Control IT. Features and Benefits. Overview. Harmony Area Controller

Similar documents
Control IT. Features and Benefits. Overview. Harmony Rack Input/Output

Control IT. Features and Benefits. Overview. Modular Power System III. Inputs: 120/240 VAC or 125 VDC power feeds allowing mixed AC and DC operation.

SECTION 1 - INTRODUCTION

Control IT AC 800C Controller

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

Harmony Series. Cnet-to-HCU Communication Interface INNIS21/INNPM22

Harmony Distributed Control Unit

Freelance 800F packed with new features! Coming soon

Control IT. Description. Data Sheet. Harmony Sequence of Events

Composer Configuration Toolkit Overview

Procontrol P14 Complete power plant control system

Ovation Compact Controller

Symphony Plus S+ Control: AC 870P

Previse Inc. Products & Services for Bailey DCS systems. Overview. OPsCon Operators Console For ABB/Bailey Net 90, Infi 90 & Harmony DCS

HARDWARE OF SUPERVISORY CONTROL & DATA ACQUISITION SYSTEM

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

IMMFP11. Multi-Function Processor Module. Process Control and Automation Solutions from Elsag Bailey Group

DeltaV Connect Solution for Bailey Systems

expertise beyond controls Reliant Series 5

Components of a personal computer

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

expertise beyond controls Vanguard Series 5

Symphony Plus S+ Control & I/O: MR Series (Melody Rack)

SCADA Solutions Since 1981 DATA FLOW SYSTEMS

Micro-PWC Personal Work Center PW6000

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Compact Control Builder AC 800M and S800 I/O ABB

LineGuard Specification Sheet Issued 8/24/10 VA Revision 0. Valve Automation

StrongARM** SA-110/21285 Evaluation Board

CHAPTER 3 WIRELESS MEASUREMENT INSTRUMENT

C900 PowerPC G4+ Rugged 3U CompactPCI SBC

output devices. connected to the controller. data communications link. relay systems. user program. MECH1500Quiz1ReviewVersion2 Name: Class: Date:

Automation systems. Scalable performance for every requirement

Control IT S800 I/O System

DeltaV Connect Solution for Bailey Systems

DataFlow. DataFlow. Electronics & Software. Quality Monitoring System. DataFlow Statistics. Type 2805A...

GE Intelligent Platforms PAC8000 RTU

DeltaV SIS TM. Logic Solver. DeltaV SIS Logic Solver. Introduction. DeltaV SIS Product Data Sheet. World s first smart SIS Logic Solver

The PowerEdge 6450 systems offer the following major features:

Computer-System Organization (cont.)

POINT I/O Family. Chapter. Overview

How Redundant Power Supplies Prevent System Downtime

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

SIMATIC. Process Control System PCS 7 V7.0 SP1 Software Update With Utilization of New Functions (PCS 7 V6.x to V7.0 SP1) Preface.

ALS c en Alspa CE80 20 N80 Bus Interface Unit User s Manual

C901 PowerPC MPC7448 3U CompactPCI SBC

DeltaV Event Chronicle

Making the decision to switch from PLC to PC-based Control has gotten even easier with the introduction of MachineLogic Control Software.

PROGRAMMING OF CONTROL SYSTEMS FOR INDUSTRIAL PROCESSES

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

SCADA Solutions for Water and Wastewater Treatment Plants

M-series MQ Controller

EN60849/IEC60849 compliant

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Overview of Microcontroller and Embedded Systems

Series Specialty PLCs

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

(Cat. Nos L11B, -L20B, -L30B, -L40B, -L40L, -L60B, -L60L, -L80B. System Overview

Industrial IT System 800xA Operations. Reducing time to decision and action. Overview. Features and Benefits

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

Interface Adapter Card. Part Number

IDM DATA ACQUISITION SYSTEM

CONTROLLERS. ISA DATA SHEET page 1/4. Description

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

Classic PLC 5 Programmable Controllers (1785 LT, 1785 LT2, 1785 LT3, 1785 LT4) Product Data

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

BS2000/OSD Business Server S210

Technical Summary MA00358A

PXC Modular Series. Features. Description. Technical Specification Sheet Document No Rev. 1.1, May 2007

Inside the Computer System

KS 108 easy Compact automation unit for industrial control and process technology

POINT I/O Family. Chapter. Overview

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

KS 108 easy Compact automation unit for industrial control and process technology

DeltaV MX Controller. Introduction. Benefits. Right-sized controllers. Easy to use. Has the flexibility to meet your needs

The industry standard for sequential events recording Proven, reliable and easy to use

Control strategies for web handling

MODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives

Allen-Bradley. User Manual. PLC-5 Backup Communication Module (1785-BCM, 1785-BEM) product icon

Universal Control Platform for Pneumatic Valves Facilitates System-wide Compatibility

Programmable Logic Controller Gateway Specification and Technical Data

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

IBM System x3850 M2 servers feature hypervisor capability

S-Band Redundant LNA Systems

Compact 800 Our control applications are simple and effective

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

SIMATIC. Process Control PCS 7 V7.0 PCS 7 OS Process Control. Preface, Contents. Additional Documentation 1 Functions of the PCS 7 OS in Process Mode

Standard PACSystems 18-slot Wall (Rear) Mount. 15 Single Width, 8 Double Width (plus one for power supply) RX7i CPU and I/O, VME modules


Platform. Product Data Sheet PDS A01 January, 2004 NGA 2000

PROFI LINE MODULAR. Top Performance in Smallest Spaces

ST (6ES7132-6FD00-0BB1)

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Contents. Chapter 1 Introduction to the CP-20. CP-20 Control Panel Technical Support Chapter 2 Executing Switches

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

Catalyst. Your all-in-one data logging and remote monitoring solution

System 800xA 800xA for Freelance Product Guide

M-series MX Controller

Operator system. Safe and convenient process control with the SIMATIC PCS 7 operator system

Transcription:

Overview Control IT Harmony Area Controller Features and Benefits de Integrated controller: Consolidates area management and control and network communications into one user-replaceable unit, reducing implementation costs. Downloadable firmware: Downloaded via the network to take advantage of future system enhancements, thereby reducing life cycle costs. Open design: PCI card slots provide open system connectivity to industry standard communication networks and protocols. Multiple systems support: Supports both the Symphony Harmony blocks as well as Harmony rack modules. Compatible with existing configurations: Execution environment is compatible with existing INFI 90 OPEN function codes and language configurations. Improved on-line configuration: New strategy allows function blocks to be added or deleted anywhere within a control segment without interrupting the process. Redundancy: Provides exceptionally high availability and fault tolerance when configured as a redundant pair. Local interface: LCD display indicates module type, displays menus, and provides operational feedback. Serial communications channels: Two independent general purpose serial channels are available to interface third-party devices. TC00312B The Harmony Area Controller is an area management and control node for the Symphony Enterprise Management and Control System. The controller communicates with other system nodes over Control Network (Cnet). It collects process, performs control algorithms, and outputs control signals to process level devices. The controller also imports and exports process data from and to other system nodes, and accepts operator control commands through network connected workstations. The controller communicates with both Harmony blocks and Harmony rack modules to meet the input and output requirements of virtually any process. Each controller can handle thousands of analog and digital points with functions such as multiloop, analog, sequential, batch, and advanced controls. It has advanced data acquisition features such as trending, variable alarming, alarm inhibiting, and sequence of events. On-board, user-addressable control algorithms (i.e., function codes) enhance processing power and support even the most complex process management and control strategies. A standard library of function codes ranges from simple AND and NOT logic functions to complex Smith Predictor and Linear Regression functions, with no advanced programming knowledge required to apply these powerful capabilities. Programming and control language support includes C, Batch 90, and UDF (user-defined function).

Additional Features Flexible configuration: The controller is scalable for a variety of applications from complex control strategies to data acquisition to advanced information processing. It supports multiple programming and control languages including C, Batch 90, and UDF. Enhanced communications: State-of-the-art hardware and new internal architecture increases process data import and export rates. Modular packaging: One user-replaceable unit reduces installation costs. Block packaging combines an enclosure mounting panel, a docking station for module interconnection, controller assemblies, and termination assembly. Improved operator interface: A front panel keypad in conjunction with the LCD screen assist in selecting mode changes and setup options. Station link: A station link to communicate with Analog Control Stations (IISAC01). Description The Harmony area controller is an integrated package that combines control, communication, and power supply functions into one user-replaceable module. The controller consists of a controller module mounted on a docking station with termination units (Fig. 1). The controller module contains internal printed circuit boards: CPU board, process board, and network board. The backplane for these boards is a high-speed, industry-standard PCI data bus. The docking station provides system power and termination unit connections to the various communication networks, e.g., Cnet network, Harmony Network (Hnet), peer-to-peer, and expander bus (Fig. 2). If redundancy is desired, simply mount another identical module on the docking station, which is engineered to implement the automatic backup feature. The CPU board contains the central processing unit (CPU) for the controller module. It incorporates a 32-bit microprocessor running at 50 megahertz. The resident operating system is a multitasking, interrupt driven, real-time operating system. The memory system consisting of flash-rom memory, DRAM memory, and NVRAM memory has built-in automatic error detection and correction features that further bolster system reliability and availability. Furthermore, both firmware and configurations are downloadable via the Cnet network minimizing overall life-cycle support costs. The process board provides the links to process, two serial ports, and discrete operator control stations. Direct process is connected to the controller via the Hnet network for blocks and/or the expander bus for rack modules. This board also contains the highspeed data transfer link between redundant controller modules to yield exceptionally high system availability. The network board handles the communication on the Cnet network. This control network is a high speed, high throughput serial data highway implemented in all Harmony control units. Up to 250 nodes can be supported in a central network with satellite networks linked to the central network through local and remote interfaces. The Harmony area controller can be added to existing INFI 90 OPEN INFI-NET communications networks. The docking station provides termination and distribution of signals, and the means to mount the controller modules. It contains a printed circuit board backplane, and the physical communication 2 WBPEEUS230001B2

TERMINATION S REDUNDANT DOCKING STATION T02633A Figure 1. Harmony Area Controller Operation pathways and the power distribution signal lines between the controller modules and the termination units. External cable connections attach at the termination units and other docking station connectors. Backplane circuitry stores the controller setup information including its loop and node addresses, loop mode, licenses, and setup options. This allows replacing a controller module and having the replacement module automatically retrieve and update its setup and license information. The Harmony area controller, in conjunction with the associated docking station and termination units, represents one area management and control node in the Symphony system. The controller receives process input and sends output signals via a variety of devices including the Harmony blocks and Harmony rack modules. Additionally, data can be exchanged with other nodes via the Cnet network. An extensive library of function codes and C, Batch 90, and UDF language support gives the tools needed to design complex control strategies to fit any control application. Each Harmony area controller is scalable from small to large function block capacity. Nonvolatility is provided for both the control algorithms and the user-defined configurations. The control algorithms are resident in flash memories which render them impervious to power losses. Furthermore, future enhancements can be downloaded via the communication network without having to perform physical modifications to each controller such as replacing ROMs or swapping modules, thus reducing life cycle cost of ownership. WBPEEUS230001B2 3

CONDUCTOR HUMAN SYSTEM INTERFACE COMPOSER PLATFORM PERFORMER PLATFORM ONET NETWORK COMMUNICATIONS COUPLER CNET RS-485/RS-232-C PEER-TO-PEER LINK HNET EXPANDER BUS CONTROL CONTROL RACK APPLICATIONS PLATFORM BLOCKS T02968A Figure 2. Harmony Communications Architecture A liquid crystal display (LCD) is standard on the front panel of the Harmony area controller. This LCD provides a local operator interface for information such as module type, status, and setup options in easily comprehensible text. Along with the keypad on the front panel, the LCD screen serves as a menu display for those functions available locally such as node or module address, setup options, and status inquiries. The high-speed redundancy communication link between a pair of controllers provides the means for automatic one-for-one backup thus ensuring high system availability. If the primary controller should fail, the secondary is waiting in standby with the same control strategy and current process data, and immediately assumes control. Diagnostic routines are constantly checking the integrity of the hardware and firmware. The memory subsystem in the Harmony area controller is designed with automatic error detection and correction circuitry, making it extremely fault tolerant and secure for control applications. 4 WBPEEUS230001B2

Control Network The controller is a node on the Cnet network. Cnet is a unidirectional, high speed serial data network that operates at a 10-megahertz communication rate. It supports a central network with up to 250 system node connections. Multiple satellite Cnet networks can link to the central network. Each satellite network supports up to 250 system node connections. Interfacing a maximum number of satellite networks gives a system capacity of 62,500 nodes. A node can be a satellite network, a Harmony control unit consisting of a Harmony area controller with its devices, and a Harmony network communications coupler connecting human system interfaces and computers operating on the Operations Network (Onet). The Harmony area controller uses Cnet network for such things as to: Communicate field input values and states for process monitoring and control. Communicate configuration parameters that determine the operation of functions such as alarming, trending, and logging on a human system interface. Process field input data acquisition. Receive control instructions from a human system interface to adjust process field outputs. Provide feedback to plant personnel of actual output changes. Data is transferred in messages that contain system data, control, and configuration information and also in exception reports. Exception reported data appears as dynamic values, alarms, and state changes on displays and in reports generated by human system interfaces and other system nodes. Exception reporting for the controller is automatic. The controller generates an exception report periodically to update data, after a process point reaches a defined alarm limit or changes state, or after a significant change in value occurs. Interface Figures 3 and 4 show the Harmony area controller interfacing to Harmony blocks and Harmony rack modules. blocks and rack modules can operate in parallel with a single controller. The Harmony system incorporates a variety of input and output devices (i.e., blocks) to interface process signals to the Harmony area controller. The controller communicates with blocks over Hnet. Block types include analog, digital, and control. Additionally, the Harmony system supports remote communication through Hnet repeaters mounted in repeater mounting units. The Harmony rack system utilizes a wide variety of input, output, and signal conditioning modules to interface process signals to the Harmony area controller. The controller communicates with rack modules over expander bus. Rack module types range from standard analog and digital to specialty such as turbine control, field bus, and sequence of events. Peer-to-Peer Communication Figure 5 shows peer-to-peer Harmony area controller communication. Peer-to-peer communication is intended as a direct means for transferring point data between controllers instead of transferring the data over Cnet network. It is only intended for transferring a small number of WBPEEUS230001B2 5

CNET REMOTE LOCATION HNET HNET BLOCKS HNET BLOCKS REPEATER MOUNTING REPEATER MOUNTING FIELD WIRING ANALOG CONTROL STATIONS PROCESS PROCESS T02626A Figure 3. Harmony Area Controller with Harmony Blocks CNET EXPANDER BUS TERMINATION CABLE RACK RACK RACK TERM INATION S TERM INATION S TERMINATIO N S FIELD WIRING FIELD BUS PROCESS ANALOG CONTROL STATIONS PROCESS T02625A Figure 4. Harmony Area Controller with Harmony Rack 6 WBPEEUS230001B2

points (50) at a fast rate of approximately 500 points per second. All controllers that communicate over the peer-to-peer link reside on the same local Cnet network. CNET PEER-TO-PEER LINK HNET REPEATER MOUNTING LOCATION 1 PEER-TO-PEER LINK REPEATER MOUNTING LOCATION 2 T02969A Figure 5. Harmony Area Controller Peer-to-Peer Communication Compatibility The Harmony area controller is compatible with existing INFI 90 OPEN systems. The controller can easily be integrated into established installations that currently use INFI-NET communication networks. Communication with INFI 90 OPEN modules is over expander bus (Fig. 4). Function block configurations in existing INFI 90 OPEN control modules can be downloaded to the Harmony area controller with only minor modifications. Configuration Tools The Harmony area controller can be configured and tuned using any Symphony configuration tool that supports editing function blocks and modifying function code specifications. This includes, for example: Composer (2.0 and later). Conductor NT (2.3 and later). Conductor VMS (2.0 and later). Using the Composer tools is the recommended method for creating and managing controller configurations. Software Licenses The Harmony area controller utilizes software licensing to manage its major available features. A software key is necessary for proper operation of specific functions. This key is written to and stored in the docking station during initial controller setup. The key permits a feature licensed for the particular controller to be executed. The license key can be expanded after initial setup, but a WBPEEUS230001B2 7

feature once enabled cannot be removed. The following functions are under license management control: Number of function blocks (4,000, 10,000, or 20,000). C language support. Batch 90 and UDF language support. Symphony, Batch 90, Control IT, and Composer are trademarks of ABB. INFI 90 and INFI-NET are registered trademarks of ABB. For more information on the Control IT suite of products, contact us at ControlIT@us.abb.com For the latest information on ABB visit us on the World Wide Web at http://www.abb.com/control

Overview Control IT Harmony Area Controller Features and Benefits de Integrated controller: Consolidates area management and control and network communications into one user-replaceable unit, reducing implementation costs. Downloadable firmware: Downloaded via the network to take advantage of future system enhancements, thereby reducing life cycle costs. Open design: PCI card slots provide open system connectivity to industry standard communication networks and protocols. Multiple systems support: Supports both the Symphony Harmony blocks as well as Harmony rack modules. Compatible with existing configurations: Execution environment is compatible with existing INFI 90 OPEN function codes and language configurations. Improved on-line configuration: New strategy allows function blocks to be added or deleted anywhere within a control segment without interrupting the process. Redundancy: Provides exceptionally high availability and fault tolerance when configured as a redundant pair. Local interface: LCD display indicates module type, displays menus, and provides operational feedback. Serial communications channels: Two independent general purpose serial channels are available to interface third-party devices. TC00312B The Harmony Area Controller is an area management and control node for the Symphony Enterprise Management and Control System. The controller communicates with other system nodes over Control Network (Cnet). It collects process, performs control algorithms, and outputs control signals to process level devices. The controller also imports and exports process data from and to other system nodes, and accepts operator control commands through network connected workstations. The controller communicates with both Harmony blocks and Harmony rack modules to meet the input and output requirements of virtually any process. Each controller can handle thousands of analog and digital points with functions such as multiloop, analog, sequential, batch, and advanced controls. It has advanced data acquisition features such as trending, variable alarming, alarm inhibiting, and sequence of events. On-board, user-addressable control algorithms (i.e., function codes) enhance processing power and support even the most complex process management and control strategies. A standard library of function codes ranges from simple AND and NOT logic functions to complex Smith Predictor and Linear Regression functions, with no advanced programming knowledge required to apply these powerful capabilities. Programming and control language support includes C, Batch 90, and UDF (user-defined function).

Additional Features Flexible configuration: The controller is scalable for a variety of applications from complex control strategies to data acquisition to advanced information processing. It supports multiple programming and control languages including C, Batch 90, and UDF. Enhanced communications: State-of-the-art hardware and new internal architecture increases process data import and export rates. Modular packaging: One user-replaceable unit reduces installation costs. Block packaging combines an enclosure mounting panel, a docking station for module interconnection, controller assemblies, and termination assembly. Improved operator interface: A front panel keypad in conjunction with the LCD screen assist in selecting mode changes and setup options. Station link: A station link to communicate with Analog Control Stations (IISAC01). Description The Harmony area controller is an integrated package that combines control, communication, and power supply functions into one user-replaceable module. The controller consists of a controller module mounted on a docking station with termination units (Fig. 1). The controller module contains internal printed circuit boards: CPU board, process board, and network board. The backplane for these boards is a high-speed, industry-standard PCI data bus. The docking station provides system power and termination unit connections to the various communication networks, e.g., Cnet network, Harmony Network (Hnet), peer-to-peer, and expander bus (Fig. 2). If redundancy is desired, simply mount another identical module on the docking station, which is engineered to implement the automatic backup feature. The CPU board contains the central processing unit (CPU) for the controller module. It incorporates a 32-bit microprocessor running at 50 megahertz. The resident operating system is a multitasking, interrupt driven, real-time operating system. The memory system consisting of flash-rom memory, DRAM memory, and NVRAM memory has built-in automatic error detection and correction features that further bolster system reliability and availability. Furthermore, both firmware and configurations are downloadable via the Cnet network minimizing overall life-cycle support costs. The process board provides the links to process, two serial ports, and discrete operator control stations. Direct process is connected to the controller via the Hnet network for blocks and/or the expander bus for rack modules. This board also contains the highspeed data transfer link between redundant controller modules to yield exceptionally high system availability. The network board handles the communication on the Cnet network. This control network is a high speed, high throughput serial data highway implemented in all Harmony control units. Up to 250 nodes can be supported in a central network with satellite networks linked to the central network through local and remote interfaces. The Harmony area controller can be added to existing INFI 90 OPEN INFI-NET communications networks. The docking station provides termination and distribution of signals, and the means to mount the controller modules. It contains a printed circuit board backplane, and the physical communication 2 WBPEEUS230001B2

TERMINATION S REDUNDANT DOCKING STATION T02633A Figure 1. Harmony Area Controller Operation pathways and the power distribution signal lines between the controller modules and the termination units. External cable connections attach at the termination units and other docking station connectors. Backplane circuitry stores the controller setup information including its loop and node addresses, loop mode, licenses, and setup options. This allows replacing a controller module and having the replacement module automatically retrieve and update its setup and license information. The Harmony area controller, in conjunction with the associated docking station and termination units, represents one area management and control node in the Symphony system. The controller receives process input and sends output signals via a variety of devices including the Harmony blocks and Harmony rack modules. Additionally, data can be exchanged with other nodes via the Cnet network. An extensive library of function codes and C, Batch 90, and UDF language support gives the tools needed to design complex control strategies to fit any control application. Each Harmony area controller is scalable from small to large function block capacity. Nonvolatility is provided for both the control algorithms and the user-defined configurations. The control algorithms are resident in flash memories which render them impervious to power losses. Furthermore, future enhancements can be downloaded via the communication network without having to perform physical modifications to each controller such as replacing ROMs or swapping modules, thus reducing life cycle cost of ownership. WBPEEUS230001B2 3

CONDUCTOR HUMAN SYSTEM INTERFACE COMPOSER PLATFORM PERFORMER PLATFORM ONET NETWORK COMMUNICATIONS COUPLER CNET RS-485/RS-232-C PEER-TO-PEER LINK HNET EXPANDER BUS CONTROL CONTROL RACK APPLICATIONS PLATFORM BLOCKS T02968A Figure 2. Harmony Communications Architecture A liquid crystal display (LCD) is standard on the front panel of the Harmony area controller. This LCD provides a local operator interface for information such as module type, status, and setup options in easily comprehensible text. Along with the keypad on the front panel, the LCD screen serves as a menu display for those functions available locally such as node or module address, setup options, and status inquiries. The high-speed redundancy communication link between a pair of controllers provides the means for automatic one-for-one backup thus ensuring high system availability. If the primary controller should fail, the secondary is waiting in standby with the same control strategy and current process data, and immediately assumes control. Diagnostic routines are constantly checking the integrity of the hardware and firmware. The memory subsystem in the Harmony area controller is designed with automatic error detection and correction circuitry, making it extremely fault tolerant and secure for control applications. 4 WBPEEUS230001B2

Control Network The controller is a node on the Cnet network. Cnet is a unidirectional, high speed serial data network that operates at a 10-megahertz communication rate. It supports a central network with up to 250 system node connections. Multiple satellite Cnet networks can link to the central network. Each satellite network supports up to 250 system node connections. Interfacing a maximum number of satellite networks gives a system capacity of 62,500 nodes. A node can be a satellite network, a Harmony control unit consisting of a Harmony area controller with its devices, and a Harmony network communications coupler connecting human system interfaces and computers operating on the Operations Network (Onet). The Harmony area controller uses Cnet network for such things as to: Communicate field input values and states for process monitoring and control. Communicate configuration parameters that determine the operation of functions such as alarming, trending, and logging on a human system interface. Process field input data acquisition. Receive control instructions from a human system interface to adjust process field outputs. Provide feedback to plant personnel of actual output changes. Data is transferred in messages that contain system data, control, and configuration information and also in exception reports. Exception reported data appears as dynamic values, alarms, and state changes on displays and in reports generated by human system interfaces and other system nodes. Exception reporting for the controller is automatic. The controller generates an exception report periodically to update data, after a process point reaches a defined alarm limit or changes state, or after a significant change in value occurs. Interface Figures 3 and 4 show the Harmony area controller interfacing to Harmony blocks and Harmony rack modules. blocks and rack modules can operate in parallel with a single controller. The Harmony system incorporates a variety of input and output devices (i.e., blocks) to interface process signals to the Harmony area controller. The controller communicates with blocks over Hnet. Block types include analog, digital, and control. Additionally, the Harmony system supports remote communication through Hnet repeaters mounted in repeater mounting units. The Harmony rack system utilizes a wide variety of input, output, and signal conditioning modules to interface process signals to the Harmony area controller. The controller communicates with rack modules over expander bus. Rack module types range from standard analog and digital to specialty such as turbine control, field bus, and sequence of events. Peer-to-Peer Communication Figure 5 shows peer-to-peer Harmony area controller communication. Peer-to-peer communication is intended as a direct means for transferring point data between controllers instead of transferring the data over Cnet network. It is only intended for transferring a small number of WBPEEUS230001B2 5

CNET REMOTE LOCATION HNET HNET BLOCKS HNET BLOCKS REPEATER MOUNTING REPEATER MOUNTING FIELD WIRING ANALOG CONTROL STATIONS PROCESS PROCESS T02626A Figure 3. Harmony Area Controller with Harmony Blocks CNET EXPANDER BUS TERMINATION CABLE RACK RACK RACK TERM INATION S TERM INATION S TERMINATIO N S FIELD WIRING FIELD BUS PROCESS ANALOG CONTROL STATIONS PROCESS T02625A Figure 4. Harmony Area Controller with Harmony Rack 6 WBPEEUS230001B2

points (50) at a fast rate of approximately 500 points per second. All controllers that communicate over the peer-to-peer link reside on the same local Cnet network. CNET PEER-TO-PEER LINK HNET REPEATER MOUNTING LOCATION 1 PEER-TO-PEER LINK REPEATER MOUNTING LOCATION 2 T02969A Figure 5. Harmony Area Controller Peer-to-Peer Communication Compatibility The Harmony area controller is compatible with existing INFI 90 OPEN systems. The controller can easily be integrated into established installations that currently use INFI-NET communication networks. Communication with INFI 90 OPEN modules is over expander bus (Fig. 4). Function block configurations in existing INFI 90 OPEN control modules can be downloaded to the Harmony area controller with only minor modifications. Configuration Tools The Harmony area controller can be configured and tuned using any Symphony configuration tool that supports editing function blocks and modifying function code specifications. This includes, for example: Composer (2.0 and later). Conductor NT (2.3 and later). Conductor VMS (2.0 and later). Using the Composer tools is the recommended method for creating and managing controller configurations. Software Licenses The Harmony area controller utilizes software licensing to manage its major available features. A software key is necessary for proper operation of specific functions. This key is written to and stored in the docking station during initial controller setup. The key permits a feature licensed for the particular controller to be executed. The license key can be expanded after initial setup, but a WBPEEUS230001B2 7

feature once enabled cannot be removed. The following functions are under license management control: Number of function blocks (4,000, 10,000, or 20,000). C language support. Batch 90 and UDF language support. Symphony, Batch 90, Control IT, and Composer are trademarks of ABB. INFI 90 and INFI-NET are registered trademarks of ABB. For more information on the Control IT suite of products, contact us at ControlIT@us.abb.com For the latest information on ABB visit us on the World Wide Web at http://www.abb.com/control

For additional information, visit us on the Internet at www.abb.com/controlsystems WBPEEUS230001B2 ABB Inc. 29801 Euclid Avenue Wickliffe, Ohio 44092 Phone: +1 440 585-8500 Fax: +1 440 585 8756 www.abb.com/controlsystems ABB AB SE-721 59 Västeras, Sweden Phone: +46 (0) 21 34 2000 Fax: +46 (0) 21 13 78 45 www.abb.com/controlsystems ABB GmbH Dudenstraße 44-46, D-68167 Mannheim, Germany Phone: +49 (0) 1805 266 776 Fax: +49 (0) 1805 776 329 www.abb.com/controlsystems Copyright 2003 by ABB Inc. All rights to trademarks reside with their respective owners. Specifications subject to change without notice. Pictures, schematics and other graphics contained herein are published for illustration purposes only and do not represent product configurations or functionality. User documentation accompanying the product is the exclusive source for functionality descriptions.