VThis A PP NOTE USING FLIPFACTORY WITH SEACHANGE BMLE SERVERS

Similar documents
VThis A PP NOTE PROCESSING DPX FILES IN FLIPFACTORY WORKFLOWS

VThis App Note ADMANAGER AND NOVAR INTEGRATION. App Not e. Synopsis...2 Workflow Overview...2

USING AVID TRANSFER MANAGER/ENGINE VERSION 2.6 WITH FLIPFACTORY

USING AVID TRANSFER MANAGER/ENGINE VERSION 2.4 WITH FLIPFACTORY

VThis App Note USING STYLESHEETS IN FLIPFACTORY. App Not e

VThis App Note USING VANTAGE PLAYBACK SERVICE FOR AVID INTERPLAY TRANSFER ENGINE. App Note

USING AVID V2.6 TRANSFER ENGINE WITH VANTAGE

USING VANTAGE PLAYBACK SERVICE FOR AVID INTERPLAY TRANSFER ENGINE

VThis A PP NOTE FLIPSCAN OPTION

Flip4Mac Image Server Component

Application Note Configuring the Netopia R2020 for use with ClipMail Pro and ClipExpress

CaptionMaker Installation and Activation

USING FLIPFACTORY PLAYBACK SERVICE FOR AVID INTERPLAY TRANSFER ENGINE

Vantage. Software Version 5.0 Release Notes

FlipFactory. Software Version 7.2 Release Notes

USING FLIPFACTORY PLAYBACK SERVICE FOR AVID INTERPLAY TRANSFER ENGINE

Nortel Media Application Server 5.1. Installation NN

Vantage. Software Version 4.0 R3 Release Notes

Captioning in Episode

4.0 R3. Domain Management Guide

Flip4Mac XDCAM. Components Version 2.1 T E L E S T R E A M Telestream, Inc.

Online Backup Manager v7 Quick Start Guide for Synology NAS

Application Note Configuring the Ascend MAX800 for use with Clipmail in a private network

Avigilon Control Center Server User Guide

IP Device Search and Configuration Tool Operation Manual

BACKUP APP V7 QUICK START GUIDE FOR SYNOLOGY NAS

USING FLIPFACTORY PLAYBACK SERVICE FOR AVID INTERPLAY TRANSFER ENGINE

Wireless-G Router User s Guide

User s Guide. Version 1.0 T E L E S T R E A M Telestream, Inc.

User Guide MXF MXF Import Component V 1.0

Application Note. Connecting ClipRemote to a Modem, Terminal Adapter, or Satellite Data Terminal using a Windows 2000 PC.

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

VBDirectory MPEG-1, 2, 4 & WM. VBDirectory Users Guide Version 4.1. June 27,

X Series & V5 Application Note 18:

User Guide. Illustra Connect Version C0

Content Delivery Solutions Pinnacle MediaStream

Important Information

Online Backup Manager v7 Office 365 Exchange Online Backup & Restore Guide for Windows

GiftMaker Pro & EventMaker Pro 8.2

BSc Year 2 Data Communications Lab - Using Wireshark to View Network Traffic. Topology. Objectives. Background / Scenario

Lightspeed Live Capture

Installation and Configuration Guide

akkadian Provisioning Manager Express

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Reuters WNE Client v.4.1

Installing the Tibbo Device Server Toolkit

Smart Control Center. User Guide. 350 East Plumeria Drive San Jose, CA USA. November v1.0

Print Manager Plus 2010 Workgroup Print Tracking and Control

Videon Product Manual. Shavano Encoder

Thrive Job Editor Workstation

DNA. Release Notes. Version

Express Report Service / Installation Guide (Windows) Express Report Service. Chapter 1 General Description. Chapter 2 Installation

User Guide. VNM Software Decoder. Streaming AV Products. Software Decoder for VN-Matrix 200 Series and 225 Series Rev.

itx Integrated Playout Platform

Management Software AT-S79. User s Guide. For use with the AT-GS950/16 and AT-GS950/24 Smart Switches. Version Rev.

Cisco TelePresence Management Suite Extension for Microsoft Exchange

AnySite. Australia. Install Guide. AnySite v9.1 Install Guide

Polycom RAS200A. Administrator s Guide

Avigilon Control Center Server User Guide

ProcessLogix R510.0 Server Installation Instructions

Episode Engine & Final Cut Server

Installing Komplete 5 with Direct Install

BACKUP APP V7 CLOUUD FILE BACKUP & RESTORE GUIDE FOR WINDOWS

Atlona Manuals Software AMS

Oracle Database Firewall. 1 Downloading the Latest Version of This Document. 2 Known Issues. Release Notes Release 5.

Galileo Print Manager Installation Guide

Installation and Configuration Guide

Meridian 6.4. Quick Configuration Guide DVTEL INC. 65 Challenger Road. Ridgefield Park, NJ 07660

Omneon MediaBridge. Installation and User s Guide Release ( )

ProSafe Plus Switch Utility

Scholastic Reading Inventory Installation Guide

HOW TO: Establishing a VPN Connection For use with File Sharing on Windows 98, 2000, and Windows XP

The Administration Tab - Diagnostics

Mupgrade Utility. Minislot Transverse For Network Management Card User Manual

READ ME FIRST. Windows NT. *DSL Equipment Installation Guide: Efficient Networks 5260

Wireless USB Port Multi-Functional Printer Server. Model # AMPS240W. User s Manual. Ver. 1A

KEPServerEX V6 Install Guide

Management Console User s Guide (AST 2500 Chipset)

Data Converter. For 8 Series Mobile Computers. Version 3.02

System Monitoring Plug-in Installation Guide for Microsoft Internet Information Services Release 4 ( ) Versions Supported

Management Software AT-S101. User s Guide. For use with the AT-GS950/8POE Gigabit Ethernet WebSmart Switch. Version Rev.

SonicWall Secure Mobile Access SMA 500v Virtual Appliance 8.6. Getting Started Guide

Network Scanner Tool V3.3. User s Guide Version

License Manager Client

Remote Access System for STAM-2 Monitoring Station STAM-VIEW

Datacard XPS Card Printer Driver Guide

Installation of Cisco Business Edition 6000H/M

Silk Performance Manager Installation and Setup Help

Integrated Playout and Media Asset Management

Videon Product Manual

READ ME FIRST Windows 95/98/Me/2000

271 Waverley Oaks Rd. Telephone: Suite 206 Waltham, MA USA

AXIS T8705 Video Decoder. User Manual

A specific IP with specific Ports and Protocols uses a dedicated WAN (Load Balance Policy).

Oracle DIVArchive Suite

Vantage Feature Spotlight: Advanced Task Scheduling

Testing and Restoring the Nasuni Filer in a Disaster Recovery Scenario

AT-S41 Version 1.1.7C Management Software for the AT-8326GB and AT-8350GB Series Fast Ethernet Switches. Software Release Notes

AT-S79 Version ( ) Management Software for the AT-GS950/16 and AT-GS950/24 Gigabit Ethernet Smart Switches Software Release Notes

Installing and Using Document Distributor

Transcription:

A PP NOTE USING FLIPFACTORY WITH SEACHANGE BMLE SERVERS Introduction...2 FlipFactory and BMLe Versions...2 Connecting FlipFactory & BMLe via FSI...3 Verifying FTP Connectivity...5 Playing Out Direct-Convert Media with Inband Closed Caption...6 Appendix A Using EXD to Locate Files...8 Appendix B Finding the CIFS NAME...9 Contacting Telestream...11 Contacting SeaChange Customer Service...11 VThis App Note applies to FlipFactory version 5.0 & Later April, 2007 2007 Telestream, Inc. P/N 74-0091-00 2007 Telestream, Inc. Page 1

Introduction FlipFactory users can configure FlipFactory to connect to SeaChange Broadcast MediaLibrary (BMLe) Platform for establishing a variety of digital media workflows. This app note provides information about configuring and validating connections with BMLe servers as a source or destination, and playing out media with inband closed captioning correctly in certain circumstances. The app note also describes how to use the EXD utility to locate files. Connectivity to a BMLe server is established via the BMLe s service network or via the File System Interface (FSI) card. The choice to use the service network or FSI network is primarily based on your volume requirements. Service network connections may be satisfactory for low-volume workflows. For higher-volume workflows, the FSI network connection is recommended. Jumbo Frames must be enabled to most efficiently interface to the FSI network Note: You should only consider using the service network when all FSI cards are utilized contact SeaChange or Telestream for assistance. You can configure FlipFactory factories to use a BMLe server as a destination for encoded media files, and you can also configure factories to use a BMLe server as a monitor (source system) when ingesting file-based media for processing. When used as a monitor, you can set up FlipFactory to automatically ingest media files stored in a directory. Alternatively, you can manually submit jobs by browsing to the target directory and selecting the media you want to submit. When playing out media from the BMLe server that has been direct-converted by FlipFactory, in certain circumstances, you may have to modify the BMLe server settings to play out inband closed-captioning on line 21. This app note provides information and steps required to connect with the BMLe server as a source or destination. Not all the steps described may be necessary in your situation, but they are included for completeness. Communication between FlipFactory and SeaChange servers is affected by your choice of operating system, your network configuration, and your security requirements. FlipFactory and BMLe Versions Functionality described in this app note can be implemented using FlipFactory Version 5.0 with update BMLe Transport Plugin Update 5024474 (included in FlipFactory Update Pack 1, published 8/24/06 at www.telestream.net for registered users), or in FlipFactory Version 5.1 or later. Note: The use of user names and passwords to access BMLe servers as a destination with Directory Server installed is not supported in Version 5.1, but may be supported in future versions of FlipFactory. You should only connect FlipFactory with SeaChange Broadcast System Version 3.1 or later. If you are not using a permitted version, please contact SeaChange customer service to upgrade, before integrating with FlipFactory. Introduction 2007 Telestream, Inc. Page 2

Connecting FlipFactory & BMLe via FSI To connect FlipFactory with a BMLe server s FSI network via an FS port, perform these tasks: Networking Options To establish network connectivity, you can change the IP address of the FSI port cards or the IP address of the FlipFactory server. To change the IP address of the BMLe FSI ports, contact SeaChange Customer Service for specific addresses. You can also install and configure a second Ethernet interface card in the FlipFactory server with a valid IP address in the required subnet. Alternatively, establish a direct connection for optimal network traffic. For a single FlipFactory server on a sparse system (with few decoders) a direct connection performs well. If the network is dense, it is best to use a switch. For redundant installations with two (or more) FlipFactory servers, use two switches connected to FSI ports located on separate BMLe nodes. For example: FSI 3 on Node 0 (primary), FSI3 on Node 2 (backup). Ensure Connectivity using GbE with Jumbo Frames Enabled Make certain that your FlipFactory server has a Gigabit Ethernet card. Ideally, the FlipFactory network interface is connected directly to the BMLe server, or both servers are connected to a single GbE switch. Your FlipFactory server may require a second Ethernet NIC to accommodate the IP addresses on the FSI card, and the IP address and subnet mask must be set correctly. Note: You can connect with 10/100MB Ethernet as well, but performance is impaired. In this situation, set the FSI card to not use jumbo frames for best performance. You should also have jumbo frames enabled (Advanced settings). FSI cards are optimized for jumbo frames set at 9000 bytes. If jumbo frames are not enabled on all equipment along the route, transfer performance is significantly reduced often performing more slowly than the 100MB Ethernet connection. Identify the BMLe Server FSI Port Each node (BMLe) has four FSI cards (numbered port 0 to 3). Identify the FSI port on the node to use for transferring media between the FlipFactory server and the BMLe server. Typically, you ll use port 3 (card 4), because cards 1, 2, and 3 are reserved for playout. Card 4 (port 3) is usually reserved for other uses such as FlipFactory connectivity. Note: File transfers with FlipFactory should not be conducted on the same card where one port is dedicated to a codec. For best performance, don t mix video encoding with file transfers. Any FSI card used for video I/O to a MediaClient (MCL) may NOT be used for file transfers to and from FlipFactory or other third-party devices. Obtain the IP address of the FSI port you plan to use, plus the CIFS card name, for use throughout the configuration process (Appendix B Finding the CIFS NAME on page 9). If you are unsure of which FSI port to use, contact SeaChange Customer Service (Page 11). Ping the SeaChange Server Before configuring FlipFactory, you should verify network connectivity between the FlipFactory server and the BMLe server by using PING. Verify that you can ping the FSI card from the FlipFactory server using its IP address before continuing. Connecting FlipFactory & BMLe via FSI 2007 Telestream, Inc. Page 3

Configure the FlipFactory Server Hosts File Telestream recommends against using a host name to identify the BMLe server via DNS. If you plan to use the IP address to connect to the BMLe server, skip this step. If you plan to use the CIFS card name in FlipFactory, you should update the hosts file on the FlipFactory server with the IP address and card name to identify the BMLe server locally. Note: To obtain the host name, find the FSI card CIFS name using Seaview, which runs on the SeaChange BOSS computer (Appendix B Finding the CIFS NAME on page 9). Use this CIFS card name and IP address to update the hosts file. Update the FlipFactory server s hosts file with the CIFS card name and IP address for the target BMLe node FSI card. (A hosts file is a text file which contains entries that map host names to IP addresses without using DNS.) Use Notepad (or other text processor) to open the hosts file in either operating system: Windows 2000 / 2003 Server. <System Drive>:\WINNT\SYSTEM32\DRIVERS\ETC\HOSTS Windows XP. <System Drive>:\WINDOWS\SYSTEM32\DRIVERS\ETC\HOSTS Figure 1. Configure your hosts file with a BMLe FSI Port entry Add an entry for each node s FSI port in the form: <IP Address> <BMLe FSI card name>. (An entry for the SeaChange BOSS computer is not required.) Note: You can also use the entries in the hosts file on the SeaChange nodes as a guideline, because it should have the system's current IP configuration. Connecting FlipFactory & BMLe via FSI 2007 Telestream, Inc. Page 4

Verifying FTP Connectivity Verify that you can connect to the BMLe server via FTP and display the directory on the server. Open a DOS window on the FlipFactory server and enter FTP <IPADDR NAME>, where <IPADDR NAME> is the IP address (or BMLe FSI card name or computer name if you added an entry to the hosts file). Logging in via FSI When you re connected to the data network via FSI, enter anonymous and press Enter when prompted for the username and just press enter when prompted for the password. Logging in via FSI with Directory Server Enabled If your BMLe server has an optional Directory Server attached, username and password security may be enabled. When you log on, you ll need to supply the username and password for the directory you re accessing. Displaying the Directory Next, type DIR and press Enter to display the directory contents. If the directory displays, FTP connectivity is established. If not, determine what is wrong and retry. Verifying FTP Connectivity 2007 Telestream, Inc. Page 5

Playing Out Direct-Convert Media with Inband Closed Caption SeaChange MediaClient encodes Closed Caption (CC) data from the SDI signal's line 21 and the MediaClient decoders replace the CC data onto line 21 of the output SDI video signal. The MediaClients should be set to decode CC on line 21, not line 22. In the legacy BMC product however, materials provided by certain program providers as a file transfer (for example, PathFire or any other Pinnacle-encoded video materials) will create video files containing CC data that plays out of the SeaChange legacy Genesis decoder with SDI signals with CC on line 22. This erroneous placement of CC data on line 22 is due to a mismatch between the source system s encoder chipset and the legacy BMC decoder chipset. Customers should use FlipFactory to transcode PathFire content into SeaChange Legacy BMC Genesis content. In the case of MediaClient, SeaChange prefers customers to use transcoding to conform all the disjoint MPEG non-conforming GOPs created by the PathFire spot insertion workflow. For the MediaClient codec, you need to re-wrap the media in FlipFactory (which takes much less time; about 12 minutes per half-hour program). Transcoding takes longer time; about 60 minutes for a half-hour program. When you set up a factory to direct-convert (by re-wrapping the essence in a different file format, without decoding and re-encoding the essence) media with in-band closed captioning, the inband closed captioning is by default on line 21. When you deliver this media to a BMLe server, you must modify the BMLe server to play out the media correctly, because by default, BMLe servers read closed captioning from line 22 during playout. There are two solutions for this problem. Continue direct-converting from FlipFactory and modify BMLe registry settings to play out closed captioning on line 21 or Set up a factory to decode and re-encode your media, enabling the crop and mask filter on the output product to shift in-band closed caption on line 21 to line 22. Note: When you modify the SeaChange BMLe server s registry settings recommended below, closed captioning plays out on line 21 for all media on the BMLe. This includes any previous media which has closed captioning on line 22, causing their playout to fail. You should only modify the registry to support closed caption playout on line 21 when all of the media with closed caption content stores it on line 21. If you have media with closed captioning on line 22, you can add another node on the BMLe server, dedicated to direct-convert media from FlipFactory. Only store line-21 closed caption media on this server, and modify the registry to play out the media with line 21 for closed caption. Set up a factory to decode and re-encode media with closed captioning on line 22, using crop and mask filters. This is handled in the registry by setting this value per input and/or output port. Each port is configured separately. Playing Out Direct-Convert Media with Inband Closed Caption 2007 Telestream, Inc. Page 6

For example, for a 4012 product (2-out/1-in) you should have the following keys: HKEY_LOCAL_MACHINE\SOFTWARE\Ligos Corporation\Media Client\0\VideoStartLine - output port 1 HKEY_LOCAL_MACHINE\SOFTWARE\Ligos Corporation\Media Client\1\VideoStartLine - output port 2 HKEY_LOCAL_MACHINE\SOFTWARE\Ligos Corporation\Media Client\2\VideoStartLine - input port 1 The BMC Genesis decoder card default is 6 for NTSC and 9 for PAL. This is the first line to capture from or output to (as appropriate) if the file has 32 extra lines of video (512 for NTSC or 608 for PAL). If the file has 16 extra lines, then this value+8 would be the first output line. This variable has no effect of no extra lines are captured. Note that the encoding and decoding registry settings must be in agreement among all MediaClient encoders and decoders across the server, otherwise line offsets will occur. If a BMC with Beowulf encoding cards and Genesis decoder cards is also used in the system, the MediaClient encoder and decoder settings should be set to correspond with CC data appearing on line 21. If a BMC is in place and a MediaLibrary platform system is added to the BMC, the MediaClient settings must correspond to the BMC encoders and decoders. Playing Out Direct-Convert Media with Inband Closed Caption 2007 Telestream, Inc. Page 7

Appendix A Using EXD to Locate Files To use the EXDutil program to locate files on the SeaChange server or to determine that delivery of media from FlipFactory via FTP was successful after processing a job, use the KVM to switch to display the SeaChange BOSS computer. On the BOSS computer, locate the EXDutil icon and double-click to launch the application. Figure 2. Use EXDutil to locate files on the SeaChange server Connect to the MCL on the BMLe server. Next, select the inventory tab and click Refresh. Figure 3. On the Inventory tab, select a file from inventory Use the slider to move through the inventory to locate the file you delivered. Appendix A Using EXD to Locate Files 2007 Telestream, Inc. Page 8

Appendix B Finding the CIFS NAME You can use Seaview to locate the CIFS name of an FSI card located on the BOSS computer of the BMLe server. Use the attached KVM to switch to the BOSS computer. Double-click the Seaview Icon on the desktop to launch Seaview. Figure 4. Double-click the Seaview shortcut on the desktop to launch Seaview. Seaview connects to the BMLe server and displays this window (sample shown). Figure 5. Use Seaview to view the BMLe server. Click on the node that has the target FSI card to display the System View window: Appendix B Finding the CIFS NAME 2007 Telestream, Inc. Page 9

Figure 6. Seaview displays a system view of the node. FSI cards are indicated by diamond icons in the upper left corner of the window, numbered (left to right) as FSI0, FSI1, FSI2, and FSI3. Click the target FSI card to display the details window: Figure 7. Seaview displays a system view of the node. Identify the IP address of this FSI card top field in second group of details on left). Verify that this IP address is the same as the IP address you have noted earlier. If not, select another FSI port. Locate the CIFS card name (second field in the second group of details on the right). Note the hostname of the card with your IP address for use when configuring FlipFactory to identify the BMLe server. Appendix B Finding the CIFS NAME 2007 Telestream, Inc. Page 10

Copyright and Trademark Notice 2007 Telestream, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, altered, or translated into any languages without written permission of Telestream, Inc. Information and specifications in this document are subject to change without notice and do not represent a commitment on the part of Telestream. Telestream, FlipFactory, and ClipExpress are registered trademarks of Telestream, Inc. ClipMail, FlipFactory, FlipFactory Publish, FlipFactory Pro, TrafficManager, Telestream MAP, MAPx, MAPone, and HyperLaunch are trademarks of Telestream, Inc. SeaChange is a registered trademark of SeaChange International, Inc. MediaLibrary and MediaClient are trademarks of SeaChange International, Inc. All other brand, product, and company names are the property of their respective owners and are used only for identification purposes. Contacting Telestream For product assistance, or information about Telestream or its products, please contact us: Internet Web Site: www.telestream.net Technical Support: support@telestream.net Licensing: license@telestream.net Sales and Marketing: info@telestream.net USA Telephone Main: (530) 470-1300 or (877) 257-6245 USA Customer Support: (530) 470-1336 or (877) 681-2088 Mail Telestream, Inc. 848 Gold Flat Road-Suite 1 Nevada City, CA. USA 95959 International See our Web site for your regional authorized Telestream distributor. Contacting SeaChange Customer Service Dial 1-978-897-0100 and follow the prompts: 1 (Technical Support) > 4 (Broadcast & OEM). This connects you to SeaChange Broadcast Customer Service Department, which is staffed continually, and is based in Greenville, NH. Acknowledgement Telestream acknowledges and appreciates the contribution of SeaChange to this app note. Specifications subject to change without notice. Copyright and Trademark Notice 2007 Telestream, Inc. Page 11

April, 2007 P/N 74-0091-00 Contacting SeaChange Customer Service 2007 Telestream, Inc. Page 12