Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Similar documents
Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Safety sensor BNS About this document. Content

Operating instructions Safety sensor EX-BNS40S. 1. About this document. Content

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Hinge safety switch TESZ. 1. About this document. Content

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Operating instructions Position switches EX-Z/T G/D. 1. About this document. Content

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 100DR. 1. About this document. Content

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions Fail-safe standstill monitor FWS About this document. Content

Operating instructions Safety switch with interlocking function MZM 100 B. 1. About this document. Content

Operating instructions Safety switch with interlocking function AZM 200D. 1. About this document. Content

Operating instructions Solenoid interlock MZM About this document. Content

Operating instructions Safety-monitoring module SRB 301MC SRB 301MC-ST. 1. About this document. Content

Operating instructions Safety mats SMS 4 SMS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Solenoid interlock MZM 100 MZM 100 B. 1. About this document. Content

Operating instructions Solenoid interlock AZM 200 T. 1. About this document. Content

Operating instructions Safety-monitoring module SSW 301HV. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions Two-hand control panel and stands. SEPK02.0 / SEPG05.3 / SEP01.0 /SEP01.4 / SEPLC05.2 / SEP07.0 / SEP09.

Operating instructions Electromagnetic solenoid interlock MZM 100 AS. 1. About this document. Content

Operating instructions (short version) Safety monitor AS-Interface Safety at Work ASM E1-R2 ASM E2-R2/R2. 1. About this document.

Operating instructions Safety-monitoring module SRB 301LC/B SRB 301LC/B-R. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301LC / LCI / LCI/7. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 301ST-230V. 1 About this document

Operating instructions Safety-monitoring module SRB301STV.2 /CCV.2 /PCV.2 SRB301STV.3 /CCV.3 /PCV About this document.

Operating instructions Safety-monitoring module SRB 301ST V.2. 1 About this document

Operating instructions Safety-monitoring modules SRB201ZH -24VDC. 1. About this document. Content

Operating instructions Safety-monitoring module SRB 324ST V About this document. Content

Operating instructions Safety sensor RSS About this document. Content. 7 Set-up and maintenance 7.1 Functional testing 8 7.

Operating instructions Safety-monitoring module SRB 207AN. 1. About this document. Content

Operating instructions Safety-monitoring module SRB-E-204ST / SRB-E-204PE. Content. 1. About this document

Operating instructions Safety-monitoring module SRB 301HC/R-24V / -230V. 1 About this document

Operating instructions Safety-monitoring module SRB 324ST V.3. 1 About this document

Operating instructions Command and signalling devices. E programme, N programme and R programme. 1. About this document. Content

Operating instructions Safety light curtain / safety light grid SLC440COM SLG440COM. Version 2.0. Content. 1. About this document

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Datasheet - BNS ZG

Encontrará el manual de instrucciones actual en su idioma oicial de la UE en nuestra página de Internet

Datasheet AZM 161 Z ST1 AS RA

SR B series coded magnetic safety sensors

Datasheet - AZ 16-02ZVRK-ST

Datasheet - BNS ZG-ST

Datasheet - AZ 16-03ZVRK

SR A series coded magnetic safety sensor

Datasheet - AZ 15 ZVRK

Operating instructions Safety light barriers SLB440. Content. 1. About this document

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Datasheet - RSS 36-D-R-ST

Datasheet - MZM 100 B ST2-1P2PW2RE-A

Datasheet - AZM300Z-ST-1P2P-A

Position detection with system The new compact position switches PS116

Datasheet - AZ 16-02ZVK

Datasheet - SRB 301LC/B-24V

Datasheet - SRB 402EM-24V

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

Datasheet - AZ 15 ZVRK

Datasheet SRB301ST 24V (V.2)

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Datasheet - AZ 15 ZVK

Safety coded magnetic sensor SR A series

Operating instructions. Switching amplifier DN0210 DN / / 2015

Datasheet - AZM 200 BZ ST-T-AS P

Datasheet - MZM 100 B ST-1P2PW2REM-A

Safety coded magnetic sensor SR B series

Safety coded magnetic sensor SR B series

BNS SERIES - COMPATIBLE SERIES AES SAFETY CONTROLLERS SELECTION CHART AVAILABLE STANDARD MODELS

Datasheet - AZ 16ZVRK

Operating instructions Joystick switch RK/NK. 1. About this document. Content

Operating instructions Safety light curtain / safety light grid SLC445 SLG445. Content

Operating Instructions

Safe switching and monitoring Non-Contact Safety Sensors

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Datasheet - AZ 15 ZVRK

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Operating instructions. Speed monitor D / / 2014

Ordering details. Approval. Classification. Global Properties :27:33h. Solenoid interlock / AZM 161I / AZM 161I B6R

Datasheet - CSS 11-30S-D-M-ST

Datasheet - AZM 200SK-T-1P2PW

Datasheet - SLB 200-C04-1R

Online data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES

Safety coded magnetic sensor SR A series

Operating Instructions

Coded magnetic safety sensor SR B series

SolConeX extra-low voltage flange socket

AS-i Safety Relay Output Module with Diagnostic Slave

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Position detection with system The new compact position switches PS116

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet

Non-Contact Guard Monitoring Safety System BNS/AES

Safety System CES-FD. Non-contact safety system CES-FD- Direct connection to decentralized peripheral systems (e.g. ET200pro) PLC

Transcription:

6 Disassembly and disposal 6.1 Disassembly....6 6.2 Disposal...6 7 EU Declaration of conformity Operating instructions.............pages 1 to 8 Original x.000 / 09.2017 / v.a. - 101178533- / I / 2017-08-31 / AE-Nr. 8046 Content 1 About this document 1.1 Function...1 1.2 Target group: authorised qualified personnel....1 1.3 Explanation of the symbols used...1 1.4 Appropriate use...1 1.5 General safety instructions...1 1.6 Warning about misuse...2 1.7 Exclusion of liability...2 2 Product description 2.1 Ordering code...2 2.2 Special versions....2 2.3 Purpose...2 2.4 Technical data...2 2.5 Safety classification...2 3 Mounting 3.1 General mounting instructions...3 3.2 Dimensions...3 3.3 First assembly...4 3.4 Maintenance and service....4 3.5 Adjustment....5 4 Rear side Electrical connection 4.1 General information for electrical connection....5 4.2 Contact variants....5 4.3 Connection....5 4.4 Connector plug....5 5 Set-up and maintenance 5.1 Functional testing....6 5.2 Maintenance...6 1. About this document 1.1 Function This operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. The operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 Target group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: This symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. 1.4 Appropriate use The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant. The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description". 1.5 General safety instructions The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. The information contained in this operating instructions manual is provided without liability and is subject to technical modifications. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1

1.6 Warning about misuse In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. The relevant requirements of the standard ISO 14119 must be observed. 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 2. Product description 2.1 Ordering code This operating instructions manual applies to the following types: -➀Z➁-➂-➃ No. Option Description ➀ 11 1 NO / 1 NC 12 1 NO / 2 NC 02 2 NC ➁ without LED G with LED ➂ connecting cable bottom H connecting cable back ST M12 connector bottom ➃ L for left hinged doors R for right hinged doors 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. 2.3 Purpose The safety sensor is designed for application in safety circuits and is used for monitoring the position of movable safety guards to ISO 14119 and IEC 60947-5-3. To actuate the safety sensors, only the -B01 actuator can be used, conventional magnets are not suitable. The safety sensors are used for applications, in which the hazardous situation is terminated without delay when the safety guard is opened. The safety switchgears are classified according to ISO 14119 as type 4 interlocking devices. The entire system consisting of the safety door handle switch and the safety-monitoring module (AES, SRB) meets the requirements of the standard IEC 60947-5-3. The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level. The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards. 2.4 Technical data Standards: IEC 60947-5-3, BG-GS-ET-14 Enclosure: glass-fibre reinforced thermoplastic Protection class: IP67 to IEC 60529 Termination: LIYY cable or M12 connector Connecting cable: 4 x 0.25 mm² with signalling contact: 6 x 0.25 mm² Integrated connector: M8 x 1, 4-pole with signalling contact: M8 x 1, 8-pole Operating principle: magnetic Actuator: -B01 Coding level according to ISO 14119: low Switching distances: - Assured switching distance s ao : 0 mm - Assured switch-off distance s ar : 22 mm Switching condition indication: LED only with ordering suffix G Rated insulation voltage U i : 32 V Rated impulse withstand voltage U imp : 0.8 kv Switching voltage: with connector: max. 24 VDC with connector and LED: max. 24 VDC with cable: max. 110 VAC/DC with cable and LED: max. 24 VDC Switching current: without LED: max. 250 ma with LED: max. 10 ma Switching capacity: without LED: max. 3 W with LED: max. 240 mw Required short-circuit current: 100 A Ambient temperature: 25 C... +70 C Storage and transport temperature: 25 C... +70 C Max. switching frequency: 5 Hz Resistance to shock: 30 g / 11 ms Resistance to vibration: 10... 55 Hz, amplitude 1 mm Max. door weight: Hinged guard: 5 kg; sliding guard:3 kg 2.5 Safety classification Standards: ISO 13849-1 Safety contact: - NC / NC combination: S11-S12 and S21-S22 - NC / NO combination: S21-S22 and S13-S14 Intended structure: - 2-channel usage: usable to cat. 4 / PL e with suitable logic unit B 10D NC contacts at 20 % contact load: 25.000.000 B 10D NO contacts at 20 % contact load: 25.000.000 Service life: 20 years MTTF D B10D dop x hop n x 3600 s/h op 0,1 x n op t cycle (Determined values can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) If multiple safety components are wired in series, the Performance Level to ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances. 2

3. Mounting 3.1 General mounting instructions During fitting, the requirements of ISO 14119 must be observed. 3.2 Dimensions All measurements in mm. Sensor with connector, right hinged door - The door-handle switch is only suitable for use on smaller low-weight safety guards, max. door weights: hinged door: 5 kg; sliding door: 3 kg. - Fitting is only authorised in a de-energised condition - Any mounting position, provided that the active surfaces are opposite - Exclusively mount the sensor on flat surfaces to avoid tensile stresses that could damage the sensor or lead to varying switching distances - Do not install the safety sensor and the actuator in strong magnetic fields - If possible, do not mount the sensor and the actuator on ferromagnetic material. The use of a non-magnetic spacer of at least 5 mm thick must be used. The use of non-magnetic fixing screws is recommended also. - Do not subject the safety sensor and actuator to extreme vibrations and shocks. - Keep away from metal chips. - The mounting distance between two sensors should always be at least 50 mm 43,3 32,4 LED 8,5 120 99 62 10 5 7,7 40 17 108 119,5 82 Safety sensor and actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads). The required M5 hexagonal screws and washers for the fixation are not included in delivery. Sensor with cable at the back 4,1 42 20 35,5 25 12 9 5,2 5 83 108 43,5 32,5 99 54 82 120 R1 16 11,5 40 40 120 16,5 3

3.3 First assembly Step 1 Drill according to the drill pattern: 4 x M5 (if necessary) and screw the sensor unit tightly to the door frame using hexagonal screws DIN912-M5 (min. length 16 mm) Step 2 Slide and latch the plates (screw cover) of the sensor in the hole Step 3 Remove the spring from the handle. Use screwdriver to remove the handle Step 4 Loosely tighten the handle unit by means of hexagonal screws DIN912-M5, so that it can be aligned afterwards. Step 5 Align the handle unit with the sensor unit(top of sensor unit and handle unit at the same height) Step 6 Press down the handle, so that it latches. Accurately align the handle unit with the sensor. Tighten the handle unit using the supplied hexagonal key. Step 7 Put back the spring in the handle unit Step 8 Connect to the AES safetymonitoring module (connector) 3.4 Maintenance and service Step 1 Unplug the connector Step 2 Remove the plates of the sensor using a screwdriver, unscrew the device (if necessary) Step 3 Remove the spring from the handle. Step 4 Remove the handle using a screwdriver, unscrew the device (if necessary). Procedure for fixing: refer to first assembly 4

3.5 Adjustment The LED of the variants can only be used as a rough setting tool. The correct functionality of both safety channels must be checked by means of the connected safety-monitoring module. Recommended Adjustment Align the safety sensor and actuator at a distance of 0.5 x s ao. 4. Rear side Electrical connection 4.1 General information for electrical connection The electrical connection may only be carried out by authorised personnel in a de-energised condition. The safety sensors must be wired in accordance with the wire colours or the pin configuration. 4.2 Contact variants The contact position shows the actuated sensor function when the safety guard is closed. For safety sensors with LED, the LED is illuminated when the safety guard is closed. Safety contacts: Signalling contact: S21-S22 and S11-S12 or S13-S14 S31-S32 The numbers between brackets indicate the PIN configuration of the versions with integrated connector; indication of the wire colours for the version with cable. Connection to safety-monitoring modules with NC/NC input NC: S21 - S22 to the 1st NC input of the safetymonitoring module (AES safetymonitoring module: terminal S21 - S22) NC: S31 - S32 to the 2nd NC input of the safetymonitoring module (AES safetymonitoring module: terminal S11 - S12) NO: S13 - S14 can be used as a signalling contact Depending on the termination of the safety sensor, the coding is ensured in this way. Inductive loads (e.g. contactors, relays, etc.) are to be suppressed by means of a suitable circuit. Information for the selection of suitable safety-monitoring modules can be found in the Schmersal catalogues or in the online catalogue on our website: www.schmersal.net. Connecting multiple safety sensors to one AES safetymonitoring module is technically possible. To connect multiple safety sensors (check if authorised!), their NO contacts are wired in parallel and their NC contacts in series. The Protect-IE-11 or -02 or PROTECT-PE-11(-AN) or -02 input expander module can be used to connect up to 4 safety sensors with NC/NC or NC/NO contacts. safety sensors equipped with LED's should not be wired in series, except with the Protect-IE input expander module. As a result of this, the luminosity of the LED's would considerably decrease and the voltage could drop below the minimum input voltage of the downstream safety-monitoring module. -11Z (3) BK S13 (1) WH S21-12Z (3) GY S13 (1) GN S21 (5) WH S31-02Z (3) BK S11 (1) WH S21 S14 BU (4) S22 BN (2) S14 PK (4) S22 YE (2) S32 BN (6) S12 BU (4) S22 BN (2) -11ZG (3) BK S13 (1) WH S21-12ZG (3) GY S13 (1) GN S21 (5) WH S31-02ZG (3) BK S11 (1) WH S21 S14 BU (4) S22 BN (2) S14 PK (4) S22 YE (2) S32 BN (6) S12 BU (4) S22 BN (2) 4.4 Connector plug Integrated connector M12, 8-pole M12, 4-pole 6 7 1 5 8 4 3 2 4 1 3 2 4.3 Connection The -12z(G) can be used on safety-monitoring modules with NO/NC inputs or on safety-monitoring modules with two NC inputs, at the user's discretion. Depending on the type of safety-monitoring module, the sensors must be wired as shown below. Depending on the chosen safety-relevant contacts, an additional NC or NO contact is available for signalling purposes. For safety sensors with LED, the LED is located in S21 S22 and the LED will be on when the safety guard is closed. Connection to safety-monitoring modules with NO/NC input NO: S13 - S14 to the NO input of the safety-monitoring module (AES safety-monitoring module: terminal S13 - S14) NC: S21 - S22 to the NC input of the safety-monitoring module (AES safety-monitoring module: terminal S21 - S22) NC: S31 - S32 can be used as a signalling contact 5

5. Set-up and maintenance 5.1 Functional testing The safety function of the safety sensor must be tested. The following conditions must be previously checked and met: 1. Fitting of the sensor and the actuator 2. Fitting and integrity of the power cable 3. The system is free of dirt and soiling (in particular metal chips) 5.2 Maintenance In the case of correct installation and adequate use, the safety sensor features maintenance-free functionality. A regular visual inspection and functional test, including the following steps, is recommended: Check the fitting of the sensor and the actuator Remove possible metal chips Check the cable for damage. Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators. Damaged or defective components must be replaced. 6. Disassembly and disposal 6.1 Disassembly The safety switchgear must be disassembled in a de-energised condition only. 6.2 Disposal The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. 6

Safety sensor 7. EU Declaration of conformity EU Declaration of conformity Original K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. Name of the component: Type: See ordering code Description of the component: Coded safety-sensor with magnetic operating principle in combination with the AES / AZR / SRB safety-monitoring modules from Schmersal or an equivalent safety-oriented control system fulfilling the requirements of the IEC 60947-5-3. Relevant Directives: Machinery Directive RoHS-Directive 2006/42/EC 2011/65/EU Applied standards: DIN 60947-5-3: 2014, DIN ISO 14119: 2014 Person authorised for the compilation of the technical documentation: Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, July 20, 2017 -D- Authorised signature Philip Schmersal Managing Director The currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. 7

K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 63, D - 42232 Wuppertal Phone: +49 - (0)2 02-64 74-0 Telefax: +49 - (0)2 02-64 74-1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com