Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

Similar documents
CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Sub-trunk line Terminating Resistance Repeater Unit. Branch Line Repeater Unit. Sub-trunk line. Terminating Resistance.

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

Connecting Sockets, Mounting Brackets, DIN Rails

Features various encoder interfaces and controls multiple analog servo drives at high speeds

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

CX-One Ver.4 CSM_CX-One_DS_E_8_2

CX-One Ver.4 CSM_CX-One_DS_E_10_2

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

SYSMAC CS-series MECHATROLINK-II-compatible Position Control Units

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

S82S (3/7.5-W Models)

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

CJ1W-FLN22 CSM_CJ1W-FLN22_DS_E_3_1

Name Specifications Model Standards. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Model A7BS

CSM_PYF S/P2RF- -S_DS_E_2_5

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Solid State Relays with Failure Detection Function

Number of input channels

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Indicator (Square) Ultra Bright LED Type

Indicator (Square) Ultra Bright LED Type

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

Electroformed Probe Pins XP3A

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

NX-TS. NX-series Temperature Input Unit

CJ series Position Control Units. High-speed, High-precision positioning with 1, 2, or 4 axes. Features. System Configuration

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

Dimension A. Dimension B

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

Model Number Structure

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

E4C-UDA CSM_E4C-UDA_DS_E_12_2

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

M16-J M16-A M16-T

EtherCAT master * Output port CPU Unit

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

NJ-Series Power Supply Unit NJ-PA/PD

Practices Guide OMRON Standard IAG Library

Model NPN output PNP output Standard. configuration

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

CS1W-EIP21 CSM_CS1W-EIP21_DS_E_7_3

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

Knob-type Selector Switches

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

NX-DA CSM_NX-DA_DS_E_3_1

CJ1W-FLN22. CJ-series FL-net Unit. Connect to Multivendor Controller Networks. Features

Classification Applicable models Specification Type Model

CJ1W-ETN21 CSM_CJ1W-ETN21_DS_E_6_2

Communication Unit Dedicated for RFID V680 Allowing Direct Connection to OMRON PLC CJ/ CS/NJ-series

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Analog Input Unit. MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

NPN output. 200 mm. Type Cable length Model Remarks

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

CJ-series Position Control Units (High-Speed type) Motion Control Capabilities with Unit Synchronization and Even Higher Speed.

ID Sensor Modules CJ1W-V600C11/V600C12 CS1W-V600C11/V600C12

NYM. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

Model Number Structure

Model Number Structure

CX-One Ver.4. FA Integrated Tool Package CX-One. Greater Integration with the CX-One. Features

CPU Unit. (Temperature control) (Position control) (Speed control)

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

CJ1W-EIP21 CSM_CJ1W-EIP21_DS_E_9_2

Machine Automation Controller NJ Series

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

CSM_NX-PG0 DS_E_4_4

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

CJ1W-SPU01-V2. CJ-series High-speed Data Storage Unit (SPU Unit) High-speed Collection of System Data. Features. System Configuration

MACH No. MODE. Regulator. Servocontroller. Variable speed controller. Chart recorder

Photoelectric Sensor

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Model Number Structure

Limit Switch Connectors

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

Transcription:

CS-series Net Unit CSM DS_E_5_3 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures a high degree of simultaneity between data. Can be used as both and at the same time. Equipped with settings and monitor functions aimed at improving both design and startup efficiency. Achieve maximum performance by using in combination with a Configurator. Files of master and slave settings can be uploaded and downloaded using memory cards, allowing effective debugging and easier setup. System Configurations Net Configurator Control system Maintenance system Ethernet PLC Control information MIL Connector Terminals Maintenance information Common Functions Network power supply voltage monitor Unit/Connected device comments Unit power-on time monitor Remote I/O Terminals Models with 3-tier Terminal Blocks Remote I/O Terminals Relay Output Terminals E5ZN-DRT Net Communications Unit Remote I/O Terminals Analog I/O Terminals Environment-resistive Terminals Sensor Terminals Screw-less Clamp Terminals : Board Terminals with MIL Connectors Reduce Setup Time Reduce Downtime Improve Maintenance Network power supply monitor function Input filter function Power-ON inrush current protection function Communications speed auto-detect function Scaling function User compensation function Cumulative counter Moving average processing function Number of A/D conversion points (conversion cycle) setting Peak/bottom hold function Top/valley hold function Percentage change calculation function Unit comments function Connected device comments function I/O power supply monitor function Sensor power supply short-circuit detection function External load short-circuit detection function Disconnected sensor detection function Operation time monitor function Contact operations counter (See note.) Unit conduction time monitor function Total ON time monitor function (See note.) Network power supply voltage monitor function Communications error log function Last maintenance date Comparator function Selectable output value after error Note: The number of contact operations monitor function and the cumulative ON time monitor function cannot be used simultaneously for the same contact. 1

Communications Specifications Item Communications protocol Net Specifications Connection methods Multi-drop and T-branch connections can be combined (for trunk and branch lines) *1 Baud rate Communications media Communications distances for special 5-wire cables Communications distances for special 4-wire flat cables Communications power supply Max. number of nodes 500 Kbps, 250 Kbps, or 125 Kbps Special 5-wire cables (2 signal lines, 2 power lines, 1 shield line) Special 4-wire flat cables (2 signal lines, 2 power lines) Baud rate Network length Branch line length Total branch line length 500 kbps 100 m max. 6 m max. 39 m max. 250 kbps 250 m max. *2 6 m max. 78 m max. 125 kbps 500 m max. *2 6 m max. 156 m max. Baud rate Network length Branch line length Total branch line length 500 kbps 75 m max. 6 m max. 35 m max. 250 kbps 150 m max. 6 m max. 48 m max. 125 kbps 265 m max. 6 m max. 135 m max. 24 V DC supplied externally 64 nodes (including Masters, Slaves, and Configurator) *1. Terminators are required at both ends of trunk line. *2. Indicates the maximum network length when thick cables are used. Reduce the network length to 100 m max. when using thin cables. Network Specifications Trunk Line Length (100 m: 500,000 bps; 250 m: 250,000 bps; or 500 m: 125,000 bps) 24 V DC power supply for network Terminating resistance Multidrop Tap Tap Tap Terminating resistance Tap Star Connections T-Branch (Branch line length: 6 m max.) Tap Tap Branching to Branch Lines 2

Ordering Information International Standards The standards are abbreviated as follows: U: UL, U1: UL(Class I Division 2 Products for Hazardous Locations), C: CSA, UC: culus, UC1: culus (Class I Division 2 Products for Hazardous Locations), CU: cul, N: NK, L: Lloyd, and CE: EC Directives. Contact your OMRON representative for further details and applicable conditions for these standards. Product Appearance Specifications Number of licenses Media Model Standards Net Unit For CS Series Functions as either or. 2,048 I/O points UC1, N, L, CE CX-One FA Integrated Tool Package Ver.4.@ The CX-One is a package that integrates the Support Software for OMRON PLCs and components. CX-One runs on the following OS. OS: Windows XP (Service Pack 3 or higher, 32-bit version) / Windows Vista (32-bit/64-bit version) / Windows 7 (32-bit/64-bit version) / Windows 8 (32-bit/64-bit version) / Windows 8.1 (32-bit/64- bit version) / Windows 10 (32-bit/64-bit version) CX-One Ver.4.@ includes CX-Integrator Ver.2.@. For details, refer to the CX-One catalog (Cat. No. R134). 1 license * DVD CXONE-AL01D-V4 * Multi licenses (3, 10, 30, or 50 licenses) and DVD media without licenses are also available for the CX-One. Specifications Communications power supply voltage 11 to 25 VDC *1 Current consumption Communications: 30 ma max. Internal circuit: 290 ma max. Max. number of connectable slaves Remote I/O, explicit message service 63 *2 Fixed allocations 2,048 points 32 points Max. number of I/O points Number of allocated words User-set allocations Fixed allocations User-set allocations allocated DM Area words Configurator allocated DM Area words Configurator 16,000 points 3,200 points 32,000 points 4,800 points Max. message length 542 bytes *4 Max. number of Fixed allocations 3 Units mountable to PLC User-set allocations 16 Weight 172 g max. 64 input and 64 output words Software switch/status area: 25 words 1 input word, 1 output word *3 500 input and 500 output words Software switch/status area: 25 words 100 input and 100 output words *3 Software switch/status area: 25 words 500 input words x 2 blocks, 500 output words x 2 blocks Software switch/status area: 25 words 100 input words x 1 blocks, 100 output words x 2 blocks Software switch/status area: 25 words *1. Refer to the Net (W267) for the communications power supply specifications. *2. The Unit uses a node, and so connection is possible to 63 slaves only. *3. When the Net is used as, "input" and "output" respectively refer to input from the slave to the master and output from the master to the slave. *4. The maximum message length includes the command code when using the CMND instruction 3

498765 498765 498765 498765 External Interface DRM21 MS NS CS Indicators NODE ADR 1 2 3 4 ON UNIT No. X10 1 0 FEDCBA987654321 1 DR0 2 DR1 3 ESTP 4 HOLD X10 0 Unit No. switch This switch sets the unit number of the Net Unit as a one-digit hexadecimal value. Node address switches These switches set the node address as a two-digit decimal value. DIP switch The pins have the following functions: Pins 1 and 2: Baud rate Pin 3: Continue/Stop communications for error (when used as a Master) Pin 4: Hold/clear I/O for communications error (when used as a Slave) Communications connector Connect the Network communications cable to this connector. The communications power for this Unit is also supplied through this connector. A parallel connector with screws (XW4B-05C1-H1-D) is provided for node connection. Communications Connectors Color stickers that match communications cable colors are attached to the communications connectors. Match the colors when connecting communications cables to the connectors. These colors are given in the following table Black Color Signal Power line, negative voltage (V ) Blue Communications line, low (CAN L) Shield White Communications line, high (CAN H) Red Power line, positive voltage (V+) Dimensions (Unit: mm) 35 13.7 101 DRM21 MS CS NS UNIT No. 0FEDCBA987654321 NODE ADR X10 1 X10 0 88 130 1 2 3 4 ON 1 DR0 2 DR1 3 ESTP 4 HOLD 35 12 15 8 7 4

Related Manuals Cat. No. Manual Products Contents W380 W267 W404 W382 W348 CS/CJ-series Net Unit Net DRT2 Series Net Slaves Net Configurator Ver. 2.@ Net MULTIPLE I/O TERMINAL CS1W-DRM21(-V1) and CJ1W-DRM21 Net Units C200HW-DRM21-V1 Net Master Unit CQM1-DRT21 I/O Link Unit DRT1-series Net Slaves GT1-series Net Slaves DRT2-ID/OD/MD32SL(H)(-1) DRT2-MD16S DRT2 Series WS02-CFDC1-E Net Configurator 3G8F5-DRM21 ISA Board 3G8E2-DRM21 PCMCIA Board DRT1-COM GT1 Series Information on CS/CJ-series Net Units. Information on C200H-series, CVM1, and CVseries Net Units, as well as general Net communications specifications and wiring methods. Information on Net Slaves. Information on using the Configurator. Information on MULTIPLE I/O TERMINALs, one type of Net slave. 5

Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2016.5 In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2016 All Right Reserved.