Surge Protection Devices Ex9UE2

Similar documents
MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

ETITEC - Lightning and Surge Arresters

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

Overvoltage Protection Devices

Autoprotected Surge Arresters New OVR Plus range

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

Surge Protection Devices Type 1+2

Overvoltage Protection Devices

Overvoltage Protection Devices

SPD Catalogue. SPD Catalogue. for AC applications

Overvoltage Protection Devices

Surge Protection Devices and Surge Protection Kit

PRF1 12.5r/PRF1 Master/ PRD1 25r/PRD1 Master Type 1 and 2 LV surge arresters

Overvoltage Protection Devices

Lightning and Surge Arresters

Surge protection for frequency converters

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

R3&A Limited, Cobourg, ON

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

VAL-CP-1S-175. Extract from the online catalog. Order No.:

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

PT 3-PB-ST. Extract from the online catalog. Order No.:

NEW surge protective devices

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

Surge protection for gutter heating systems

PV protective solutions

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

SPM Series Plug-in Surge Protection

US Catalog March Surge protective devices (SPDs) UL range

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

Lightning & Surge Protection for Wind Turbine Systems

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

SPM Series. Plug-in Surge Protection

Modular surge protective devices (SPDs)

MCF lightning arrestor

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

Modular surge protective devices (SPDs) Cat. Nos :

VAL-CP-3S-350. Extract from the online catalog. Order No.:

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

Surge Protection for Low Voltage Power Systems

Modular surge protective devices (SPDs)

Surge & Filter Protection Addressing your industrial power quality needs.

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Type of surge arrester

QUINT-PS AC/24DC/10

Installation / Control Technique

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

ic60n RCBO 30 ma IEC , IEC , AS/NZS

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

ABL8MEM12020 regulated SMPS - 1 or 2-phase V AC - 12 V - 2 A

Lightning and surge protection for electromobility

QUINT-PS/ 1AC/24DC/ 5

Surge protection for LED mast lights

QUINT-PS/24DC/48DC/ 5

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

Page 14-4 Page Page 14-4 SURGE PROTECTION DEVICES TYPE 2 VERSIONS WITH PLUG-IN CARTRIDGE 1P, 1P+N, 2P, 3P, 3P+N, 4P

Section 4 Ground-Fault Protection Devices

Surge Protective Device

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

Residual Current Devices FRCdM Type B, B+ and Bfq Digital

Residual Current Devices. Residual Current Devices FRCmM-NA according to UL1053 & IEC/EN 61008

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

MODULES FOR SAFETY AND MONITORING

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Building Surge Protection Information Pack

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

Lightning Current Equipotential Bonding SPDs

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

Combined RCD/MCB Devices FRBmM, 1+N-pole

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

Datasheet Stock No: RS Pro

PHOENIX CONTACT - 01/2007

2 Principle of lightning protection

SURGE PROTECTOR. lighting. for.

Surge Protective Devices. STV25K Series. Instruction Manual

02/11/2015

Lightning and Surge Arresters

Attachment plug with surge protection for coaxial signal interfaces. Connection: N connector, male/female

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Transcription:

Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0, 1+1, 2+0, 3+0, 3+1 and 4+0 connection Plug-in module design With and without remote indication contact Device status indicator The Ex9UE2 line is a group of Class II Surge Protective Devices. They are intended as a protection against transient overvoltage caused by fast switching operations or indirect hits of lightning strokes (residuum effects). It is recommended to install Class II SPDs every 10 20 meters of cable length repetitively, typically to main and sub distribution boards. The Ex9UE2 20 440 are designed for direct coordination with Class I SPDs of line Ex9UE1 35. In case of Ex9UE2 20 275, the coordination with the line Ex9UE1 35 is done by means of 10 m cable length. The design of Ex9UE2 is based on Metal Oxide Varistors. Such design provides very low response time. The modular design with plug in inserts allows simple and quick replacement of function modules in case of MOV is beyond if its lifespan due to often occurrence of overvoltage peaks. Type Key Ex9 UE 1+2 12.5 R 1P 275 Product family Product Class Current Signaling contact Type of connection Max. oper. voltage Plug-in module Ex9 UE: AC Surge Protective Devices 2: type 2 class II C T2 I n (8/20 µs) 20 ka (L-N) 40 ka (N-PE) R: Yes _: No 1P: 1+0 2P: 2+0 3P: 3+0 4P: 4+0 1PN: 1+1 3PN: 3+1 NPE: 0+1 275 V AC 320 V AC 385 V AC 440 V AC _: NPE _: Complete device M: Plug-in module only Certification marks 1

Surge Protection Devices Ex9UE2 Type 2 SPD (Class II, T2, C) complete devices, I n Nominal discharge current I n 20 ka (8/20 µs) per module and 40 ka (8/20 µs) for NPE (+1) module Maximum discharge current I max 40 ka (8/20 µs) Maximum continuous operational voltage U c 275 V AC up to 440 V AC per module and 255 V AC for NPE (+1) module Coordination with class I SPDs: Ex9UE2 20 x x 440 direct coordination Ex9UE2 20 x x 275 coordination with cable of minimum length of 10 m in between Ex9UE1 35 and Ex9UE2 20 x x 275 Max. oper. Connection Signaling Article No. Type Packing voltage U c contact 275 V AC 1+0 no 103347 Ex9UE2 20 1P 275 1/96 275 V AC 1+0 yes 103348 Ex9UE2 20R 1P 275 1/96 275 V AC 1+1 no 103349 Ex9UE2 20 1PN 275 1/60 275 V AC 1+1 yes 103350 Ex9UE2 20R 1PN 275 1/60 275 V AC 2+0 no 103351 Ex9UE2 20 2P 275 1/60 275 V AC 2+0 yes 103352 Ex9UE2 20R 2P 275 1/60 275 V AC 3+0 no 103353 Ex9UE2 20 3P 275 1/54 275 V AC 3+0 yes 103354 Ex9UE2 20R 3P 275 1/54 275 V AC 3+1 no 103355 Ex9UE2 20 3PN 275 1/45 275 V AC 3+1 yes 103356 Ex9UE2 20R 3PN 275 1/45 275 V AC 4+0 no 103357 Ex9UE2 20 4P 275 1/45 275 V AC 4+0 yes 103358 Ex9UE2 20R 4P 275 1/45 320 V AC 1+0 no 103754 Ex9UE2 20 1P 320 1/96 320 V AC 1+0 yes 103755 Ex9UE2 20R 1P 320 1/96 320 V AC 1+1 no 103756 Ex9UE2 20 1PN 320 1/60 320 V AC 1+1 yes 103757 Ex9UE2 20R 1PN 320 1/60 320 V AC 2+0 no 103758 Ex9UE2 20 2P 320 1/60 320 V AC 2+0 yes 103759 Ex9UE2 20R 2P 320 1/60 320 V AC 3+0 no 103760 Ex9UE2 20 3P 320 1/54 320 V AC 3+0 yes 103761 Ex9UE2 20R 3P 320 1/54 320 V AC 3+1 no 103762 Ex9UE2 20 3PN 320 1/45 320 V AC 3+1 yes 103763 Ex9UE2 20R 3PN 320 1/45 320 V AC 4+0 no 103764 Ex9UE2 20 4P 320 1/45 320 V AC 4+0 yes 103765 Ex9UE2 20R 4P 320 1/45 385 V AC 1+0 no 103766 Ex9UE2 20 1P 385 1/96 385 V AC 1+0 yes 103767 Ex9UE2 20R 1P 385 1/96 385 V AC 1+1 no 103768 Ex9UE2 20 1PN 385 1/60 385 V AC 1+1 yes 103769 Ex9UE2 20R 1PN 385 1/60 385 V AC 2+0 no 103770 Ex9UE2 20 2P 385 1/60 385 V AC 2+0 yes 103771 Ex9UE2 20R 2P 385 1/60 385 V AC 3+0 no 103772 Ex9UE2 20 3P 385 1/54 385 V AC 3+0 yes 103773 Ex9UE2 20R 3P 385 1/54 385 V AC 3+1 no 103774 Ex9UE2 20 3PN 385 1/45 385 V AC 3+1 yes 103775 Ex9UE2 20R 3PN 385 1/45 385 V AC 4+0 no 103776 Ex9UE2 20 4P 385 1/45 385 V AC 4+0 yes 103777 Ex9UE2 20R 4P 385 1/45 440 V AC 1+0 no 103359 Ex9UE2 20 1P 440 1/96 440 V AC 1+0 yes 103360 Ex9UE2 20R 1P 440 1/96 440 V AC 1+1 no 103361 Ex9UE2 20 1PN 440 1/60 440 V AC 1+1 yes 103362 Ex9UE2 20R 1PN 440 1/60 440 V AC 2+0 no 103363 Ex9UE2 20 2P 440 1/60 440 V AC 2+0 yes 103364 Ex9UE2 20R 2P 440 1/60 440 V AC 3+0 no 103365 Ex9UE2 20 3P 440 1/54 440 V AC 3+0 yes 103366 Ex9UE2 20R 3P 440 1/54 440 V AC 3+1 no 103367 Ex9UE2 20 3PN 440 1/45 440 V AC 3+1 yes 103368 Ex9UE2 20R 3PN 440 1/45 440 V AC 4+0 no 103369 Ex9UE2 20 4P 440 1/45 440 V AC 4+0 yes 103370 Ex9UE2 20R 4P 440 1/45 2

Surge Protection Devices Ex9UE2 Type 2 SPD spare modules, I n Max. oper. Nominal Article No. Type voltage U c current I n 275 V AC 20 ka 103344 Ex9UE2 20 1P 275 M 320 V AC 20 ka 103752 Ex9UE2 20 1P 320 M 385 V AC 20 ka 103753 Ex9UE2 20 1P 385 M 440 V AC 20 ka 103345 Ex9UE2 20 1P 440 M N-PE 40 ka 103346 Ex9UE2 40 NPE M 3

Technical Data Ex9UE2 Surge Protection Devices Type 2, I n General parameters Suitable for protection of electrical installations against transient overvoltage Plug-in module design Indication window helps users to know the status of device Optional remote-signaling contact Electrical parameters 1+0, 2+0, 3+0, 4+0, 1+1, 3+1 (L-N/PE/PEN connection) Tested according to EN 61643-11 1+1, 3+1 (x+1 N-PE connection) Classified type (test class) Type 2 (Class II, C, T2) Technology MOV (Varistor) GDT (Spark-gap) Rated operational voltage U n 230 / 400 V AC Reference test voltage U REF 255 V AC Max. continuous operational voltage U c 275 V AC 320 V AC 385 V AC 440 V AC 255 V AC Nominal frequency f 50/60 Hz Nominal discharge current I n (8/20 µs) 20 ka per pole 40 ka per pole Max. impulse current I imp (10/350 µs) - 12 ka per pole Max discharge current I max (8/20 µs) 40 ka per pole Protection voltage U p at I n 1.4 kv 1.6 kv 1.9 kv 2.2 kv 1.5 kv Protection voltage U p at I max 2 kv 2.3 kv 2.5 kv 2.8 kv 1.5 kv Protection voltage U p at 5 ka (8/20 µs) 1 kv 1.15 kv 1.3 kv 1.5 kv - N-PE follow current interrupting rating I fi - 100 A Temporary overvoltage U t (withstand) 335 V 405 V 490 V 580 V 1200 V Residual current I PE at U REF 1 ma - MOV voltage of 1mA point 387-473 V 460-561 V 554-677 V 639-781 V - Response time 25 ns 100 ns Max. back-up fuse max. 125 A gg - Short-circuit withstand capability 50 ka - Short-circuit current rating I SCCR 10 ka - Current factor k 1.6 - Number of ports 1 Type of LV system TN-C, TN-S, TN-C-S, TT (1+1, 3+1), IT (1+1, 3+1) Remote contact (optional) 1 changeover (CO) Remote contact op. voltage / current AC U max / I max DC U max / I max 250 V AC / 1 A 30 V DC / 1 A 4

Technical Data Ex9UE2 Surge Protection Devices Type 2, I n Mechanical parameters Device width 17.5 mm (per pole/module) Device height 83 mm (89 mm including rail clip) Frame size 45 mm Method of mounting fixed Mounting easy fastening onto 35 mm device rail (DIN) Mounting position arbitrary Degree of protection IP40, terminals IP20 Terminals M5 screws Terminal capacity 2.5 35 mm 2 Fastening torque of terminals 2 3.5 Nm Remote contact terminal capacity 0.14 1.5 mm 2 Location indoor Ambient temperature -40 +80 C Altitude 2000 m Relative humidity 30 90 % Weight (per pole) 0.11 kg Dimensions R R R R R 5

Technical Data Ex9UE2 Surge Protection Devices Type 2, I n SPD coordination L Ex9UE1 l min Ex9UE2 TN-S, TN-C TT (1+1) (4+0) Class I Class II Min. cable length l min Ex9UE1 35 Ex9UE2 x x 440 0 Ex9UE1 35 Ex9UE2 x x 275 10 m Connection diagrams, protection mode TN-S, TT (1+1) TN-S (2+0) Ex9UE1+2 12.5 1PN 275 TN-S, TT (1+1) TN-C TN-S, (3+0) TT (3+1) Ex9UE1+2 12.5 1PN 275 TN-S (2+0) Ex9UE1+2 12.5 12.5 2P 1PN 275 275 Ex9UE1+2 12.5 1PN 275 TN-S, TT (1+1) Ex9UE1+2 Ex9UE1+2 12.5 12.5 3P 2P 275 275 TN-S, TT (3+1) Ex9UE1+2 12.5 4P 3PN 275 275 Ex9UE1+2 12.5 3PN 275 TN-S (2+0) 6 Ex9UE1+2 12.5 2P 275 TN-S, TT (3+1)