villa / Mini outdoor station (2) / / / 1 ~ 32 Indoor station (1) 000 ~ 999 01 ~ 63 01 ~ 32 / Indoor station (2) / / / 1 ~ 8 IP Gateway 000 ~ 999 01 ~ 63 01 ~ 32 / PMO software / / / 1 ~ 32 Guard unit / / / 1 ~ 32 Card reader (3) / / / 1 ~ 32 Card reader (4) 000 ~ 999 / / 1 ~ 9 Lift control module 000 ~ 999 / / / Relay module / / / 1 ~ 16 August 23, 2017 Slide 18 It is connected to building door entry system bus. It is connected to home router while there is IP Gateway in family. It is used for common area. It is used for dedicated building (with lift control function)
Commissioning 7 inch indoor station 1. Open any password input menu. 2. Enter password* to enter engineering mode. August 23, 2017 Slide 19 :Remark: Password should refer to online manual.
Commissioning Outdoor station 1. Enter engineering password* to enter engineering mode from stand-by menu. (345678 is the default password) August 23, 2017 Slide 20
Commissioning Mini outdoor station 1. Connect Mini outdoor station to public network bus by LAN cable 2. Press and hold the first button for 3 seconds to enter engineering mode within 3 mins after devices is power on. (If device is factory default setting, there is not 3 mins constraint) 3. Enter indoor station engineering mode and select outdoor station configuration. 4. Search & set parameter for this villa outdoor station. August 23, 2017 Slide 21
Commissioning Villa outdoor station 1. Connect villa outdoor station to indoor station directly by LAN cable 2. Press set button on villa outdoor station rear side at least 3s, during power on to enter engineering mode. 3. Enter indoor station engineering mode and select Private OS configuration. 4. Search & set parameter for this villa outdoor station. August 23, 2017 Slide 22 Remark: indoor station should not be in IPgateway mode.
Commissioning IP Gateway 1. Get its IP-address from indoor station status bar i. (or from your router device) 2. Connect your PC/Laptop/Tablet/smart home to router. 3. Open web browser and input IP-address to login. August 23, 2017 Slide 23
Commissioning Guard unit 1. Open any password input menu. 2. Enter password* to enter engineering mode. August 23, 2017 Slide 24 Remark: password should follow online manual
04 Typical sample
Typical sample Sample 1 Villa Topology Requirements: 1 Front door 1 Rear door 4 Indoor stations in basement/1st floor/2nd floor/attic 4 Apps Single villa topology Devices: 1 building Outdoor station 1 villa OS / mini Outdoor station 4 Indoor stations 1 PoE Switch 1 IP Gateway (cause need APP and multi IS) 1 Power supply (for IP gateway) August 23, 2017 Slide 26
Typical sample-1 Steps 1. Configure OS1, OS2 via IS; (IS should be in Not IP Gateway mode); 2. Configure all IS; 4. Configure phone; 3. Configure IP Gateway; August 23, 2017 Slide 27
Typical sample-1 1. Configure OS1, OS2 via IS Mini outdoor station as Rear door Press setting button " on indoor station Click "Advanced setting" then input programming password and click "OK". August 23, 2017 Slide 28
Typical sample-1 1. Configure OS1, OS2 via IS Mini outdoor station as Rear door Choose "Private OS" tab, then click "Search" to find mini outdoor station. Click "OK" to confirm. Click "Active" to take effect. If change Address, it will restart outdoor station. August 23, 2017 Slide 29
Typical sample-1 1. Configure OS1, OS2 via IS Mini outdoor station as Rear door 1 To set release time for 2 locks. (1-10 s, default is 5 s) 2 To set default lock of outdoor station. 3 ID only, support normal IC card; ID plus, support IC card with key. 4 This function is suit for the case including multi indoor stations within an apartment. If enable, new indoor stations need an authorization to release the lock. Please find details in system manual. August 23, 2017 Slide 30
Typical sample-1 1. Configure OS1, OS2 via IS Villa outdoor station as Rear door Pre-condition: This outdoor station should connect to Indoor station via LAN cable directly. 1. Press and hold set button at least 3 s when power is on. You will notice round pushbutton module light on. 2. After about 20 s, round pushbutton module flash. It means outdoor station is in engineering mode. August 23, 2017 Slide 31
Typical sample-1 1. Configure OS1, OS2 via IS Villa outdoor station as Rear door 3. Press set button on indoor station, click "Advanced setting" then input programming password* and click "OK". August 23, 2017 Slide 32 Remark: password should follow online manual
Typical sample-1 1. Configure OS1, OS2 via IS Villa outdoor station as Rear door 4. Choose "Private OS" tab, then click "Search" to find outdoor station. Click "OK" to confirm. Click "Active" to take effect. If change Address, it will restart OS.. August 23, 2017 Slide 33
Typical sample-1 1. Configure OS1, OS2 via IS Villa outdoor station as Rear door 1 To set release time for 2 locks. (1-10 s, default is 5 s) 2 To set default lock of outdoor station. 3 ID only, support normal IC card; ID plus, support IC card with key. 4 To set Wiegand output format 5 This function is suit for the case including multi indoor stations within an apartment. If enable, new indoor stations need an authorization to release the lock. Please find details in system manual. August 23, 2017 Slide 34
Typical sample-1 2. Configure all IS 1. Press set button on indoor station, click "Advanced setting" then input programming password and click "OK". 2. Stick IP Gateway, and then fill in different ID No for each IS, e.g. 01, 02, 03, 04. August 23, 2017 Slide 35
Typical sample-1 3. Configure IP Gateway IP Gateway setup 1) Connect wifi of the route 2) Login IP-Gateway by admin. You can find IP-gateway address via pressing I on the left and press I again on the right. 3) Add user and assign permission from user management entry. August 23, 2017 Slide 36
Typical sample-1 3. Configure IP Gateway IP Gateway setup August 23, 2017 Slide 37
Typical sample-1 3. Configure IP Gateway IP Gateway setup August 23, 2017 Slide 38
Typical sample-1 3. Configure IP Gateway IP Gateway setup 4) Enter the specified DynDNS address in the "External IP / Hostname" field from Network configuration entry (option for remote access) 5) Logout IP-Gateway by admin. 6) Login IP-Gateway by user added in previous step, then there is one configuration QR code over there. August 23, 2017 Slide 39
Typical sample-1 4. Configure phone APP installation You can down load the app for your smartphone / tablet via the following two ways: scan QR code on the indoor station from status bar i. There will be two QR code, one for IOS, another one for Android. You can input busch jaeger into APP store to search for an APP named Welcome App, and down load. IOS Android August 23, 2017 Slide 40
Typical sample-1 4. Configure phone APP configuration 1) Open the app 2) Click setting/network settings 3) Click Quick configuration with QR-code and scan the QR code available in 1st step.(option) Enter IP-Gateway IP address, user name and password added in 1st step, August 23, 2017 Slide 41
Typical sample-2 Overview Requirements: 4 Buildings - 30 floors per building - 8 apartments per floor - 5 entries on 1st floor 1 guard house 5 gate Devices: 960 Indoor stations (1*8*30*4) 25 Outdoor station (5*4+5) 1 Guard Unit 1 Power supply 121 PoE Switch (30*4+1) August 23, 2017 Slide 42
Typical sample-2 1. Connect all devices Residential complex topology Building A Guard house Building B Building C Building D August 23, 2017 Slide 43
Typical sample-2 Steps 1. Configure indoor stations 3. Configure Guard Unit 2. Configure outdoor stations and gate stations August 23, 2017 Slide 44
Typical sample-2 1. Configure indoor stations Press setting button " on indoor station Click "Advanced setting" then input programming password and click "OK". August 23, 2017 Slide 45
Typical sample-2 1. Configure indoor stations Configure each indoor station. Fill in Block No and Unit No for each indoor station. All IS within the same building should have the same Block No, and different Unit No for different apartment. August 23, 2017 Slide 46
Typical sample-2 1. Configure indoor stations Building 1 Building 2 Building 3 Building 4 001-0101, 002-0101, 003-0101, 004-0101, 001-0102, 002-0102, 003-0102, 004-0102, 001-0108, 002-0108, 003-0108, 004-0108, 001-0201, 002-0201, 003-0201, 004-0201, 001-0202 002-0202 003-0202 004-0202 001-0208; 002-0208; 003-0208; 004-0208; 001-3001, 002-3001, 003-3001, 004-3001, 001-3002, 002-3002, 003-3002, 004-3002, 001-3008; 002-3008; 003-3008; 004-3008; August 23, 2017 Slide 47
Typical sample-2 2. Configure outdoor stations and gate stations Gate station No: 01, 02, 03, 04, August 23, 2017 Slide 48
Typical sample-2 2. Configure outdoor stations and gate stations Building 1 Building 2 Building 3 Building 4 Block No: 001; Block No: 002; Block No: 003; Block No: 004; Device No: Device No: Device No: Device No: 01, 01, 01, 01, 02, 02, 02, 02, 03, 03, 03, 03, 04, 04, 04, 04, 05, 05, 05, 05, August 23, 2017 Slide 49
Typical sample 3. Configure Guard Unit 1. 2. Press Unlock button and input password* Set guard unit No here. August 23, 2017 Slide 50